Installing the Cisco ONS 15600 OC192/STM64
LR/LH 4 Port 1550 Card
NoteThe terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These
terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring
configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer
generally to Cisco's path protection feature, which may be used in any topological network
configuration. Cisco does not recommend using its path protection feature in any particular
topological network configuration.
Product Name: 15600-192L4-LR1550=
This document contains a description of OC192/STM64 LR/LH 4 Port 1550 card features, installation
procedures, removal instructions, and technical specifications. Use this document in conjunction with
the Cisco ONS 15600 Reference Manual, the Cisco ONS 15600 Procedure Guide, and the Cisco ONS15600 Troubleshooting Guide when working with OC192/STM64 LR/LH 4 Port 1550 cards.
This document contains the following sections:
• “OC192/STM64 LR/LH 4 Port 1550 Card” section on page 2
• “OC192/STM64 LR/LH 4 Port 1550 Card Features and Functions” section on page 2
• “Replace an OC-192 Card” section on page 8
• “Obtaining Documentation” section on page 12
• “Obtaining Technical Assistance” section on page 14
This document contains the following procedures:
“Replace an OC-192 Card” procedure on page 8
NoteFor information about circuits and card capacities, see the Cisco ONS 15600 Reference Manual.
Warning
Only trainedand qualified personnel should be allowed to install, replace, or service this equipment.
Corporate Headquarters:
Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA
Read the installation instructions before you connect the system to its power source.
This unit is intended for installation in restricted access areas. A restricted access area is where
access can only be gained by service personnel through the use of a special tool, lock and key, or
other means of security, and is controlled by the authority responsible for the location.
Voltageispresentonthebackplane when the system is operating. Toreduceriskof an electric shock,
keep hands and fingers out of the power supply bays and backplane areas.
Invisible laser radiationmay be emitted from the end ofthe unterminated fiber cable orconnector.Do
not stare into the beam or view directly with optical instruments. Viewing the laser output with
certain optical instruments (for example, eye loupes, magnifiers,and microscopes) withina distance
of100 mm may pose aneyehazard. Use of controls oradjustments or performance of proceduresother
than those specified may result in hazardous radiation exposure.
OC192/STM64 LR/LH 4 Port 1550 Card
OC192/STM64 LR/LH 4Port 1550 Card Features and Functions
The OC192/STM64 LR/LH 4 port 1550 card provides four long-range, Telcordia-compliant, GR-253
SONET OC-192 ports per card. The ports operate at 9953.28 Mbps over a single-mode fiber. The
OC192/STM64 LR/LH 4 port 1550 card has four physical connector adapters with two fibers per
connector adapter. The card supports STS-1 payloads and concatenated payloads at STS-3c, STS-12c,
STS-24c, STS-48c, or STS-192c signal levels.
OC192/STM64 LR/LH 4Port 1550 Slots and Connectors
You can install OC192/STM64 LR/LH 4 port 1550 cards in slots 1 through 4 and 11 through 14. The
card provides four bidirectional OGI type connector adapters on the faceplate (angled downward),
carrying two fiber strands (1 transmit and 1 receive). Only one transmit and receive pair is used per
connector adapter. On a breakout cable, use port three, fiber 4 (transmit) and fiber 3 (receive).
NoteSONET path PMs will not count unless IPPM is enabled. For additional information, see the Enabling
Intermediate-Path Performance Monitoring section in the Cisco ONS 15600 Procedures Guide. To
monitor SONET path PMs, log into the far-end node directly.
Installing the Cisco ONS 15600 OC192/STM64 LR/LH 4 Port 1550 Card
4
78-15181-01
OC192/STM64 LR/LH 4 Port 1550 Card
OC192/STM64 LR/LH 4Port 1550 Faceplate and Block Diagram
Figure 1 shows the OC192/STM64 LR/LH 4 port 1550 faceplate and a block diagram of the card.
Figure 1OC192/STM64 LR/LH 4 port 1550 faceplate and block diagram
OC192/STM64
LR/LH 4 PORT
1550
STAT
SRV
SD
SF
LASER ON
C
2
I
O&M A
SCLAN A
SCLAN B
O&M B
16
16
4 x OC-192
sync 0
sync 1
–48V A
–48V B
OC192
C-STS-48 copy A
C-STS-48 copy B
4 x OC-192
16
16
Note: Each C-STS-192 is split into four
C-STS-48s for cross-connect purposes.
C-STS-48 copy A
C-STS-48 copy B
76227
78-15181-01
Installing the Cisco ONS 15600 OC192/STM64 LR/LH 4 Port 1550 Card