Cisco 1000 2xGBE Quick Start Manual

Page 1
Americas Headquarters
Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000
Fax: 408 527-0883
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
Release 3.1 May 2007
Customer Order Num b er : Text Part Number: OL-7822-06
Page 2
THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS M ANUAL ARE SUBJECT TO CHA NGE WITHOUT NO TICE. ALL STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSI BILITY FOR THEIR APPLICA TION OF ANY PRODUCT S.
THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORT H IN THE INFORMATION PACKET T HAT SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE OR LIMITED WARRANTY, CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY.
The Cisco implementation of TCP head er compressi on is an adap tation of a program developed by the Universi ty of Ca lifornia, Berk eley (UCB) as part of UCB ’s public domain version of the UNIX operatin g system. All rights reserved . Copyri ght © 1981 , Rege nts of the Uni versity of Calif ornia.
NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE OF THE SE SUPPLIERS ARE PROVIDED “AS IS” WITH ALL FAULTS. CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAI M ALL WARRANTIE S, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NO NINFRINGEM ENT OR ARISING FROM A COURS E OF DEALING, USAGE, OR TRADE PRACTICE.
IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING , WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL, EVEN IF CISCO OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE S.
Any Internet Protocol (IP) addresses used in this document are not intended to be actual addresses. Any examples, command display output, and figures included in the document are shown for illustrative pur poses onl y. Any use of act ual IP addr ess es in ill ustr ativ e conten t is uninten tio nal and coincident al.
Cisco Service Control Engine 1000 2xGBE Quick Start Guid e
© 2007 Cisco Systems, Inc. All rights res erved.
CCSP, the Cisco Square Bridge logo, Follow Me Browsing, and StackWise are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn, and iQuick Study are service marks of Cisco Systems, Inc.; and Access Registrar, Aironet, ASIST, BPX, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, Cisco, the Cisco Certified Internetwork Expert logo, Cisco IOS, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Cisco Unity, Empowering the Internet Generation, Enterprise/Solver, EtherChannel, EtherFast, EtherSwitch, Fast Step, FormShare, GigaDrive, GigaStack, HomeLink, Internet Quotient, IOS, IP/TV, iQ Expertise, the iQ logo, iQ Net Readiness Scorecard, LightStream, Linksys, MeetingPlace, MGX, the Networkers logo, Networking Academy, Network Registrar, Packet, PIX, Post-Routing, Pre-Routing, ProConnect, RateMUX, ScriptShare, SlideCast, SMARTnet, StrataView Plus, SwitchProbe, TeleRouter, The Fastest Way to Increase Your Internet Quotient, TransPath, and VCO are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the United States and certain other countries.
All other trademarks mentioned in this document or Website are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (0501R)
Page 3
iii
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
CONTENTS
CHAPTER
1 Prepare for Install ation 1-1
Information About Preparing for Installation 1-1
Site Preparation and Unpacking 1-1 Tools and Parts 1-2 Prepare for Rack-Mount Installation 1-2
Workbench or Tabletop Installation 1-2
CHAPTER
2 Rack-Mount the SCE 1000 2-1
The SCE 1000 Mounting Brackets 2-1 Attach the Bracket s to the SCE 1000 2-2 Installing the Crossrail Supports (Four-post rack only) 2-3
Assemble the Crossrail Supports 2-3 Attach the Crossra il Supports to the Rack 2-4
Mount the System to the Rack 2-4
CHAPTER
3 Connect the Power Supply Units 3-1
Connect the Chassis Ground 3-1 Connecting the Power 3-2
Connect the DC-Input Power Supply Unit 3-3 Connect the AC-Input Power Supply Unit 3-4
CHAPTER
4 Connect the Management Interfaces and Perform Initial System Configuration 4-1
Connect the Lo c al Con sole 4-1 Perform the Initial System Configuration 4-2
Initial System Configuration 4-2
The Setup Command 4-3 Setup Command Parameters 4-4 Example 4-6
Step 1: Configur in g In itial Settings 4-6
Example 4-7 Step 2: Configuring the Hostname 4-7 Step 3: Setting th e Passwords 4-7
Page 4
Contents
iv
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
EXAMPLE: 4-8
Step 4: Configuring Time Settings 4-8
EXAMPLE: 4-10
Step 5: Configuring the DNS Settings 4-10
EXAMPLE: 4-11
Step 6: Configuring the RDR Form a tt er De st in ation 4-12
EXAMPLE: 4-12
Step 7: Configuring Access Control Lists (ACLs) 4-12
Information Abou t Access Control Lists 4-12 Examples 4-15
Step 8: Configuring SNMP 4-16
EXAMPLE: 4-19
Step 9: Configuring the Topology-Dependent Parameters 4-20
About the Topology-Dependent Parameters 4-20 Examples 4-21
Step 10: Completing and Saving the Configur ation 4-22
Examples 4-24
Connect the Management Interface 4-25
EXAMPLE: 4-25
CHAPTER
5 Cable the Line Ports 5-1
Information About Cabling 5-1
Single Link: Inline Topology 5-1 Single Link: Receive-only Topology 5-2
Cabling the Line Interfaces 5-3
Configure Gigabi tEthernet Auto-Negotiation 5-3 Connect the GBE Line Interface Ports 5-4
CHAPTER
6 Completing the Installation 6-1
Examining the LE D s 6-1 Final Tests 6-1
Verifying Operational Status 6-1
Example: 6-2
Viewing the User Log Counters 6-2
EXAMPLE: 6-2 Viewing Configuration 6-2 Saving the Configuration Settings 6-3
Examples 6-4
EXAMPLE 1: 6-4
Page 5
Contents
v
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
EXAMPLE 2: 6-4
CHAPTER
7 Installing a Service Control Application 7-1
Advanced Configuration of the SCE Platform 7-1 Loading and Activating a Service Control Application 7-1
CHAPTER
8 Troubleshoot Startup Problems 9-1
SCE 1000 Operationa l Status 9-1 Identifying Startup Problems 9-3 CLI Commands for Troubleshooting 9-3
Page 6
Contents
vi
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Page 7
CHAPTER
1-1
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
1
Prepare for Installation
This section cont ai ns war nings, in for mat ion abo ut t ool s and pa rts, sit e pr ep ar ation i nform a tion , an d information fo r work ben ch or t abl eto p instal la tio n and ra ck-m ou nt i nsta llat ion.
This warning symbol means dange r. You are in a situation tha t could cause bodily injur y. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accide nts. To see translations of the warnings that ap pear in t his publication, refer to the translated safety warnings that accompanied this device.
Only trained and qualified person nel should in stall, re place, or service this eq uipm ent. Read the installation instructions before you connect the system to its power source. This unit is intended for installation in restricted access areas. A restricted access area is where access
can only be gained by serv ice pe rso nnel thro ugh the use of a specia l t ool, loc k and key, or other means of security, and is controlled by the authority responsible for the location.
Voltage is present on the backplane when the system is operating. To reduce risk of an electric shock, keep hands and fingers ou t of th e p ower suppl y bays an d backp l ane ar ea s.
Do not work on the sy stem or c on nect o r di sconne c t cab les dur ing pe riods of l ight nin g ac tivity. Before beginning the in stal la tion o f t he SCE 10 00, r ea d t he R egulatory Complia nce and Saf ety
Information for the Cisco Serv ice C ontrol Engine document.
Information About Preparing for Installation
Site Preparation an d Un pack in g, pa ge 1-1
Tools and Parts, page 1-2
Prepare for R ack -Mo unt Inst al lati on, p ag e 1-2
Site Preparation and Unpacking
Lift the SCE 1000 pla tfor m safe ly ou t of t he pa ck ing c on taine r.
Ensure the power service at the si te is suita ble for the SCE 1000 plat form.
Check the packing slip to ensure that all the proper components are present.
Locate and have accessible the Site Log for recording information about this installation.
Page 8
1-2
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 1 Prepare for Installation
Workbench or Tabletop Ins tallation
Tools and Parts
Use the following list of to ols and parts as a c hecklist for prepari ng for installing the SCE 1000 platform:
Appropriate cables t o connect th e SCE 1000 to th e network and co nsole term inal
Tape measure (optional)
Level (optional)
Number 1 Phillips screwdriver
Number 2 Phillips screwdriver
1/4-inch flat-b lade screwdriver
1/4-inch hex wren ch
Grounding kit (shipped with the SCE 10 00)
12 AWG or 2.5 mm c opp er inst al lati on w ire wi th h ex or loop conn ec tor s f or D C p ower lead s ( DC
power only) Ring term ina ls mu st be UL a pproved an d su itabl e f or 12 AWG wire.
AC power cords (AC power only, shipped with SCE 1000)
Rack-mounting kit (ship ped wit h SCE 1000)
Spare screws for changing bracket position
Prepare for Rack-Mount Installation
Before you begin the rack-mounting tasks, determine the type of rack—four-post or two-post—that you will be using.
Workbench or Tabletop Inst allation
Figure 1-1 Tabletop Installation of the SCE 1000 Platform
For a workbench or tabletop installa tion, verify the following before installin g the SCE 1000 pl atform :
The SCE 1000 platform is off the floor and has adequate ventilation.
C
is
c
o
S
C
E
1
0
0
0
S
eries
2
x
G
B
E
L
IN
K
R
X
T
X
R
X
M
M
T
X
L
IN
K
R
X
T
X
R
X
M
M
T
X
G
B
E
-1
S
U
B
L
IN
E
N
E
T
P
W
R
B
S
T
A
T
U
S
P
W
R
A
B
Y
P
A
S
S
1
0
/
1
0
0
/
1
0
0
0
L
I
N
K
/
A
C
T
I
V
E
1
0
/
1
0
0
/
1
0
0
0
L
I
N
K
/
A
C
T
I
V
E
AUX
C
O
N
S
O
L
E
MNG 2
MNG 1
1
2
92967
Page 9
1-3
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 1 Prepare for Instal lation
Workbench or Tabletop Installation
An adequate chassi s grou nd (e art h) c onne ctio n exists for t he SC E 100 0 p latfo rm .
The SCE 1000 platform has at least 2 inches (5 cm) of clearance at each side and at least 5 inches
(12.7 cm) of clearance at the rear to allow proper air flow.
Step 1 Remove the adhesive strips from the four rubber fe et and affix the feet onto the four ma rked locati ons
on the bottom panel of the unit.
Step 2 Place the SCE 1000 pla tfo rm on t he t abl etop o r workbe nc h.
Page 10
1-4
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 1 Prepare for Installation
Workbench or Tabletop Ins tallation
Page 11
CHAPTER
2-1
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
2
Rack-Mount the SCE 1000
This section provides in forma ti on for r ack- mou nting the SCE 1000 pl at form.
The SCE 1000 Mou nting Bra ckets
Attach the Brackets to the SCE 1000
Installing the C rossrai l Supp orts (Four-post ra ck on ly)
Mount the System to the Rack
The SCE 1000 Mounting Brackets
There are two standard types of equipment racks, and the appropriate brackets for each are provided in the enclosed kit.
19” rack with front rack posts — the mounting kit includes two mounting brackets as illustrated
below:
Figure 2-1 Mounting Bracke t for 2-post Racks
19” rack with front and back rack posts — in addition to the mounting brackets illustrated below, the mounting kit includes two crossrail supports that the unit slides onto.
210429
Page 12
2-2
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter2 Rack-Mount the SCE 1000
Attach the Brackets to the SCE 1000
Figure 2-2 Mounting Bracke t for 4-post Racks
The SCE 1000 mounts to the two front rack posts with brackets that attach to the front of the SCE 1000 The inside width between th e two posts or mount ing strips (le ft and right ) must be at least 17.3 inch es (44 cm).
Note Remember to leave a two-inch (5 cm) clearance on both sides of the SCE 1000 and at the rear for
adequate airflow for the inlet and exhaust vents.
