Cleveland
™
P
roject ________________________________
Item __________________________________
Quantity _______________________________
F
CSI Section ____________________________
A
pproval _______________________________
D
ate __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
MODULAR BASES
MODULAR BASE WITH KETTLE(S)
DIRECT STEAM
ONE or TWO, 6 GALLON KETTLE(S)
CABINET BASE: 18" (450MM), 24" (600MM) or 36" (900MM) WIDE
Cleveland Standard Features
II
Factory assembled Kettle/Modular Base combination with
one or two, 6 gallon kettle(s) for direct connection to steam
from another source
II
Steam Control Kit: includes needle type Steam Control
Valve(s), Steam Trap, Condensate Strainer, Check Valve,
nipples and fittings, factory assembled and mounted on
kettle(s)
II
Type 430 Stainless Steel exterior enclosure, kettle(s) and
table top (with drain Trough which has 1.50" diameter male
drain); #4 exterior finish
II
6 gallon kettle(s) are 2/3 Steam Jacketed and include
Lift-Off Cover(s)
II
Hot and Cold Water Faucet with Swing Spout
II
Kettle(s) have 50 psi Steam Jacket Rating, 50 psi chrome
plated Safety Valve(s) and Manual Tilting, balanced design
II
Tilt Handles can be mounted on either side of kettle(s)
II
Adjustable Flanged Feet (FF-A)
MODELS: 18-DM-K6
24-DM-K6
36-DM-K66
Options & Accessories
Ë Type 316 Stainless Steel Kettle interior(s) for high acid food
products (316)
Ë Food Strainers (FS)
Ë Pressure Reducing Valve for incoming supply over 50 psi
(PRV)
Ë Stainless Steel Base Frame (FSS)
Short Form Specifications
Shall be CLEVELAND, Direct Steam, Modular Cabinet Base with one or two,
6 gallon kettle(s), Model _____ DM-K _____ Type 430 Stainless Steel exterior
enclosure, Table Top and 4 Level adjustable Feet. 2/3 Steam Jacketed, type
304 Stainless Steel kettle(s) with 50 psi Steam Jacket Rating. Needle type
Steam Control Valve on each kettle. To operate connect directly to a steam
source supplying from 5 to 10 psi steam. Steam Condensate Trap and
Strainer, factory assembled and installed. Includes Hot and Cold Water
Faucet with Spring Spout and Lift-Off Kettle Cover(s).
SECT. VII PAGE 35
0609
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards whether untreated or pre-treated,
based upon 10 hours of use per day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS less than 60 parts per million
TOTAL ALKALINITY less than 20 parts per million
SILICA less than 13 parts per million
pH FACTOR greater than 7.5
CHLORINE less than 30 parts per million
Consult a local water treatment specialist for an on site water analysis for recommendations
concerning steam generator feed water treatment (if required), in order to remove or
reduce harmful concentrations of minerals. The use of highly mineralized water will mean
that more frequent servicing of the steam generator will be necessary. The fact that a water
upply is potable is not proof that it will be suitable for the generator.
s
C
APACITIES
in 4 oz. servings)
(
(Other sizes may be calculated.)
6 gallon / 23 liters ..... 160 per kettle
1 1/2” IPS common drain.
Do not connect other units
to this drain.
Do not use PVC pipe for
drain.
NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are UL, ULC, UL/NSF#4 and CSA.
Right - 3”, Left - 3”, Rear - 3”
(12” on control side if
adjoining wall or equipment is
over 30” high for service
access)
Contact factory for
variances to clearances.
(NOT TO SCALE)
SECT. VII PAGE 36
0609
Litho in U.S.A.