Cisco SG350X-24P, SG350X-24MP, SG350X-48P, SG350X-8PMD, SG350X-48MP Quick Start Manual

...
Quick Start Guide
Cisco 350X Series Managed Switches
2 Cisco 350X Series Managed Switches
Welcome
Thank you for choosing the Cisco 350X Series Managed Switches. The switches are designed to be operational right out-of-the-box as standard layer 2 and 3 switches. Using the default configuration, your switch forwards packets between the connecting devices after power up.
This guide familiarizes you with the switch layout and describes how to deploy the switch in your network. For additional information, see
www.cisco.com/go/350xswitches.
Package Contents
Your Cisco 350X Series Managed Switch
Power Cord
Rack-Mount Kit and Rubber Feet
DB-9 to RJ45 Serial Cable
Quick Start Guide
Pointer Card with China RoHS
Technical Support Contacts
EU Directives 1999/5/EC Compliance Information (for EU SKU only)
Before You Begin
Before you begin the installation, make sure that you have the following:
RJ-45 Ethernet cables for connecting network devices. A category 6a and higher cable is required for 10G ports; a category 5e and higher cable is required for all other ports.
Console cable for using the console port to manage your switch.
Tools for installing the hardware. The rack-mount kit packed with the
switch contains four rubber feet for desktop placement, and two brackets and twelve screws for rack-mounting. If the supplied screws are lost, use replacement screws in the following size:
Diameter of the screw head: 6.9 mm
Length of face of screw head to base of screw: 5.9 mm
Shaft diameter: 3.94 mm
1
Cisco 350X Series Managed Switches 3
Computer with Internet Explorer (version 9.0, 10.0, 11.0), or Firefox (version 36.0, 37.0 or higher), or Chrome (version 40,41,42 or higher) for using the web-based interface or the console port to manage your switch.
Mounting the Cisco 350X Series Switches
Your switch can be installed in the following ways:
Place the switch on a flat surface. To place the switch on a desktop, install the four rubber feet (included) on the bottom of the switch.
Mount the switch in a standard rack (1 rack unit high).
Placement Tips
Do not deploy the switch in a location where any of the following conditions exist:
•Ambient Temperature—To prevent the switch from overheating, do not operate it in an area that exceeds an ambient temperature of 122°F (50°C).
•Air Flow—Be sure that there is adequate air flow around the switch.
Mechanical Loading—Be sure that the switch is level and stable to
avoid any hazardous conditions.
Circuit Overloading—Adding the switch to the power outlet must not overload that circuit.
Rack Mounting
You can mount the switches in any standard size, 19-inch (about 48 cm) wide rack. The switch requires 1 rack unit (RU) of space, which is 1.75 inches (44.45 mm) high.
CAUTION For stability, load the rack from the bottom to the top, with the
heaviest devices on the bottom. A top-heavy rack is likely to be unstable and might tip over.
2
4 Cisco 350X Series Managed Switches
To install the switch into a 19-inch standard chassis:
STEP 1 Place one of the supplied brackets on the side of the switch so that
the four holes of the brackets align to the screw holes, and then use the four supplied screws to secure it.
STEP 2 Repeat the previous step to attach the other bracket to the opposite
side of the switch.
STEP 3 After the brackets are securely attached, the switch is now ready
to be installed into a standard 19-inch rack.
Connecting Network Devices
To connect the switch to the network:
STEP 1 Connect an Ethernet cable to the Ethernet port of a computer,
printer, network storage, or other network devices.
STEP 2 Connect the other end of the Ethernet cable to one of the
numbered Ethernet ports of the switch.
The Ethernet port light turns green when the connection is active. Refer to Cisco 350X Series Switch Features for details about the different ports and LEDs on each switch.
400925
3
Cisco 350X Series Managed Switches 5
S
TEP 3 Repeat Step 1 and Step 2 for each device that you want to
connect to the switch.
NOTE A category 6a and higher cable is required for 10G ports; a category
5e or higher cable is required for all other ports. When you connect your network devices, do not exceed the maximum cabling distance of 100 meters (328 feet). It can take up to one minute for the attached devices or the LAN to be operational after it is connected. This is normal behavior.
Power over Ethernet Considerations
WARNING The switch is to be connected only to PoE networks without
routing to the outside plant.
