1. Before You Begin ................................................................................................................ 4
What is Included .................................................................................................................................................. 4
Text Conventions ................................................................................................................................................. 4
Product at a Glance ............................................................................................................................................. 5
AC Power ............................................................................................................................................................. 8
Power Linking ...................................................................................................................................................... 9
Power Linking Diagram................................................................................................................................... 9
Control Panel Description .................................................................................................................................. 11
Menu Map ..................................................................................................................................................... 11
Auto Mode .................................................................................................................................................... 19
Pan Reverse ................................................................................................................................................. 20
Reset to Factory Defaults ............................................................................................................................. 21
System Information ............................................................................................................................................ 21
IR Mode ........................................................................................................................................................ 22
Configuring the Slaves.................................................................................................................................. 23
Configuring the Master ................................................................................................................................. 23
5. Technical Information ....................................................................................................... 24
Intimidator Scan/Barrel 305 IRC User Manual Rev. 1 Page 2 of 27
Contact Us ............................................................................................................................. 27
Intimidator Scan/Barrel 305 IRC User Manual Rev. 1 Page 3 of 27
1. B
EFORE YOU BEGIN
What is
•
• Power Cord
Unpacking
Instructions
Carefully unpack the product immediately and check that all th e parts are in the pac kage and
Claims
If the box or any of the contents appear dam aged fr om shipping, or s how signs of mishandling,
or failure to have all packaging available for
missing components or parts, damage not related to shipping, or
For information on
Text
Convention
Meaning
1–512
A range of values
50/60
A set of values
Settings
A menu option
Menu > Settings
A sequence of menu options
<ENTER>
A button to be pressed
ON
A value to be entered or selected
Symbols
Symbol
Meaning
Critical installation, configuration, or operation information. Not following
Disclaimer
The information and specif ications cont ained in this User Manual are subject to change without
Author
Date
Editor
Date
M. Trouard
11/03/15
M. Gregory
11/03/15
Intimidator Scan 305 IRC
Included
Conventions
or
•
Intimidator Barrel 305 IRC
are in good condition.
save all packaging an d file a claim with the carrier immediately, do not notify Chauvet. Failure
to report damage to the carrier immediately
inspection may invalidate your claim.
For other issues, such as
concealed damage, file a claim with Chauvet within 7 days of delivery.
contacting Chauvet, see the Contact Us section of this manual.
• Warranty Card
• Quick Reference Guide
these instructions can make the product not work, cause damage to the
product, or cause harm to the operator.
Important installation or configuration information. The product might
not function correctly if this information is not used.
Useful information.
notice. Chauvet assumes no responsib ility or liabil ity for any errors or om issions, and res erves
the right to revise or recreat e this m anual at an y time. T he latest vers ion of th is manual s hould
be downloaded from http://www.chauvetlighting.com/product-manuals-literature/.
Electronically published by Chauvet in the United States of America.
Intimidator Scan/Barrel 305 IRC User Manual Rev. 1 Page 4 of 27
Product at a
Use on Dimmer
x
Auto Programs
P
Outdoor Use
x
Auto-ranging Power Supply
P
Sound-Activated
P
Replaceable Fuse
P
DMX
P
User-Serviceable
x
Master/Slave
P
Safety Notes
These notes include important information abou t the mounting, use, and m aintenance of this
• Always connect the product to a grounded circuit to avoid the risk of electrocution.
• This product is not intended for permanent installation.
Glance
product. Read these notes before using the product.
• Make sure the power cord is not crimped or damaged.
• Always disconnect the product from the power source before cleaning it or replacing the
fuse.
• Never disconnect the product from the power source by pulling or tugging on the cord.
• If mounting the product overhead, always secure it using a safety cable.
• Make sure there are no flammable materials close to the product when it is operating.
• Avoid direct eye exposure to the light source while the product is on.
• Do not touch the product’s housing when the product is operating becaus e the housing can
be very hot.
• The product is for indoor use only! It is rated at IP20.
• To prevent risk of fire or shock, do not expose the product to rain or moisture.
• Always make sure that the voltage of the power source to which the product is connected
is within the range stated on the sticker or rear panel of the product.
• Never connect the product to a dimmer or rheostat.
• Make sure to replace the fuse with another of the same type and rating.
• Always install the product in a location with adequate ven tilat ion, and leave at least 20 in
(50 cm) between the product and adjacent surfaces.
• Always use the handles to carry this product.
• The maximum ambient temperature (Ta) in which the product can be used is
104 °F (40 °C). Do not operate the product at higher temperatures.
• Be sure that no ventilat ion s lots on the produc t’s housing are blocked.
• Never carry the product by the power cord or any moving part.
• In the event of a serious operating problem, stop using the product immediately.
• Never try to repair the product. Repairs carried out by unskilled people can lead to damage
or malfunction. Contact the nearest authorized technical assistance center.
