Clay Paky SPHERISCAN C11260, SPHERILIGHT C11270 Instruction Manual

1
INSTRUCTION MANUAL
Congratulations on choosing a Clay Paky product! We thank you for your custom. Please note that this product, as all the others in the rich Clay Paky range, has been designed and made with total quality to ensure excellent performance and best meet your expectations and requirements.
ENGLISH
SPHERISCAN
SPHERILIGHT
C11260
C11270
PR
E
LIM
IN
A
R
Y
INDEX
Page Contents
2 Safety Information
4 Unpacking and preparation
5 Installation and start-up
6 Control panel
8 Menu setting
16 Maintenance
26 Technical information
27 Cause and solution of problems
28 Channel functions
2
SPHERISCAN - SPHERILIGHT
Carefully read this instruction manual in its entirety and keep it safe for future reference. It is essential to know the i
nformation and comply with the instructions given in this manual to ensure the fitting is installed, used and serviced correctly and safely. CLAY PAKY S.p.A. disclaims all liability for damage to the fitting or to other property or persons deriving from installation, use and maintenance that have not been carried out in conformity with this instruction manual, which must always accompany the fitting. CLAY PAKY S.p.A. reserves the right to modify the characteristics stated in this instruction manual at any time and without prior notice.
• Installation
Make sure all parts for fixing the projector are in a good state of repair. Make sure the point of anchorage is stable before positioning the projector. The safety chain must be properly hooked onto the fitting and secured to the framework, so that, if the primary support system fails, the fitting falls as little as possible. If the safety chain gets used, it needs to be replaced with a genuine spare.
• Minimum distance of illuminated objects
The projector needs to be positioned so that the objects hit by the beam of light are at least 3 metres (9’10”) from the lens of the projector.
• Minimum distance from flammable materials
The projector must be positioned so that any flammable materials are at least 0.20 metres (8") from every point on the surface of the fitting.
• Maximum ambient temperature
Do not operate the fixture if the ambient temperature (Ta) exceeds 40° C (104° F).
• IP54 protection rating
The fixture is protected against dust (first digit 5) and splash (second digit 4).
• Protection against electrical shock
Connection must be made to a power supply system fitted with efficient earthing (Class I appliance according to standard EN 60598-1). It is, moreover, recommended to protect the supply lines of the projectors from indirect contact and/or shorting to earth by using appropriately sized residual current devices.
• Connection to mains supply
Connection to the electricity mains must be carried out by a qualified electrical installer. Check that the mains frequency and voltage correspond to those for which the projector is designed as given on the electrical data label. This label also gives the input power to which you need to refer to evaluate the maximum number of fittings to connect to the electricity line, in order to avoid overloading. If the projector is used in residential environment, in some cases it might be necessary to adopt appropriate measures to avoid EMI disturbances to broadcast receiver equipment.
• Temperature of the external surface
The maximum temperature that can be reached on the external surface of the fitting, in a thermally steady state, is 150°C (302°F).
• Maintenance
Before starting any maintenance work or cleaning the projector, cut off power from the mains supply. After switching off, do not remove any parts of the fitting for at least 10 minutes. After this time the likelihood of the lamp exploding is virtually nill. If it is necessary to replace the lamp, wait for another 20 minutes to avoid getting burnt. The fitting is designed to hold in any splinters produced by a lamp exploding. The lenses must be mounted and, if visibly damaged, they have to be replaced with genuine spares.
• Lamp
The fitting mounts a high-pressure lamp that needs an external igniter. This igniter is fitted onto the apparatus.
- Carefully read the "operating instructions" provided by the lamp manufacturer.
- Immediately replace the lamp if damaged or deformed by heat.
• Photobiological Safety
CAUTION. Do not look directly at the light source. Do not look at the light beam with optical devices or any other tool that could cause light convergence. The fixture must be positioned so that the minimum distance between the front lens and human eye is at least 2 metres to prevent personal photobiological risks.
SAFETY INFORMATION
IP54
3
tc150°C
Risk Group 1
According to
EN 62471
EN
3
SPHERISCAN - SPHERILIGHT
This product is intended for the following areas of application: studios, stages, theaters, exhibitions, trade fairs, events, theme parks, entertainment venues, architectural lighting and similar.
Not suitable for household illumination
Not for residential use
• Battery
This product contains a rechargeable lithium iron tetraphosphate battery. To preserve the environment, please dispose the battery at the end of its life according to the regulation in force.
Disposing
This product is supplied in compliance with European Directive 2012/19/EU - Waste Electrical and Electronic Equipment (WEEE). To preserve the environment please dispose/recycle this product at the end of its life according to the local regulation.
LiFePO4
The products to which this manual refers comply with the European Directives pursuant to:
• 2006/95/EC - Safety of electrical equipment supplied at low voltage (LVD)
• 2004/108/EC - Electromagnetic Compatibility (EMC)
• 2011/65/EU - Restriction of the use of certain hazardous substances (RoHS)
• 2009/125/EC - EcoDesign requirements for Energy-related Products (ErP)
EN
IT
DE
ES
FR
RU
HOW TO GET YOUR SAFETY INSTRUCTIONS IN MULTILINGUAL VERSION
You may always download the multilingual Safety Instruction manual for this Clay Paky product from:
http://www.claypaky.it/en/download
Ref: [FIS00M – Safety Information Spheriscan / Spherilight]
COME OTTENERE LE INFORMAZIONI DI SICUREZZA NELLA VERSIONE MULTILINGUE
Puoi sempre scaricare la versione multilingue delle Informazioni di Sicurezza per questo prodotto Clay Paky al seguente link:
http://www.claypaky.it/en/download
Rif: [FIS00M – Safety Information Spheriscan / Spherilight]
SO ERHALTEN SIE IHR INFORMATIONEN ZUR SICHERHEIT IN DER MEHRSPRACHIGEN VERSION
Sie können die mehrsprachige Version des Handbuchs mit Sicherheitshinweisen fur dieses Clay Paky- Produkt unter folgendem Link herunterladen:
http://www.claypaky.it/en/download
Ref: [FIS00M – Safety Information Spheriscan / Spherilight]
COMO OBTENER TU INFORMACIONES DE SEGURIDAD EN LA VERSION MULTILINGUE
Siempre puedes descargar la versión multilingue del Manual de Instrucciones de Seguridad para este producto Clay Paky en el siguiente enlace
http://www.claypaky.it/en/download
Ref: [FIS00M – Safety Information Spheriscan / Spherilight]
COMMENT OBTENIR VOTRE CONSIGNES DE SÉCURITÉ DANS LA VERSION MULTILINGUE
Vous pouvez toujours télécharger la version multilingue du Manuel d’Instructions de Sécurité pour ce produit Clay Paky au lien suivant :
http://www.claypaky.it/en/download
Réf. : [FIS00M – Safety Information Spheriscan / Spherilight]
ГДЕ ДОСТАТЬ ИНСТРУКЦИЮ ПО ТЕХНИКЕ БЕЗОПАСНОСТИ НА НЕСКОЛЬКИХ ЯЗЫКАХ
Вы всегда можете скачать многоязычную инструкцию по технике безопасности для данного изделия Clay Paky по ссылке:
http://www.claypaky.it/en/download
Наименование: [FIS00M – Safety Information Spheriscan / Spherilight]
4
SPHERISCAN - SPHERILIGHT
UNPACKING AND PREPARATION
1
Installing the projector - Fig. 2 The projector can be installed on the floor resting, on a truss or on the ceiling or wall.
