Cisco Systems OL-11568-01 User Manual

Data Center Infrastructure Design Guide
2.1—Readme File
OL-11568-01
Corporate Headquarters
Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000
Fax: 408 526-4100
ALL DESIGNS, SPECIFICATIONS, STATEMENTS, INFORMATION, AND RECOMMENDATIONS (COLLECTIVELY, "DESIGNS") IN THIS MANUAL ARE PRESENTED "AS IS," WITH ALL FAULTS. CISCO AND ITS SUPPLIERS DISCLAIM ALL WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING, USAGE, OR TRADE PRACTICE. IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THE DESIGNS, EVEN IF CISCO OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
THE DESIGNS ARE SUBJECT TO CHANGE WITHOUT NOTICE. USERS ARE SOLELY RESPONSIBLE FOR THEIR APPLICATION OF THE DESIGNS. THE DESIGNS DO NOT CONSTITUTE THE TECHNICAL OR OTHER PROFESSIONAL ADVICE OF CISCO, ITS SUPPLIERS OR PARTNERS. USERS SHOULD CONSULT THEIR OWN TECHNICAL ADVISORS BEFORE IMPLEMENTING THE DESIGNS. RESULTS MAY VARY DEPENDING ON FACTORS NOT TESTED BY CISCO.
CCVP, the Cisco Logo, and the Cisco Square Bridge logo are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn is a service mark of Cisco Systems, Inc.; and Access Registrar, Aironet, BPX, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, CCSP, Cisco, the Cisco Certified Internetwork Expert logo, Cisco IOS, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Cisco Unity, Enterprise/Solver, EtherChannel, EtherFast, EtherSwitch, Fast Step, Follow Me Browsing, FormShare, GigaDrive, GigaStack, HomeLink, Internet Quotient, IOS, iPhone, IP/TV, iQ Expertise, the iQ logo, iQ Net Readiness Scorecard, iQuick Study, LightStream, Linksys, MeetingPlace, MGX, Networking Academy, Network Registrar, Packet, PIX, ProConnect, RateMUX, ScriptShare, SlideCast, SMARTnet, StackWise, The Fastest Way to Increase Your Internet Quotient, and TransPath are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the United States and certain other countries.
All other trademarks mentioned in this document or Website are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (0612R)
Data Center Infrastructure Design Guide 2.1—Readme File
© 2007 Cisco Systems, Inc. All rights reserved.
What is Included in this DG Release? 1
CONTENTS
OL-11568-01
Data Center Infrastructure Design Guide 2.1—Readme File
iii
Contents
iv
Data Center Infrastructure Design Guide 2.1—Readme File
OL-11568-01

Data Center Infrastructure Design Guide 2.1— Readme File

What is Included in this DG Release?