If your switch is one of the Power over Ethernet (PoE) models, consider the following power requirement:
*60-Watt PoE extends the IEEE Power of Ethernet Plus standard to double the power per port to 60 Watts.
350 Switches with Power Over Ethernet
Model Power
Dedicated to Poe
Number of Ports Supporting Poe
Poe Standard Supported
SG350X-24P 195 Watts 1–24
*60-Watt UPoE: ports 1, 2, 13, 14
802.3af/at
60 -Watt PoE
802.3af/at, 4 pair PoE, Rest af/at
SG350X-24MP 382 Watts
SG350X-48P 382 Watts 1–48
*60-Watt UPoE: ports 1, 2, 3, 4, 25, 26, 27, 28
SG350X-48MP 740 Watts
SG350X-8PMD 240 Watts 1–24
*60-Watt UPoE: ports 5, 6, 7, 8
SG350X-24PD
375 Watts 1–24
*60-Watt UPoE: ports 11, 12, 23, 24
6 Cisco 350X Series Managed Switches
CAUTION Consider the following when connecting switches capable of
supplying PoE: The PoE models of the switches are PSE (Power Sourcing Equipment) that are capable of supplying DC power to attaching PD (Powered Devices). These devices include VoIP phones, IP cameras, and wireless access points. The PoE switches can detect and supply power to pre-standard legacy PoE Powered Devices. Due to the support of legacy PoE, it is possible that a PoE switch acting as a PSE may mistakenly detect and supply power to an attaching PSE, including other PoE switches, as a legacy PD. Even though PoE switches are PSE, and as such should be powered by AC, they could be powered up as a legacy PD by another PSE due to false detection. When this happens, the PoE switch may not operate properly and may not be able to properly supply power to its attaching PDs. To prevent false detection, you should disable PoE on the ports on the PoE switches that are used to connect to PSEs. You should also first power up a PSE device before connecting it to a PoE switch. When a device is being falsely detected as a PD, you should disconnect the device from the PoE port and power recycle the device with AC power before reconnecting its PoE ports.
Configuring the 350X Series Switches
Before You Begin
The switch can be accessed and managed by two different methods; over your IP network using the web-based interface, or by using the switch’s command-line interface through the console port. Using the console port requires advanced user skills.
These are the default settings used when configuring your switch for the first time.
Parameter Default Value
Username cisco Password cisco LAN IP 192.168.1.254
454
Cisco 350X Series Managed Switches 7
Configuring Your Switch Using the Web-based Interface
To access the switch with a web-based interface, you must know the IP address that the switch is using. The switch uses the factory default IP address of 192.168.1.254, with a subnet of /24.
When the switch is using the factory default IP address, the System LED flashes continuously. When the switch is using a DHCP server-assigned IP address or an administrator has configured a static IP address, the System LED is a steady green (DHCP is enabled by default).
NOTE If you are managing the switch through a network connection and
the switch IP address is changed, either by a DHCP server or manually, your access to the switch will be lost. You must enter the new IP address that the switch is using into your browser to use the web-based interface. If you are managing the switch through a console port connection, the link is retained.
To configure the switch using the web-based interface:
STEP 1 Power on the computer and your switch.
STEP 2 For Cisco 350XG switches, connect the computer to the OOB port
found on the front panel. For Cisco 350X switches, connect the computer to any network port.
STEP 3 Set up the IP configuration on your computer.
a. If the switch is using the default static IP address of
192.168.1.254/24, you must choose an IP address for the computer in the range of 192.168.1.2 to 192.168.1.253 that is not already in use.
b. If the IP addresses will be assigned by DHCP, make sure that
your DHCP server is running and can be reached from the switch and the computer. You may need to disconnect and reconnect the devices for them to discover their new IP addresses from the DHCP server.
NOTE Details on how to change the IP address on your computer
depend upon the type of architecture and operating system that you are using. Use your computers local Help and Support functionality and search for “IP Addressing.”
STEP 4 Open a web browser window. If you are prompted to install an
ActiveX plug-in when connecting to the device, follow the prompts to accept the plug-in.
STEP 5 Enter the switch IP address in the address bar and press Enter. For
example, http://192.168.1.254.
8 Cisco 350X Series Managed Switches
S
TEP 6 When the login page appears, choose the language that you prefer
to use in the web-based interface and enter the username and password.
The default username is cisco. The default password is cisco. Usernames and passwords are both case sensitive.
STEP 7 Click Log In.