WARNING: with the exception of when the projector is positioned on the floor, the safety cable must be fitted. (Cod. 105041/001 available on request). This must be securely fixed to the support structure of the projector and then connected to the fixing point as shown on the pictures above.
2
Packing contents - Fig. 1
5
SPHERISCAN - SPHERILIGHT
2
1
1
2
3
3
INSTALLATION AND START-UP
Connecting and disconnecting power cable - Fig. 3
6
SPHERISCAN - SPHERILIGHT
Switching on the projector - Fig. 6 Press the switch. The projector starts resetting the effects. At the same time, the following information scrolls on the display:
The control panel (Fig. 6) has a display and buttons for the complete programming and management of the projector menu. The display can be in one of two conditions: rest status and setting status. When it is in the rest status, the display shows the projector’s DMX address and the Fixture ID address (if set). During menu setting status, after a wait time (about 30 seconds) without any key having been pressed, the display automatically returns to rest status. It should be noted than when this condition occurs, any possible value that has been modified but not yet confirmed with the
F
key will be cancelled.
CONTROL PANEL
1
2
Dmx Address
Warning Message
Fixture ID
6
Firmware Version X.X.X Date - Hour
Connecting to the control signal line (DMX) - Fig. 5
Use a cable conforming to specifications EIA RS-485: 2-pole twisted, shielded, 120Ohm characteristic impedance, 22-24 AWG, low capacity. Do not use microphone cable or other cable with characteristics differing from those specified. The end connections must be made using XLR type 5-pin male/female connectors. A terminating plug must be inserted into the last projector with a resistance of 120Ohm (minimum 1/4 W) between terminals 2 and 3. IMPORTANT: The wires must not make contact with each other or with the metal casing of the connectors. The casing itself must be connected to the shield braid and to pin 1 of the connectors.
Connecting to the mains supply - Fig. 4
Mains
4
5
xxx (Fixture ID) Dmx Address xxx
System errors
E: .........................
W: .........................
SPHERISCAN - SPHERILIGHT
7
28
28
Reversal of the display - Fig. 7 To activate this function, press UP
B
and DOWN Ckeys simultaneously while the display is in the rest mode. This status will be memorised and
maintained even for the next time it will be switched on. To return to the initial state, repeat the operation all over again.
S
etting the projector starting address
On each projector, the starting address must be set for the control signal (addresses from 1 to 512). The address can also be set with the projector switched off.
Setting the projector Fixture ID
On each projector, the Fixture ID address must be set for an easy identification of the fixtures in an installation (ID from 1 to 255). The Fixture ID address can be set with the projector switched off.
7
Functions of the buttons - Using the menu
Setting addresses and options with the projector disconnected
The projector’s DMX address, as well as other possible operating options, can also be set when the appliance is disconnected from the electricity supply. All that is needed is to press
F
to momentarily activate the display and thus access the settings. Once the required operations have been carried out,
the display will switch off again after a wait time of 30 seconds.
USING THE MENU:
1) Press
F
once – “Main Menu” appears on the display.
2) Use the UP
B
and DOWN Ckeys to select the menu to be used:
• Setup (Setup Menu): To set the setting options.
• Option (Option Menu): To set the operating options
• Informations (Informations Menu): To read the counters, software version and other information.
• Manual Control (Manual control Menu): To trigger the test and manual control functions.
• Test (Test Menu): To check the proper functionning of effects
• Advanced (Advanced Menu): Access to the "Advanced menu" is recommended for a trained technical personnel. To enable the "Advanced" see pag.15.
3) Press
F
to display the first item in the selected menu.
4) Use the UP
B
and DOWN Ckeys to select the MENU items.
Confirms the displayed value, or activates the displayed function, or enters the successive menu.
Decreases the value displayed (with auto-repetitions) or passes to the next item in the menu.
Increases the value displayed (with auto-repetitions) or passes to the previous item in a menu.
Return to the top level
Commute from units, tens, hundreds, in the "Address", "Fixture ID" and "Calibration" menù.
F
C
DOWN
B
UP
D
LEFT
E
RIGHT
8
SPHERISCAN - SPHERILIGHT
MENU SETTING
Main Menu Level 1 Level 2 Level 3 Choices / Values
SET UP
DMX Address
Æ Æ
001-512
Channel Mode
Æ Æ
Standard
Vector
Fixture ID
Æ Æ
000-255
Ethernet Interface
C
ontrol Protocol
Æ
Disabled
Art-net IP 2.x.x.x.
A
rt-net IP 10.x.x.x.
Art-net Custom IP
Repeat on DMX
Æ
Disabled
Enabled on primary
Universe
Æ
000-255
Custom IP Address
IP address byte 1 IP address byte 2 IP address byte 3 IP address byte 4
000-255 000-255 000-255 000-255
Custom IP Mask
IP mask byte 1 IP mask byte 2 IP mask byte 3 IP mask byte 4
000-255 000-255 000-255 000-255
OPTION
Lamp DMX
Æ Æ
On / Off
Pan / Tilt Pan Short-cut
Æ
On / Off
Color
Color Mixing
Æ
RGB / CMY
Fix Wheel Shortcut
Æ
On / Off
Shutter
Shutter On Error
Æ
On / Off
Dimmer On Shutter
Æ
On / Off
Display
Æ Æ
On / Off
Settings
Default Preset
Reset To Default
Go Back
Are you sure
?
Yes / No
User Preset 1
Load preset 1
Save to preset 1
Are you sure
?
Yes / No
User Preset 2
Load preset 2
Save to preset 2
Are you sure
?
Yes / No
User Preset 3
Load preset 3
Save to preset 3
Are you sure
?