Attach the Brackets to the SCE 1000
Before installing the SCE 1000 in the rack, you must first install an appropriate rack-mount bracket on each side of the front of the SCE 1000, as illustrated in the following figures.
Figure 2-3 Attaching the Mounting Brackets (4-post)
210430
L
IN
K
R
X
T
X
R
X
M
M
T
X
L IN
K
R
X
T
X
R
X
M
M
T
X
P
W
R
B
S
T A
T U
S
P
W
R
A
B
Y P A
S S
10/100/ 1000
LINK
/
AC
T
IV
E
10/100/ 10
00
LIN
K/
AC
T
IVE
A
U
X
C
O
N
S
O
L
E
M
N G
2
M
N
G
1
Cisco SCE 1000
S
e
r
i
e
s
2xG
BE
GBE-1
SUB LINE
NET
1 2
210418
Page 13
2-3
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 2 Rack-Mount the SCE 10 00
Installing the Crossrail Supports (Four-post rack only)
Figure 2-4 Attaching the Mounting Brackets (2-post)
To install the rack-mount brackets on the SCE 1000 chassis, complete the following steps: Before installing the SCE 1000 in the rack, you must first install a rack-mount bracket on each side of
the front of the SCE 1000.
Step 1 Align the rack-mount bracket to the side of the SCE 1000. Choose the proper bracket for your installation
(2-post rack or 4-post rack) as illustrated in Rack-Mount the SCE 1000
Step 2 Insert and tighten three screws. Step 3 Repeat steps 1 and 2 on the other side of the SCE 100 0.
If mounting the SCE 100 0 in a r ack with on ly t wo pos ts, ski p to Mount the System to the Rack. If mounting the SCE 100 0 in a rac k with fo ur po sts, p roc eed to th e next st ep, Installing the Crossrail
Supports (Four-post rack only).
Installing the Crossrail Supports (Four-post rack only)
This section provides in for mati on for a ssembl ing the crossra il suppor t s and a ttac hing the m to the r ack. When mounting in a rack with four posts (front and back) the two crossrail supports are mounted one on
each side of the r ack. The SC E 1000 t he n sl ide s int o the se crossr ai ls, whi ch s uppo rt th e weigh t of t he unit.
Assemble the Crossrail Supports
Attach the Crossrail Supports to the Rack
Assemble the Crossrail Supports
Step 1 Assemble the two crossrail supports. Use three screws for each crossrail assembly.
L
I
N
K
R
X
T
X
R
X
M
M
T
X
L
I
N
K
R
X
T
X
R
X
M
M
T
X
P
W
R
B
S
T
A
T
U
S
P
W
R
A
B
Y
P
A
S
S
1
0
/ 1
0 0
/
1
0
0 0
L
IN
K
/
A
C
T
IV
E
1
0
/ 1
0 0
/
1
0
0 0
L
IN
K
/
A
C
T
I V
E
A
U
X
C
O
N
S
O
L
E
M
N
G
2
M
N
G
1
Cisco SC
E
1000
Series
2xGBE
GBE-1
SUB
LINE
NET
210603
1 2
Page 14
2-4
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter2 Rack-Mount the SCE 1000
Mount the System to the Rack
Figure 2-5 Assembl ing the Slider Brackets
Step 2
Make sure that they are oriented so that both crossrails will support the SCE 1000 when they are attached to the rack.
Attach the Crossrail Supports to the Rack
Step 1 Align the crossrail supports with the side of the rack, parallel to the floor.
Figure 2-6 Attaching the Crossrails to the Rack
Step 2
Insert and tighten two screws to the front posts or mo unting stri ps of the rack
Step 3 Insert and tighten two screws to the Back posts of the rack. Step 4 Repeat steps 2 and 3 on the other si de of the rack , keeping th e brackets flu sh against the posts and
parallel to the su ppo rti ng bra cket on first si de of the r ack.
Mount the System to the Rack
When the appropriate mounting brackets are securely installed, the SCE 1000 can be installed into the rack.
321
92777
321
92778
Page 15
2-5
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 2 Rack-Mount the SCE 10 00
Mount the System to the Rack
SUMMARY STEPS
1. Make sure that the rack brakes are locked or that the rack is otherwise stabilized.
2. Position the SCE 1000 so that the front end is closest to you, and lift it carefully to place it into the
rack. To prevent injury, avoid sudden twists or moves.
3. Slide the SCE 1000 into the rack, pushing it ba ck until the bracke ts (installed at the front of the SCE
1000) meet the m ountin g st ri ps or posts on both si des o f the rac k.
4. While keeping the br ackets f lush ag ainst the pos ts or mountin g strips , align th e holes in the b rackets
with the holes on the rack or mounting strip.
5. For each bracket, insert and tig hten two appr opriat e screws to the rack .
DETAILED STEPS
Step 1 Make sure that the rack brakes are locked or that the rack is otherwise stabilized.
Figure 2-7 Sliding the SCE Platform into the Rack
Step 2
Position the SCE 1000 so that the front end is clo sest to you, and lift it car efully to place it into the rack. To prevent injury, avoid sudden twists or moves.
Step 3 Slide the SCE 1000 into the rack, pushing it back until the brackets (installed at the front of the SCE
1000) meet the m ountin g st ri ps or posts on both si des o f the rac k.
L I N K R
X
C i s c
o S
C E
2 0
0 0
S e r i
e s
4 x G
B E
T X
R X M
M T
X
L I N K
R X T X
R X
M M T X
L I N K
R X T X
R X
M M T X
L
I N K R X T X
R X
M M
T X
G B E
-
1 S U B
L
I
N
E
N E T
P W R
B S T A
T U S
P W R A
B Y P A
S S
1 0 / 1 0 0 / 1 0 0 0
L I N
K
/ A C T I
V
E
1 0 / 1 0 0 / 1 0 0 0
L I N K
/ A C T I V E
G B E
-
2 S U
B L I N E / C A S
C
A
D
E
N E T
A U X
C O N S
O L E
M N
G 2
M
N G 1
L
IN
K
R
X
T X
R X
M
MT
X
L IN
K
R X
T X
R
X
M M
T
X
P
W R
B
S
T A
T
U S
P
W
R
A
B
Y
P A
S
S
10/100/ 1000
LIN
K /
A
C T
IV E
10/1
00/
1000
LIN
K /
A
C
T
IVE
A U
X
C
O N
S
O
L
E
M
N
G
2
M
N G
1
Cisco SC
E 1000
S
e
r
i
e
s
2xG
BE
GBE-1
SUB
LINE
NET
1 2 3
210419
Page 16
2-6
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter2 Rack-Mount the SCE 1000
Mount the System to the Rack
A rack with both front and back posts will have the crossrail supports installed. Slide the SCE 1000 onto these crossrails and push it all the way back.
Step 4 While keeping the brack ets flush against t he posts or mounting strips, al ign the holes in the brac kets with
the holes on the rack or mounting strip.
Figure 2-8 Securing the SCE Platform to the Rack
Step 5
For each bracket, insert and tighten two appropriate screws to the rack.
Note Since the brackets support t h e w eigh t of the e ntire SCE 100 0 cha ssis, be sure to use al l f our sc rews to
fasten the two rack-mount brackets to the rack posts.
L
IN
K
R X
T X
R X
M
M
T X
L
IN K
R
X
T X
R X
M
M
T X
P
W
R
B
S
T A
T U
S
P
W
R
A
B Y
P A
S S
1
0/100/ 1
000
L IN
K/
ACTIV
E
10/10
0/ 1 000
LINK
/
A
CTIV
E
A
U X
C
O
N
S
O L
E
M
N
G
2
M
N
G
1
Cisco SCE 1000
S
e
r
i
e
s
2xGBE
GBE-1
SUB LINE
NET
321
210420
Page 17
CHAPTER
3-1
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
3
Connect the Power Supply Units
This section pr ovides infor ma ti on for g rou nding the SC E 100 0 pl atfo rm and co nne ct ing t he AC or DC power supply units.
Connect the C has sis G ro und, p ag e 3-1
Connecting the Power, page 3-2
Connect the Chassis Ground
Figure 3-1 Grounding the Unit (AC)
IN PO
W
ER B O
K
IN
POW
ER A O
K
BYP
ASS 1
210421
21
Page 18
3-2
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 3 Connect the Power Supply Units
Connecting the Power
Figure 3-2 Grounding the Unit (DC)
A Grounding kit is p rovided wi th e ach SCE 10 00. Use th is Grou nding k it to p rop erl y g round th e SCE 1000 chassis.
When installing the unit, the chassis ground connection must always be made first and disconnected last.
Step 1 On the rear panel of the SCE 1000, locate the chassis grounding connector (refer to the appropriate figure
for an AC- or DC-powered SCE 1000 above).
Step 2 Attach the gro und ing c ab le (gre en a nd yel low color ed cab le) , firmly fasten in g th e (enc lo sed) hex n uts
and spring was he rs with a # ¼” hex w r ench (r ef er to t he a ppr op riat e figure fo r an AC- or DC -p owered SCE 1000 above).
The other side of the ground ing cable must be conne cted to the site equ ivalent of the AC earth.
Connecting the Power
The following sections describe how to reconnect the AC or DC power:
Connect the DC- Input Power Sup ply Un it, p age 3-3
Connect the AC-Input Power Supply Unit , pa ge 3-4
IN
PO
W
ER
B
O
K
IN
PO
W
ER
A
O
K
BYP
ASS 1
210422
21
Page 19
3-3
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 3 Connect the Power Supply Units
Connecting the Power
Connect the DC-Input Power Supply Unit
Figure 3-3 Connecting the DC Power
Before completing any of the following steps, and to prevent short-circuit or shock hazards, ensure that power is removed from the DC circuit. To ensure that all power to the power supply unit is OFF, locate the circuit breaker on the panel board that services the DC circuit, switch the circuit breaker to the OFF position, and tape the switch handle of the circuit breaker in the OFF position.
Wiring should be done by a professional in acco rdance w ith state an d loca l elect rical co des.
Step 1 Ensure that the DC power line input leads are disconnected from the power source. Step 2 Using the number 2 Phillips screwdriver, remove the protective plate from the termina l block . Step 3 Insert one receptacle screw into the hex or loop connector on one power line input, insert the screw with
the connector into the corresponding lead receptacle and tighten the receptacle screw using the number 2 Phillips. Repeat for the remaining power line input lead.
Note The color coding of the DC-input power supply leads depen ds on the col or coding of the DC power
source at your site. Make ce rtain th e lead co lor codi ng you cho ose for the D C-input power supply matches lead color co ding used at t he DC power source .
Note Use 12 AWG (2.5 mm ) coppe r wire on ly with hex or loop con nector s. Ring termi nals must be UL
approved and suitabl e for 1 2 AWG wire.
Step 4 Using the number 2 Phillips screwdriver, securely fasten the protective plate to the termin al block. Step 5 Connect the DC power line input leads to the DC power source through a fast 10A circuit breaker. Step 6 Turn the on/off switch to the on position.
IN POW
ER
BOK
IN
PO
W
ER
A
O
K
BYP
ASS 1
210424
Page 20
3-4
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 3 Connect the Power Supply Units
Connecting the Power
Step 7 Look at the IN an d O K LE Ds on the p ower suppl y un it an d th e co rre spo ndin g Power LE D o n th e fro nt
panel. If the D C-in put power s upply un it is op era ting p rop erly, these LEDs will be gl owing gr een.
Step 8 Ensure that the power supply is properly aligned and the installation screw is tightened.
Connect the AC-Input Power Supply Unit
Step 1 Plug the AC-input power cable into the AC-input power receptacle on the AC-input power supply
For AC-input power, we recommend powering the SCE 2000 platform from a 120 VAC, 15A receptacle U.S. (240 VAC, 10A internationa l) at the power source .
Figure 3-4 Connecting the AC Power
Step 2
Plug the AC power supply cable into the AC power source.
