ClearCube V7000, V7100S User Manual

s
ClearView IPMI 1.0
User’s Guide
V7100S Blade Management
ClearCube Technology, Inc.
Copyright© 2008 ClearCube Technology, Inc. All rights reserved.
Under copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical,
including photocopying, recording, storing in an information retrieval system, or translating, in whole or in part,
without the prior written consent of ClearCube Technology, Inc.
This information is subject to change without notice and ClearCube shall not be liable for any direct, indirect,
special, incidental or consequential damages in connection with the use of this material.
Trademarks
Sentral™, ClearCube™, C3 Architecture™, Blade Switching BackPack™, PC Blade™, and C/Port™
are trademarks of ClearCube Technology Inc. Product and company names mentioned herein
are trademarks or trade names of their respective companies.
Patents
The ClearCube Architecture and its components described in this user manual
are protected by numerous granted and pending U.S. and international patents.
Granted patents include: US05926172, US05966056, US05994952, US06012101, US06020839, US06037884,
US06038616, US06119146, US06148182, US06167241, US06385666, US06421393, US06426970,
US06633934, US06708247, US06735658, US06886055, and US06944826.
Inquiries regarding patented technology should be directed to
ClearCube Corporate Headquarters.
iii
Table of Contents
1. Overview .................................................................................................. 1
2. Login and Blade System ......................................................................... 2
2.1. Blade System View ............................................................................. 5
2.2. Blade UI .............................................................................................. 8
2.3. Power Supply UI ............................................................................... 10
2.4. Gigabit Switch UI .............................................................................. 12
2.5. CMM UI ............................................................................................ 16
2.6. InfiniBand UI ..................................................................................... 19
2.7. Failure Summary UI .......................................................................... 21
2.8. Blade Summary UI ........................................................................... 21
2.9. Power Supply Summary UI .............................................................. 22
2.10. Gigabit Switch Summary UI .............................................................. 23
3. Text Console .......................................................................................... 24
4. KVM Console and Optimizing Keyboard and Mouse Settings .......... 26
5. Event Log ............................................................................................... 28
6. Logon Management .............................................................................. 29
7. Virtual Media .......................................................................................... 32
8. CMM Setting ........................................................................................... 33
9. Connecting to the Slave CMM .............................................................. 34
1
1. Overview
You can use ClearCube ClearView IPMI to manage ClearCube V7000 chassis containing one or more Chassis Management Modules (CMM) and ClearCube V7100S blades. ClearView IPMI sends messages to and from the CMM. Messages are encapsulated in an RMCP+ (Remote Management Control Protocol) packet that follows the IPMI standard.
ClearView IPMI monitors and reports on the status of a V7100 system, including the blade server, power supply, gigabit switch, InfiniBand and CMM modules. ClearView IPMI shows the V7000 and V7100 in a GUI for easy management, enabling administrators to monitor the status of each blade module. ClearView IPMI also supports remote KVM and virtual media. This document describes how to use ClearView IPMI to manage V7000 and V7100 systems.
2
2. Login and Blade System
One V7000 chassis can have a maximum of two CMM modules, with one as the master CMM and the other one as the slave CMM. Only the master CMM has the full management functions for the V7000 chassis. For normal system management, you should connect to the master CMM. The slave CMM is also operating when the V7000 is turned on. It will take the role of master CMM if the original master CMM is reset or hangs. By the way, once slave CMM take over master, the master CMM will become the slave CMM.
In the ClearView IPMI device list, as shown in Figure 1-2, you will see the V7000 icon ( ) once the CMM added. Double-click this item to display the login screen. To login:
1. Type in your Username in the Login ID box.
2. Type in your Password in the Password box and click on Login.
3. The default username and the default password are both ADMIN.
Figure 1-2. Logging on to the V7000
3
Once you login successfully, the Blade System tab is displayed. This is the main system management UI (User Interface), as shown in Figure 1-3.
Figure 1-3. Blade System UI (User Interface)
The upper window displays the status of all blades being monitored. Any changes to the V7100S will be reflected in this view. For example, if someone removes blade module 1, you will see the blade 1 icon disappear (become grayed out). If you turn off blade module 10, the power LED on blade 10 will become amber. Different types of blade modules can occupy the same blade system. If you install a different type of blade module, its icon in the Blade System View will likewise appear slightly different due to its type. In this way, the Blade System View reflects a real and current picture of the V7100S modules.