•To eliminate wear and improve its lifespan, during periods of non-use completely
disconnect from power via breaker or by unplugging it.
Keep this User Manual for future reference. If you sell the product to another user, be sure to
give this manual to the next owner.
Intimidator Scan/Barrel 305 IRC User Manual Rev. 1 Page 5 of 27
2. I
NTRODUCTION
Overview
Pass-Through
Adjustable
Lens
Front View (Barrel)
Safety Cable
DMX In/Out
Power In
Back Panel View
Mirror
Display
IR Sensor
LED Indicator
Menu Buttons
Fuse Holder
Power Out
Front View (Scan)
Intimidator Scan/Barrel 305 IRC User Manual Rev. 1 Page 6 of 27
Dimensions
18.9 in
480 mm
6.7 in
171 mm
10 in
255 mm
10 in
255 mm
16.9 in
430 mm
5.7 in
147 mm
Barrel
Scan
Intimidator Scan/Barrel 305 IRC User Manual Rev. 1 Page 7 of 27
3. S
ETUP
AC Power
The Intimidator Scan/Barrel 305 IR C have auto-ranging power s u ppl ies that work with an i nput
circuit breaker, power outle t, and wiri ng), us e
’s average current draw under
•Always connect the product to a protected circuit (circuit breaker or fuse). Make
rheostat (variable resistor) or dimmer, even if the
use completely
disconnect from power via breaker or by unplugging it.
Fuse
Make sure product is not connected to a power source.
•Disconnect the product from power before replacing the fuse.
voltage range of 100 to 240 VAC, 50/60 Hz.
To determine the product’s power requirements (
the values listed on the label affixed to the product’s back panel, or refer to the product’s
Specifications. The listed current rating indicates the product
normal conditions.
The Intimidator Scan/Bar rel 305 IRC can be power li nked via the I EC and Edis on outlets in its
base.
sure circuit has an appropriate electrical ground to avoid the risk of electrocution or
fire.
•Never connect the product to a
rheostat or dimmer serves only as a 0 to 100% switch.
•To eliminate wear and improve its lifespan, during periods of non-
Replacement
1. Place the tip of a flat-head screwdriver into the slot in the fuse holder.
2. Turn the screwdriver counterclockwise and the fuse holder will come loose.
3. Pull the fuse holder out of the product.
4. Pull the blown fuse out of the fuse holder.
5. Place a new fuse of the exact same type and rating into the fuse holder.
6. Insert the fuse holder into the product.
7. Place the tip of a flat-head screwdriver into the slot in the fuse holder.
8. Turn the screwdriver clockwise and the fuse holder will tighten into place.
•Use only the fuse listed in the Technical Specifications section or on the
specifications sticker on the product.
•A spare fuse is not included.
Intimidator Scan/Barrel 305 IRC User Manual Rev. 1 Page 8 of 27
Power Linking
The product provides power linking via the Edison/IEC outlet located in the back of the unit.
Power Linking
or up to
•The power linking diagram shown above corresponds to the North American version
country to country, and region to region.
1st
2nd
3rd
Additional Products
Diagram
Up to 5 Intimidator Scan/Barrel 305 IRC units can be linked on 120 V,
12 Intimidator Scan/Barrel 305 IRC units on 230 V.
Product
Product
Product
of the product ONLY!
•If using this product anywhere other than North America, consult with the local
Chauvet distributor because power linking connectors and requirements differ from
Intimidator Scan/Barrel 305 IRC User Manual Rev. 1 Page 9 of 27
Mounting
Before mounting the product, read and follow the safety recomm endations in the Safety Not es
section.
Orientation
The Intimidator Scan/Barrel 305 IRC can be mounted in any position, but make sure the
Rigging
Be sure to place the product in a location that allows easy access to it for maintenanc e and
the
and make sure the product is
appropriate
See
on the floor, mak e sure that
Hanging/
Mounting
Bracket
through on
placement allows adequate venti lation for the product, and a llows for movem ent of the yoke
and head in any direction.
programming, and enough space around the product for ventilation.
Make sure that the s tr ucture or surface onto which the product will be mounted can suppor t
product’s weight. For more information see the Technical Specifications section.
When mounting the product overh ead, al ways use a s afet y cable
attached securely.
When mounting the product on a truss or pipe, use a mounting clamp with the
weight capacity. Chauvet has a full range of mounting clamps.
http://www.chauvetlighting.com/cables-clamps-main.html for the complete selection.
The rubber feet serve as floor s upports. When placing the product
the product and cables are away from people and vehicles.