This design guide (DG) provides guidelines for designing and building the data center switching infrastructure.
Table 1 lists the technologies used in the data center infrastructure design documented in version 2 of
this design guide. This table provides a quick glance of the topics and lists the timeframe (current or future) of documentation availability for each technology.
Table 1 Cisco Data Center Technologies and DG Status
Technology/Product Description Other In this DG?
Cisco Catalyst 6500 WS-X6708-10G-3C
Cisco Catalyst 6500 next generation hardware—Sup720 and 6700 Series line cards.
8 port 10 GigE line card for the Catalyst 6500 Series switch
This DG is based on lab testing using the Sup720 and 6700 Series line cards in the Cisco Catalyst 6500 platform in core, aggregation, and access layer switches.
6708 notations have been added to reflect the increased port density. Testing is scheduled for a future DG release. The data sheet is available at:
http://www.cisco.com/en/US/pr oducts/hw/switches/ps708/prod ucts_data_sheet09186a00801dc e34.html
Native 12.2.18 SXD3 was used in the lab environment.
No
Yes
Corporate Headquarters: Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA
Copyright © 2006 Cisco Systems, Inc. All rights reserved.
What is Included in this DG Release?
Table 1 Cisco Data Center Technologies and DG Status (Continued)
Application Control Engine (ACE) The ACE module introduces a next
generation load balancer and security services module that permits higher performance and active-active designs. The ACE module is not an available product at the time of this writing.
Firewall Services Module (FWSM) Release 3.1
Release 3.1 of the FWSM software introduces several new capabilities including Private VLAN support and active-standby context groups, which permit load balancing of contexts across an FWSM redundant pair.
Release 3.1 is not available at the time of this writing.
Data center security See the data center security DG
at the following URL:
http://www.cisco.com/en/US/net sol/ns656/networking_solutions _design_guidances_list.html#an chor3
Cisco CatOS-IOS hybrid Hybrid CatOS-IOS software in the
Cisco Catalyst 6500 platform
This DG is based on the Cisco Native IOS solutions only in the Cisco Catalyst 6500 and 4948-10GE-based products.
Pervasive 10GE This design guide focuses on the use
of 10GE technology as a primary technology used in access layer uplinks, aggregation, and core connections.
Server fabric switching— Infiniband
Service module integration (for example, FWSM, IDS, CSM, NAM, and SSLSM)
Designing for HPC or database clusters using Infiniband technology
Integration of service modules and appliances into the data center infrastructure
No
Service modules are examined for interoperability and placement guidelines. Detailed design and configuration guides can be found at the following URL:
http://www.cisco.com/en/US/net sol/ns656/networking_solutions _design_guidances_list.html#an chor3
1RU access layer design Using 1RU switches in the access
layer design best practices
Testing is focused on the Cisco Catalyst 4948-10GE 1RU switch.
No
No
No
No
Yes
No
Yes
Data Center Infrastructure Design Guide 2.1— Readme File
2
OL-11568-01
Table 1 Cisco Data Center Technologies and DG Status (Continued)
What is Included in this DG Release?
Environmental Designing for proper cabling,
cooling/airflow, and power configurations
Network Management Using the NAM, CVDM,
CiscoWorks, Netflow, or other management/configuration tools
Geographically dispersed clustering (also known as stretch clusters)
Designing in support of extending Layer 2 domains to support HA clustering across metro or wide area networks
CPU protection from STP loop conditions
Design best practices in limiting the impact of failures related to spanning tree loop conditions
Spanning tree—Using 802.1w Rapid PVST+ and 802.1s MST
Designing scalable spanning tree domains using 802.1w and 802.1s and related features
Layer 2 access design Designs using L2 looped and
loop-free access layer topologies
Layer 3 access design Designs using L3 access layer
topologies
Service layer switch design How to move service modules out of
the aggregation layer and into a separate service switch chassis for CSM and SSL modules
Distributed Forwarding Card placement and benefits
Where to use DFC3 daughter cards to improve distributed switching performance in the data center
Enterprise campus segmentation The need to isolate/segment multiple
logical network environments on the same physical network for administration, security, or other purposes.
Use of NSF/SSO for high availability in the data center
Where to use redundant supervisors in the data center architecture, and designing to support required failover times
Covered in multi-tier and server cluster architecture chapters
This is covered outside of this DG document.
No
No
No
Yes
Yes
Yes
No
Yes
Yes
No
Yes
OL-11568-01
Table 2 lists the technologies used in the data center infrastructure design documented in the previous
v1.1. Note that version 2.1 builds on the v1.1 and v 2.0 design recommendations and it is not intended to be a replacement.
Data Center Infrastructure Design Guide 2.1— Readme File
3
What is Included in this DG Release?
Table 2 Technologies used in the Data Center Infrastructure Design Documented in DG v1.1
Technology/product Description
Layer 3 data center design Using OSPF and EIGRP in the data center design
Layer 3 security Using dynamic routing protocol authentication
Use of VTP in Layer 2 designs Why not to use VTP in the data center
Choosing a spanning tree protocol Explains the differences between 802.1w, Rapid PVST+ and
Using LoopGuard and UDLD
Using PortFast and TrunkFast
Layer 2 security Explains VLAN hopping, MAC flooding, ARP spoofing, and
Default gateway design Reviews configurations for HSRP in the data center
ARP table tuning Tuning the ARP table size to optimize traffic characteristics
NIC teaming design Covers the various NIC teaming methods and connectivity
Mainframe OSA and OSPF design Explains mainframe connectivity options when using the OSA
PortFast and BPDU Guard When to use PortFast and BPDU Guard on server ports
Port security Covers server port security options
Server port configurations Examples of server port switch configurations
Network management configuration Configuring user names and passwords, VTY access, SNMP,
VLAN configuration Configuring VTP, MAC address reduction, and other VLAN
Spanning tree configuration How to configure Rapid PVST+, MST, and protection from
Switch-to-switch trunk configuration EtherChannel and trunking configuration between the
MST and when to use each
spanning tree vulnerabilities
options
interface and covers IP addressing and OSPF configurations
and logging
features
loops with UDLD and LoopGuard
aggregation layer switches