Yes / No
9
SPHERISCAN - SPHERILIGHT
M
ain Menu
L
evel 1
L
evel 2
L
evel 3
C
hoices / Values
INFORMATION
System Errors
Æ Æ
Read / Reset
F
ixture Hours
Total Hours
Æ
Read
Partial Hours
Æ
Read / Reset
L
amp Hours
T
otal Hours
Æ
R
ead
Partial Hours
Æ
Read / Reset
Lamp Strikes
Total Strikes
Æ
Read
Partial Strikes
Æ
Read / Reset
System Version
CPU brd
Æ
Fw.rev. / Hw.rev.
com.dev
Æ
Fw.rev.
0:PT-3f
Æ
Fw.rev. / Hw.rev.
1:8-Ch
Æ
Fw.rev. / Hw.rev.
2:8-Ch
Æ
Fw.rev. / Hw.rev.
3:8-Ch
Æ
Fw.rev. / Hw.rev.
Board Diagnostic
0:PT-3f
Æ
Status / Err%
1:8-Ch
Æ
Status / Err%
2:8-Ch
Æ
Status / Err%
3:8-Ch
Æ
Status / Err%
DMX Monitor Channels
Æ
Value / Percentage
Fans Monitor
Board
Æ
Speed (RPM)
Lamp
Æ
Speed (RPM)
Lamp
Æ
Speed (RPM)
Eff. IN
Æ
Speed (RPM)
Eff. IN
Æ
Speed (RPM)
Ball. IN
Æ
Speed (RPM)
Ball. IN
Æ
Speed (RPM)
Sensor status Channels
Æ
n.a / On / Off
Rot. Gobo 1 Indexing
Æ Æ
Indexing Active
Indexing Required
Rot. Gobo 2 Indexing
Æ Æ
Indexing Active
Indexing Required
Network parameters
Æ Æ
IP Address
Æ Æ
IP Mask
Æ Æ
MAC Address
Continue
10
SPHERISCAN - SPHERILIGHT
Main Menu Level 1 Level 2 Level 3 Choices / Values
MA
NUAL
C
ONTROL
L
amp
Æ Æ
O
n / Off
R
eset
Æ Æ
Y
es / No
Channel
Æ Æ
Value / Percentage
TEST
Pan / Tilt
Æ Æ
n.a.
Colour
Æ Æ
n.a.
Beam
Æ Æ
n.a.
Gobo
Æ Æ
n.a.
A
ll
Æ Æ
n
.a.
ADVANCED Access Code 1234
U
pload Firmware Transfer ……..
A
re you sure
?
Yes / No
Setup Model Changing ……..
Are you sure
?
Yes / No
Calibration Channels 000 - 255
Rot. Gobo 1 Indexing
Starting procedure …..
Yes / No
Rot. Gobo 2 Indexing
Starting procedure …..
Yes / No
Menu Locking Unlock Code XXXX
11
SPHERISCAN - SPHERILIGHT
S
ET UP MENU
DMX ADDRESS
PLEASE NOTE: Without the DMX input signal, the displayed address (DMX Address) blinks.
It lets you select the address (DMX Address) for the control signal. A DMX address between 001 and 512 can be s
elected.
CHANNEL MODE
This lets you select the projector operating mode, selecting one of the two available modes:
• Standard (see DMX-Channel Function)
Vector (see DMX-Channel Function)
FIXTURE ID
It lets you set the “Fixture ID” to be assigned to the projector. An “ID” between 000 and 255 can be assigned.
ETHERNET INTERFACE
It lets you set Ethernet settings to be assigned to the projector as indicated below:
Control Protocol
It lets you select the “Control Protocol” Art-net to be assigned according to the control unit used; the options available are the following:
Disabled:
Art-net on IP 2
Art-net on IP 10
Art-net Custom IP
If the Control Protocol option is set on Disabled, when an IP address (IP2, IP10 or IP Custom) is selected, the projector immediately initializes the IP address that was just selected. If the Control Protocol option is enabled (IP2, IP10 or IP Custom) and a new one is selected that is different from the previous one, the projector must be restarted so that it will be correctly initialized.
Repeat on DMX
It lets you enable/disable the transmission of the Ethernet protocol by DMX signal to all the connected projectors.
Disabled: DMX transmission disabled.
Enabled on primary: DMX transmission enabled.
Universe
It lets you set the “DMX Universe” to be assigned to a series of projectors with values between 000 and 255.
Custom IP Address
It lets you to set the select the “IP Address” Art-net to be assigned, according to the control unit used, with values between 000 and 255.
Custom IP Mask
It lets you to set the select the “IP Mask” Art-net to be assigned, according to the control unit used, with values between 000 and 255.
Continue
12
SPHERISCAN - SPHERILIGHT
O
PTIONS MENU
L
AMP DMX
It lets you enable (ON) the lamp remote control channel. Select OFF to turn off or disable this option.
PAN / TILT P
an Short-cut
Used for optimizing Pan change time (select ON) so that the Pan moves in the direction that requires shorter movement. Select OFF to turn off or disable this option.
COLOR Color mixing
It lets you set the CMY color mixing system:
RGB color mixing mode (Red Green Blue)
CMY color mixing mode (Cyan Magenta Yellow)
SHUTTER Shutter on error
It lets you activate (ON) automatic "Stopper/Strobe" closing in the event of Pan/Tilt positioning error. Select OFF to turn off or disable this option.
Dimmer on Shutter
Enables (select ON) the automatic closing of the Dimmer when the Strobe is completely closed. Select OFF to turn off or disable this option.
DISPLAY
It lets you activate (ON) display brightness reduction after about 30 seconds in idle status. Select OFF to turn off or disable this option.
SETTINGS
Used to save 3 different settings of the items in the option menu and relevant submenus.
Default preset (*)
User preset 1
User preset 2
User Preset 3
- Load preset 'X’ is used to recall a previously stored configuration.
- Save to preset ‘X’ is used to save the current configuration.
(*) DEFAULT PRESET It lets you restore default values on all option menu items and relevant submenus.
Press the left and right arrows/keys simultaneously in the "main menu” to quickly restore default values (DEFAULT PRESET).
13
SPHERISCAN - SPHERILIGHT
I
NFORMATION MENU
S
YSTEM ERRORS
It displays a list of errors that occurred when the projector was turned on. To reset the SYSTEM ERRORS list, press OK. A confirmation message appears (Are you sure you want to clear error list?). Select YES to confirm reset.
FIXTURE HOURS
It lets you view projector working hours (total and partial).
T
otal counter
It counts the number of projector working life hours (from construction to date).
Partial counter
It counts the number of projector partial working life hours from the last reset to date.
Press OK to reset the partial counter. A confirmation message appears on the display (Are you sure ?) Select YES to confirm reset.
LAMP HOURS
It lets you view lamp working hours (total and partial).
Total counter
It counts the number of projector working hours with the lamp on (from construction to date).