Step 3 Turn the on/off switch to the on position. Step 4 Look at the IN an d O K LE Ds on the p ower suppl y un it an d th e co rre spo ndin g Power LE D o n th e fro nt
panel. If the AC-input power supply unit is operating properly, these LEDs will be glowing green.
Step 5 Ensure that the power supply is properly aligned and the installation screw is tightened.
IN PO
W
ER B O
K
IN
PO
W
ER A OK
BYPASS 1
210423
Page 21
CHAPTER
4-1
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
4
Connect the Management Interfaces and Perform Initial System Configuration
This section explains how to connect the SCE 1000 platform to a local console and perform the initial system configuration via the setup wizard that runs automatically. Additionally, this section contains instructions for cabling the Fast Ethernet Management interface.
Connect the Local Console, page 4-1
Perform the Initial System Configuration, page 4-2
Connect the Ma nage ment I nterfac e, p ag e 4-25
Connect the Local Console
Figure 4-1 Connecting to the Local Console
You must first connect the unit to a local console and configure the initial settings for the SCE 1000 to support remote management. When the initial connection is established, the setup utility will run automatically, prompting you to perform the initial system configuration.
Make sure that the terminal configuration is as follows:
9600 baud
8 data bits
No Parity
1 stop bits
No flow control
C
is
c
o
S
C
E
1
0
0
0
S
e
rie
s
2
x
G
B
E
L
I
N
K
R
X
T
X
R
X
M
M
T
X
L
I
N
K
R
X
T
X
R
X
M
M
T
X
G
B
E
-
1
S
U
B
L
I
N
E
N
E
T
P
W
R
B
S
T
A
T
U
S
P
W
R
A
B
Y
P
A
S
S
1
0
/1
0
0
/
1
0
0
0
L
IN
K
/ A
C
T
IV
E
1
0
/1
0
0
/ 1
0
0
0
L
IN
K
/ A
C
T
IV
E
A
U
X
C
O
N
S
O
L
E
M
N
G
2
M
N
G
1
92965
3
21
Page 22
4-2
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 4 Connect the Management Interfaces and Perform Initial System Co nfiguration
Perform the Initial System Configuration
The above SCE 1000 po rt p ar amet ers a re fixed and a re no t c onfigurab l e.
Step 1 Plug the <SKIP>serial cable provided with the SCE 1000 into the CON port on the front panel of the
SCE 1000.
Step 1 Connect the other end of the serial cable (with an attached DB-9 connector) to the VT100 compatible
local (serial) terminal.
Step 2 At the console. p re ss Step 3 Enter Step 4 several times until the Cisco logo appears on the local terminal and the setup configuration dialog is
entered.
--- System Configuration Dialog --­At any point you may enter a question mark ‘?’ followed by ‘Enter’ for help. Use ctrl-C to abort configuration dialog at any prompt. Use ctrl-Z to jump to the end of the configuration dialog at any prompt. Default settings are in square brackets ‘[]’. Would you like to continue with the System Configuration Dialog? [yes/no]: y
Step 5 Type y and press pr ess Enter.
Enters the system c onfigura tio n d ialog .
Perform the Initial System Configuration
Initial System Co nfigurati on , pag e 4-2
Step 1: Configuring Initial Settings, page 4-6
Step 2: Configuring the Hostname, page 4-7
Step 3: Setting the Passwords, page 4-7
Step 4: Configuring Time Settings, page 4-8
Step 5: Configuring the DNS Settings, page 4-10
Step 6: Configuring the RDR Formatter Destination , page 4-12
Step 7: Configuring Access Control Lists (ACLs), page 4-12
Step 8: Configuring SNMP, page 4-16
Step 9: Configuring the Topology-Dependent Parameters, page 4-20
Step 10: Completing a nd Saving the Co nfigurat ion , pag e 4-22
Initial System Configuration
The Setup Command , pa ge 4-3
Setup Command Parame ters , pag e 4-4
Example, page 4-6
Page 23
4-3
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 4 Connect the Management Interfaces and Perform Ini tial System Configuration
Perform the Initial System Configuration
The Setup Command
Upon initial connection to the local terminal, as described above, the system configuration wizard automatically runs to guide the user throu gh the enti re setup process. The wizar d prompts for all necessary parameters, displaying def ault v al ues, w here ap plica ble. You may accept the defa ult values or define other values.
When the dialog is c om plete , you m ay r eview the new configurati on befor e a pplyi n g it. T he syste m displays the configuration, in cludi ng paramet ers that we re not chang ed. The system also displ ays any errors that are detected i n the configuration. When the co nfiguration is satis factory, you may apply and save the new configuration.
The following table lists all the parameters included in the initial configuration. It is recommended that you obtain values for any parameters that you will configure at this time before beginning the setup.
Note For further information regarding any configuration step or spe cific paramete r, refer to the relevant
section in the Cisco Service Control Engine (SCE) Software Configuration Guide .
Page 24
4-4
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 4 Connect the Management Interfaces and Perform Initial System Co nfiguration
Perform the Initial System Configuration
Setup Command Parameters
Table 4-1 Setup Command Parameters
Parameter Definition
IP address IP address of the SCE 1000. subnet mask Subnet mask of the SCE 10 00. default gateway Default gateway. hostname Character string used to iden tify the SCE 1000.
Maximum 20 characte rs.
admin password Admin level password.
Character string from 4- 100 char ac ter s beginni ng with an alpha character.
root password Root level password.
Character string from 4- 100 char ac ter s beginni ng
with an alpha character. password encryption status Enable or disable password encryption? Time Settings time zone name and o ffset Standard time zone abbreviation and minu tes
offset from UTC. local time and date Current local time and date. Use the format:
00:00:00 1 January 2002 SNTP Configuration broadcast client st atus Set the status of the SNT P b roadc as t c lie nt.
If enabled, the SCE wil l synchronize its local ti me
with updates received from SNTP broadcas t
servers. unicast query interval Interval in seconds between unicast requests for
update (64 – 1024 ) unicast server IP address IP address of the SNTP unicast server. DNS Configuration DNS lookup status Enable or disable IP DNS-bas ed hostn ame
translati on. default domain n am e Default domain na me to be use d for c omp leti ng
unqualified host names IP address IP address of domain name server. ( maximum of
3 servers) TCP port number TCP port number of the RDR-f orm atte r
destination Access Control Lists
Page 25
4-5
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 4 Connect the Management Interfaces and Perform Ini tial System Configuration
Perform the Initial System Configuration
Following are some general inst ruct ion s regar ding the se tup dia log:
All default values appear in square brackets [defaul t] .
If no value appears in the brackets [], or more than one option appears [ yes/no ], then this parame ter does not have a default value.
Access Control List number How many ACLs will be necessary? What IP
addresses will be permitted/denied access for each management interface ? You may want ACLs for the following :
Any IP access
Telnet access
SNMP GET access
SNMP SET access
list entries (m ax imum 20 per l ist ) IP address, and wh ethe r perm itte d or deni ed
access. IP access ACL ID number of the ACL controlling IP access. telnet ACL ID number of the ACL controlling telnet access. SNMP agent status Enable or disable SNM P manage ment. GET community names Community strings to allow GET access and
associated ACLs (max im um 2 0 ). SET community name s Community strings to allow SET ac cess and
associated ACLs (max im um 2 0 ). trap manager s ( maxi mu m 20) Trap manager IP address, com mun ity stri ng , a nd
SNMP version. Authentication Failure trap status Sets the status of the Authentication Failure traps. enterprise traps status Sets the status of the enterprise traps. system administrator Name of the system administrator. Topology Configuration connection mode Is the SCE 1000 installed using inline topology or
receive-only topology using an optical splitter? link bypass mode on ope ratio nal sta tus When the SCE 1000 is o per ation al, sh ould it
bypass traffic or not? link bypass mode on non- oper ationa l st atus When the SCE 1000 is n ot op er ati onal , sh ould it
bypass traffic or cut it off? priority (cascade topology only)
If this is a cascaded topology, is this SCE 1000 the
primary or secondary SCE 10 00? operational sta tus o f t he SCE a fter a bn orm al boo t After a reboot due t o a fail ur e, sh ould the SCE
1000 remain in a Failure status or move to
operational status provided no othe r pr oble m was
detected?
Table 4-1 Setup Command Parameters (continued)
Parameter Definition
Page 26
4-6
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 4 Connect the Management Interfaces and Perform Initial System Co nfiguration
Perform the Initial System Configuration
To accept the default value, press Enter .
If you need mo re i nfo rma tio n abo ut any pa rame ter, type ? and pr ess Enter .
A help message w ill ap pe ar d esc ribi ng t he expec ted f orm at of the p aram ete r and a ny ot her requirements.
T o ju mp to t he end of th e setup d ialog a t any point, ac ceptin g all re maining def ault values, press ^z .
In certain cases, there will be two or more logically related parameters within a menu. In these
situations, it is not permitted to jump to the end of the setup dialog until all related parameters are configured. If you t r y to jum p t o t he e nd of t he s et up dia log, the fol lowing me ssage w ill appe ar:
“Sorry, Skipping is not allowed at this stage.”
Certain groups of re late d par amet ers, su ch a s t im e, da te , and SN T P set tin gs, fo rm sub -dia logs or
menus within the setup dialog. You may skip an entire menu, thereby accepting all default values for the parameters within the menu.
Each group of rel ated pa rame ter s i s p refac ed by a qu esti on , ask i ng whet her yo u want t o e nte r t he menu. To skip the menu, answer no (“n” ) to the q ues tion.
Example
Would you like to enter the SNMP configuration menu? n
To abort the setu p d i alog at any poi nt witho ut m aki ng any c onfigura tio n cha ng es, p re ss ^c . All
changes already entered will be lost, with the exception of time settings.
Step 1: Configuring Initial Settings
Verify the following initial settings for the SCE 1000:
IP address
Subnet mask
Default gateway
All values are Internet addresses of the form ‘X.X.X.X’, where each letter corresponds to a decimal number between 0 and 25 5.
Step 1 Configure the IP address.
The current IP ad dres s is displa yed.
To accept the displayed value, press press Enter.
To change the value, type the desired value in the format “x.x.x.x” and pres s pr es s Ent er.
Step 2 Configure the subnet mask.
The current sub net ma sk is displa yed.
To accept the displayed value, press press Enter.
To change the value, type the desired value in the format “x.x.x.x” and pres s pr es s Ent er.
Step 3 Configure the default gateway.
The current IP address of the default gateway is displayed.
To accept the displayed value, press press Enter.
Page 27
4-7
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 4 Connect the Management Interfaces and Perform Ini tial System Configuration
Perform the Initial System Configuration
To change the value, type the desired value in the format “x.x.x.x” and pr es s pr es s Ent er.
Example
The following example disp lays a typ ica l c onfigura tio n of th e IP ad dre ss (10 .1. 5.109 ), sub net mask (255.255.0.0), and default gateway (10.1. 1.3).
Since the IP address and the subnet mask are related, when the IP address is changed, there is no longer a default value of the subnet mask, and it must be entered explicitly.
Enter IP address [10.1.1.201]:10.1.5.109 Enter IP subnet mask:255.255.0.0 Enter IP address of default gateway [10.1.1.3]:
Step 2: Configuring the Hostname
The hostname is used to identify the SCE 1000. It appears as part of the CLI prompt and is also returned as the value of the MIB-II object sysName.
The maximum length is 20 characters. The default hostna me i s SCE 1 000 .
Step 1 Specify the hostname for the SCE platform.
The default hostname is di spla yed.
To accept the displayed value, press press Enter.
To change the value, type any desired character string and press press Enter.
Enter hostname [SCE 1000]:
Step 3: Setting the Passwords
Configure the passwords as follows:
Set the password for each authorization level (User, Admin, Root).
Enable/disabl e password en crypti on. When password encryp tion is enab led , it encr ypts the
previously entered passwords.
