Cla-Val X101AR User Manual

Page 1
X101AR
CLA-VAL
Copyright Cla-Val 2013 Printed in USA Specifications subject to change without notice.
P.O. Box 1325 Newport Beach, CA 92659-0325 Phone: 949-722-4800 Fax: 949-548-5441 E-mail: claval@cla-val.com Website cla-val.com
©
Valve Position Indicator with Air Release Valve
Air Bleed
Screw
Air Release Valve
Indicator
Housing
Installation
The Model X101AR Valve Position Indicator with Air Release Valve can be installed on any Cla-Val basic main valve in a matter of minutes. Simply remove the fitting on top of the valve, thread in the X101AR stem to the main valve stem, then thread the indicator housing onto the main valve cover.
For automatic air release operation, unscrew air bleed screw at least one turn off of seat.
The air release valve cannot be retrofitted to an existing X101 Valve Position Indicator.
• Automatically Relieves Air in Cover Chamber
• Positive Visual Valve Position Indicator
• Maximum Pressure 225 psi
• Stainless Steel Construction
Specifications
Sizes: 1" thru 16; Consult Factory for larger sizes
Materials: Stainless Steel, Pyrex Tube
Pressure Rating: 225 psi
Max Temperature: 180
Internal
3.15”
“A” Ma x
Float
F
°
Air Bleed Screw
Air Release Valve
Indicator Housing
Valve
Size (Inches)
1
1-1/4
1-1/2
2
3
4
6
8
10
“A” Max
Inches
8-1/2
8-1/2
8-1/2
10
10
11-1/2
13-1/2
9
9
When Ordering, Please Specify
1. Valve Size
2. Catalog No. X101AR
3. Valve Series No. (Appears on Valve Nameplate)
12
Valve Cover
Stem
14
16
E-X101AR (R-10/2013)
16-1/2
14
N/A
Loading...