Partial counter
It counts the number of lamp partial working hours from the last reset to date.
Press OK to reset the partial counter. A confirmation message appears on the display (Are you sure ?) Select YES to confirm reset.
LAMP STRIKES
It lets you view how many times the lamp was turned on (total and partial).
Total counter
It counts the number of times the lamp was turned on (from construction to date).
Partial counter
It counts the number of times the lamp was turned on from the last reset to date.
Press OK to reset the partial counter. A confirmation message appears on the display (Are you sure ?) Select YES to confirm reset.
SYSTEM VERSION
It lets you view the hardware and software versions for each electronic board in the projector.
CPU brd (CPU board)
0: PT-3f (Pan / Tilt board)
1: 8-Ch (8-channel board)
2: 8-Ch (8-channel board)
3: 8-Ch (8-channel board)
BOARD DIAGNOSTIC
It lets you view the percent errors for each electronic board installed in the projector
0: PT-3f (Pan / Tilt board)
1: 8-Ch (8-channel board)
2: 8-Ch (8-channel board)
3: 8-Ch (8-channel board)
DMX MONITOR
It lets you view the level of projector DMX channels in bit (Val) and in percent.
Continue
14
SPHERISCAN - SPHERILIGHT
FANS MONITOR
It lets you view the speed of each fan installed in the projector:
Board (board cooling fan)
Lamp (lamp cooling fan)
Ball.IN (Ballast cooling fan, air-flow IN)
Effect.IN (Effects cooling fan, air-flow IN)
SENSOR STATUS
It lets you check the correct operations of each "sensor” installed in the projector, each channel is associated with one of t
he following three parameters:
n.a.= sensor not available
ON= sensor working
OFF= sensor defective
ROT GOBO 1 INDEXING
It lets you check whether the rotating gobo wheel 1 gobo indexing procedure should be run, if indexed, "Indexing Active" appears on the display, otherwise "Indexing required!” appears
If necessary, indexing should be activated from the Advanced menu.
ROT GOBO 2 INDEXING
It lets you check whether the rotating gobo wheel 2 gobo indexing procedure should be run, if indexed, "Indexing Active" appears on the display, otherwise "Indexing required!” appears
If necessary, indexing should be activated from the Advanced menu.
NETWORK PARAMS
Lets you view the projector "Network" parameters meaning:
IP address: Internet Protocol address (two projectors must not have the same IP address) IP mask: 255.0.0.0 Mac address: Media Access Control; the projector’s Ethernet Address.
15
SPHERISCAN - SPHERILIGHT
M
ANUAL CONTROL
LAMP
It lets you turn the lamp on (ON) or off (OFF) from the projector control panel.
RESET
It lets you reset the projector from the projector control panel.
CHANNEL
It lets you set the channel DMX levels from the projector control panel (value between 0 and 255 bit or between 0% and 100%).
TEST MENU
It lets you test the correct operations of effects using saved Tests.
ADVANCED MENU
To open the “Advanced Menu”, enter the code (1234)
UP LOAD FIRMWARE
It lets you transfer "firmware" from one projector to all other connected projectors. A confirmation message appears on the display (Are you sure ?) Select YES to confirm or NO to abort this operation.
SETUP MODEL
It lets you change the projector model (operation probably necessary after replacing the CPU during repairs). A confirmation message (Are you sure ?) appears on the display Select YES to confirm (the list of available and selectable projectors appears) or NO to abort this operation.
CALIBRATION
It lets you make small mechanical adjustments on some effects to perfectly align projectors from the control panel.
Factory default
It lets you restore default "Calibration” values (128 bit) on all channels.
ROT GOBO INDEXING
It lets you run the rotating gobo wheel gobo indexing procedure. This operation may be necessary after projector maintenance/cleaning.
MENU LOCKING
It allows you to assign a password to lock the access to the user menu, so that only users know the password can change settings. The password is 4-digit number.
1
3
2
4
8
Opening the covers - Fig. 8.
16
SPHERISCAN - SPHERILIGHT
MAINTENANCE
17
SPHERISCAN - SPHERILIGHT
1
2
3
9
Fan assembly removal - Fig. 9.
Continue
18
SPHERISCAN - SPHERILIGHT
1
2
3
6
4
5
7
8
1
0
Fan /Driver assembly removal - Fig. 10.
19
SPHERISCAN - SPHERILIGHT
1
1
Periodical cleaning - Fig. 11 To ensure optimal operation and performance for a long time it is essential to periodically clean the parts subject to dust and grease deposits. The frequency with which the following operations are to be carried out depends on various factors, such as the amount of the effects and the quality of the working environment (air humidity, presence of dust, salinity, etc.). Use a soft cloth dampened with any detergent liquid for cleaning glass to remove the dirt from the reflectors, from the lenses and filters. It is recommended that the projector undergoes an annual service by a qualified technician for special maintenance involving at least the following operations:
• General cleaning of internal parts.
• Restoring lubrication of all parts subject to friction, using lubricants specifically supplied by Clay Paky.
• General visual check of the internal components, cabling, mechanical parts, etc.
• Electrical, photometric and functional checks; eventual repairs.
Continue
WARNING: The best way to clean the surface is to pour ethanol on all the surface with a wash bottle for example and then dry with compressed air. You can also clean with a soaked soft cloth for more stubborn stains. If you don’t have ethanol use a soft glass cleaner.
20
SPHERISCAN - SPHERILIGHT
2
1
1
2
Cleaning of the filters - Fig. 12.
2
1
21
SPHERISCAN - SPHERILIGHT
1
3
A
A
A
2
1
3
14
Opening and closing lamp compartment - Fig. 13
Lamp change - Fig 14
Take the new lamp out of its package and insert in the fitting.
WARNING: do not touch the lamp’s envelope with bare hands. Should this happen, clean the bulb with a cloth soaked in alcohol and dry it with a clean, dry cloth.
CAUTION: Fast lamp ON-OFF cycles (for example 10 minutes ON / 10 minutes OFF) will reduce the lamp life.
Continue
16
Rotating gobo wheel - Fig. 16. ATTENTION:
- Before use custom gobos contact Clay Paky;
- The original gobos have a special coating designed specifically to resist to the high temperatures;
- The rotating gobo wheel only use dichroic glass gobos (it is not possible to use metal gobos);
- For more information contact Clay Paky.
22
SPHERISCAN - SPHERILIGHT
Replacing fuse - Fig. 15
3
2
1
Fuse 6,3 x 32mm 10AT (030470)
1
5
23
SPHERISCAN - SPHERILIGHT
Installation under the stage - Fig. 17. To install the projector under the stage, it is suggested to remove the main bracket and mount the two handles (part number C21090) that allow you to drop easily the projector.