Mounting Clamps
(such as CLP-15 from Chauvet)
Rigging Diagram
Rubber Feet (x4)
Safety Cable
(such as CH-05 from
Chauvet)
Secure the safety cable
using the pass-
the back of the product
Intimidator Scan/Barrel 305 IRC User Manual Rev. 1 Page 10 of 27
4. O
Control Panel
The control panel is used to set the operating mode, and the configuration sett ings of the
display to access the control panel and
Button
Function
<MENU>
Enters into, or backs out of, the current menu option
<UP>
Scrolls up the list of options or selects a higher valu e
<DOWN>
Scrolls down the list of options or selects a lower value
<ENTER>
Activates a selected menu or value
Menu Map
The Menu Map presents all the options in the menu system, and the values to set them.
Menu
Value
Description
Address
001–512
Sets the DMX starting address
7CH
11CH
Slave
Slave1–4
Sets Slave mode
Auto
Sets Auto mode
Sound
Sets Sound mode
IR
Sets infrared control
Pan
0 to 180°
Tilt
0 to 90°
P/T Speed
Pan/Tilt speed (fast to slow)
Color
Selects color options
Dimmer
Sets dimmer value
Shutter
Strobe effect with increasing speed
Gobo
Selects Gobo options
Gobo
Rotation effect with increasing
Prism
Selects 3-facet prism
Special
P/T Macro
Selects pan/tilt movement macros
PERATION
Description
product. Use the 4 buttons underneath the LCD
navigate the menu map. For specific instructions see the Configurations sections below.
DMX
Sets DMX personality
Run Mode
Manual
Rotate
Function
Intimidator Scan/Barrel 305 IRC User Manual Rev. 1 Page 11 of 27
000–255
speed
Selects control functions
Menu
Value
Description
Pan Reverse
OFF
Normal pan operation
ON
Reverse pan operation
OFF
Normal tilt operation
ON
Reverse tilt operation
OFF
Normal display
ON
Upside-down display
Sensitivity
001—100
Sets sound sensitivity
Reset
Resets the product
Factory Set
Loads factory defaults
Ver: VX.X
Temperature: XXX
Tilt Reverse
Sys Info
Setup
Screen
Reverse
Running Mode: XXXX
DMX Address: XXX
Shows the current software version,
running mode, DMX address and
product’s temperature
Intimidator Scan/Barrel 305 IRC User Manual Rev. 1 Page 12 of 27
Configuration
To set the product in DMX mode for control with a DMX controller, do the following:
DMX Starting
When selecting a starting DMX address, always consider the number of DMX channels
channels, depending on the
DMX Personalities
The Intimidator Scan/Barrel 305 IRC has 2 DMX personalities: a 7-channel pers onality and
<ENTER>
After the DMX starting address and person ality hav e been set, there will be a delay of
to showing the current DMX
(DMX)
Address
1. Make sure the product is plugged into a power source.
2. Connect the male end of a DMX cable to the DMX out socket of the DMX controller and
the female end of the same cable to the DMX in socket on the product.
3. Set the DMX starting address and personality by following the directions below.
needed for the selec ted DMX personality. Choosing a starting ad dress that is too high can
restrict access to some of the product’s channels.
The Intimidator Scan/Barrel 305 IRC uses either 7 or 11
personality. The h ighest configurable DMX address in 7-chan nel mode is 506. T he highest
configurable DMX address in 11-channel mode is 502.
For more information abo ut DMX downl oad the Chauvet DMX Prim er f r om t he Chauvet web
site http://www.chauvetlighting.com/download.
To set the DMX starting address, do the following:
1. If the display shows a number from 001–512, go to step 5.
2. Press <MENU> repeatedly until 4 icons show on the display.
3. Use <UP> or <DOWN> t o hig hlight Address.
4. Press <ENTER> and a number from 001–512 will show on the display.
5. Use <UP> or <DOWN> to change the number to the desired DMX starting address.
6. Press <ENTER> to select the DMX starting address.
an 11-channel personality.
To set the DMX personality, do the following:
1. Press <MENU> repeatedly until 4 icons show on the display.
2. Use <UP> or <DOWN> to highlight the Run Mode icon.
3. Press <ENTER> and the Run Mode options will show on the display.
4. Use <UP> or <DOWN> t o hig hlight DMX.
5. Press <ENTER>. A green dot will show on the DMX option line and the characters 7CH
or 11CH will show in green.
6. Use <UP> or <DOWN> to switch between 7CH and 11CH.
7. Press
to select the DMX personality shown.
30 seconds before the display automatically returns
address and the DMX personality.