Note Passwords are needed for all authorization levels in order to prevent unauthorized users from accessing
the SCE 1000. Admin level should be used by the network administrator. Root level is for use by Cisco technician.
Passwords must meet the following criteria:
Minimum length — 4 characters
Maximum lengt h — 10 0 ch ar act er s
Begin with an alpha character
Page 28
4-8
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 4 Connect the Management Interfaces and Perform Initial System Co nfiguration
Perform the Initial System Configuration
May contain only printable characters
Note Passwords are case sensitive.
Note The default password for all levels is “ Cisco ”.
Step 1 Configure the User password
The default User password is displayed.
To accept the displayed value, press press Enter.
To change the value, type the desired string and press press Enter.
Step 2 Configure the Admin password.
The default Admin password is displa yed.
To accept the displayed value, press press Enter.
To change the value, type the desired string and press press Enter.
Step 3 Configure the Root password.
The default Root password is displayed .
To accept the displayed value, press press Enter.
To change the value, type the desired string and press press Enter.
Step 4 Configure password encryption. By default, password enc ryption is not enabled.
To disable password encryption, press Enter.
To enable password enc ryp tion, type y and pr ess Enter.
EXAMPLE:
Following is an example o f ch angi ng all p as sword s. Password encr ypt ion is n ot en abl ed ( de fault).
Enter a User password [Cisco]: userin Enter an Admin password [Cisco]: mng123 Enter a Root password [Cisco]: cistech Enable passwords encryption? [no]:
Step 4: Configuring Time Settings
The time settings menu configures all time and date related parameters in the system. The time settings menu includes the following:
Time zone
Local time
Date
SNTP menu
Page 29
4-9
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 4 Connect the Management Interfaces and Perform Ini tial System Configuration
Perform the Initial System Configuration
You must en ter the time setting me nu to configur e SNTP settings. You may choose to skip the time settings menu if you wish to accept all default values.
Note Unlike all other settings d efined in the s ystem c onfigura tion, se ttin g the time is done im me diat el y an d
not at the end of the setup process.
SUMMARY STEPS
1. Enter the time settings menu.
2. Configure the time zone name.
3. Specify the offset from UTC.
4. Confirm the local time and date.
5. Enter the SNTP configuration menu.
6. Configure the SNTP broadcast client. By default the SNTP broadcast client is not enabled.
7. Define the time interval between unicast upd ates .
8. Specify an IP address for the SNTP unicast server.
DETAILED STEPS
Step 1 Enter the time settings menu.
Would you like to enter the Time settings menu? [no]: y
Type y and press press Enter.
Step 2 Configure the time zone name.
Type the time zone abbreviation and press pr ess Enter.
Enter time zone name [UTC]: CET
Step 3 Specify the offset from UTC.
Type the minutes offset from UTC and press pre ss Enter.
Enter time zone minutes offset from UTC: 60
Step 4 Confirm the local time and date.
The local time and date are displ ayed, a nd you are asked w hether you want to ch ange the m
The local time and date is 15:00:01 CET FRI 01 July 2002 Would you like to set a new time and date? [no]:
If the time and date are correct, press
Enter
and go to Step 5.
If the time and date are not correct, answer yes to the above question, and press press Enter.
Would you like to set a new time and date? [no]: y Confirm your response and type the new time and date. This change will take effect immediately both on the system clock and calendar; it will also set the time zone you entered. Are you sure? [yes/no]: y Enter new local time and date: 14:00:01 1 July 2002 Time zone was successfully set. The system clock and the calendar were successfully set.
Step 5 Enter the SNTP configuration menu.
Page 30
4-10
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 4 Connect the Management Interfaces and Perform Initial System Co nfiguration
Perform the Initial System Configuration
If you do not wish to configure the SNTP, skip the rest of this section and go to . To enter the SNTP configuration dialog, type y, and press Enter
Would you like to enter the SNTP configuration menu? [no]: y
Step 6 Configure the SNTP broadcast client. By default the SNTP broadcast client is not enabled.
To disable the SNTP broadcast client, press press Enter.
To enable the SNTP broadcast client, type y and press press Enter.
Enable SNTP broadcast client? [no]:
Step 7 Define the time interval between unicast upd ates .
To accept the displayed default value, press press En ter.
Enter time interval in seconds between unicast updates [1024]:
Step 8 Specify an IP address for the SNTP unicast server.
Type in the hostna me o r the IP ad dress in the for m x. x. x .x , and pr ess Enter
Would you like to configure SNTP unicast servers? [no]: y Enter IP address or hostname of SNTP unicast server: 10.1.1.1
EXAMPLE:
Following is a sample time setting dialog. In additio n to setting the time z one, time and da te are changed, and SNTP unicast updates are configured.
Would you like to enter the Time settings menu? [no]: y Enter time zone name [UTC]: ISR Enter time zone minutes offset from UTC: 120 The local time and date is 15:35:23 ISR FRI July 19 2002 Would you like to set a new time and date? [no]: y This change will take effect immediately both on the system clock and the calendar; it will also set the time zone you entered. Are you sure? [yes/no]: y Enter new local time and date: 14:35:23 19 July 2002 Time zone was successfully set. The system clock and the calendar were successfully set. Would you like to enter the SNTP configuration menu? [no]: y Enable SNTP broadcast client? [no]: y Enter time interval in seconds between unicast updates [900]: Would you like to configure SNTP unicast servers? [no]: y Enter IP address or hostname of SNTP unicast server: 10.1.1.1
Step 5: Configuring the DNS Settings
The DNS configuration menu defines the IP address of the domain name server, which is used for DNS lookup, as well as the default domain name, which is used to complete unqualified host names.
You may c ho ose t o ski p the D NS configura tio n me nu if y ou wish t o accep t a ll de fault values.
SUMMARY STEPS
1. Enter the DNS set tings me nu.
2. Enable or disable DNS look up.
Page 31
4-11
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 4 Connect the Management Interfaces and Perform Ini tial System Configuration
Perform the Initial System Configuration
3. Type the default d omai n name to be us ed , an d p re ss pre ss E nte r.
4. Configure the primary domain name server .
5. Configure any additional do main nam e servers.
6. Exit the dialog.
DETAILED STEPS
Step 1 Enter the DNS set tings me nu.
Would you like to enter the DNS configuration menu? [no]: y
Type y and press pr ess E nter. The DNS settings dialog begins.
Step 2 Enable or disable DNS look up.
To enable DNS lo okup, pr ess press En ter.
To disable DNS lookup, type n and press press Enter.
Enable IP DNS-based hostname translation? [yes]:
If you choose to disable DNS lookup, skip the rest of this section and go to . The rest of the dialog is not presented, as it is ir rel evant when DNS lo okup is disa bled .
Step 3 Type the default d omai n name to be us ed , an d p re ss pre ss E nte r.
Note that there is no default domain name. You ma y accept th e default dom ain name or enter a new one.
Enter default domain name []:
Step 4 Configure the primary domain name server .
Type the IP addre ss of t he pr ima ry dom a in n ame server a nd p re ss pre ss Ent er.
Enter Primary DNS IP address:
Note that there is no default for this parameter.
Step 5 Configure any additional do main nam e servers.
You may configure up to three domain servers.
Would you like to add another Name Server? [no]:
To exit the DNS settings dialog, press press Enter.
To add another d omai n server, type y an d press pre ss Ente r.
You ar e aske d to e nter the IP add re ss o f th e next do mai n nam e se rver.
Enter Secondary DNS IP address:
Step 6 Exit the dialog.
When IP addresses for all servers have been entered, exit the dialog by pressing press Enter.
Would you like to add another Name Server? [no]:
EXAMPLE:
Following is a sample DNS configuration dial og. Th e default dom ain name is pcube. com, and t he IP address of the D omai n N ame Se rver is 10 .1.1. 230 .
Page 32
4-12
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 4 Connect the Management Interfaces and Perform Initial System Co nfiguration
Perform the Initial System Configuration
Would you like to enter the DNS configuration menu? [no]: y Enable IP DNS-based hostname translation? [yes]: Enter default domain name []: pcube.com Enter Primary DNS IP address: 10.1.1.230 Would you like to add another Name Server? [no]:
Step 6: Configuring the RDR Formatter Destination
The SCE 1000 passes Raw Data Records (RDRs) to an external collection system v ia the RDR-Formatter. In order for the data to reach the correct location, the IP address of the external collection system a nd its port numbe r must be configu red.
Step 1 Enter the RDR formatter configuration menu.
Would you like to enter the RDR-formatter configuration menu? [no]: y
Type y and press press Enter. The RDR-formatter de stinatio n dialog begi ns.
Step 2 Specify the IP address of the RDR-formatter destination.
Type the IP addre ss of t he RD R-for ma tter dest inatio n a nd pr e ss pre ss Ent er.
Enter RDR-formatter destination’s IP address:
Note that there is no default for this parameter.
Step 3 Specify the TCP port number of the RDR-formatter destination.
Type the TCP port number of the RD R-form atter de stination and press pr ess Enter. Note that there is no default for this parameter.
Enter RDR-formatter destination’s TCP port number:
EXAMPLE:
Following is a sample RDR-formatter configuration dialog, assigning the IP address and TCP port number.
Would you like to enter the RDR-formatter configuration menu? [no]: y Enter RDR-formatter destination’s IP address: 10.1.1.230 Enter RDR-formatter destination’s TCP port number: 33000
Step 7: Configuring Access Control Lists (ACLs)
Information Abou t Acce ss C ontro l L ists, pag e 4-12
Examples, page 4-15
Information About Access Control Lists
Configuring ACLs, page 4-13
Entry Formats, page 4-13
Order of Entries, pa ge 4-13
Page 33
4-13
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 4 Connect the Management Interfaces and Perform Ini tial System Configuration
Perform the Initial System Configuration
Configuring ACLs
The SCE 1000 can be configured with Acc ess Contro l Lists (ACLs), which are used to permit or de ny incoming connections on any of the manage ment int erfaces.
Note ACL #0 is a pre-defined list that permits access to all IP addresses.
Configuration of access control lists is done in two stages:
1. Create the access control lists.
You may create 99 ACLs with a maximum of 20 entrie s per list. Each entry cons ists of an IP address, and an indication of whether access is permitted or denied to this IP address.
2. Assign the ACLs to the appropriate mana gement interface. (See )
The dialog permit s yo u to sk ip the crea ti on/e dit ing of the ACLs and go dire c tly to a ssigning ACLs to the manageme nt in terfa ces.
Entry Formats
Each ACL may permit/deny access to any IP address, one or more ranges of IP addresses, or one or more individual IP address. Three ent ry form ats are available to suppor t these opt ions :
Any IP address — Type the word “any”. Any IP addr ess w ill be pe rm itte d or de nie d acce ss.
Range of IP addresses — Type the beginning IP address in the desired range, then enter the wildcard
bits that define the range. This wild ca rd f u nc ti on s l ike a r everse m a sk , in that all “ 1” b its in the w ild ca r d in d ica t e th e
corresponding bit in the IP address should be ignored. All other bits must match the corresponding bit in the specified IP address. Refer to the table below for examples.
Each range of IP add re sses c an be con figured to b e pe rm itte d or de nie d ac cess.
Individual IP address— Type the desired IP address, then enter the wildcard bits 0.0.0.0.
Each individual IP addr e ss can b e co nfigured t o be pe rmi tted or de nie d ac ce ss.
Order of Entries
The order of the entries in the list is important. The entries in the list are tested sequentially, and the action is determined b y the f irst entr y that matches th e connec ting IP address. There fore, when the e ntry “any” appear s i n an Ac ce ss C ontr ol L is t, a ll su cc e ed in g e ntr ie s ar e irre l evant.
Consider two hypothetic al ACLs containing the same entries in a differe nt order. The following list would permit access to all IP addresses, including 10.1.1.0:
permit any deny 10.1.1. 0
Note that the above list could not actually be created using the setup utility, since after the “any” entry, no other entries could be added to the list.