2
1
1
3
3
4
4
ø
1
0
(
0
.
3
9
"
)
522 ±0,5
(20.55")
470
(18.50")
80
(3.15")
390
(15.35")
550
(21.65")
162 ±0,3
(6.38")
R
20
(
0.79")
5
6
R
195
(
7.68"
)
450
(17.72")
C21090
1
7
Continue
24
SPHERISCAN - SPHERILIGHT
How to fit the fans covers - Fig. 18. Depending on how the projector is installed, the covers fan must be positioned so that in case of rain, the water flows in the correct way.
0° ÷ +45°
0° ÷ -45°
1
180°
2
180°
180°
180°
3
2
3
180°
3
1
8
25
SPHERISCAN - SPHERILIGHT
1
6
3
4
5
2
1
9
Battery removal - Fig. 19
This product contains a rechargeable lithium iron tetraphosphate battery. To preserve the environment, please dispose the battery at the end of its life according to the regulation in force.
LiFePO4
Continue
26
SPHERISCAN - SPHERILIGHT
TECHNICAL INFORMATION
4
97
(19.57")
4
15
(
16.34")
358
(
14.09")
886
(
34.88")
498
(19.61")
4
15
(
16.34")
550
(21.65")
5
22
(20.55")
386
(15.20")
1
62
(6.38")
ø
11
(0.
43"
)
512
(
20.16")
374
(
14.72")
886
(
34.88")
198
(7.80")
1
84
(7.24")
300
(11.81")
184
(7.24")
1
98
(7.80")
Power supplies:
200/240V 50/60 Hz
Input power:
1600VA
Total lumen output:
20.000lm @ 1200W
Light source:
Lamp OSRAM Lok-it 1400-PS Color Temperature: 6.000 K
- Life: 750 hrs
- CRI 95
- Luminoux flux: 120000 lm
- Base PGJ28 Lok-it!
Motors: 25 stepper motors, operating with microsteps, totally microprocessor controlled
Inputs:
• DMX 512
• ART-NET
Moving mirror:
PAN Angle Rotation: 360° continuos rotation
TILT Angle Rotation: 60°
Weight: 35 Kg (77 lbs), 32 Kg (70.5 lbs) without bracket
Dimensions:
• (L x W x H): 370 x 390 x 885 mm – with bracket: 485 x 500 x 885 mm
• (L x W x H): 14.56 x 15.35 x 34.84 inches – with bracket: 19.09 x 19.68 x 34.84 inches
IP rating:
• IP54
• Totally protected against the entry of solid bodies
• Protected against splashing of water
Safety devices:
Automatic break in power supply in case of overheating or failed operation of cooling system
Cooling: Forced ventilation with fans
Body:
• Aluminium and steel structure with plastic cover
• Circular handle and moving bracket for transportation
Working position:
• Vertical or orizontal ±45° Working Position to ensure IP54
• Hanging system: with fast-lock omega clamps (1/4 turn) on bracket
Effects section:
• Lamp OSRAM Lok-it 1400-PS works at 1200 W
• Very precise 0-100% dimmer
• CMY System + Linear CTO
• Fast stop/strobe effect
• N°1 Colour Wheel with 7 color filter
• N° 2 Wheels with 6+6 rotating gobo (image ø26 mm)
• N° 1 Graphics Wheel (Interchangeable with fixed gobo Wheel)
• N° 1 16 fast Iris (16 blades)
• N° 1 Rotating Prism with 4 faces
• N° linear Frost (heavy)
• 13° - 34° Optical Zoom (Diameter front lens ø80 mm)
Control and programming:
• DMX protocol signal: USITT DMX 512
• Display: LCD 128 x 64 bit, backlit LED, white on black
• Pan and Tilt Resolution: 16 bit
• Focus Indexing Resolution: 16 bit
• Dimmer Resolution: 16 bit
• Rotation gobo Resolution: 16 bit
• Movement control: vectorial
• DMX signal connection: 5 pole XLR input and output
• Software upload through DMX input / Ethernet input
Electronics:
• Long life self-charging buffer battery.
• Function reset from control unit
• ON/OFF lamp control from the lighting desk.
• Function reset from the lighting desk.
• "AUTOTEST" function from menu.
• ARTNET
• Electronic monitoring with status error.
• Cooling system monitoring.
• DMX level monitoring on all channels.
• Internal data transmission diagnostics.
• Firmware Upgrade with no power.
• Firmware upload from another fixture.
27
SPHERISCAN - SPHERILIGHT
CAUSE AND SOLUTION OF PROBLEMS
THE PROJECTOR WILL NOT SWITCH ON
PROBLEMS
ELECTRONICS NON-OPERATIONAL
DEFECTIVE PROJECTION
REDUCED LUMINOSITY
POSSIBLE CAUSES CHECKS AND REMEDIES
No mains supply. Lamp exhausted or defective. Signal transmission cable faulty or disconnected. Incorrect addressing. Fault in the electronic circuits. Lenses or reflector broken Dust or grease deposited.
Check the power supply voltage. Replace the lamp. (See instructions). Replace the cables. Check addresses (see instructions). Call an authorised technician. Call an authorised technician. Clean (see instructions).
SPHERISCAN
CHANNEL FUNCTION
28
SPHERISCAN - SPHERILIGHT
NB: To prevent accidental breakage of the effects, which could collide with each other during transport, before switching the projector OFF check that all the projector Channels have been excluded (DMX level = 0%).