If this is the first time that you have logged on with the default username and password, the Change Password page opens. The rules for constructing a new password are displayed on the page.
STEP 8 Enter a new password and confirm the password.
NOTE Password complexity is enabled by default. The password
must comply with the default complexity rules or it can be disabled temporarily by checking Disable next to the Password Strength
Enforcement option.
STEP 9 Click Apply.
CAUTION Make sure that any configuration changes made are saved
before exiting from the web-based interface by clicking on the Save icon. Exiting before you save your configuration results in all changes being lost.
The Getting Started page opens. You are now ready to configure the switch. Refer to the Administration Guide or see the help pages for further information.
Cisco 350X Series Managed Switches 9
Configuring Your Switch Using the Console Port
To configure the switch using the console port:
STEP 1 Connect a computer to the switch console port using the supplied
console cable.
STEP 2 Start a console port utility such as HyperTerminal on the computer.
STEP 3 Configure the utility with the following parameters:
115200 bits per second
8 data bits
no parity
1 stop bit
no flow control
STEP 4 Enter a username and password. The default username is cisco,
and the default password is cisco. Usernames and passwords are both case sensitive.
If this is the first time that you have logged on with the default username and password, the following message appears:
Please change your password from the default settings. Please change the password for better protection of your network. Do you want to change the password (Y/N) [Y]?
STEP 5 Enter Y, and set a new administrator password.
NOTE Password complexity is enabled by default. The password
must comply with the default complexity rules.
CAUTION Make sure that any configuration changes made are saved
before exiting.
You are now ready to configure the switch. Refer to www.cisco.com/go/
350xswitches to locate the CLI Guide for your switch.
NOTE If you are not using DHCP on your network, set the IP address type
on the switch to Static and change the static IP address and subnet mask to match your network topology. Failure to do so may result in multiple switches using the same factory default IP address of
192.168.1.254.
10 Cisco 350X Series Managed Switches
Stacking the Cisco 350XG Series Switches
Before configuring the switches as a stack, refer to the Administration Guide for additional details. Refer to the front panel graphics in Cisco
350X Series Switch Features to help with the stack port descriptions and
supported modules.
By default, the ports on a switch function as regular Ethernet ports, except if you configure them to do stacking. You cannot mix the stack speeds between the switches or ports.
WARNING Stack ports must be either configured with the same port
speed or have the same speed capability on the module or cable plug in. If the port speed is configured as auto, then the module plugged into these two ports will need to have the same speed capability, otherwise the switch will not be able to form as a stack with multiple units.
A stack can have up to four Cisco 350XG series switches in it. Any 10G port of the switch can be used for stacking. The switch can only be stacked without Mesh topology.
The switches in the same stack are connected together through their stack ports. Depending on the type of stack ports and the desired speed, you may need Cat6a Ethernet cables and/or Cisco approved modules or cables for the Cisco 350XG switches.
Cisco 350X Series Managed Switches 11
Cisco 350X Series Switch Features
This section describes the exterior of the switch to help familiarize you with your switch.
Product Models
Front Panel
The ports, LEDs, and Reset button are located on the front panel of the switch as represented in the following illustrations.
SG350X-8PMD
SG350X-48
Model Description
SG350X-24 24-Port Gigabit Stackable Managed Switch SG350X-24P 24-Port Gigabit PoE Stackable Managed Switch SG350X-24MP 24-Port Gigabit PoE Stackable Managed Switch SG350X-48 48-Port Gigabit Stackable Managed Switch SG350X-48P 48-Port Gigabit PoE Stackable Managed Switch SG350X-48MP 48-Port Gigabit PoE Stackable Managed Switch SG350XG-24F 24-Port 10G SFP+ Stackable Managed Switch SG350XG-24T 24-Port 10GBase-T Stackable Managed Switch SG350XG-2F10 12-Port 10G Stackable Managed Switch SG350XG-48T 48-Port 10GBase-T Stackable Managed Switch SG350X-8PMD 8-Port 2.5G PoE Stackable Managed Switch SG350X-24PD 24-Port 2.5G PoE Stackable Managed Switch
5
SG350XG-48T
12 Cisco 350X Series Managed Switches
SG350X-24
SG350X-24PD
Front Panel Ports
USB Port—The USB port connects the switch to a USB device so that you can save and restore the configuration files, firmware images, and SYSLOG files through the connected USB device.