Table 4-2 IP address/Wildcard bit examples
Initial IP address Wildcard bits Range
10.1.1.0 0.0.0.255 10.1.1.0–10.1.1. 255
10.1.1.0 0.0.0.63 10.1.1.0–10.1.1.63
10.1.1.0 0.0.0.0 10.1.1.0 (individual entry)
Page 34
4-14
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 4 Connect the Management Interfaces and Perform Initial System Co nfiguration
Perform the Initial System Configuration
The following list will deny access to IP address 10.1.1.0, but permit access to all others:
deny 10.1.1. 0 permit any
If no entry in the assigned Access Control List matches the connection, or if the Access Control List is empty, the default action is deny.
To create the access control lists, complete the following steps:
SUMMARY STEPS
1. Enter the Access Control Lists configuration menu.
2. You have the option of cre ating or modify ing Acc ess Control Li sts, or skippi ng this sect ion and
proceeding directly to assign the existi ng ACLs to the desired ma nageme nt interface s.
3. Type the number of the Ac cess C ont rol Li st t o be c onfigured (1 t h rough 99) a nd pr ess Enter .
4. Begin adding entries to the selected list.
5. Type the IP address to be added to this list, and press pre ss Enter.
6. If you entered a spec ific IP addr ess, ent er t he w ild card b its t o d efine a r a nge o f I P a dd resses and
press Enter . (See Entry Formats, page 4-13.)
7. The maximum number of e ntrie s in an ACL is 20.
8. When all entries are add ed to on e list, yo u are aske d whet he r you w oul d lik e to cr eate an othe r ACL.
You may d efine u p to 99 ACLs.
9. Restrict IP access to the SCE 1000 by assign ing the appr opriate ACL.
10. Restrict Telnet access to the SCE 1000 by a ssigni ng t he ap pro pria te ACL.
DETAILED STEPS
Step 1 Enter the Access Contr ol L ists c onfiguratio n m enu.
Would you like to enter the Access lists configuration menu? [no]:y
Type y and press press Enter. The Access Control Lists co nfiguration dia log begins.
Step 2 You have the option of cre ating or modify ing Acc ess Control Li sts, or skippi ng this sect ion and
proceeding directly to assign the existi ng ACLs to the desired ma nageme nt interface s.
Would you like to create new Access lists or modify existing lists? [no]: y
If you choose not to create or edit Access Control Lists, skip to .
Step 3 Type the number of the Ac cess C ont rol Li st t o be c onfigured (1 t h rough 99) a nd pr ess Enter .
Note that there is no default for this parameter.
Step 4 Begin adding entries to the selected list.
Indicate whether this entry is permitted access or denied access.
To permit access press press Enter.
To deny access type n and p ress p ress Enter.
Step 5 Type the IP address to be added to this list, and press pre ss Enter.
Note that there is no default for this parameter.
Enter IP address or the word ‘any’ to denote any IP address:
Page 35
4-15
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 4 Connect the Management Interfaces and Perform Ini tial System Configuration
Perform the Initial System Configuration
Step 6 If you entered a spec ific IP addr ess, ent er the w ild card b its to d efine a ra nge of I P a dd resses a nd press
Enter . (See Entry Formats, page 4-13.) To define an individual IP address, type 0.0.0.0 and press Enter . There is no default fo r this para mete r.
Enter wildcard bits:
Step 7 The maximum number of e ntrie s in an ACL is 20.
If the “any” option was used, no other IP addresses may be a dded to the list.
To add more entries, type y and press
Enter
Would you like to add another entry to this list? [no]:y
Enter up to 20 entries as described in ste p 5 and step 6.
When all entries have been added, press
Enter
Would you like to add another entry to this list? [no]:
Step 8 When all entries are added to one list, you are asked whether you would like to create another ACL. You
may define up to 99 ACLs.
To create another ACL, type y and press
Enter
Would you like to configure another list? [no]: y
Enter up to 20 IP addresses in this new ACL, as described in step 5 and step 6.
When all ACLs have been created, press press Enter.
Would you like to configure another list? [no]:
You ar e now prompted to assi gn the desire d ACLs to restrict IP and Telnet access.
Step 9 Restrict IP access to the SCE 1000 by assign ing the appr opriate ACL.
Type the number of the ACL to be a ssigne d to I P a ccess a nd pr ess press E nter. To accept the default ACL, press press Enter.
Enter IP access-class [0]:
Step 10 Restrict Telnet access to the SCE 1000 by a ssigning the ap prop riat e ACL.
Type the number of the ACL to be assigned to the Telnet interface and press
Enter.
To accept the default ACL, press
Enter.
Enter Telnet access-class [0]: 2
Examples
EXAMPLE 1:
This example illustrates a common access control scenario. Let us assume the following:
We want to permit every station to access the SCE platform on the management port (for example
ping, SNMP polling etc.) .
We want to restrict Telnet access to only a few permitted stations.
We therefore ne ed to cr eat e two acce ss co ntro l lis ts:
For general IP access — permit access to all IP addresses.
Page 36
4-16
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 4 Connect the Management Interfaces and Perform Initial System Co nfiguration
Perform the Initial System Configuration
For Te lnet — permit access to the specified IP address, and deny to all others.
ACL #1 = permit any IP address. Assign to IP access. ACL #2 = permit access to 10.1.1.0, 10.10.10. 1, deny to all other s. Assign t o Telnet access.
Would you like to enter the Access lists configuration menu? [no]: y Would you like to create new Access lists or modify existing lists? [no]: y Enter ACL number: 1 Does this entry permit access? [yes]: Enter IP address or the word ‘any’ to denote any IP address: any This entry matches every IP address, no use in adding more entries to this list. Would you like to configure another list? [no]: y Enter ACL number: 2 Does this entry permit access? [yes]: Enter IP address or the word ‘any’ to denote any IP address: 10.1.1.0 Enter wildcard bits: 0.0.0.0 Would you like to add another entry to this list? [no]:y Does this entry permit access? [yes]: Enter IP address or the word ‘any’ to denote any IP address: 10.10.10.1 Enter wildcard bits: 0.0.0.0 Would you like to add another entry to this list? [no]:y Does this entry permit access? [yes]:n Enter IP address or the word ‘any’ to denote any IP address: any This entry matches every IP address, no use in adding more entries to this list. Would you like to configure another list? [no]: Enter IP access-class [0]: 1 Enter Telnet access-class [0]: 2
EXAMPLE 2:
This example skips t he first se ction of the d ial og (c r eat ing/mo di fyin g), and pr ocee ds dire ct ly to as sig n existing ACLs.
Would you like to enter the Access lists configuration menu? [no]: y Would you like to create new Access lists or modify existing lists? [no]: Enter IP access-class [0]: 10 Enter Telnet access-class [0]: 22
Step 8: Configuring SNMP
Managing the SCE 1000 is possible al so via a Network Ma nagement System (NMS) t hat suppor ts SNMP. By defaul t, SN MP is d isab led on the SCE 1 000 .
To enable SNMP management you must configure the following basic SNMP parameters:
SNMP traps status and managers.
Community strings (where an SNMP community string is a text string that acts like a password to
permit access to the SNMP agen t on the SCE 100 0).
SUMMARY STEPS
1. Enter the SNMP configuration menu.
2. Enable SNMP manageme nt.
3. Configure the SNMP GET community.
4. Type the SNMP GET com mun ity na me an d p ress p ress E nte r.
5. Assign an access list to restr ict the SNMP ma nage ment sta tions t hat ma y use this G ET co mm unity.
6. Configure additional GET communities.
Page 37
4-17
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 4 Connect the Management Interfaces and Perform Ini tial System Configuration
Perform the Initial System Configuration
7. To add more entries, do not accept the default::
8. Enter up to 20 SN MP GET com mun itie s as de scri bed in step 3 .
9. When all entries have been added, accept the default:
10. Configure the SNMP SET community.
11. Type the SNMP SET community name an d press press Ente r.
12. Assign an access list to restrict the SNMP management stations that may use this SET community.
13. Configure additional SET communities.
14. To add more entries, do not accept the default::
15. Enter up to 20 SN MP SET c om muni ties as descr ibe d in ste p 5 .
16. When all entries have been added, accept the default:
17. Configure the SNMP trap managers.
18. Enter the SNMP tra p ma na gers menu .
19. Configure the trap manager IP address
20. Configure the trap manager community string
21. Configure the trap manager SNMP version.
22. Configure additional trap managers.
23. To add more entries do not accept the default:
24. Enter up to 20 trap managers as descr ibed in step 7.
25. When all entries have been added, accept the default:
26. Configure the Authentication Failure trap status.
27. Configure the SCE enterprise trap status.
28. Specify the system administrator.
DETAILED STEPS
Step 1 Enter the SNMP configuration menu.
Would you like to enter the SNMP configuration menu? [no]: y
Type y and press press Enter. The SNMP configuration dial og begins.
Step 2 Enable SNMP manageme nt.
Type
y and press press Enter.
Enable SNMP management? [no]: y
If you choose to disable SNMP management, skip the rest of this section and go to . The rest of the dialog is not presente d, a s it is i rrelevant when SNMP ma nage me nt is di sabl ed .
Step 3 Configure the SNMP GET community.
a. Type the SNMP GET community name an d p ress p ress E nte r.
The SNMP agent that resides in side the SCE 1000 will respond onl y to GET requ ests that use th is community string.
Enter SNMP GET community name:
Note that there is no default for this parameter.
Page 38
4-18
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 4 Connect the Management Interfaces and Perform Initial System Co nfiguration
Perform the Initial System Configuration
b. Assign an access list to r estr ict the SNMP ma nage ment sta tions t hat ma y use t his G ET co mm unity.
T ype a number (1 through 99) or type “0” to permit access to all IP addresses, and press press Enter.
Enter Access list number allowing access with this community string, use ‘0’ to allow all:
Step 4 Configure additional GET communities.
The maximum number of G ET commu nities is 20.
a. To add more entries, do not accept the default::
Would you like to add another SNMP GET community? [no]:
Type y and press press Ent er.
b. Enter up to 20 SN MP GET com mun ities a s descr ibed in step 3 . c. When all entries have been added, accept the default:
Would you like to add another SNMP GET community? [no]:
Press Enter to accept.
Step 5 Configure the SNMP SET community.
a. Type the SNMP SET community name and press press Enter.
The SNMP agent that reside s inside the SCE 1000 will respo nd only to SET req uests that use this community string.
Enter SNMP SET community name:
Note that there is no default for this parameter.
b. Assign an access list to restrict the SNMP management stations that may use this SET community.
T ype a number (1 through 99) or type “0” to permit access to all IP addresses, and press press Enter.
Enter Access list number allowing access with this community string, use ‘0’ to allow all:
Step 6 Configure additional SET communities.
a. To add more entries, do not accept the default::
Would you like to add another SNMP SET community? [no]:
Type y and press press Ent er.
b. Enter up to 20 SN MP SET c ommu ni ties as descr ibe d in ste p 5 . c. When all entries have been added, accept the default:
Would you like to add another SNMP SET community? [no]:
Press Enter to accept.
Step 7 Configure the SNMP trap managers.
a. Enter the SNM P tra p ma nage rs menu .
Would you like to configure SNMP trap managers? [no]: y
Type y and press pr ess E nter. The SNMP trap m a nager s d i alog begins. If you choose not to configure SNMP trap managers, the dialog skips to the authentication failure
trap status. (See step 9.)
b. Configure the trap manager IP address
Enter SNMP trap manager IP address:
Type the trap manager community string and press press Enter.
Page 39
4-19
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 4 Connect the Management Interfaces and Perform Ini tial System Configuration
Perform the Initial System Configuration
Note that there is no default for this parameter.
c. Configure the trap manager community string
Enter SNMP trap manager community string:
Type the trap manager community string and press press Enter. Note that there is no default for this parameter.
d. Configure the trap manager SNMP version.
