Carefully unpack the product immediately and check the container to make sure all the parts are in the
package and are in good condition.
Claims
If the box or the contents (the product and included accessories) appear damaged from shipping, or show
signs of mishandling, notify the carrier immediately, not Chauvet. Failure to report damage to the carrier
immediately may invalidate the claim. Keep the box and contents for inspection.
For other issues, such as missing components or parts, damage not related to shipping, or concealed
damage, file a claim with Chauvet within 7 days of delivery.
Text Conventions
ConventionMeaning
1–512A range of values
50/60A set of values of which only one can be chosen
SettingsA menu option not to be modified
<ENTER>A key to be pressed on the product’s control panel
ONA value to be entered or selected
•Omega bracket
•Quick Reference Guide
Symbols
SymbolMeaning
Electrical warning. Not following these instructions may cause electrical damage to
the product, accessories, or the user.
Critical installation, configuration, or operation information. Not following these
instructions may make the product not work, cause damage to the product, or cause
harm to the operator.
Important installation or configuration information. The product may not function
correctly if this information is not used.
Useful information.
1
Intimidator Free Spot 60 ILS User Manual Rev. 2
Before You Begin
Safety Notes
■ALWAYS:
•Connect to a grounded circuit.
•Connect to operating voltages as specified on the product's spec sticker.
•Disconnect from power before replacing the fuse.
•Disconnect from its power source during periods of inactivity.
•Use a safety cable when suspending overhead.
•Heed all restrictions and warnings on the spec sticker.
•Mount in a location with at least 20 in (50 cm) of ventilation.
•Replace the fuse with the same type and rating.
■In the event of a serious operating problem, stop using immediately.
■DO NOT:
•Open this product or attempt any repairs. It contains no user-serviceable parts.
•Look at the light source when the product is on.
•Use if the power cord is crimped or damaged.
•Disconnect by pulling on the power cord.
•Allow flammable materials close to the product when it is operating.
•Touch the housing when it is on.
•Block any ventilation holes/slots in the housing.
•Connect to a dimmer or rheostat.
•Carry the product by its power cord.
•Operate in temperatures higher than 104°F (40°C).
•Expose to environments that exceed the Ingress Protection (IP) rating.
•Expose to rain or moisture.
•Use outdoors.
•Submerge.
•Expose to corrosive environmental conditions such as temperature, humidity, salinity,
pressure, radiation, or shock.
•Set this product on a flammable surface.
Battery Charge Notes
Rechargeable lithium-ion batteries are potentially hazardous and can present a serious FIRE HAZARD,
SERIOUS INJURY and/or PROPERTY DAMAGE if damaged, defective, or improperly used.
■ALWAYS:
♦Charge using a manufacturer-provided charger while the product is powered off.
♦Charge the battery in temperatures between 32°–95°F (0°–35°C).
♦Allow a depleted battery to charge for a few minutes before turning on the product. If the
battery is completely discharged, the device cannot be turned on immediately when the
charger is connected.
♦Keep at least 3 ft (1 m) distance to any heat source and away from flammable materials.
♦Keep the lid of any charging case open while charging.
♦Keep batteries away from children.
♦Store batteries between 40–60% charge.
♦Follow local regulations when disposing of batteries.
♦Replace with an authentic Chauvet battery.
■DO NOT:
♦Continue charging if the battery becomes hot, smokes, swells, or gives off an odor during
charging.
♦Leave the product unattended while charging.
♦Deplete the battery below 10%.
♦Charge the battery in a closed container.
♦Charge for more than 24 hours.
Intimidator Free Spot 60 ILS User Manual Rev. 2
2
Before You Begin
FCC Statement of Compliance
This device complies with Part 15 Part B of the FCC rules. Operation is subject to the following two
conditions:
1.This device may not cause harmful interference, and
2.This device must accept any interference received, including interference that may cause
undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
•Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the party responsible for compliance could void
the user's authority to operate the equipment.
RF Exposure Warning for North America and Australia
Warning! This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with a minimum distance of 20 cm between
the radiator and the user. This transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter.
Disclaimer
Chauvet believes that the information contained in this manual is accurate in all respects. However,
Chauvet assumes no responsibility and specifically disclaims any and all liability to any party for any loss,
damage or disruption caused by any errors or omissions in this document, whether such errors or
omissions result from negligence, accident or any other cause. Chauvet reserves the right to revise the
content of this document without any obligation to notify any person or company of such revision, however,
Chauvet has no obligation to make, and does not commit to make, any such revisions. Download the latest
version from www.chauvetdj.com
The works of authorship contained in this manual, including, but not limited to, all designs, text, and images
are owned by Chauvet.