Intimidator Scan/Barrel 305 IRC User Manual Rev. 1 Page 13 of 27
DMX Channel
Assignments and
Values
The following table outl ines all the capabilities of the Intimidator Scan/ Barrel 305 IRC and
11-CH
Channel
Function
Value
Percent/Setting
1
Pan
000 ó 255
0–180°
Tilt (Scan)
000 ó 255
0–90°
000 ó 019
Stop
020 ó 135
Clockwise rotation (slow to fast)
136 ó 139
Stop
140 ó 255
Counter-clockwise rotation (slow to fast)
3
Pan/Tilt Speed
000 ó 255
Fast to slow
000 ó 006
Open (white)
007 ó 013
Yellow
014 ó 020
Purple
021 ó 027
Green
028 ó 034
Red
035 ó 041
Light Blue
042 ó 048
Kelly Green
049 ó 055
Orange
056 ó 063
Dark Blue
064 ó 070
White + Yellow (split colors)
071 ó 077
Yellow + Purple (split colors)
078 ó 084
Purple + Green (split colors)
085 ó 091
Green + Red (split colors)
092 ó 098
Red + Blue (split colors)
099 ó 105
Light Blue + Kelly Green (split colors)
106 ó 112
Kelly Green + Orange (split colors)
113 ó 119
Orange + Dark Blue (split colors)
120 ó 127
Dark Blue + White (split colors)
128 ó 191
Rotate counter-clockwise (slow to fast)
192 ó 255
Rotate clockwise (slow to fast)
000 ó 003
Closed
004 ó 007
Open
008 ó 076
Synchronized Strobe (slow to fast)
077 ó 145
Pulse Strobe (slow to fast)
146 ó 215
Random Strobe (slow to fast)
216 ó 255
Open
the channels that control them when the light is used with a lighting controller.
2
Tilt (Barrel)
4 Color
5 Shutter
Intimidator Scan/Barrel 305 IRC User Manual Rev. 1 Page 14 of 27
11-CH
Channel
Function
Value
Percent/Setting
6
Dimmer
000 ó 255
0 to 100%
000 ó 007
Open
008 ó 015
Gobo 1 (glass)
016 ó 023
Gobo 2 (glass)
024 ó 031
Gobo 3
032 ó 039
Gobo 4
040 ó 047
Gobo 5
048 ó 055
Gobo 6
056 ó 063
Gobo 7
064 ó 071
Gobo 7 shake, fast to slow
072 ó 079
Gobo 6 shake, fast to slow
080 ó 087
Gobo 5 shake, fast to slow
088 ó 095
Gobo 4 shake, fast to slow
096 ó 103
Gobo 3 shake, fast to slow
104 ó 111
Gobo 2 (glass) shake, fast to slow
112 ó 119
Gobo 1 (glass) shake, fast to slow
120 ó 127
Open
128 ó 191
Gobo scroll: counter-clockwise rotation
192 ó 255
Gobo scroll: clockwise rotation
000 ó 063
Gobo indexing counter-clockwise
064 ó 147
Rotate (slow to fast)
148 ó 231
Rotate opposite (slow to fast)
232 ó 255
Gobo bounce
000 ó 007
Prism
008 ó 255
Stop, static prism effect
7 Gobo Wheel
8 Gobo Rotation
9 Prism
Intimidator Scan/Barrel 305 IRC User Manual Rev. 1 Page 15 of 27
11-CH
Channel
Function
Value
Percent/Setting
10 Operating Mode
000 ó 007
No function
008 ó 015
Pan/tilt move-in-black
016 ó 023
Pan/tilt move-in-black (disable)
024 ó 031
Color wheel move-in-black
032 ó 039
Gobo wheel move-in-black (disable)
040 ó 047
Gobo wheel move-in-black
Color wheel and Gobo wheel move-in-black
056 ó 063
Fast movement
064 ó 087
Fast movement (disable)
088 ó 095
All movement move-in-black (disable)
096 ó 103
Reset pan/tilt
104 ó 111
No function
112 ó 119
Reset color wheel
120 ó 127
Reset gobo wheel
128 ó 135
No function
136 ó 143
Reset prism
144 ó 151
No function
152 ó 159
Reset all
160 ó 255
No function
000 ó 007
No function
008 ó 023
Automatic 1
024 ó 039
Automatic 2
040 ó 055
Automatic 3
056 ó 071
Automatic 4
072 ó 087
Automatic 5
088 ó 103
Automatic 6
104 ó 119
Automatic 7
120 ó 135
Automatic 8
136 ó 151
Sound 1
152 ó 167
Sound 2
168 ó 183
Sound 3
184 ó 199
Sound 4
200 ó 215
Sound 5
216 ó 231
Sound 6
232 ó 247
Sound 7
248 ó 255
Sound 8
048 ó 055
(disable)
11
Intimidator Scan/Barrel 305 IRC User Manual Rev. 1 Page 16 of 27
Movement
Macros
7CH
Channel
Function
Value
Percent/Setting
1
Pan
000 ó 255
0 to 180°
Tilt (Scan)
000 ó 255
0 to 90°
000 ó 019
Stop
020 ó 135
Clockwise rotation (slow to fast)
136 ó 139
Stop
140 ó 255
Counter-clockwise rotation (slow to fast)
000 ó 006
Open (white)
007 ó 013
Yellow
014 ó 020
Purple
021 ó 027
Green
028 ó 034
Red
035 ó 041
Light Blue
042 ó 048
Kelly Green
049 ó 055
Orange
056 ó 063
Dark Blue
064 ó 070
White + Yellow (split colors)
071 ó 077
Yellow + Purple (split colors)
078 ó 084
Purple + Green (split colors)
