Clear-Com FreeSpeak Battery Pack Charger User Manual

R
R
MULTI-BAY CHARGE
CELLCOM® / FREESPEAK® CEL-FS-CHRG
INSTRUCTION MANUAL
Max Input Voltage 15.0VDC Output (5 bays) Smart charging for 4.8V 2500mAH
Fast Charge Current 800mA Trickle Charge Current 50mA (average) Maximum Charge Time 360 minutes Over-Temperature detect 60 °C
CEL-FS-CHRGR Multi-bay Charger Instruction Manual 810366Z – Rev 4.0 ©2006 Vitec Group Communications www.clearcom.com
Clear-Com is a registered trademark of Vitec Group Communications, Inc. The Clear-Com Logo is a registered trademark of Vitec Group Communications, Inc.
FreeSpeak is a registered trademark of Vitec Group Communications,Ltd Cellcom is a registered trademark of Vitec Group Communications, Inc.
used with the following battery types:
PANASONIC P6P 2500mAH / 2600mAH Ni-MH 1.2V AA
Charging State and fault conditions are indicated by the status of the Red and Green LEDs of each charging bay

SUMMARY OF LED STATUS – Normal Operation

Red LED ON………………………………………Fast charging Green LED ON…………………………………….Trickle charging

SUMMARY OF LED STATUS– Fault Conditions

Red LED Flashing…………………………………Short Circuit in battery pack Green LED Flashing…………………………..….Cells in pack will not charge
Remove the battery pack and investigate.
OVER-TEMPERATURE
If the temperature of the battery pack exceeds approximately 60°C in fast charge mode, the charging will revert to trickle charging. The red LED turning OFF, and the green LED turning ON will indicate this.
Excessive heating of the battery pack may be caused by not using the recommended batteries or by mixing batteries from more than one manufacturer.

SPECIFICATIONS

Mains Power Supply Unit

AC input voltage 100-240VAC 50/60Hz Output voltage +12VDC Output current (max load) 2.50A Output current (min load) 0.00A Short Circuit Protection Yes

Charger

Input Voltage 12.0VDC +/- 5%
battery pack.
Short Circuit detect Yes DC connection Jack 5.5 x 2.1mm (C+)
Batteries
Vitec Group Communications recommend that the charger should only be

General

Operating Temperature 0 °C to 40 °C Operating Humidity 0% to 90% R.H. Storage Temperature for Charger and PSU. -20 °C to 80 °C
iv.

IMPORTANT SAFETY INSTRUCTIONS

(1) WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. (2) Do not use the apparatus near water. (3) Clean only with a dry cloth. (4) Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. (5) Do not expose to any heat sources such as radiators, heat registers / vents, stoves, or other apparatus (including amplifiers) that produce heat.
Please read and follow these instructions before operating the CEL-FS-CHRGR. Keep these instructions for future reference.
(6) Protect power leads from being walked on or pinched. (7) Unplug the apparatus during lightning storms or when unused for long periods of time. (8) Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as a power­supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. CAUTION: Danger of explosion or injury if any of the batteries fitted in the belt pack battery pack are not NiMH re-chargeable types. Do NOT use
alkaline batteries.
Replace batteries only with manufacturer’s recommended type of AA size NiMH batteries.

INTRODUCTION

The CEL-FS-CHRGR can be used to re-charge up to five Cellcom ® or Freespeak ® beltpack battery packs in place of the beltpacks’ internal charging circuit. This allows a beltpack to be used with one battery pack whilst a second battery pack is being charged. Additional battery packs and batteries can be purchased from your Clear-Com supplier.
The CEL-FS-CHRGR features intelligent circuitry to prevent overcharging. It optimises charging by fast charging for a period and then trickle charging.

INSTALLATION REQUIREMENTS

The CEL-FS-CHRGR mains power supply requires an electrical supply of 100­240VAC 50/60Hz.

INSTALLATION

Connect the power supply unit to the CEL-FS-CHRGR via the DC input on the right side of the CEL-FS-CHRGR. Connect the correct mains adaptor for your country to the CEL-FS-CHRGR mains power supply. Plug the adaptor in to the mains electricity supply.

OPERATION

Insert a belt pack battery pack into one of the five charger bays with the electrical contacts on the battery pack facing downwards. The bays are polarized so the battery packs can only be inserted one way around. The bay’s red LED should light to indicate fast charging is occurring.
After a period of approximately four hours for a set of exhausted batteries, the red LED should extinguish and the green LED should light. This indicates that fast charging is over and trickle charging has commenced. Batteries that are not fully exhausted will take less time to charge. A battery pack can be removed for use after the fast charge period is over but may not be fully charged until a period of trickle charging has occurred. Trickle charging will continue until the battery pack is removed. The exact time period for a full charge, including trickle charge period will depend on the original charge state of the batteries in the battery pack and the number of charge- recharge cycles that the batteries have experienced.
Up to five battery packs can be charged independently at one time. Packs may be inserted or removed independently of each other.
i.
ii.
Insert battery pack into charger bay with contacts facing down.
.
Red LED ON – Fast Charging
Green LED ON – Trickle Charging
Insert DC Power here
iii.