RJ-45 Ethernet Ports—The RJ-45 Ethernet ports connect network devices, such as computers, printers, and access points, to the switch.
Multigigabit Ethernet Ports—Highlighted in blue, these ports support speeds of 100 Mbps, 1 Gbps, and 2.5 Gbps, on Cat 5e cables. Much of the cabling deployed worldwide is limited to 1 Gbps at 100 meters. Cisco Multigigabit Ethernet enables speeds up to 2.5 Gbps on the same infrastructure without replacing a cable.
60-Watt PoE Ports—Highlighted in yellow, the 60-Watt PoE ports double the PoE power to 60W.
SFP+ Port (if present)—The small form-factor pluggable plus (SFP+) are connection points for modules so that the switch can link to other switches. These ports are also commonly referred to as mini 10GigaBit Interface Converter ports. The term SFP+ will be used in this guide.
The SFP+ ports are compatible with Cisco modules MGBSX1, MGBLH1, MGBT1, MGBLX1, MGBBX1, as well as other brands of modules.
The Cisco SFP+ 10G optical modules that are supported in the Cisco switches are: SFP-10G-SR, and SFP-10G-LR.
The Cisco SFP+ Copper Cable modules for stacking that are supported in the Cisco switches are: SFP-H10GB-CU1M, SFP-H10GB-CU3M, and SFP-H10GB-CU5M.
The SFP+ port is a combination port, shared with one other RJ-45 port. When the SFP+ is active, the adjacent RJ-45 port is disabled.
The LEDs of the corresponding RJ-45 port flash green to respond to the SFP interface traffic.
Cisco 350X Series Managed Switches 13
SFP Port (if present)—The small form-factor pluggable (SFP) ports are connection points for modules, so the switch can link to other switches. These ports are also commonly referred to as miniGigaBit Interface Converter (miniGBIC) ports. The term SFP is used in this guide.
SFP ports are compatible with Cisco modules MGBT1, MGBSX1, MGBLH1, MGBLX1, MGBBX1, MFELX1, MFEFX1, and MFEBX1, as well as other brands of modules.
Some SFP interfaces are shared with one other RJ-45 port, called a combo port. When the SFP is active, the adjacent RJ-45 port is disabled.
The LEDs of the corresponding RJ-45 port flash green to respond to the SFP interface traffic.
OOB Port (if present)—The Out of Band (OOB) port is a CPU’s Ethernet port that can be used only as a management interface. Bridging between the OOB port and the in-band Layer 2 interface is not supported.
Front Panel LEDs
PoE (if present)—(Amber) Located on the right of the port. The LED lights steady when power is being supplied to a device attached to the corresponding port.
Master—(Green) The LED lights steady when the switch is a stack master.
System—(Green) The LED lights steady when the switch is powered on, and flashes when booting, performing self-tests, or acquiring an IP address. If the LED flashes Amber, the switch has detected a hardware failure, a firmware failure, and/or a configuration file error.
Stack ID—(Green) The LED lights steady when the switch is stacked and the corresponding number indicates its Stack ID.
LINK/ACT—(Green) Located on the left of each port. The LED lights steady when a link between the corresponding port and another device is detected, and flashes when the port is passing traffic.
XG—(Green) Located on the right of a 10G port. The LED lights steady when another device is connected to the port, is powered on, and a 10 Gbps link is established between the devices. When the LED is off, the connection speed is under 10 Gbps or nothing is cabled to the port.
Gigabit—(Green) Located on the right of the OOB port. The LED lights steady when another device is connected to the port, is powered on, and a 1000 Mbps link is established between the devices. When the LED is off, the connection speed is under 1000 Mbps or nothing is cabled to the port.
14 Cisco 350X Series Managed Switches
SFP+ (if present)—(Green) Located on the right of a 10G port. The LED lights steady when a connection is made through the shared port, and flashes when the port is passing traffic.
Reset Button
The switch can be reset by inserting a pin or paper clip into the Reset button opening on the front panel of the switch. See Returning the
Switches to the Factory Default Settings for details.
Back Panel
The power port and console port are located on the back panel of the switch. The back panel of your particular switch may look different, and if your model has a fan, allow for adequate air circulation.
Power—Connects the switch to AC power.
Console—Connects a serial cable to a computer serial port so that it can be configured by using a terminal emulation program.