085 ó 091
Green + Red (split colors)
092 ó 098
Red + Blue (split colors)
099 ó 105
Light Blue + Kelly Green (split colors)
106 ó 112
Kelly Green + Orange (split colors)
113 ó 119
Orange + Dark Blue (split colors)
120 ó 127
Dark Blue + White (split colors)
128 ó 191
Rotate counter-clockwise (slow to fast)
192 ó 127
Rotate clockwise (slow to fast)
000 ó 003
Closed
004 ó 007
Open
008 ó 076
Synchronized Strobe (slow to fast)
077 ó 145
Pulse Strobe (slow to fast)
146 ó 215
Random Strobe (slow to fast)
216 ó 255
Open
2
Tilt (Barrel)
3 Color
Intimidator Scan/Barrel 305 IRC User Manual Rev. 1 Page 17 of 27
4 Shutter
7CH
Channel
Function
Value
Percent/Setting
5 Gobo Wheel
000 ó 007
Open
008 ó 015
Gobo 1 (glass)
016 ó 023
Gobo 2 (glass)
024 ó 031
Gobo 3
032 ó 039
Gobo 4
040 ó 047
Gobo 5
048 ó 055
Gobo 6
056 ó 063
Gobo 7
064 ó 071
Gobo 7 shake, fast to slow
072 ó 079
Gobo 6 shake, fast to slow
080 ó 087
Gobo 5 shake, fast to slow
088 ó 095
Gobo 4 shake, fast to slow
096 ó 103
Gobo 3 shake, fast to slow
104 ó 111
Gobo 2 (glass) shake, fast to slow
112 ó 119
Gobo 1 (glass) shake, fast to slow
120 ó 127
Open
128 ó 191
Gobo scroll: counter-clockwise rotation
192 ó 255
Gobo scroll: clockwise rotation
000 ó 063
Gobo indexing
064 ó 147
Rotate (slow to fast)
148 ó 231
Rotate opposite (slow to fast)
232 ó 255
Gobo bounce
000 ó 007
Prism
008 ó 255
Stop, static prism effect
6 Gobo Rotation
7 Prism
Intimidator Scan/Barrel 305 IRC User Manual Rev. 1 Page 18 of 27
Configuration
(Standalone)
Use standalone configurations to operate the product without a DMX controller.
Never connect a product operating in a standalone mode (Sound, Auto, or IR) to a
transmit
Sound Mode
Sound mode sets the product to respond to sounds and music.
and not connected to a DMX
option line and the product will
The product will respond only to low frequencies of music (bass and drums).
For more
Auto Mode
Auto mode sets the product to 1 of 16 preset movement patterns and color changes.
and not connected to a DMX
option line and the product will
Manual Mode
Manual mode allows the user to control every function of the Intimidator Scan/Barr el 305
IRC through the LCD display. To run the product in Manu al mode, follow the instructions
a power sourc e and not connected to a DMX
,
) of the selected function will be
DMX chain that includes a DMX controller. Products in standalone mode can
DMX signals that interfere with the DMX signal s from the controller
To set the product to Sound mode, do the following:
1. Make sure the product is connected to a power source
controller.
2. Press <MENU> repeatedly until 4 icons show on the display.
3. Use <UP> or <DOWN> to highlight the Run Mode icon.
4. Press <ENTER> and the Run Mode options will show on the display.
5. Use <UP> or <DOWN> to highlight the Sound option.
6. Press <ENTER>. A gr een dot will show on the Sound
begin reacting to sound.
If the product is not responding to sound, increase the sensitivity.
information see the Sensitivity Setting below.
To set the product to Auto mode, do the following:
1. Make sure the product is connected to a power source
controller.
2. Press <MENU> repeatedly until 4 icons show on the display.
3. Use <UP> or <DOWN> to highlight the Run Mode icon.
4. Press <ENTER> and the Run Mode options will show on the display.
5. Use <UP> or <DOWN> to highlight the Auto option.
6. Press <ENTER>. A green dot will show on the Auto
begin moving and emitting light.
below:
1. Make sure the produc t is connected to
controller.
2. Press <MENU> repeatedly until 4 icons show on the display.
3. Use <UP> or <DOWN> to highlight the Run Mode icon.
4. Press <ENTER> and the Run Mode options will show on the display.
5. Use <UP> or <DOWN> to highlight the Manual option.
6. Press <ENTER> and the Manual options will sho w on the displ a y.
7. Use <UP> or <DOWN> to select Pan, Tilt, P/T Sp eed , Color, Dimmer, Shutter, Gobo
Gobo Rotate, Prism, Special Function, or P/T Macro.