CHANNEL
CHANNEL MODE
STANDARD VECTOR
1 CYAN CYAN 2 MAGENTA MAGENTA 3 YELLOW YELLOW 4 COLOUR COLOUR 5 STOPPER / STROBE STOPPER / STROBE 6 DIMMER DIMMER 7 FINE DIMMER FINE DIMMER 8 IRIS IRIS
9 STATIC GOBO CHANGE STATIC GOBO CHANGE 10 ROTATING GOBO CHANGE ROTATING GOBO CHANGE 11 GOBO ROTATION GOBO ROTATION 12 FINE GOBO ROTATION FINE GOBO ROTATION 13 PRISM INSERTION PRISM INSERTION 14 PRISM ROTATION PRISM ROTATION 15 FROST FROST 16 ZOOM ZOOM 17 FOCUS FOCUS 18 FINE FOCUS FINE FOCUS 19 FUNCTION FUNCTION 20 RESET RESET 21 LAMP CONTROL LAMP CONTROL 22 PAN PAN 23 FINE PAN FINE PAN 24 PAN MIRROR ROTATION PAN MIRROR ROTATION 25 TILT TILT 26 FINE TILT FINE TILT 27 STRIP LED RED STRIP LED RED 28 STRIP LED GREEN STRIP LED GREEN 29 STRIP LED BLUE STRIP LED BLUE 30 - PAN/TILT TIME 31 - COLOUR TIME 32 - BEAM TIME 33 - ROTATING GOBO TIME
SPHERISCAN - SPHERILIGHT
29
C
hannel Mode
DMX
Value
Function
Standard Vector
1 1
CYAN
0 - 255 Linear Cyan movement
2 2
MAGENTA
0 - 255 Linear Magenta movement
3 3
YELLOW
0 - 255 Linear Yellow movement
4 4
COLOUR
0 - 15 Color 1 16 - 31 Color 2 32 - 47 Color 3 48 - 63 Color 4 64 - 79 Color 5 80 - 95 Color 6
96 - 111 Color 7
112 - 127 Color 8
128 - 255
Continuous rotation at linearly variable speed from Slow (4.4 rph) to Fast (160 rpm)
5 5
STOPPER / STROBE
0 - 3 Light OFF
4 - 103
Strobe at linearly variable frequency from low (1 flash/sec) to high (12 flashes/sec)
104 - 107 Light ON
108 - 207
Pulsation at linearly variable speed
from slow to fast 208 - 212 Light ON 213 - 225 Random Strobe at low frequency 226 - 238 Random Strobe at medium frequency 239 - 251 Random Strobe at high frequency 252 - 255 Light ON
6 6
DIMMER
0 - 255
Light output linearly increase from no-light to maximum brightness.
Dimmer blades move from totally closed to totally open in xxx seconds
at maximum speed.
7 7
DIMMER FINE
0 - 255 Fine Dimmer positioning
8 8
IRIS
0 - 127 Iris linearly open from minimum to maximum aperture 128 - 131 Maximum aperture 132 - 171 Iris pulsation from slow to fast speed 172 - 211 Iris pulsation from slow to fast speed with fast opening 212 - 251 Iris pulsation from slow to fast speed with fast closing 252 - 255 Maximum aperture
Continue
30
SPHERISCAN - SPHERILIGHT
Channel Mode
DMX
Value
Function
Standard Vector
9 9
S
TATIC GOBO CHANGE
0 - 7 Empty position
8 - 15 Gobo 1 16 - 23 Gobo 2 24 - 31 Gobo 3 32 - 39 Gobo 4 40 - 47 Gobo 5 48 - 55 Gobo 6 56 - 63 Gobo 7 64 - 71 Gobo 8
72 - 113
Continuous gobo wheel clockwise rotation at linearly variable speed from fast (60 rpm) to slow (5 rpm)
114 - 117 Stop rotation
118 - 159
Continuous gobo wheel counter-clockwise rotation at linearly variable
speed from slow (5 rpm) to fast (60 rpm) 160 - 171 Gobo 1 shakes at variable speed from slow (24 bpm) to fast (600 bpm) 172 - 183 Gobo 2 shakes at variable speed from slow (24 bpm) to fast (600 bpm) 184 - 195 Gobo 3 shakes at variable speed from slow (24 bpm) to fast (600 bpm) 196 - 207 Gobo 4 shakes … 208 - 219 Gobo 5 shakes … 220 - 231 Gobo 6 shakes … 232 - 243 Gobo 7 shakes … 244 - 245 Gobo 8 shakes …
10 10
ROTATING GOBO CHANGE
0 - 18 Empty position 19 - 37 Gobo 1 38 - 56 Gobo 2 57 - 74 Gobo 3 75 - 92 Gobo 4
93 - 111 Gobo 5 112 - 129 Gobo 6 130 - 150 Gobo 1 shakes at variable speed from slow (xx bpm) to fast (xx bpm) 151 - 171 Gobo 2 shakes at variable speed from slow (xx bpm) to fast (xx bpm) 172 - 192 Gobo 3 shakes at variable speed from slow (xx bpm) to fast (xx bpm) 193 - 213 Gobo 4 shakes at variable speed from slow (xx bpm) to fast (xx bpm) 214 - 234 Gobo 5 shakes at variable speed from slow (xx bpm) to fast (xx bpm) 235 - 255 Gobo 6 shakes at variable speed from slow (xx bpm) to fast (xx bpm)
31
SPHERISCAN - SPHERILIGHT
C
hannel Mode
D
MX
V
alue
F
unction
S
tandard Vector
11 11
GOBO ROTATION
0 - 21 Gobo indexing: 0° to 90° range 21 - 42 Gobo indexing: 90° to 180° range 42 - 63 Gobo indexing: 180° to 270° range 6
3 - 84 Gobo indexing: 270° to 360° range
84 - 105 Gobo indexing: 360° to 450° range
105 - 127 Gobo indexing: 450° to 540° range
128 - 190
Continuous gobo rotation at linearly variable speed from fast (180 rpm) to slow (2.2 rph)
191 - 192 Stop rotation
193 - 255
Continuous gobo rotation at linearly variable speed from slow (2.2 rpm) to fast (180 rpm)
12 12
FINE GOBO ROTATION
0 - 255 Fine Gobo Indexing
13 13
PRISM INSERTION
0 - 127 Prism out
128 - 255 Prism into the light beam
14 14
PRISM ROTATION
0 - 21 Prism indexing: 0° to 90° range 21 - 42 Prism indexing: 90° to 180° range 42 - 63 Prism indexing: 180° to 270° range 63 - 84 Prism indexing: 270° to 360° range
84 - 105 Prism indexing: 360° to 450° range
105 - 127 Prism indexing: 450° to 540° range
128 - 190
Continuous prism rotation at linearly variable speed from fast (80 rpm) to slow (3 rph)
191 - 192 Stop rotation
193 - 255
Continuous prism rotation at linearly variable speed from slow (3 rph) to fast (80 rpm)
15 15
FROST
0 - 255
Frost moves linearly into the light beam Frost blades move from no-diffusion to maximum diffusion
16 16
ZOOM
0 - 255 Zoom linearly moves from narrow to wide beam
17 17
FOCUS
0 - 255 Focus moves linearly from far to near position
18 18
FINE FOCUS
0 - 255 Fine Focus positioning
Continue
32
SPHERISCAN - SPHERILIGHT
Channel Mode
DMX
Value
Function
Standard Vector
19 19
F
UNCTION
0 - 11 Unused range 12 - 24 Fast Pan / Tilt Speed (default) 25 - 37 Normal Pan / Tilt Speed 38 - 50 Conventional Dimmer curve 51 - 62 Linear Dimmer curve (default)
63 -113 Free 114 - 127 Free 128 - 140 Standard Dimmer curve 141 - 152 Fast Gobo change 153 - 163 Normal Gobo change (default) 164 - 255 Free
The functions are activated/selected passing through the unused levels range and staying in the necessary range for 5 seconds
20 20
RESET
0 - 25 Unused range
26 - 76
Zoom Reset
Zoom Reset sequence is activated passing through the unused levels range and staying in this range for 5 seconds
77 - 127
Pan / Tilt Reset
Pan/Tilt Reset sequence passing through the unused levels range and staying in this range for 5 seconds
128 - 255
Complete Reset
All-effects Reset sequence passing through the unused levels range and staying in this range for 5 seconds
21 21
LAMP CONTROL
0 - 25 Unused range
26 - 100
Lamp OFF Lamp switch-off passing through the unused levels range and staying in this range for 5 seconds
101 - 255
Lamp ON Lamp switch-on passing through the unused levels range and staying in this range for 5 seconds.