Returning the Switches to the Factory Default Settings
To use the Reset button to reboot or reset the switch, do the following:
To reboot the switch, press and hold the Reset button for less than ten
seconds.
To restore the switch to its factory default settings:
Disconnect the switch from the network or disable all DHCP
servers on your network.
With the power on, press and hold the Reset button for more than
ten seconds.
400924
6
Cisco 350X Series Managed Switches 15
Troubleshoot Your Connection
If you cannot access your switch from the web-based interface, the switch may not be reachable from your computer. You can test network connections by using ping on a computer running Windows:
STEP 1 Open a command window by selecting Start > Run and enter cmd.
STEP 2 At the Command window prompt, enter ping and the switch IP
address. For example, ping 192.168.1.254 (the default static IP address of the switch).
If you can reach the switch, you should get a reply similar to the following:
Pinging 192.168.1.254 with 32 bytes of data: Reply from 192.168.1.254:bytes=32 time<1ms TTL=128
If you cannot reach the switch, you should get a reply similar to the following:
Pinging 192.168.1.254 with 32 bytes of data: Request timed out.
Possible Causes and Resolutions
The Switch is not Powering on
Verify the power cord is plugged firmly into the switch and into the power outlet.
Verify that the power outlet is active.
Verify that the computer is on.
Replace the power adapter, before replacing the switch, if the situation
continues.
Bad Ethernet connection
Check the LEDs for proper indications. See Front Panel for details.
Check the connectors of the Ethernet cable to ensure that they are
firmly plugged into the switch and your computer.
Use a different Ethernet cable or port.
Bad Console port connection
Verify the console cable connectors are firmly plugged into the switch and your computer.
Verify the console port utility is configured with the correct parameters.
16 Cisco 350X Series Managed Switches
IP Addressing Issues
The Cisco switches can also be accessed by the Cisco FindIT Network Discovery Utility that automatically discovers all Cisco Small Business devices in the same local network segment as your computer. You can view device information including the current IP address, download the latest firmware for the device, or launch the product configuration utility to view and configure the settings. For more information, see www.cisco.com/go/findit.
Verify that you are using the correct IP address of the switch. Determine the current IP address of the switch from the CLI through the console port, Cisco FindIT, or from your network administrator. The System LED provides an indication of where the switch received the IP address (See
Front Panel for details.)
Make sure that no other device is using the same IP address as the
switch.
No IP route
If the switch and your computer are in different IP subnets, you need one or more routers to route the packets between the two subnets.
Unusually long access time
Due to the standard spanning tree loop detection logic, adding new connections may take 30 to 60 seconds for the affected interfaces and/or LAN to become operational.
Cisco 350X Series Managed Switches 17
Where to Go From Here
WARNING This is a class A product. In a domestic environment this
product may cause radio interference in which case the user may be required to take adequate measures.
Cisco Support Community www.cisco.com/go/smallbizsupport
Cisco Support and Resources
www.cisco.com/go/smallbizhelp
Phone Support Contacts www.cisco.com/en/US/support/
tsd_cisco_small_business _support_center_contacts.html
Cisco Firmware Downloads www.cisco.com/go/smallbizfirmware
Select a link to download firmware for Cisco Products. No login is required.
Cisco Open Source Requests
To receive a copy of the source code to which you are entitled under the applicable free/open source license(s) (such as the GNU Lesser/General Public License), please send your request to:
externalopensource-requests@cisco.com
In your requests please include the Cisco product name, version, and the 18 digit reference number (for example: 7XEEX17D99-3X49X081) found in the product open source documentation.
Cisco Partner Central (Partner Login Required)
www.cisco.com/web/partners/sell/smb
Product Documentation
350X Series www.cisco.com/go/350xswitches
Regulatory Compliance and Safety Information
ww w.cisco.com/en/US/docs/switches/lan/ csb_switching_general/rcsi/ Switch_RCSI.pdf
Warranty Information www.cisco-warrantyfinder.com
7
Americas Headquarters
Cisco Systems, Inc. www.cisco.com
Cisco has more than 200 offices worldwide. Addresses, phone numbers, and fax numbers are listed on the Cisco website at
www.cisco.com/go/offices.
Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Ciscotrademarks, go to this URL:
www.cisco.com/go/trademarks. Third-party trademarks mentioned are the property of their
respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (1110R)
© 2017 Cisco Systems, Inc. All rights reserved.
Loading...