8. Press <ENTER> and the current value (000–255
9. Use <UP> or <DOWN> to increase or decrease the value of the selected function.
10. Press <ENTER>.
11. Repeat steps 7–10 until the product is set as desired.
highlighted.
Intimidator Scan/Barrel 305 IRC User Manual Rev. 1 Page 19 of 27
Configuration
(Settings)
The Intimidator Scan/Barrel 305 IRC can be customized with settings such as pan direction,
all the settings
Pan Reverse
Reversing the pan m ovement is us eful when 2 lights are fac ing each oth er and t hey both n eed to
<ENTER>
Tilt Reverse
Reversing the tilt m ovement is usef ul when 2 lig hts are facing eac h other and t hey need to poi nt
4 icons show on
<ENTER>
Screen Reverse
The display can show t he screen in two directions , one for when the fixture is standing and one
7. Press <ENTER> to select the setting.
screen orientation, and sound sensitivity. Below are instructions for configuring
available.
turn toward the same direction.
To reverse the pan movement do the following:
1. Press <MENU> repeatedly until 4 icons show on the display.
2. Use <UP> or <DOWN> to highlight the Setup icon.
3. Press <ENTER>. The Setup options wil l show on the displa y.
4. Use <UP> or <DOWN> to highlight the Pan Reverse option.
5. Press <ENTER>. The words ON or OFF will show in green.
6. Use <UP> or <DOWN> to switch between ON and OFF.
7. Press
towards the same space between them.
To reverse the tilt movem ent, do the following: Press <MENU> repeatedl y until
the display.
1. Use <UP> or <DOWN> to highlight the Setup icon.
2. Press <ENTER>. The Setup options wil l show on the displa y.
3. Use <UP> or <DOWN> to highlight the Tilt Reverse option.
4. Press <ENTER>. The words ON or OFF will show in green.
5. Use <UP> or <DOWN> to switch between ON and OFF.
6. Press
to select the setting.
to select the setting.
for when it is mounted upside-down.
To set the display orientation, do the following:
1. Press <MENU> repeatedly until 4 icons show on the display.
2. Use <UP> or <DOWN> to highlight the Setup icon.
3. Press <ENTER>. The Setup options will show on the display.
4. Use <UP> or <DOWN> to highlight the Screen Reverse option.
5. Press <ENTER>. The words ON or OFF will show in green.
6. Use <UP> or <DOWN> to switch between ON (upside-down display) and
OFF (normal display).
Intimidator Scan/Barrel 305 IRC User Manual Rev. 1 Page 20 of 27
Reset
Resetting will restart the product. It does not change any settings. Resetting is a helpful
troubleshooting too l, and can be used if the product has stopped responding to control, or if the
<ENTER>
Reset to Factory
Resetting to factory def aults will clear out al l customized settings an d return thee settings to the
Resetting to factory defaults can be used if the product is behaving
System
To see the product’s current sof tware version, ru nning mode, DMX address and temperature, do
<ENTER>
control system has suffered a failure.
To reset the product, do the following:
1. Press <MENU> repeatedly until 4 icons show on the display.
2. Use <UP> or <DOWN> to highlight the Setup icon.
3. Press <ENTER>. The Setup options will show on the display.
4. Use <UP> or <DOWN> to highlight the Reset option.
5. Press
. The product will immediately reset.
Defaults
Information
factory defaults.
inconsistently.
To reset the product to factory default settings, do the following:
1. Press <MENU> repeatedly until 4 icons show on the display.
2. Use <UP> or <DOWN> to highlight the Setup icon.
3. Press <ENTER>. The Setup options wil l show on the displa y.
4. Use <UP> or <DOWN> to highlight the Factory Set option.
5. Press <ENTER>. The product will immediately reset to factory default settings.
the following:
1. Press <MENU> repeatedly until 4 icons show on the display.
2. Use <UP> or <DOWN> to highlight the Sys Info icon.
3. Press
. The current information about the product will show on the display.
Intimidator Scan/Barrel 305 IRC User Manual Rev. 1 Page 21 of 27
IR Mode
IR mode allows the product to be controlled with a n infrared remote controller. The IRC-6
can remotely set the produc t to
various modes; adjust the color , speed and sensitivit y; and
option line and the product will begi n
IRC-6 Operation
The IRC-6 infrared controller (available from Chauvet) allows remote control of the
Be sure the IRC-6 remote is pointing directly at the product and there is nothing in
Some of the buttons on the remote work differently than what is indicated on their
Please read the next section carefully.
The list below describes which features each button controls.
set the strobe.
To set the product to IR mode, do the following:
Make sure the product is plugged into a power source and not connected to a DMX cable.
1. Press <MENU> repeatedly until 4 icons show on the display.
2. Use <UP> or <DOWN> to highlight the Run Mode icon.
3. Press <ENTER>. The Run Mode options will show on the displ a y.
4. Use <UP> or <DOWN> to highlight the IR option.
5. Press <ENTER>. A green dot will s how on the IR
moving and emitting light.
