ClassicFlame 18E01, 23E02, 33E01, 28E01 Homeowners Operating Manual

CONSUMER SAFETY INFORMATION
PLEASE READ THIS MANUAL BEFORE INSTALLING
AND OPERATING THIS APPLIANCE
WARNING!!
IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY,
AN ELECTRIC SHOCK OR FIRE MAY RESULT CAUSING PROPERTY
DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY
qualified service agency.
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS
AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
Manufactured and Distributed by: Twin-Star International, Inc. Delray Beach, FL 33483 Printed in China www.classicflame.co Made in China
ELECTRIC FIREPLACE INSERT
HOMEOWNERS OPERATING MANUAL
ELECTRIC FIREPLACE INSERTS
MODELS 18E01, 23E02, 28E01 & 33E01
ALSO Requires - Wood Fireplace
Mantel by ClassicFlame
VENT FREE FIREPLACE WITH HEATER
Thank you and congratulations on your purchase of a ClassicFlame™ fireplace. Please read the Installation & Operating Instructions before using this appliance.
IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible electric shock, fire hazard and/or injury and will void the warranty.
ATTENTION
IMPORTANT INSTRUCTIONS
1. Read all instructions before using this appliance.
2. This appliance is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. If provided, use handles when moving this appliance. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes and curtains at least 3 feet (1m) from the front of this appliance.
3. CAUTION: Whenever the heater is left operating and unattended, extreme caution is necessary if children or invalids are nearby.
4. If possible, always unplug this appliance when not in use.
5. Do not operate any heater with a damaged cord or plug or after the appliance malfunctions, or if it has been dropped or damaged in any manner.
6. Any repairs to this fireplace should be carried out by a qualified service person.
7. Under no circumstances should this fireplace be modified. Parts having to be removed for servicing must be replaced prior to operating this fireplace again.
8. Do not use outdoors.
9. This heater is not intended for use in bathrooms, laundry areas and similar indoor locations. Never locate this appliance where it may fall into a bath­tub or other water container.
10. Do not run cord under carpeting. Do not cover cord with throw rugs, runners or the like. Arrange cord away from traffic areas and where it will not be tripped over.
11. To disconnect this appliance, turn controls to the off position, then remove plug from outlet.
12. Connect to properly grounded outlets only.
13. This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code or for U.S.A. installations follow local codes and the National Electrical Code, ANSI/NFPA NO. 70.
14. Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire, or damage the appliance.
15. To prevent a possible fire, do not block air intakes or exhaust in any manner. Do not use on soft surfaces, like a bed, where opening may become blocked.
16. This appliance has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint or flammable liquids are used or stored. This fire­place should not be used as a drying rack for cloth­ing, and Christmas stockings or decorations should not be hung in the area of it.
17. Use this appliance only as described in the manual. Any other use not recommended by the manufacturer may cause fire, electric shock or injury to persons.
18. Avoid the use of an extension cord because the extension cord may overheat and cause a risk of fire. However, if you have to use an extension cord, the cord must be No. 14 AWG minimum size and rated not less than 1875 Watts. The extension cord must be three wire cord with grounding type plug and cord connection. The extension cord shall not be more than 20 feet in length.
19. This heater is for use on 120 volts. The cord has a plug as shown at A. An adapter as shown at C is available for connecting three-blade grounding­type plugs to two-slot receptacles. The green grounding plug extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box. The adapter should not be used if a three-slot grounded receptacle is available.
SAVE THESE INSTRUCTIONS
INSTALLATION INSTRUCTIONS
Position your completed Wood Mantel close to its final location. Make sure you can access the back of the Fireplace, your Electric Fireplace Insert will be installed from the back.
Using a Phillips head screwdriver remove the screws and the mounting brackets attached on either side of the fire­places center opening. Next unpack the Electric Fireplace Insert carefully. Position insert behind fireplace with front facing the wood mantel. With the help of an adult assistant, lift the Insert and gently slide it into the opening in the mantel until the flange is flush against the inside of the fireplace. Make sure insert is centered left and right in the opening. Be careful when placing insert and
adjusting, bottom of insert could scratch the finish of the wood base/hearth of your fire­place. Re-attach the mounting brackets with
the Phillips head screwdriver, and supplied screws. DO NOT OVER TIGHTEN.
With the help of an assistant carefully lift completed unit and place it with the front facing out in the final location you have chosen for your fireplace. Make sure to secure the electrical chord before lifting or moving completed fireplace. When choosing a final location make sure you will have clear access to a grounded electrical outlet.
Read and follow all instructions in this manual before operating your new fireplace.
