Electronic Valve Controller
M
e
t
e
r
i
n
g
V
a
l
v
e
s
E
l
e
c
t
r
o
n
i
c
a
l
l
y
A
c
t
u
a
t
e
d
H
y
d
r
a
u
l
i
c
V
a
l
v
e
s
E
l
e
c
t
r
o
n
i
c
D
u
a
l
S
o
l
e
n
o
i
d
V
a
l
v
e
s
C
u
s
t
o
m
A
p
p
l
i
c
a
t
i
o
n
s
Tailored to unique
requirements, such as:
• Pump Control
• Surge Control
• Position Control
300 Series
133 Series
131 Series
Model VC-22D Valve Controller
Product Description
The Cla-Val Model VC-22D is a controller designed to
enable remote control of electronic valves in water
plant or distribution systems. It also serves as an
interface between a SCADA system and other devices
installed on or around the valve (such as a meter).
For ease of use, the controller is pre-loaded with a
wide variety of typical valve applications
(ValvApps™). Additional custom ValvApps™ can be
created by Cla-Val to meet any operational
requirement.
MODEL
VC-22D
• Provides remote or local set-point control for valves in a
variety of fluid applications
• Highly accurate and stable valve control
• IP-68 Submersible
• Controller is supplied with pre-loaded ValvApps™ for
most common valve functions
• Custom ValvApps™ can be created using Valve Functions
to meet unique application requirements
• Custom ValveApps can be pre-loaded prior to shipping
• Monitors and displays multiple processes with accurate
retransmission of parameters to SCADA systems
• Supplied with Standard Alarm Outputs
• Logging capabilities
• Low power consumption: less than 3 watts
Controller Applications
Pre-Loaded Typical ValvApps™ include:
• Flow Control with Mag Meter or e-Flowmeter
• Pressure Control with Upstream or Downstream
• Position Control with Position Feedback
• Modulating Level Control with Level and Position
• Metering Valve with Position and DP or P1-P2
• Ratio Control with 2 Flowmeter feedbacks
• Altitude On/Off Level Control with Delayed
• Pressure Management with CRD-33 and Flow
Feedback
Feedback
or Flow Feedback
Feedback
Opening and Level Feedback
Feedback
E-VC-22D (R07/2014)

VALVE FUNCTIONS
PID Control
Used in maintaining a control valve at setpoint.
Uses a graphical function, allowing the user
to make different signal types (for example:
flow and pressure). The user also has the ability
to make relationships as a function of time.
This is the primary function employed in pressure
management/water savings applications.
Control Curves
Used to take “action” (or alarms) on an input,
output, or variable when a programmable
condition is met.
Actions
Keeps track of total volume as a function of time.
Customizable units & reset functionality allow for
simplified set-up and configuration.
Totalizer
Used to retransmit any input signal, variable,
or calculation to a SCADA system.
Retransmission outputs include analog 4-20mA
or digital (contact closure).
Retransmission
Used to return an accurate flow rate without
having a flow meter installed. Using a valve
position transmitter & DP transmitter, this
function will calculate flow.
DP Metering
PID
Retrans

05/19/14 12: 00 PM
Flow Meter
Upstream Pressure
70 psi
390-02.v1.0.rdx
1500 gpm
CRD-33
4.00 mA
Downstream Pressure
20 psi
05/19/14 12:00 PM
Setpoint
1000 gpm
Valve Position
50 %
Opening Solenoid
5.0%
Closing Solenoid
0.0%
DP Transmitter
20 psi
133-01.v1.0.rdx
Flow Rate
950 gpm
05/19/14 12:00 PM
Setpoint
1000 gpm
Flow Rate
950 gpm
Opening Solenoid
5.0%
Closing Solenoid
0.0%
131-01_Mag.v1.0.rdx
05/19/14 12:00 PM
Tank Height
10.00 ft
Flow Rate
0 gpm
Opening Solenoid
0.0%
Closing Solenoid
0.0%
131-01_ModLevel_eFlow.v1.0.rdx
ValvApps™
Control with Flow Feedback
Required Functions:
• Remote & local setpoint capabilities
PID
• Universal control of any process, such
as flow
Optional Functions:
w Rate
Retrans
Tank Heig
1010.0.00 0
Opening Solenoi
Control with Metering Function
Required Functions:
PID
Optional Functions:
• Flow metering control
valve without the use of a
flow meter
• Requires a valve position
transmitter & DP transmitter
Retrans
Required Functions:
Optional Functions:
Modulating Level Cntl
PID
ClosingSoleno
• Flow proportioning level
control
• Programmable tank level
band
Retrans
Water Savings/Pressure Management
Required Functions:
• Flow and/or time-based pressure
management
• Programmable logging capabilities
Optional Functions:
Retrans

SPECIFICATIONS
Component Specification Details
Enclosure
Enclosure Material Flame retardant UL rated PC/ABS plastic
Enclosure Connections
Environmental IP-68, 2 meters for 48 hours
Enclosure Dimensions 8.75” (223 mm) H x 6” (153 mm) W x 3.5” (89 mm) D
Enclosure Weight 3 lbs. (1.37 kg)
Mounting Bracket Anodized Aluminum - Standard
Power 300 mA @ 24VDC (Steady State)
Fuse Type 3A Fuse recommended
Display Type 4.3” Color TFT-LCD, 480 x 272 pixels
Display Update Rate 100ms
Programming Method Mechanical Push Button; VNC
Password 5 digit
Type 2GB SD Card
Language English
Humidity 90% RH, non-condensing
Power Input 12-24VDC – Full Function (standard) or optional power supply
Memory Protection 10-year lithium battery
Configurable Ye s
Logging Speed 1 minute
Output CSV format suitable for exporting to MS Excel
Analog (6) Inputs (4-20mA / 0-5 V / 0-10 V)
Resolution 10 bit
Digital (6) digital inputs (Dry contact)
Units Configurable
Decimal Point 0 / 0.0 / 0.00 / 0.000
Signal Filter Configurable 1 to 60 seconds
Totalizer Configurable input and units
Totalizer Reset Yes
I/O Connection Screw Terminals
Analog (4) Outputs (4-20mA)
Resolution 10 bit
Solenoid (2) Solid State Relay (DC), Zero Switching Voltage • For AC Solenoids, use PC-22D Power Converter
Relay (2) Mechanical Relay, Rated Voltage 250VAC, Rated Current 6A
Control Input 4-20mA full scale / 0-5 V / 0-10V / digital (dry contact
Proportional Band 0-100% (50% default) adjustable in 1% increments • Independently for opening and closing
Dead Band Adjustable 0 to full scale of set-point signal
Cycle Time 0 to 60 seconds in 1 sec. increments
Integral Band Adjustable 0 to 60 seconds
Derivative Band Adjustable 0 to 60 seconds
Loop Zoning Adjustable up to (4) zones
PID Loops 4 Configurable
Working Temperature -10 to 70° C • 14°F to 158°F
Storage Temperature -30 to 85° C • -22°F to 185°F
M16/M20 Cable ; IP-68 Cable Glands
IP-68 USB Type A & Type B Connection, IP-68 Ethernet Port
Power Requirement
Display
Mass Data Storage
Input Logging
Inputs
Outputs
Control Parameters
Temperature Range