Intimidator Scan/Barrel 305 IRC.
between the remote and the product.
labels. For example:
• <MANUAL> controls the gobo selection.
• <R>, <G>, <B>, <A>, <UV>, and <W> control the other manual functions.
• <BLACKOUT> - Turns LEDs on and off.
• <AUTO> - Activates Auto mode. Use the <+> and <-> buttons to cycle through Auto
modes.
• <SOUND> - Activates Sound mode.
• <STROBE> - Activates the strobe. Use the <+> and <-> buttons to cycle through strobe
speeds.
•<SPEED> - Adjusts the movement speed. Use the <+> and <-> buttons to cycle through
movement speeds.
•<SENSITIVITY> - Adjusts sound sensitivity. Use the <+> and <-> buttons to cycle
through sound sensitivity levels.
•<%> - Adjusts the brightness of the LEDs. Use the <+> and <-> buttons to increase or
decrease the brightness of the LEDs.
• <MANUAL> - Cycle through static gobos.
• <FADE/SNAP> or <FADE> - Cycle through static colors.
• <R> - Sets the color wheel rotation speed. Use the <+> and <-> buttons to increase or
decrease the color wheel rotation speed.
•<G> - Sets the gobo wheel rotation speed. Use the <+> and <-> buttons to increase or
decrease the gobo wheel rotation speed.
• <B> - Sets CG. AUTO mode. Colors and gobos will cycle automatically.
• <A> - Sets R/T PAN/TILT. Press <A> to toggle PAN and TILT. Use the <+> and <->
buttons to increase or decrease the selected value.
•<W> - Sets the prism value. Use the <+> and <-> buttons to increase or decrease the
prism value.
• <+> - Increases values for controls as described above.
• <-> - Decreases values for controls as described above.
• <0>–<9> - Activates specific Auto modes. Can be used as a shortcut for the
combination of the <AUTO> button and the <+> and <-> buttons.
•<UV> or <P> - Has no function with this product.
Intimidator Scan/Barrel 305 IRC User Manual Rev. 1 Page 22 of 27
Configuration
Master/Slave mode allows a single Intimidator Scan/Barrel 305 IRC (the master) to control
a DMX
or IR
The master and slaves ar e dais y chained tho ugh the DMX input and o utput port s with th e
s will operate
•Always put the male DMX connector into the master. Do not connect to the
Configuring the
Configure the slaves f or Slave mode before or after they are put in position, and before
Configuring the
Configure the master after all the slaves are connected to it and configured.
the
(Master/Slave)
Slaves
the actions of one or more Intimidator Scan/Barrel 305 IRCs (the slaves) without
controller.
In Master/Slave mode the master is set to operate in Auto mode, Sound mode,
mode and the slaves are set to operate in Slave mode.
master at the beginning of the chain. Once set and connected, the slave
identically to, and in unison with, the master.
DMX In port on the master.
• Never connect more than 31 slaves to the master.
• Never connect a DMX controller to a DMX daisy chain of master and slaves.
• Configure all the slaves before connecting the master to the DMX daisy chain.
they are daisy chained to the master.
To configure a slave, do the following:
1. Make sure the product is connected to a power source.
2. Press <MENU> repeatedly until 4 icons show on the display.
3. Use <UP> or <DOWN> to highlight the Run Mode icon.
4. Press <ENTER>. The Run Mode options will show on the display.
5. Use <UP> or <DOWN> to highlight the Slave option.
6. Press <ENTER>. The current Slave mode will be highlighted.
7. Use <UP> or <DOWN> to select the Slave mode.
• Select Slave1 for 100% synchronized actions.
• Select Slave2, Slave3, or Slave4 for a delayed show, creating a wave effect.
Master
To configure the master, do the following:
1. Make sure the product is connected to a power source and connected to all of
slaves.
2. Press <MENU> repeatedly until 4 icons show on the display.
3. Use <UP> or <DOWN> to highlight the Run Mode icon.
4. Select any of the Standalone modes as described in Configuration (Standalone).
Intimidator Scan/Barrel 305 IRC User Manual Rev. 1 Page 23 of 27
5. T
ECHNICAL INFORMATION
Product
Dust build-up on the lens reduces light output. Dust build-up on the body and fans can
the
If the environment is particularly dusty, clean the product
surfaces carefully after cleaning
Maintenance
cause overheating and mechanical wear, which can reduce the usable life of the product.
To maintain optimum performance and minimal wear in a normal environment, clean
product at least twice a month.
more often.
For best results follow the suggestions listed below:
1. Never clean the product when it is plugged into a power source.
2. Only clean the product when it is at room temperature.
3. Use a vacuum (or dry compressed air) and a soft brush to remove dust collected on the
external surfaces and in the vents.