Enter trap manager SNMP version:
Type the number of the trap manage r SNMP version (1 or 2c) and press press En ter. Note that there is no default for this parameter.
Step 8 Configure additional trap managers.
The maximum number of tra p manage rs is 20.
a. To add more entries do not accept the default:
Would you like to add another SNMP trap manager? [no]:
Type y and press press Ent er.
b. Enter up to 20 trap manage rs as descri bed in step 7. c. When all entries have been added, accept the default:
Would you like to add another SNMP trap manager? [no]:
Press Enter to accept.
Step 9 Configure the Authentication Failure trap status.
To disable the Authentication Failure trap, press press Enter.
To enable the Authentication Failure trap, type y and press press Enter.
Enable the ‘Authentication Failure’ trap [no]:
Step 10 Configure the SCE enterprise trap status.
To disable the SCE enterprise traps, type n press press Ent er.
To enable the SCE enterprise traps, type y and press press Enter.
Enable the SCE enterprise traps []:
Step 11 Specify the system administrator.
Type the name of the system admi nistrat or and press pre ss Enter. Note that there is no default for this parameter.
Enter system administrator contact name []:
EXAMPLE:
Following is a sample SNM P c on figurat ion, configu ring one tr ap man ag er, one GET com mu nit y, and one SET community, and enabling the authentication failure trap, as well as all enterprise traps.
Would you like to enter the SNMP configuration menu? [no]: y Enable SNMP management? [no]: y Enter SNMP GET community name[]: public Enter Access list number allowing access with this community string, use ‘0’ to allow all: 0 Would you like to add another SNMP GET community? [no]: Enter SNMP SET community name[]: private Enter Access list number allowing access with this community string, use ‘0’ to allow all: 2
Page 40
4-20
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 4 Connect the Management Interfaces and Perform Initial System Co nfiguration
Perform the Initial System Configuration
Would you like to add another SNMP SET community? [no]: Would you like to configure SNMP trap managers? [no]: y Enter SNMP trap manager IP address: 10.1.1.253 Enter SNMP trap manager community string: public Enter trap manager SNMP version: 2c Would you like to add another SNMP trap manager? [no]: Enable the ‘Authentication Failure’ trap [no]: y Enable SCE enterprise traps []: y Enter system administrator contact name []: John Smith
Step 9: Configuring the Topology-Dependent Parameters
About the Topology-Dependent Parameter s, page 4-20
Examples, page 4-21
About the Topology-Dependent Parameters
The topology configuration me nu is a se rie s of g uid ed que sti ons rel at ing to the deploym en t of the SCE 1000 in the network and its mod e of operat ion. Values for the parameters are configured based on the user answers.
The correct value for each parameter must be ascertained before configuring the system to make sure that the system will function in the desired manner.
There are th ree top ol ogy- rel ate d para met er s:
Connection mode — Can be either I nlin e or R eceive-only, depending on the physic al inst all ation
of the SCE 1000.
Bypass state when the SCE 1000 is not operational (on-failure) — This parameter determines
whether the system cuts the traffic or bypasses it when the SCE 1000 has failed.
Status after reboot caused by fatal error or abnormal shutdown — This parameter determines
whether the SCE 1000 returns to normal operational state after a failure.
The procedure desc ribe d bel ow is a hypo theti cal prese nt ation o f al l t he q ue stio ns in t he t o pology
configuration. In actual practice, it is impossible for all questions to be presented in any one configuration, as this part of the dialog is not linear like the other sections, but branches depe nding on the parameter values entered.
Study the examples th at fol low to un de rsta nd th e proc ed ure f or various t opol ogie s.
Step 1 Enter the topology c onfigurati on m enu.
Would you like to enter the Topology configuration menu? [no]: y
Enter your password i f pr om pted .
Type
y and press press Enter.
The topology configuration di alog b egins.
Step 2 Specify the co nnec tion mode .
To define inline connection mod e, p ress p re ss Ente r.
To define receive-only connection mode, type 2 and press press Enter.
Enter Connection mode: 1- inline 2- receive-only Enter your choice [1]:
Page 41
4-21
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 4 Connect the Management Interfaces and Perform Ini tial System Configuration
Perform the Initial System Configuration
Step 3 Specify the On-failure link be havior.
To specify Bypass , press pre ss Enter.
To specify Cuto ff , type 2 and press pr ess Enter.
Enter On-failure behavior: 1- bypass 2- cutoff Enter your choice [1]:
Step 4 Specify the admin status of the SCE 1000 afte r abnorma l boot.
To specify Not-Operational status after abnor mal boot , pr ess pr ess Ent er.
To specify Operational status after abnormal b oot, t yp e 1 and pr es s pres s E nt er.
Enter admin status of the SCe after abnormal boot: 1- Operational 2- Not-Operational Enter your choice [1]:
Examples
The following exampl es pre sen t the p roce dur e for c on figurin g t he top ol ogy-re l ated pa ra met ers f or various topologies. Refer the for a summary of appropriate values for the parameters for each topology.
EXAMPLE 1:, page 4-21
EXAMPLE 2:, page 4-21
EXAMPLE 3:, page 4-22
EXAMPLE 1:
Following is a sample topology configuration for a t opology using a n external swit ch. All other parameter values are automatically assigned by the system as follows:
Link bypass mode on-fai lure — Bypass
Admin status of the SCE after abnormal boot — Operational
Would you like to enter the Topology configuration menu? [no]: y Enter Connection mode: 1- inline 2- receive-only Enter your choice [1]: 2
EXAMPLE 2:
Following is a sample topology configuration for a non-r edund ant bump-in- the-w ire (inline ) topolo gy. All values are the system default values, so it is not necessary to type in the response. Simply press enter at each line.
Connection mode — Inline
For a non-redundant topo logy, link bypass on-failure shou ld be Bypa ss, so tha t tra ffic continues to
flow through the link.
After operation of the system resumes, and the SCE 1000 reboots, the SCE 1000 will resume
operation. (Admi n st atu s a fte r ab norma l re bo ot i s Oper at ion al. )
Would you like to enter the Topology configuration menu? [no]: y Enter Connection mode: 1- inline
Page 42
4-22
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 4 Connect the Management Interfaces and Perform Initial System Co nfiguration
Perform the Initial System Configuration
2- receive-only Enter your choice [1]: Enter On-failure behavior: 1- Bypass 2- Cutoff Enter your choice [1]: Enter admin status of the SCe after abnormal boot: 1- Operational 2- Not-Operational Enter your choice [1]: Data collection for the system configuration is completed.
EXAMPLE 3:
Following is a sample topology configuration for a re dunda nt inline t opology.
Connection mode — Inline
For a redundant topology, link bypass on-failure should be Cutoff, so that operation switc hes to the
backup link.
After operation of the system resumes, and the SCE 1000 reboots, the SCE 1000 will resume
operation. (Admi n st atu s a fte r ab norma l re bo ot i s Oper at ion al. )
Would you like to enter the Topology configuration menu? [no]: y Enter Connection mode: 1- inline 2- receive-only Enter your choice [1]: 2 Enter On-failure behavior: 1- Bypass 2- Cutoff Enter your choice [1]:2 Enter admin status of the SCE after abnormal boot: 1- Operational 2- Not-Operational Enter your choice [1]: Data collection for the system configuration is completed.
Step 10: Completing and Saving the Configuration
When you have completed the entire configuration, the system checks for errors. If errors are found, a warning message app ears. W hen t h e co nfigur ation is err or-free, y ou ma y ap ply an d save it.
To complete and save the configuration, complete the following steps:
SUMMARY STEPS
1. Review the new configuration.
2. View errors (if any).
3. Apply and save the configuration.
4. Confirm saving and applying the configuration.
5. Save the configuration to a remote location.
6. This completes the pro cedur es for i nitial con figurat ion o f the SCE 1 000 pl at form.
Page 43
4-23
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 4 Connect the Management Interfaces and Perform Ini tial System Configuration
Perform the Initial System Configuration
DETAILED STEPS
Step 1 Review the new configuration.
The system informs you that data collection is complete. We recommend that you view the entire new configuration before it is applied. Type
y and press press Enter.
Note that there is no default. If there are no errors, go to step 3.
Data collection for the system configuration is completed. Would you like to view the new configuration before it is applied? [yes/no]: y
Step 2 View errors (if any).
If any errors are detected, you may choose to view them. Press press Enter.
Found errors in the new configuration, would you like to view them? [yes]: The following errors were found: Warning - RDR formatter destination 10.1.1.1 is not allowed in the IP access-class.
Step 3 Apply and save the configuration.
You ar e aske d w het her to app ly a nd save the co nfigurati on.
Apply and Save this configuration? [yes/no]:
To apply and save the co nfigurat ion, ty pe y and press press Enter.
Setup procedure aborted, no configuration changes made.
If the setup is aborted, the dialog is ended.
Step 4 Confirm saving and applying the configuration.
If there are no errors, the system r eq u est s confirmation of either a yes or no an s we r, to prevent mistakes . Type the appropriat e answer (y or n) and pre ss press Ente r.
The running configuration would be overwritten by the changes you have just entered, are you sure? [yes/no]: The selected action is carried out by the system.
The selected action is carried out by the system.
If the apply and save action is not confirmed ( no ), the setup is aborted.
Setup procedure aborted, no configuration changes made.
If the apply and save action is confirmed ( yes ), the configura tion is ap plied and saved.
The new running configuration will be saved to the startup configuration.
Step 5 Save the configuration to a remote location.
If the configuration was applied and saved, you may also save a backup copy to a file at a remote station.
Do you want to save a copy of the startup configuration file in a remote station? [no]:
To save the configuration to a remote station, type y and press press Enter. The system will ask for FTP path:
Enter a full FTP path of the remote destination:
Step 6 This completes the pro cedur es for i nitial con figurat ion o f the SCE 1 000 pl at form.
The system informs you that the configur ation is com plete .
Committing configuration... Configuration completed successfully. Saving configuration... Writing general configuration file to temporary location...
Page 44
4-24
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 4 Connect the Management Interfaces and Perform Initial System Co nfiguration
Perform the Initial System Configuration
Backing-up general configuration file... Copy temporary file to final location... Done!
Examples
EXAMPLE 1:, page 4-24
EXAMPLE 2:, page 4-24
EXAMPLE 3:, page 4-24
EXAMPLE 1:
Following is an example of a configuration that the user aborted due to errors detected in the configuration.
Note that no confirmation is requested for the decision to abort the setup. Had there been no errors, confirmation would have been requested befor e aborting .
Data collection for the system configuration is completed. Would you like to view the new configuration before it is applied? [yes/no]: n Found errors in the new configuration, would you like to view them? [yes]: y The following errors were found: Warning - RDR formatter destination 10.1.1.1 is not allowed in the IP access-class. Warning - default Gateway 10.1.1.1 is not allowed in the IP access-class. Warning - IP Access list (1) conflicts with Telnet Access list (2) as follows: Access list 2 permits all addresses while Access list 1 denies it. Apply and Save this configuration? [yes/no]: n Setup procedure aborted, no configuration changes made.
EXAMPLE 2:
Following is an example of a configuration tha t was applied an d saved to the startup co nfiguration a s well as to an FTP site.
Although not d emonst r ate d in th is examp le, it is re co mmen de d tha t you always view th e c onfigura tio n before applying i t.
Data collection for the system configuration is completed. Would you like to view the new configuration before it is applied? [yes/no]: Apply and Save this configuration? [yes/no]: y (New configuration would be displayed here) The running configuration would be overwritten by the changes you have just entered, are you sure? [yes/no]:y The new running configuration will be saved to the startup configuration. Do you want to save a copy of the startup configuration file in a remote station? [no]:y Enter a full FTP path of the remote destination: ftp://vk:vk@10.1.1.253/h:/copyofstartup.txt Committing configuration... Configuration completed successfully. Saving configuration... Writing general configuration file to temporary location... Backing-up general configuration file... Copy temporary file to final location... Done!