Each module icon in the Blade System View can be clicked on to show a detailed list of functions in the bottom (Module User Interface) window. Additional summary items can be viewed as here well. The Module UI allows users to obtain additional information and send additional commands to the blade modules.
The Module UI has a detach button ( ) at the upper-right of the window. Clicking on it will detach the UI as a single window as shown in Figure 1-4. This is useful for
continual monitoring of a specific blade module.
Blade System View
Module UI
4
Figure 1-4. Detached Module UI Window
5
1.1. Blade System View
Figure 2-1. Blade System View
As shown in Figure 2-1, the Blade System View provides an overview of the V7000 and V7100S system.
There are four sections in the Blade System View:
Summary: Shows a summary of failures and how many of each type of module
have been installed. The Failure, Blade, Power and Switch items are shown in greater detail in the Module UI.
Blade System: As shown in Figure 2-2, the Blade System View shows both front
and rear views of the blade system. The front view shows blade module status while the rear view shows the status of the power supply, gigabit switch, InfiniBand and CMM. A yellow rectangle appears around an icon when it is selected (clicked on), as shown in Figure 2-3. Each icon has a symbol to show its current status. Each module may display one or more symbols. Refer to the Legend Help (Figure 2-4) to determine the meaning of a symbol. (Click Legend Help in the View Option window at the lower right area of the screen.)
Figure 2-2. Blade Module Layout
Blade Modules
Gigabit Switch
InfiniBand
(Or CMM)
Power Supply
Modules
CMM
6
Figure 2-3. Selected Blade Module and Corresponding Management UI
Figure 2-4. Legend Help
Chassis LED: Figure 2-5 shows the Chassis LED section, which displays the
Power and Error LEDs for the V7000 chassis. The Power LED shows the current Blade System power status. The Error LED indicates a system over temperature or fan failure condition. The Legend Help box also shows the various states indicated by the Classis LED.
7
Figure 2-5. Chassis LED and Legend Help
View Option: This option allows a user to choose to show or hide the module
status, picture and number. Figure 2-6 and Figure 2-7 show the results of two different sets of View Options checked.
Figure 2-6. Show Status and Number, Hide Picture
Figure 2-7. Only Show Picture
Popup Menu Supported: A user can right click on a blade module to enable a
popup window to perform certain actions. As shown in Figure 2-8, right clicking on a blade displays a window with power, UID and KVM functions.
Figure 2-8. Blade Popup Menu
8
1.2. Blade UI
Figure 2-9. Blade UI
Click on a blade module. The Blade UI as shown in Figure 2-9 will appear in the Module UI section at the bottom of the screen. It contains the following:
Status
Power Status: Shows the current power status. Indications include power on,
power off and power fail status.
KVM: This shows whether KVM is selected or not. Click the Request button to
request KVM on this blade.
UID: This shows the status of the UID LED. Select the Enable option to enable or
disable the UID. Once the UID enabled, the UID LED on the blade panel will flash.
System Fault: This indicates the system fault status. BMC: Shows BMC status. If BMC is installed, the BMC IP address will appear
here. Click the Update button ( ) to update the BMC IP as shown in Figure 2-10. Click the Refresh button ( ) to reload the BMC IP. If a BMC is not installed, not installed appears and the Update and Refresh buttons are disabled.
Watt: The estimated power consumption (wattage) of this blade. It is a static
value supplied by BIOS.
Figure 2-10. Updating the BMC IP
9
Power Control
Power On: Click to power on the blade. Reset: Click to reset the blade. Graceful Shutdown: Click to perform a graceful shutdown on the blade. Power Down: Click to power down the blade.
Figure 2-11. Power Control Buttons
Sensors
As seen in Figure 2-12, the title of the sensor table displays the blade motherboard. The sensor table shows the CPU(s), system temperature and voltages of the currently selected blade. The table headers indicate the status, sensor name, reading and the low and high limits. If the status of a sensor is normal, the reading value is displayed in blue and an OK symbol ( ) is displayed at the beginning of the row. If a sensor status is out of range, the reading will be red and the sensor will have a fail symbol ( ). If the sensor is not present, the reading will be displayed as N/A and without a status symbol.
Figure 2-12. Blade Sensor Table