PARTS LIST
Part Number Description
E200200 . . . . . . . . . . . .Ember Bed/Log Grate/Logs
E200300 . . . . . . . . . . . .1,500 Watt Heater
E200301 . . . . . . . . . . . .Cylindrical Fan
E200400 . . . . . . . . . . . .Master On/Off Switch
E200401 . . . . . . . . . . . .Knob for Brightness Control
E200402 . . . . . . . . . . . .Heater On/Off Switch
E200403 . . . . . . . . . . . .High Heat On/Off switch
E200404 . . . . . . . . . . . .Knob for Heater Temperature Control
E200500 . . . . . . . . . . . .E-12 Light Bulb sockets
E200502 . . . . . . . . . . . .Front Projection Screen
E200503 . . . . . . . . . . . .Frosted Mylar Projection Screen (Rear)
E200504 . . . . . . . . . . . .Sheet metal Flame Cut-out Screen
E200505 . . . . . . . . . . . .Flame Generator/Spinner
E200506 . . . . . . . . . . . .Flame Generator Drive Motor
E200509 . . . . . . . . . . . .Angled Reflection Hood
E200603 . . . . . . . . . . . .Assembly Instructions/Warranty
FIREPLACE
INSERT
BRACKET
FIREPLACE
INSERT
BACK VIEW
Cold climate installation recommendation: When installing this unit against a non-insulated exterior wall or chase, it is mandatory that the outer walls be insulated to conform to applicable insulation codes.
Vo ltage: 120VAC, 60 Hz Total Amps: 12.0 Amps Total Watts: 1500 Watts Heater Rating: 1350 Watts
ELECTRICAL SPECIFICATIONS
A 15 AMP, 120 Volt, 60 Hz circuit with a properly grounded outlet is required. Preferably, the fireplace will be on a dedicated circuit as other appliances on the same circuit may cause the circuit breaker to trip or the fuse to blow when the heater is in operation. The unit comes standard with 6’ (1828 mm) three wire cord,exciting from the rear of the fireplace. Plan the installation to avoid the use of an extension cord. If an extension cord must be used, it must be a minimum 14 AWG, three wire with grounding type plug connec­tor and rated not less than 1875 Watts. The cord shall not be more than 20 feet in length.
ELECTRICAL CONNECTION
CLEANING TRIM
Clean the metal trim using a soft cloth, slightly dampened with a citrus oil based product and buff with a clean soft cloth. DO NOT use brass polish or household cleaners as these products will damage the metal trim. Citrus oil based products can be obtained at supermarkets or hardware stores.
WARNING: Electrical outlet wiring must comply with local building codes and other applicable regulations to reduce the risk of fire, electrical shock and injury to persons.
WARNING: Do not use this fireplace if any part of it has been under water. Immediately call a qualified service tech­nician to inspect the fireplace and replace any part of the electrical system.
Wa r ning: Disconnect power before attempting any maintenance or clean­ing to reduce the risk of fire, electrical shock or personal injury.
When choosing a location for your new fireplace, ensure that the general instructions are followed. Also, for best effect install the fireplace out of direct sunlight.
POSITIONING/LOCATING YOUR
CLASSICFLAME™ ELECTRIC
FIREPLACE
CLEARANCE TO COMBUSTIBLES
MAINTENANCE OF MOTORS
The motors used on the fan and the flame generator assembly are pre-lubricated for extended bearing life and require no further lubrication. However, periodic cleaning/vacuuming of the fan/heater unit is recom­mended. The louvers/vent in the control door should be cleaned periodically, both inside and out. When the control door is in the open position the heater grill/screen should be vacuumed. The area around the controls should also be kept clean. Make sure the unit is turned OFF and unplugged whenever you are clean­ing the heater or fireplace.
WARNING: Make sure the power is turned off before proceeding. Any elec­trical repairs or rewiring of this unit should be carried out by a licensed elec­trician in accordance with national and local codes.
If repairing or replacing any electrical component or wiring, the original wire routing, color coding and securing locations must be followed.
Keep electrical cords, drapery, furniture and other combustibles at least 3 feet(0.9M) from the front of the heater and away from the sides.
REPLACING THE LIGHT
BULBS
This fireplace uses (3) clear 120V, 40 Watt E12 Socket base light bulbs (open small base, chandelier candle type). The 18E01 insert only requires (2) clear 120V, 40 Watt E12 Scoket bulbs, installed in a pull-out tray accessable once the kickplate has been removed. The 40 Watt bulbs are accessed through the front kick plate (see illustration below). For convenience, if a bulb burns out, it is a good idea to replace all of the bulbs at the same time.
1.) Turn the master power switch off, then UNPLUG the power cord from the wall.
2.) If fireplace has been operating, let the unit cool at least 2 hours.
3.) Loosen the 2 screws recessed in the front kick plate (see illustration below). Gently pull the kick plate towards you (careful not to scratch the fireplace hearth/base).
4.) Remove light bulbs and replace with (3) clear 120V, 40 Watt E12 Socket base light bulbs, (2) bulbs for 18E01 Insert, via pull-out tray.
5.) Slide kick plate back into position and tighten recessed screws. (Careful not to over tighten).