EXAMPLE 3:
Following is an example of a configuration tha t was aborted , altho ugh no errors w ere detec ted.
Page 45
4-25
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 4 Connect the Management Interfaces and Perform Ini tial System Configuration
Connect the Management Interface
Data collection for the system configuration is completed. Would you like to view the new configuration before it is applied? [yes/no]: Apply and Save this configuration? [yes/no]: n The changes you have just entered would be discarded, are you sure? [yes/no]:y Setup procedure aborted, no configuration changes made.
Connect the Management Interface
Figure 4-2 Cabling the Management Port
Note By default, the management port is configured to auto-negotiation enabled.
The SCE 1000 ha s two ma nage me nt ports , labe led M ng 1 an d M ng 2. U se the Mn g 1 po rt.
Step 1 Plug the Ethernet cable provided (with attached RJ-45 connector) into the Mng 1 port on the front panel
of the SCE 1000.
Step 2 Connect the other end of t he Ethern et cable in to your managem ent network .
The Link LED on t he SCE 1 000 mana gem en t por t sh ould lig ht u p.
Step 3 Test connectivity. From the host t hat you inte nd to use for re mote ma nageme nt, ping to th e SCE 1000
by typing ping and the SCE 1000 IP address, and pre ssing Ent er (see th e example, bel ow). This verifies that an active connection exists between the specified station and the management port.
EXAMPLE:
The following example d ispl ays a typ ic al ping r esponse wher e the ta rget IP ad dre ss is 10 .1.1 .201 .
C:\>ping 10.1.1.201 pinging 10.1.1.201 ... PING 10.1.1.201: 56 data bytes 64 bytes from host (10.1.1.201): icmp_seq=0. time=0. ms 64 bytes from host (10.1.1.201): icmp_seq=1. time=0. ms 64 bytes from host (10.1.1.201): icmp_seq=2. time=0. ms 64 bytes from host (10.1.1.201): icmp_seq=3. time=0. ms
----10.1.1.201 PING Statistics---­4 packets transmitted, 4 packets received, 0% packet loss round-trip (ms) min/avg/max = 0/0/0
L
I
N
K
R
X
C
is
co
S
C
E
2
0
0
0
Series
4
xG
B
E
T
X
R
X
M
M
T
X
L
I
N
K
R
X
T
X
R
XM
M
T
X
L
I
N
K
R
X
T
X
R
X
M
M
T
X
L
I
N
K
R
X
T
X
R
X
M
M
T
X
G
B
E
-
1
S
U
B
L
I
N
E
N
E
T
P
W
R
B
S
T
AT
U
S
P
W
R
A
B
Y
P
A
S
S
10
/10
0
/
10
00
L
IN
K
/ A
C
T
IV
E
10
/1
0
0
/
1
0
0
0
L
IN
K
/ A
C
T
IV
E
G
B
E
-
2
S
U
B
L
I
N
E
/
C
A
S
C
A
D
E
N
E
T
A
U
X
C
O
N
S
O
L
E
M
N
G
2
M
N
G
1
92791
3
21
Page 46
4-26
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 4 Connect the Management Interfaces and Perform Initial System Co nfiguration
Connect the Management In terface
Page 47
CHAPTER
5-1
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
5
Cable the Line Ports
This module provid es inst ru ctions fo r ca bling t he G igab i t Eth er ne t por ts a nd fo r configuri ng G iga bit Ethernet (GBE) int erface para meter s.
Note When installing an External Optical Bypass module, the SCE 1000 line ports are connected to the
module. See Appendix A in the Cisco SCE 1000 2xGBE Installation and Configuration Guid e for complete instructions.
Information A bout Cabl ing, p age 5-1
Cabling the Line Interfaces, page 5-3
Information About Cabling
Single Link: Inline Topology, page 5-1
Single Link: Receive-only Topology, page 5-2
Single Link: Inline Topology
In the inline or bump-in-the-wire topolo gy, illustrated in the diagram bellow, the SCE 1000 resides physically on the data link between the subscriber side, usually either a BRAS (in DSL access), a PDSN (in wireless access), a CMTS (in the Cable access), or a switch or router aggregator (in other topologies), and the network side, usually a router or layer 3 switch network element. This is the inline topology, providing both traffic monitoring and control capabilities.
In this topology, all the traffic of the SCE 100 0 is de ployed a s a tr an spare nt l aye r2 overlay on the customer’s existing network.
Page 48
5-2
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter5 Cable the Line Ports
Information About Cabling
Figure 5-1 Bump-in-the-Wire Installation
Single Link: Receive-only Topology
In this topology, an external optical sp litt er re sides phys ic ally on the GB E link betw een the su bscrib er side and the network side. The external splitter is connected to the SCE 1000 via Rx links only.
In this topology, the traffic passes through the e xternal spl itter, which splits traf f ic to the SCE 1000. The SCE 1000, therefore, is in receive-only topology, having only traffic monitoring capabilities.
Note Receive-only topologies can also be implemented using a switch. Such a sw itch must supp ort SPAN
functionality that includes separation between ingress and egress traffic and multiple SPAN-ports destinations.
Cisco SCE 1000
Series
2xGBE
LINKRXTX
RX MM
TX
LINK
RX
TX
RX
MM
TX
GBE-1
SUB LINE
NET
PWR B
STATUS
PWR A
BYPASS
Router/SwitchRouter/Switch
Subscriber
92964
Network
NetworkSubscriber
Page 49
5-3
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 5 Cable the Line Ports
Cabling the Line Interfaces
Figure 5-2 External Splitting Topology
Cabling the Line Interfaces
Configure GigabitEtherne t Auto-Negot iatio n, page 5-3
Connect the GBE Line Interface Ports, page 5-4
Configure GigabitEthernet Auto-Negotiation
By default, the SCE 1000 GBE line interface ports are configured with auto-negotiation disabled.
Note If you change any parameters, you must save the new configuration settings. Type copy
running-config startup-config , and press Ent er.
Step 1 At the SCE 1000# prom pt, typ e configure and press press Enter.
Enters Global C onfigurat ion Mode .
Step 2 At the SCE 1000(config)# promp t, type interface GigabitEthernet 0/
portnumber
, and press press
Enter. Enters the GigabitEthernet Interface configuration mode for the specified GBE port.
portnumber is the numbe r of the selec ted port (1 or 2).
Step 3 At the SCE 1000(c onfig if)# pr om pt, type auto-negotiate and press pre ss Enter.
Enables auto-negotiation for the GBE interface.
Step 4 At the SCE 1000(c onfig if)# pr om pt, type exit and press press Enter.
Cisco SCE 1000
Series
2xGBE
LINKRXTX
RX MM
TX
LINKRXTX
RX
MM
TX
GBE-1
SUB LINE
NET
PWR B
STATUS
PWR A
BYPASS
Router
Optical
splitter
Router
Subscriber
210417
Network
Page 50
5-4
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter5 Cable the Line Ports
Cabling the Line Interface s
Returns to Global Configurati on Mode, fro m which you can en ter the Gigab itEt hernet Int erface configuration mode for the remaining GBE port.
Repeat this procedure to configure auto-negot iation for the othe r GBE po rt interfa ce.
Connect the GBE Line Interface Ports
Refer to Information About Cabling, page 5- 1 to find the appropriate cabling diagram for th e topology of your system.
Figure 5-3 Cabling the GBE Interface
The following table presen ts the fiber spec ificatio ns. The SCE 1000 ma y be orde red with either Multimode or Si ngle Mode tran sceivers The tr an sceiver type is i nd ica ted on the fro nt p anel u nder the ports. Note that both transceivers on any individual SCE 1000 are the same, either 850nm Multimode OR 1310 Single Mod e.
Step 1 Plug the specified fiber optic cable (see table above) into the appropriate GBE port on the front panel of
the SCE 1000.
Step 2 Verify that the link LED is green.
C
isco S
C
E
1000
Series
2xG
B
E
L
I
N
K
R
X
T
X
R
XM
MT
X
L
I
N
K
R
X
T
X
R
X
M
M
T
X
G
B
E
-
1
S
U
B
L
I
N
EN
E
T
P
W
R
B
S
T
A
T
U
S
P
W
R
A
B
Y
P
A
S
S
1
0
/
1
0
0
/
1
0
0
0
L
I
N
K
/
A
C
T
I
V
E
1
0
/
1
0
0
/
1
0
0
0
L
IN
K
/
A
C
T
I
V
E
A
U
X
C
O
N
S
O
L
E
M
N
G
2
M
N
G
1
92962
Table 5-1 Fiber Specifications
SCE Model Transceiver Transmit Power Receive Power
Typical (Max.) Distance
SCE 1000 2xGBE MM850nm Multimode –9.5 to –4 dBm –17 to 0 dBm
750m for
50µm Core Diameter MMF
400m for
62.5µm Core Diameter MMF
SCE 1000 2xGBE SM1310nm FRP laser
Single Mode
–9.5 to –3 dBm –20 to 3 dBm 10 km for 9.0µm
Core Diameter SMF
Page 51
5-5
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 5 Cable the Line Ports
Cabling the Line Interfaces
If the link LED does not light, try removing the network cable plug and reinserting it firmly into the module socket.
Page 52
5-6
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter5 Cable the Line Ports
Cabling the Line Interface s
Page 53
CHAPTER
6-1
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
6
Completing the Installation
This module discu sses how to verif y l ink conn ec tivity and how to in stall a Ser vice C ontr ol a ppli cati on .
Examining the LE Ds , pa ge 6-1
Final Tests, page 6-1
Viewing Configuration , pag e 6-2
Saving the Configuration Settings, page 6-3
Examining the LEDs
The GBE Link LED must be green to verify that an active connection exists. The GBE Rx and Tx LEDs (if flashing g reen) i ndicate t hat traffic is being r ecei v ed o r transm itted b y the
SCE 1000 platform, respectively. Note that in an inline topology, the Rx and Tx LEDs indicate that packets are being received/tr ansmitted
by the SCE 1000 platform. In optical splitter topologies, the Rx LEDs are the sole indicators. The Tx LEDs do not “blink”, since
the Tx is not connected to the port in this topology.
Final Tests
The procedures for perf ormi ng the final tests to verify that the SCE 1000 i s functioni ng proper ly are explained in the following sections.
Veri fyin g Ope rat iona l Sta tus, page 6-1
Viewing the User Lo g Count ers, pa ge 6-2
Verifying Operational Status
After all the ports are connected, verify that the SCE 1000 is not in a Warning state. To verify that the SCE 1 000 is n ot in a wa rning st at e, c om plete th e foll owing st eps:
Step 1 On the SCE 1000 Front panel, examine t hat the Statu s LED is flashi ng green .
Page 54
6-2
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 6 Completing the Installation
Viewing Configuration
Step 1 To display the operation status of the system, at the SCE 1000# prompt, type show system
operation-status
and press press Enter.
A message displaying the operation status of the system appears. If the system is operating in order, the following message appears:
System Operation status is Operational.
Example:
The following example displays a sample output where the LEDs appear red/orange:
SCE 1000numbershow system operation-status System Operation status is Operational
Viewing the User Log Counters
View the user log for errors that occu rred du ring the installati on process. To display the user log device counters, complete the following steps:
Step 1 At the SCE 1000# pr ompt, type show logger device User-File-Log counters and press press Enter.
EXAMPLE:
The following example shows the current User-File-Log device counters.
SCE 1000numbershow logger device user-file-log counters Logger device User-File-Log counters: Total info messages: 1 Total warning messages: 0 Total error messages: 0 Total fatal messages: 0
If there are “Total error messages” or “Total fatal messages”, us e th e show logger device User-Fil e- Lo g command to display details about the errors.