22 22
PAN
0 - 255 Pan Mirror movement/positioning from 0° to 360°
23 23
FINE PAN
0 - 255 Fine Pan positioning
24 24
PAN MIRROR ROTATION
0 Stop rotation
1 - 126 Mirror counter-clockwise rotation 127 - 129 Stop rotation 130 - 255 Mirror clockwise rotation
25 25
TILT
0 - 255 Tilt movement/positioning
26 26
FINE TILT
0 - 255 Fine Tilt positioning
33
SPHERISCAN - SPHERILIGHT
C
hannel Mode
D
MX
V
alue
F
unction
S
tandard Vector
27 27
STRIP LED RED
0 Led OFF
1 - 255 Led light linearly increase from low to maximum intensity
28 28
STRIP LED GREEN
0 Led OFF
1 - 255 Led light linearly increase from low to maximum intensity
29 29
STRIP LED BLUE
0 Led OFF
1 - 255 Led light linearly increase from low to maximum intensity
-
30
PAN-TILT TIME
0 - 255 Pan - Fine Pan - Tilt - Fine Tilt
-
31
COLOUR TIME
0 - 255 Cyan - Magenta –Yellow
-
32
BEAM TIME
0 - 255 Dimmer - Frost - Prism –Focus - Zoom
-
33
GOBO TIME
0 - 255 Rotating Gobo
Continue
34
SPHERISCAN - SPHERILIGHT
SPHERILIGHT
CHANNEL
CHANNEL MODE
STANDARD VECTOR
1 CYAN CYAN 2 MAGENTA MAGENTA 3 YELLOW YELLOW 4 COLOUR COLOUR 5 STOPPER / STROBE STOPPER / STROBE 6 DIMMER DIMMER 7 FINE DIMMER FINE DIMMER 8 IRIS IRIS
9 STATIC GOBO CHANGE STATIC GOBO CHANGE 10 ROTATING GOBO CHANGE ROTATING GOBO CHANGE 11 GOBO ROTATION GOBO ROTATION 12 FINE GOBO ROTATION FINE GOBO ROTATION 13 PRISM INSERTION PRISM INSERTION 14 PRISM ROTATION PRISM ROTATION 15 FROST FROST 16 ZOOM ZOOM 17 FOCUS FOCUS 18 FINE FOCUS FINE FOCUS 19 FUNCTION FUNCTION 20 RESET RESET 21 LAMP CONTROL LAMP CONTROL 22 - COLOUR TIME 23 - BEAM TIME 24 - ROTATING GOBO TIME
35
SPHERISCAN - SPHERILIGHT
C
hannel Mode
DMX
Value
Function
Standard Vector
1 1
CYAN
0 - 255 Linear Cyan movement
2 2
MAGENTA
0 - 255 Linear Magenta movement
3 3
YELLOW
0 - 255 Linear Yellow movement
4 4
COLOUR
0 - 15 Color 1 16 - 31 Color 2 32 - 47 Color 3 48 - 63 Color 4 64 - 79 Color 5 80 - 95 Color 6
96 - 111 Color 7
112 - 127 Color 8
128 - 255
Continuous rotation at linearly variable speed from Slow (4.4 rph) to Fast (160 rpm)
5 5
STOPPER / STROBE
0 - 3 Light OFF
4 - 103
Strobe at linearly variable frequency from low (1 flash/sec) to high (12 flashes/sec)
104 - 107 Light ON
108 - 207
Pulsation at linearly variable speed
from slow to fast 208 - 212 Light ON 213 - 225 Random Strobe at low frequency 226 - 238 Random Strobe at medium frequency 239 - 251 Random Strobe at high frequency 252 - 255 Light ON
6 6
DIMMER
0 - 255
Light output linearly increase from no-light to maximum brightness.
Dimmer blades move from totally closed to totally open in xxx seconds
at maximum speed.
7 7
FINE DIMMER
0 - 255 Fine Dimmer positioning
8 8
IRIS
0 - 127 Iris linearly open from minimum to maximum aperture 128 - 131 Maximum aperture 132 - 171 Iris pulsation from slow to fast speed 172 - 211 Iris pulsation from slow to fast speed with fast opening 212 - 251 Iris pulsation from slow to fast speed with fast closing 252 - 255 Maximum aperture
Continue
36
SPHERISCAN - SPHERILIGHT
C
hannel Mode
D
MX
V
alue
F
unction
S
tandard Vector
9 9
STATIC GOBO CHANGE
0 - 7 Empty position
8 - 15 Gobo 1 16 - 23 Gobo 2 24 - 31 Gobo 3 32 - 39 Gobo 4 40 - 47 Gobo 5 48 - 55 Gobo 6 56 - 63 Gobo 7 64 - 71 Gobo 8
72 - 113
Continuous gobo wheel clockwise rotation at linearly variable speed from fast (60 rpm) to slow (5 rpm)
114 - 117 Stop rotation
118 - 159
Continuous gobo wheel counter-clockwise rotation at linearly variable
speed from slow (5 rpm) to fast (60 rpm) 160 - 171 Gobo 1 shakes at variable speed from slow (24 bpm) to fast (600 bpm) 172 - 183 Gobo 2 shakes at variable speed from slow (24 bpm) to fast (600 bpm) 184 - 195 Gobo 3 shakes at variable speed from slow (24 bpm) to fast (600 bpm) 196 - 207 Gobo 4 shakes … 208 - 219 Gobo 5 shakes … 220 - 231 Gobo 6 shakes … 232 - 243 Gobo 7 shakes … 244 - 245 Gobo 8 shakes …
10 10
ROTATING GOBO CHANGE
0 - 18 Empty position 19 - 37 Gobo 1 38 - 56 Gobo 2 57 - 74 Gobo 3 75 - 92 Gobo 4
93 - 111 Gobo 5 112 - 129 Gobo 6 130 - 150 Gobo 1 shakes at variable speed from slow (xx bpm) to fast (xx bpm) 151 - 171 Gobo 2 shakes at variable speed from slow (xx bpm) to fast (xx bpm) 172 - 192 Gobo 3 shakes at variable speed from slow (xx bpm) to fast (xx bpm) 193 - 213 Gobo 4 shakes at variable speed from slow (xx bpm) to fast (xx bpm) 214 - 234 Gobo 5 shakes at variable speed from slow (xx bpm) to fast (xx bpm) 235 - 255 Gobo 6 shakes at variable speed from slow (xx bpm) to fast (xx bpm)
11 11
GOBO ROTATION