4. Use a mild soap solution, ammonia-free glass cleaner, or isopropyl alcohol to clean all
the external optics and glass or transparent surfaces.
5. Apply the cleaning solution directly to a soft, lint-free cotton cloth or a lens cleaning
tissue.
6. Gently wipe dirt and grime to the outside edges of the external optics and glass or
transparent surfaces.
7. Gently polish the external optics and glass or transparent surfaces until they are free of
haze and lint.
Always dry the external o pt ics and glass/transparent
them.
Do not spin the cooling fans while blowing compressed air into them.
Intimidator Scan/Barrel 305 IRC User Manual Rev. 1 Page 24 of 27
6. T
Dimensions and
Length (Scan)
Width (Scan)
Height (Scan)
Weight (Scan)
16.9 in (430 mm)
10 in (255 mm)
5.7 in (147 mm)
10 lb (4.6 kg)
Length (Barrel)
Width (Barrel)
Height (Barrel)
Weight (Barrel)
18.9 in (480 mm)
10 in (255 mm)
6.7 in (171 mm)
10.4 lb (4.8 kg)
Note: Dimensions in inches are rounded to the nearest decimal digit
Power
Power Supply Type
Range
Voltage Selection
Switching (internal)
100 to 240 VAC, 50/60 Hz
Auto-ranging
Parameter
120 V, 60 Hz
230 V, 50 Hz
Consumption
104 W
102 W
Operating current
1.5 A
0.8 A
Fuse
F 3 A, 250 V
F 3 A, 250 V
Power I/O
US/Canada
UK/Worldwide
Power input connector
IEC
IEC
Power output connector
Edison (US)
N/A
Power cord plug
Edison (US)
Local plug
Power linking current (units)
13.6 A (5 units)
13.6 A (10 units)
Light Source
Type
Power
Lifespan
LED
60 W
50,000 hours
Color
Quantity
Current
White
1
2.3 A
Photo Optic
Parameter
Scan
Barrel
Illuminance @ 2 m
9,110 lux
1,630 lux (per beam)
Beam angle
15°
12°
Strobe rate
0–35 Hz
0–35 Hz
Pan
180°
180°
Tilt
90°
360° (continuous)
Thermal
Maximum External Temp.
Cooling System
104 °F (40 °C)
Fan-cooled
DMX
I/O Connectors
Connector Type
Channel Range
3-pin XLR
Sockets
7 or 11
Ordering
Product Name
Item Code
UPC Number
Intimidator Scan 305 IRC
08021029
781462213770
Intimidator Barrel 305 IRC
08021047
781462213954
ECHNICAL SPECIFICATIONS
Weight
Intimidator Scan/Barrel 305 IRC User Manual Rev. 1 Page 25 of 27
R
ETURNS
In case you need to get support or return a product:
If you are located outside the U.S., UK, Ireland, Mexico, or Benelux, contact your
products to
them. Visit our website
for contact details.
Call the corresponding Chauvet Technical Support office and request a Return Merchandise
Authorization (RMA) number before shipping the product. Be prepared to provide the model
rchandise prepaid, in its ori ginal box , and with its origina l pack ing an d acces sories .
Clearly label the package with the RMA number. Chauvet will refuse any product returned
on a properly affixed label. DO NOT write the RMA number
Before sending the produc t , clearly write the following information on a piece of paper and place
properly. Any shipping damage resulting from inadequate
reserves the right to use its own discretion to repair or replace returned
• If you are located in the U.S., contact Chauvet World Headquarters.
• If you are located in the UK or Ireland, contact Chauvet Europe Ltd.
• If you are located in Mexico, contact Chauvet Mexico.
• If you are located in Benelux, contact Chauvet Europe BVBA.
• If you are located in any other country, DO NOT contact Chauvet. Instead, contact your local
distributor. See www.chauvetlighting.com for distributors outside the U.S., UK, Ireland,
Mexico, or Benelux.
distributor of record and follow their instructions on how to return Chauvet
www.chauvetlighting.com
number, serial number, and a brief description of the cause for the return.
Send the me
Chauvet will not issue call tags.
without an RMA number.
Write the RMA number
directly on the box.
it inside the box:
• Your name
• Your address
• Your phone number
• RMA number
• A brief description of the problem
Be sure to pack the product
packaging will be your responsibility. FedEx packing or double-boxing are recommended.
Chauvet
product(s).
Intimidator Scan/Barrel 305 IRC User Manual Rev. 1 Page 26 of 27
C
USA WORLD HEADQUARTERS
General Information
Technical Support
Wor l d Wide Web www.chauvetlighting.com
EUROPE.
General Information
Voice: +32 9 388 93 97
Technical Support
General Information
Fax: +44 (0)1773 511110
Technical Support
MEXICO
General Information
Voice: +52 (728) 285-5000
Technical Support
contact your dealer. Follow their ins tructions to
request support or to return a product. Visit our website for contact details.