WARNING: Do not exceed 40 Watts per bulb. Use of higher rated bulbs may result in a fire, causing property dam­age or personal injury.
OPERATING
INSTRUCTIONS
CONTROL FUNCTIONS
MAIN POWER - The Main Power switch supplies power to all of the functions of the fireplace.
WARNING: During any service of this appliance, the power to the unit must be turned off. First turn the main power switch to the “OFF” position. Then remove the electrical plug from the wall outlet.
HEATER - The Heater switch turns the heater element and blower motor on and off.
DOWN LIGHT (28E01 & 33E01 ONLY) ­The Down Light switch turns on the down lights that illuminate inside of the firebox.
TEMPERATURE - The Temperature control knob regulates the temperature level of the heater. Turning the knob clockwise will increase the heat output. The further the knob is rotated clock-wise, the higher the set point temperature. Turning the knob counter­clock-wise will lower the set point temperature.
FLAME BRIGHTNESS - The Flame Brightness control knob adjusts the flame brightness. Turning the knob to the left dims the lights and flame effect. Tu r ning the knob to the right brightens the lights and flame effect.
3 Switch Control Panel (models 28E01 and 33E01)
2 Switch Control Panel (models 18E01 and 23E02)
1. Lossen reccessed phillips head screw
2. Lossen reccessed phillips head screw
3. Remove Kickplate to Access Lightbulbs
4. Replace all Lightbulbs
BASIC WARRANTY: Tw in-Star International, Inc. (hereinafter referred to collectively as the (“Company”) warrants that your new ClassicFlame™ Electric Fireplace is free from manufacturing and material defects for a period of one year from date of purchase, subject to the follow­ing conditions and limitations.
1. This electric fireplace must be installed and operat-
ed at all times in accordance with the installation and operating instructions furnished with the product. Any unauthorized repair, alteration, will­ful abuse, accident, or misuse of the product shall nullify this warranty.
2. This warranty is non-transferable, and is made to
the original owner, provided that the purchase was made through an authorized supplier of the com­pany.
3. The warranty is limited to the repair or replacement
of part(s) found to be defective in material or workmanship, provided that such part(s) have been subjected to normal conditions of use and service, after said defect is confirmed by the Company’s inspection.
4. This warranty does not cover the light bulb(s)
included with the ClassicFlame™ Electric Fireplace.
5. The Company may, at its discretion, fully discharge
all obligations with respect to this warranty by refunding the wholesale price of the defective part(s).
6. Any installation, labor, construction, transportation,
or other related costs/expenses arising from defec­tive part(s), repair, replacement, or otherwise of same, will not be covered by this warranty, nor shall the Company assume responsibility for same.
7. The owner/user assumes all other risks, if any, including the risk of any direct, indirect or conse­quential loss or damage arising out of the use, or inability to use the product, except as provided by law.
8. All other warranties – expressed of implied – with respect to the product, its components and acces­sories, or any obligations/liabilities on the part of the Company are hereby expressly excluded.
9. The Company neither assumes, nor authorizes any third party to assume, on its behalf, any other lia­bilities with respect to the sale of the ClassicFlame™ product.
10. The warranties as outlined within this document do not apply to non ClassicFlame™ accessories used in conjunction with the installation of this product.
This warranty is void if: a. The fireplace is subjected to prolonged periods of
dampness or condensation.
b. Any unauthorized repair alteration, willful abuse,
accident, or misuse of the product.
c. You do not have the original receipt of purchase.
IF WARRANTY SERVICE IS NEEDED:
1) Contact the Company, at parts@twinstarhome.com,
or 1-866-661-1218. Make sure you have your war­ranty, your sales receipt, and the model/serial num­ber of your ClassicFlame™ product.
2) ANY AND ALL WORK DEEMED NECESSARY
MUST BE PERFORMED BY A REPAIR SPECIAL­IST, DO NOT ATTEMPT TO DO ANY SERVICE WORK YOURSELF.
1 YEAR WARRANTY
For ClassicFlame™ Electric Fireplace Models
Twin-Star International, Inc. • Delray Beach, FL 33483 • 1-866-661-1218 • www.classicflame.com
OPERATING ON/OFF REMOTE
(Remote control is included with some models of the 28E01 and 33E01 electric insert)
1. Plug the receiver into an outlet.
2. Let the switch hand downward so moisture doesn’t accumelate in the outlets.
3. Teh red indicator on the transmitter should light up
when pushing the on or off button down. The red indicator on the receiver should light up when receiver is switched on.
Battery: Replace battery when the red indicator light on remote does not light when a button is pressed.
1. Open battery door.
2. Remove old battery and dispose of properly.
3. Replace with an alkaline battery 23A Rated 12V. MAX LOAD: 125V AC/60Hz 15A / 1875W Resistive, 1000W Tungsten / Tungstene 1/2 HP, 30 Foot Range
Loading...
+ 12 hidden pages