Clear-Com TW-47 User Manual

CLEAR-COM ENCORE
TW-47 TWO-WAY RADIO INTERFACE
INSTRUCTION MANUAL
TW-47 Two-Way Radio Interface Instruction Manual
© 2007 Vitec Group Communications Ltd. All rights reserved.
Part Number 810502Z Rev. 2
Vitec Group Communications, LLC. 850 Marina Village Parkway Alameda, CA 94501 U.S.A
Vitec Group Communications 7400 Beach Drive Cambridge Research Park Cambridgeshire United Kingdom CB25 9TP
Vitec Group Communications Room 1806, Hua Bin Building No. 8 Yong An Dong Li Jian Guo Men Wai Ave Chao Yang District Beijing, P.R. China 100022
® Clear-Com,CellCom/FreeSpeak and the Clear-Com Communication Systems logo are registered trademarks of The Vitec Group plc.

CONTENTS

OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Before you Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Features of the TW-47 System . . . . . . . . . . . . . . . . . . 1-1
Description of the TW-47 . . . . . . . . . . . . . . . . . . . . . 1-2
RF Interference . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Connecting the TW-47 to the Base Station Radio . . . 1-3
Building Your Custom Cable . . . . . . . . . . . . . . . . . . . 1-4
Option Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
Output Level Jumpers . . . . . . . . . . . . . . . . . . . . . . 1-8
Transmit Key Jumper . . . . . . . . . . . . . . . . . . . . . . . 1-9
Call Signal Frequency Adjust . . . . . . . . . . . . . . . . . 1-9
Check Out and Operation of the TW-47 System . . . 1-9
TW-47 Front Panel Controls and Lights . . . . . . . . . 1-11
Rear Panel of TW-47 . . . . . . . . . . . . . . . . . . . . . . . . 1-12
INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Wiring Cables for Specific Radio Types . . . . . . . . . . . 2-1
For Motorola: Radius, GP300, SP-50, and Sport 7x2-1 For Yaesu: FT-411, 811, 911; FT-415, 815; FT-530; FT-
416, 816; FT-11R, 41R . . . . . . . . . . . . . . . . . . . . . . . 2-1
For Uniden: Model SPH; Motorola: Radius P-50 . 2-2
SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . 3-1
iTW-47 TWO-WAY RADIO INTERFACE
TW-47 Technical Specifications. . . . . . . . . . . . . . . . . 3-1
Radio to Party Line . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Party Line to Radio . . . . . . . . . . . . . . . . . . . . . . . . 3-1
LIMITED WARRANTY . . . . . . . . . . . . . . . . . . . . . 4-I
Warranty Period. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-i
Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-ii
Warranty Repairs and Returns . . . . . . . . . . . . . . . . . .4-iii
Non-Warranty Repairs and Returns. . . . . . . . . . . . . .4-iv
Extended Warranty . . . . . . . . . . . . . . . . . . . . . . . . . .4-iv
Liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-v
ii
TW-47 TWO-WAY RADIO INTERFACE
IMPORTANT SAFETY INSTRUCTIONS

1. Read these instructions.

2. Keep these instructions.

3. Heed all warnings.

4. Follow all instructions.

5. Do not use this apparatus near water.

6. Clean only with dry cloth.

7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

9. Only use attachments/accessories specified by the manufacturer.

10. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

11. Unplug this apparatus during lightning storms or when unused for long periods of time.

12. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

13. WA RN IN G: To reduce the risk of fire or electric shock, do not expose this product to rain or moisture.

iTW-47 TWO-WAY RADIO INTERFACE
Please familiarize yourself with the safety symbols in Figure 1. When you see these symbols on this product, they warn you of the potential danger of electric shock if the station is used improperly. They also refer you to important operating and maintenance instructions in the manual.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
This symbol alerts you to the presence of uninsulated dangerous voltage within the product's enclosure that might be of sufficient magnitude to constitute a risk of electric shock. Do not open the product's case.
This symbol informs you that important operating and main­tenance instructions are included in the literature accompanying this product.
Figure 1: Safety Symbols
ii
TW-47 TWO-WAY RADIO INTERFACE
EMC AND SAFETY
The TW-47 Two-Way Radio Interface meets all relevant CE and FCC specifications set out below:
EN55103-1 Electromagnetic compatibility. Product family standard for audio, video, audio-visual, and entertainment lighting control apparatus for professional use. Part 1: Emissions.
EN55103-2 Electromagnetic compatibility. Product family standard for audio, video, audio-visual, and entertainment lighting control apparatus for professional use. Part 2: Immunity.
And thereby compliance with the requirement of Electromagnetic Compatibility Directive 2004/108/EC and Low Voltage Directive 2006/95/EC
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
iiiTW-47 TWO-WAY RADIO INTERFACE
iv
TW-47 TWO-WAY RADIO INTERFACE

1 OPERATION

INTRODUCTION

Congratulations on choosing this Clear-Com product. Clear-Com was established in 1968 and remains the market leader in providing intercoms for entertainment, educational, broadcast and industrial applications. The ruggedness and high build-quality of Clear-Com products defines the industry standard. In fact, many of our original beltpacks and main stations are still in daily use around the world.

BEFORE YOU BEGIN

To get the most out of your Clear-Com equipment, read this manual carefully. It will answer many questions you may have about operating and servicing your equipment. You may also call Clear-Com’s customer service department at (510) 337-6600 for answers to any questions that are not covered in this manual.

FEATURES OF THE TW-47 SYSTEM

• Any walkie-talkie with an external microphone input and
earphone output can be connected to the TW-47.
• Clear-Com or TW Channel A or B intercom line operation.
• Powered from the intercom system.
• Base station radio keyed from intercom call signal.
• Visual transmitter keying indicator.
• Audio level indicator.
TW-47 TWO-WAY RADIO INTERFACE
1-1
Loading...