Viewing Configuration
When you enter configuration co mman ds, it imme diatel y effects the SCE plat form opera tion an d configuration. This configuration, referred to as the
running-config , is saved in the SCE p latf orm
volatile memory an d is effective while the SCE platform i s up. After r eb oot, the SCE platform loads the
startup-config , which inc ludes the non- default con figuration as saved by the user, into the running-config.
The SCE platform provides commands for:
Viewing the running con figurat ion
Viewing the startup configuration
Page 55
6-3
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 6 Completing the Installation
Saving the Configuration Settings
After configuring th e SC E plat fo rm, you m ay qu er y for the ru nn ing co nfigurati on usin g the co mmand
show running-config. This command displays the non-default running configuration. To view all SCE
platform running configuration, whether it is the default or not, you may use the option
all-data in the
show
running-config command.
To view the running configur ation , use the following co mman d:
Step 1 At the SCE 1000# p rompt , t yp e show run ning- config.
The system shows the running configuratio n.
SCE 1000numbershow running-config #This is a general configuration file (running-config). #Created on 15:50:56 CET MON December 11 2005 #cli-type 1 #version 1 clock timezone CET 1 snmp-server community “public” ro snmp-server host 10.1.1.253 traps version 1 “public” interface LineCard 0 connection-mode active no silent no shutdown flow-aging default-timeout UDP 60 interface FastEthernet 0/0 ip address 10.1.5.109 255.255.0.0 interface FastEthernet 0/1 interface FastEthernet 0/2 exit line vty 0 4 no timeout exit SCE 1000number
Saving the Configuration Settings
When you make change s to t he c urre nt r unn ing co nfigurati on a nd you want t ho se c ha nges t o c onti nu e to be valid when the system restarts, you must save the changes before leaving the management session, that is, you must save the running configuration to the startup configuration file.
The SCE platform provides mul tiple in terfaces for the purpose of co nfiguration a nd manage ment. Al l interfaces supply an API to the same database of the SCE platform and any configuration made through one interface is reflected through a ll interfaces. Furthermore, when saving the running configuration to the startup co nf igu ration fro m an y ma na geme nt in terf ace, al l conf ig urat ion s ettin gs ar e sa v e d re g ardl ess of the management interface used to set the configuration.
To save configuration changes, complete the following steps :
Step 1 At the SCE 1000# prom pt, typ e show running-config to view the running configuration.
The running configu ratio n is di spla yed.
Step 2 Check the displayed configuration to make sure that it is set the way you want. If no t, m ak e t he chan g es
you want before saving.
Step 3 Type copy running-config startup-config.
The system saves all running configuration information to the configuration file, which is used when the system reboots.
Page 56
6-4
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 6 Completing the Installation
Saving the Configuration Settings
The configuration file holds all information that is different from the system default in a file called config.txt located in the directory: tffs0:system.
Examples
EXAMPLE 1:
The following example sh ows the runn i ng co nfigur ation file.
SCE 1000numbershow running-config #This is a general configuration file (running-config). #Created on 15:50:56 CET MON February 11 2006 #cli-type 1 #version 1 clock timezone CET 1 snmp-server community “public” ro snmp-server host 10.1.1.253 traps version 1 “public” interface LineCard 0 connection-mode active no silent no shutdown flow-aging default-timeout UDP 60 interface FastEthernet 0/0 ip address 10.1.5.109 255.255.0.0 interface FastEthernet 0/1 interface FastEthernet 0/2 exit line vty 0 4 no timeout exit SCE 1000# SCE 1000#copy running-config startup-config Writing general configuration file to temporary location... Backing-up general configuration file... Copy temporary file to final location... SCE 1000number
For backup purposes, the old startup -config file is saved under the directory : tffs0:syst em/ prevconf. To remove a configuration co mm and f rom t he run ni ng- config, use th e no form of the command.
EXAMPLE 2:
The following example illustrates how to remove all DNS settings from the running configuration.
SCE 1000(config)#no ip name-server SCE 1000(config)#
Page 57
CHAPTER
7-1
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
7
Installing a Service Control Application
Advanced Configuration of the SCE Platform, page 7 -1
Loading and Activating a Service Control Application, page 7-1
Advanced Configuration of the SCE Plat form
After you have installed your SCE 1000 platform hardware, checked all external connections, turned on the system power, allowed the system to boot up, and performed the initial system configuration, you are ready to install the Se rvic e C ontr ol ap plic at ion. However, before you install the app lica tio n, y ou mi ght need to perform m ore co mpl ex con figurat ions, whi ch ar e beyond the scop e of thi s publi cati on .
For further information on system and interface configuration, refer to the following documents:
Cisco Service Control Engine (SC E) So ftw are Configuration Guide
Cisco Service Control Engine (SCE) CLI Co mma nd Reference
Loading and Activating a Service Con trol Applicat ion
The SCE 1000 platform provides the basic functionalities of Service Control analysis and enforcement. A Service Control solution requires that a Service Control application be loaded into the platform, to take advantage of the unique SCE platform capabilities.
Loading and activating an application includes the following stages:
Downloading the application provided as an SLI file to the SCE 1000 disk.
Activating the application.
Configuring the application.
The detailed procedure of how to perform these operations is not specified and described in this manual. For further details, refer to the following documentation:
Service Control Application f or Broadband User Gu ide
Service Control Application f or Broadband R eference Gui de
Page 58
7-2
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 7 Installing a Service Control Application
Loading and Activating a Service Control Application
Page 59
CHAPTER
8-1
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
8
Troubleshoot Startup Problems
SCE 1000 Operationa l Sta tus, page 8-1
Identifying Startup Pro blem s, page 8-3
CLI Commands for Troubleshooting , page 8-3
SCE 1000 Operational Status
The following table lists the operational states of the SCE 1000 . The Status LED on the SCE 1000 Front Panel reflects the current SCE 1000 operational status. The operational status can be displayed using CLI command show sy stem o perat ion-status .
Table 8-1 SCE 1000 Operational States
SCE 1000 Operational Status Description Status LED State
Booting Initial state after reset Orange Operational SCE 1000 becomes operational
after completing the following process:
Boot is completed
Power self-tests are
completed without failure
Platform configuration is
applied
Flashing green
Page 60
8-2
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter8 Troubleshoot Startup Problems
SCE 1000 Operational Status
W arning SCE 1000 is fully operational (as
above) but one of the fol lowing occurred:
Line ports (GBE p orts) t o
the link are down
Management port link is
down
Temperature raised above
threshold
Voltage not in req uired
range
Fans problem
Power supply problem
Insufficient space on the
disk
Note If the condition that
caused the SCE 1000 to be in Warning state is resolved (for exampl e, link is up) the SCE 1000 reverts to Operational state.
Flashing orange
Failure System is in Failure state after
Boot due to one of the following conditions:
Power on test failure
Three abnormal reboot s in
less than 20 minut es
Platform conf igured to enter
Failure mode conseque nt t o failure-induced reboot (this is configurable using CLI command)
Note Depending on the caus e
of failure, the management interfa ce and the platf orm configuration may or may not be active/available.
Red
Table 8-1 SCE 1000 Operational States (continued)
SCE 1000 Operational Status Description Status LED State
Page 61
8-3
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 8 Troubleshoot Startu p Problems
Identifying Startup Problems
Identifying Startup Problems
Startup problems a re co mmo nly due to the so urce p ower or to a po or c able con ne ction . This section conta ins a detai led desc ripti on of th e nor mal start up seque nce and descr ibe s the s teps to
take if the system does not perform that sequence as expected. LEDs indicate all system states in the startup sequence. By checking the state of the LEDs, you can determine when and where the system failed in the startup sequence. Use the following descriptions to isolate the problem to a subsystem, and then proceed to the appropriate sections to try to resolve the problem.
When you start up the system by turning on the power supply switch, the following should occur:
You shou ld i mme diat el y h ear the fan s o pera tin g.
When all LEDs come on to indicate that the system has booted successfully, the initial system
banner should be displayed on the console scree n. If it is not disp layed, see Co nnec t th e Loca l
Console, page 4-1 to verify that the terminal is set correctly and that it is properly connected to the
console port.
If the banner is displayed, but the Status LED is flashi ng orange, indicating a warning state, check
the user log: At the prompt, type:
more user log
If any of the following warning messages appear, turn the SCE 1000 platform off and call technical
support.
"voltage problem"
"fans problem"
"abnormal raise in interior temperature"
If the following warning me ssage app ea rs, d elet e unn ee ded files from the disk.
“insufficient disk space:”
CLI Commands for Troubleshooting
Use the following com ma nd s to provi de i nfo rmat ion to he lp y ou trou bl es hoot inst alla tio n o f your SC E 1000 platform. Refer to Cisco Service Control Engine (SCE) Software Configuration Guide or the Cisco Service Control Engine (SCE) CLI Command Reference for m ore i n forma tio n.
Note Remember that if the management interface is not operational, you should connect the SCE 1000
platform to a loc al conso le so th at you can e nter C LI comm a nds for t roubl esho ot ing.
Troubleshooting firmware package installation:
boot system <filename>— Specifies and verifies the package file to be installed. Error messages or other output identify problems with the package file.
Following is a sample output from the boot systemcommand.
SCE 1000(config)#boot system ftp://vk:vk@10.1.1.230/downloads/SENum.pkg.pkg Verifying package file SENum.pkg.pkg… Package file verified OK.
Troubleshooting the management subsystem:
Page 62
8-4
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter8 Troubleshoot Startup Problems
CLI Commands for Trouble shooting
show interface Mng — Displays IP address and auto-negotiation information for the management inter faces. Following i s a sa mp le outpu t fr om the s how interfa ce Mng c om mand.
Following isa sample outp ut f rom t he show interface Mng command.
ip address: 10.1.6.145 subnet mask: 255.255.0.0 Configured speed: auto, configured duplex: auto AutoNegotiation is On, link is Up, actual speed: 100, actual duplex: half
show ip default-gateway — Displays the IP address of the configured default gateway.
Following is a sample output from the show ip default-gateway command.
Default gateway: 10.1.1.1
show ip route — Displays the entire routing table and the destination of last resort (default-gateway).
Following is a sample output from the show ip route command.
gateway of last resort is 10.1.1.1
show access-lists — Shows all access-lists or a specific access list.
Following is a sample output from the show access-lists command.
Standard IP access list 1 Permit 10.1.1.0, wildcard bits 0.0.0.255 deny any
show telnet — Displays the status of the telnet server daemon ( status) or any active Telnet sessions ( sessions).
Following is a sample output from the show telnet command.
show telnet sessions There is 1 active telnet session: Index | Source ================ 0 | 10.1.1.201 show telnet status Telnet deamon is enabled.
show line vty timeout — Shows the timeout configured for Telnet sessions.
Following is a sample output from the show line vty timeout command.
Timeout is 30 minutes
Troubleshooting the link interface subsystem:
show interface GigabitEthernet 0/# — Displa ys informa tion for a specific GBE Inte rface.
Following is a sample output from the show interface command.
ip address: 10.1.6.145 subnet mask: 255.255.0.0 Configured duplex: auto AutoNegotiation is On, link is Up, actual duplex: half
show interface GigabitEthernet 0/# counters — Displays the values of counters of a GBE interface.
Following is a sample output from the show interfacecount erscommand.
In total octets: 191520 In good unicast packets: 560 In good multicast packets: 0 In good broadcast packets: 0 In packets discarded: 0 In packets with CRC/Alignment error: 0 In undersized packets: 0 In oversized packets: 0 Out total octets: 0
Page 63
8-5
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 8 Troubleshoot Startu p Problems
CLI Commands for Troubleshooting
Out unicast packets: 0 Out non unicast packets: 0 Out packets discarded: 0
Refer to The U se r Lo g f or an expla nat ion of co mm an ds re lat ed t o the us er log .
Page 64
8-6
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter8 Troubleshoot Startup Problems
CLI Commands for Trouble shooting
Loading...