0 - 21 Gobo indexing: 0° to 90° range 21 - 42 Gobo indexing: 90° to 180° range 42 - 63 Gobo indexing: 180° to 270° range 63 - 84 Gobo indexing: 270° to 360° range
84 - 105 Gobo indexing: 360° to 450° range
105 - 127 Gobo indexing: 450° to 540° range
128 - 190
Continuous gobo rotation at linearly variable speed from fast (180 rpm) to slow (2.2 rph)
191 - 192 Stop rotation
193 - 255
Continuous gobo rotation at linearly variable speed from slow (2.2 rph) to fast (180 rpm)
12 12
FINE GOBO ROTATION
0 - 255 Fine Gobo Indexing
37
SPHERISCAN - SPHERILIGHT
Channel Mode
DMX
Value
Function
S
tandard Vector
13 13
PRISM INSERTION
0 - 127 Prism out
128 - 255 Prism into the light beam
14 14
PRISM ROTATION
0 - 21 Prism indexing: 0° to 90° range 21 - 42 Prism indexing: 90° to 180° range 42 - 63 Prism indexing: 180° to 270° range 63 - 84 Prism indexing: 270° to 360° range
84 - 105 Prism indexing: 360° to 450° range
105 - 127 Prism indexing: 450° to 540° range
128 - 190
Continuous prism rotation at linearly variable speed from fast (80 rpm) to slow (3 rph)
191 - 192 Stop rotation
193 - 255
Continuous prism rotation at linearly variable speed from slow (3 rph) to fast (80 rpm)
15 15
FROST
0 - 255
Frost moves linearly into the light beam Frost blades move from no-diffusion to maximum diffusion
16 16
ZOOM
0 - 255 Zoom linearly moves from narrow to wide beam
17 17
FOCUS
0 - 255 Focus moves linearly from far to near position
18 18
FINE FOCUS
0 - 255 Fine Focus positioning
19 19
FUNCTION
0 - 11 Unused range 12 - 24 Fast Pan/ Tilt Speed (default) 25 - 37 Normal Pan / Tilt Speed 38 - 50 Conventional Dimmer curve 51 - 62 Linear Dimmer curve (default)
63 -113 Free 114 - 127 Free 128 - 140 Standard Dimmer curve 141 - 152 Fast Gobo change 153 - 163 Normal Gobo change (default) 164 - 255 Free
The functions are activated/selected passing through the unused levels range and staying in the necessary range for 5 seconds
20 20
RESET
0 - 25 Unused range
26 - 76
Zoom Reset
Zoom Reset sequence is activated passing through the unused levels range and staying in this range for 5 seconds
77 - 127
Pan / Tilt Reset
Pan/Tilt Reset sequence passing through the unused levels range and staying in this range for 5 seconds
128 - 255
Complete Reset
All-effects Reset sequence passing through the unused levels range and staying in this range for 5 seconds
Continue
38
SPHERISCAN - SPHERILIGHT
C
hannel Mode
D
MX
V
alue
F
unction
S
tandard Vector
21 21
LAMP CONTROL
0 - 25 Unused range
26 - 100
Lamp OFF Lamp switch-off passing through the unused levels range and staying in this range for 5 seconds
101 - 255
Lamp ON Lamp switch-on passing through the unused levels range and staying in this range for 5 seconds.
-
22
COLOUR TIME
0 - 255 Cyan - Magenta –Yellow
-
23
BEAM TIME
0 - 255 Dimmer - Frost - Prism –Focus - Zoom
-
24
GOBO TIME
0 - 255 Rotating Gobo
39
SPHERISCAN - SPHERILIGHT
BIT Seconds
0 Full
1 0.2 2 0.4 3 0.6
4 0.8 5 1 6 1.2 7 1.4 8 1.6 9 1.8 10 2 11 2.2 12 2.4 13 2.6 14 2.8 15 3 16 3.2 17 3.4 18 3.6 19 3.8 20 4 21 4.2 22 4.4 23 4.6 24 4.8 25 5 26 5.2 27 5.4 28 5.6 29 5.8 30 6 31 6.2 32 6.4 33 6.6 34 6.8 35 7 36 7.2 37 7.4 38 7.6 39 7.8 40 8 41 8.2 42 8.4
BIT Seconds
43 8.6
44 8.8 45 9 46 9.2
47 9.4 48 9.6 49 9.8 50 10 51 10.2 52 10.4 53 10.6 54
11
55 56
12
57 58
13
59 60 61 14 62 63
15
64 65 66 16 67 68
17
69 70 71 18 72 73
19
74 75 76 20 77 78 79 21 80 81
22
82 83 84 23 85
BIT Seconds
86
24
87 88 89 25
90 91
26
92 93 94 27 95 96
28
97 98 99 29 100 101 102 30 103 104
31
105 106 107 32 108 109
33
110 111 112 34 113 114
35
115 116 117 36 118 119
37
120 121 122 38 123 124 125 39 126 127
40
128
BIT Seconds
129
130 41 131 132
4
2
133 134 135 43 136 137
44
138 139 140 45 141 142
46
143 144 145 47 146 147
48
148 149 150 49 151 152 153 50 154 155
51
156 157 158 52 159 160
53
161 162 163 54 164 165
55
166 167 168 56 169 170
57
171
BIT Seconds
172 173 58 174 175 176 59 177 178
6
0
179 180 181 65 182 183
70
184 185 186 75 187 188
80
189 190 191 85 192 193
90
194 195 196 95 197 198
100
199 200 201 110 202 203 204 120 205 206
130
207 208 209 140 210 211
150
212 213 214 160 215
BIT Seconds
216
170
217 218 219 180
220 221
190
222 223 224 200 225 226 227 210 228 229
220
230 231 232 230 233 234
240
235 236 237 250 238 239
260
240 241 242 270 243 244
280
245 246 247 290 248 249
300
250 251 252
310
253 254
255
Follow cue
Data
TIME TABLE
CLAY PAKY S.p.A. - Via Pastrengo, 3/b - 24068 Seriate (BG) Italy - Tel. +39-035 -654311 - Fax +39-035-301876 - www.claypaky.it
IST00U/001 – EN - PRELIMINARY - 12/2015
Loading...