MODEL
X105L
X105L2
Limit Switch Assemblies
• UL Listed Switches
• Positive Action
• Rugged and Dependable
• Weather Proof or Explosion Proof
• Easy To Adjust
The Cla-Val Model X105L/X105L2 Limit Switch Assembly is a
rugged, dependable and positive acting switch assembly actuated
by the opening or closing of a Cla-Val control valve on which it is
mounted. The single pole, double throw micro switch can be
connected either to open or to close an electrical circuit when
actuated. By loosening the allen screw on the actuating collar and
raising or lowering the collar on the stem, the X105L is easily
adjusted to signal that the valve has fully reached the desired
position (open or closed).
Installation
Single Pole Double Throw Switch
Double Pole Double Throw Switch
Switches shown in
unactivated position.
Annunciator
Alarm
1. Remove plug in top of
valve cover.
2. Screw actuating stem
into main valve stem.
3. Slip adapter down
over stem and screw
into place on valve
cover.
4. Attach micro switch
housing and bracket to
adapter with jam nut.
5. Bring electrical supply
circuit into unit through
the 1/2" tapping in
micro switch housing.
6. Adjust switch collars.
(Set collar to trip
switch after valve is
positioned fully open
or fully closed)
Typical Application
Used for any electrical operation which can be
performed by either opening or closing a switch;
such as alarm systems, process control, pump
control, motor starting or stopping, etc. Readily
attached to most Cla-Val Valves.
Actuating Collar Adjustment
Minimum Setting
When adjusting actuating collar for proper switch
action, a clearance of at least 1/16" (1/8” for 24”
valve) must be provided between the collar and
the bushing gland nut when valve is in the fully
closed position.
Stem
Switch Actuating Collar
Bushing Gland Nut
Jam Nut
Bracket
Adapter
Min.
1/16"

A
Fig. 1
Valve Size
1 1/4" Thru 8"
X105L2W
X105L2X
1/2-14 N.P.S.M. Thread
(Conduit Connections)
.13
2.44
1.70
3.00
.86
3.13
2.00
C (Typical)
Fig. 3
Fig. 2
A
Valve Size
1 1/4" Thru 24"
X105LCW
A
X105LCX
Fig. 4
Valve Size
10" Thru 24"
A
B
X105LOW
X105LOX
A
B
Valve Size
1 1/4" Thru 8"
X105LOW
X105LOX
Fig. 5
Valve Size
10" Thru 24"
X105L2W
X105L2X
X105 Series Dimensions
BasicValve 100-01 1 1⁄4 1 1⁄2 2 2 1⁄2 3 4 6 8 10 12 14 16 18 20 24 30 36* 42* 48*
Dimension "A" 10.19 10.19 7.16 7.16 7.34 7.00 6.69 6.91 9.88 9.59 9.16 10.78 10.78 CF* 11.30 CF* CF* CF* CF*
Dimension "B" 1.69 2.44 2.94 2.94 2.94 2.94 CF* 5.19 CF* CF* CF* CF*
C (NPT) 1/4 1/4 1/2 1/2 1/2 3/4 3/4 1 1 1 1/4 1 1/2 2 2 CF* 1CF*CF* CF* CF*
BasicValve 100-20 3 4 6 8 10 12 14 16 18 20 24 30 36* 42* 48*
Dimension "A" 7.16 7.34 7.00 6.69 6.91 9.88 9.59 9.59 10.78 10.78 10.78 11.30 CF* CF* CF*
Dimension "B" 1.69 2.44 2.94 2.94 2.94 2.94 2.94 5.19 CF* CF* CF*
C (NPT) 1/2 1/2 3/4 3/4 1 1 1 1/4 1 1/4 2 2 2 1 CF* CF* CF*
Specifications
Materials: Aluminum switch housing
Electrical: 1/2" Conduit connection
Switch Type: SPDT UL, File No. E12252,
Switch Rating: UL/CSA rating: L96
Switch Options: DPDT switches available on request
E-X105L/X105L2 (R-3/2011)
Steel bracket and brass adapter
Stainless steel stem
CSA Certified, File No. LR57325
Weather proof
NEMA 1,3,4, and13
15 amp. 125, 250, or 480 volts AC
1/2 amp. 125 volts DC
1/4 amp. 250 volts DC
UL/CSA Rating: L59, 10 amps
Explosion proof micro switches are
NEMA 1,7, and 9
UL Listed, File No. E14274 and CSA
Certified, File No. LR57324: Class I,
Group C and D and Class II, Group
E, F and G.
PO Box 1325 Newport Beach CA 92659-0325
Phone: 949-722-4800 Fax: 949-548-5441
CLA-VAL CANADA CLA-VAL EUROPE
4687 Christie Drive
Beamsville, Ontario
Canada L0R 1B4
Phone: 905-563-4963
Fax: 905-563-4040
©COPYRIGHT CLA-VAL 2011 Printed in USA
Specifications subject to change without notice.
(In Inches)
LA-VAL
Chemin dés Mesanges 1
CH-1032 Romanel/
Lausanne, Switzerland
Phone: 41-21-643-15-55
Fax: 41-21-643-15-50
www.cla-val.com
When Ordering, Please Specify
1. Valve Size and Basic Valve Model Number
2. Catalog Number from Table Below
3. All Valve Name Plate Data
4. Select Single or Double Pole Switch
CATALOG ACTUATION SWITCH
NO. POSITION ENCLOSURE
X105LCW Valve Weather Proof
Closed
X105LCX Valve Explosion Proof
Closed
X105LOW Valve Weather Proof
Open
X105LOX Valve Explosion Proof
Open
X105L2W Dual Weather Proof
X105L2X Dual Explosion Proof
*Consult Factory
5. Explosion Proof or Weather
Proof Type Enclosure
6. Amperes and Voltage, AC or DC
7. Actuating Position (Valve Open or Closed)