Electronically published by Chauvet in the United States of America.
Chauvet, the Chauvet logo, and Intimidator Free Spot 60 ILS are registered trademarks or trademarks of
Chauvet & Sons LLC. (d/b/a Chauvet and Chauvet Lighting) in the United States and other countries. Other
company and product names and logos referred to herein may be trademarks of their respective companies.
Keep this User Manual for future use.
.
3
Intimidator Free Spot 60 ILS User Manual Rev. 2
Introduction
Menu buttons
USB slot
DMX in/out
Fuse
holder
Display screen
Power in
Carry handle
Safety loop
2. Introduction
Product Overview
Intimidator Free Spot 60 ILS User Manual Rev. 2
4
Product Dimensions
10.2 in
258 mm
15.4 in
391 mm
11.9 in
301 mm
11.4 in
290 mm
Introduction
5
Intimidator Free Spot 60 ILS User Manual Rev. 2
Setup
!
Safety cap
Spare fuse holder
(inside safety cap)
Installed fuse
(held by plastic clip)
!
100
In use
Charging
3. Setup
AC Power
The Intimidator Free Spot 60 ILS has an auto-ranging power supply, and it can work with an input voltage
range of 100 to 240 VAC, 50/60 Hz.
To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the current value
listed on the label affixed to the product’s back panel or refer to the product’s specifications chart. The listed
current rating indicates the product’s average current draw under normal conditions.
•Always connect the product to a protected circuit (a circuit breaker or fuse). Make
sure the product has an appropriate electrical ground to avoid the risk of
electrocution or fire.
•To eliminate unnecessary wear and improve its lifespan, completely disconnect the
product from power via breaker or by unplugging it during periods of non-use.
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if
the rheostat or dimmer channel serves only as a 0 to 100% switch.
Fuse Replacement
1. Disconnect the product from power.
2. Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
3. Pry the fuse holder out of the housing.
4. Remove the blown fuse from the holder and replace with a fuse of the exact same type and rating.
5. Insert the fuse holder back in place and reconnect power.
•Disconnect the product from the power outlet before replacing the fuse.
•Always replace a blown fuse with one of the same type and rating.
Battery Power
The
Intimidator Free Spot 60 ILS
Charging the Battery
The battery charges whenever the Intimidator Free Spot 60 ILS is plugged into a power source using the
included power cable. If the product is plugged in and not in operation, make sure the product is turned off.
•Before charging the product, read and follow the safety recommendations in the
Safety Notes
•The LED indicator light will flash if units are overcharged.
•DO NOT use the Intimidator Free Spot 60 ILS on full power mode while being
charged/plugged into a power source, as the unit will get extremely hot.
Battery Life Indicator
The numbers displayed on the battery indicator show how much battery life remains available. The battery
indicator will display up to four (+) signs while charging.
Battery Run Time
comes with a rechargeable lithium battery for cable-free operation.
.
Maximum Run Time Recharge Time
Up to 8 hours6.75 hours
Intimidator Free Spot 60 ILS User Manual Rev. 2
6
Setup
Safety cable
(such as CH-05 from Chauvet)
Mounting clamp
(such as CLP-15 or CLP-15N
from Chauvet)
Omega bracket
Mounting
Before mounting the product, read and follow the safety recommendations indicated in the Safety Notes.
Orientation
The Intimidator Free Spot 60 ILS may be mounted in any position; however, make sure adequate
ventilation is provided around the product.
Rigging
•Before deciding on a location for the product, always make sure there is easy access to the product
for maintenance and programming purposes.
•Make sure adequate ventilation is provided around the product.
•Mount the product on a structure or surface that can support the product's weight (see the Te ch ni c al
Specifications for weight information).
•Always use a safety cable when mounting the product overhead. Mount the product securely to a
rigging point (e.g., an elevated platform or a truss).
•Use a mounting clamp of appropriate weight capacity when rigging the product onto a truss.
Mounting Diagram
7
Intimidator Free Spot 60 ILS User Manual Rev. 2
Operation
4. Operation
Control Panel Operation
To access the control panel functions, use the four buttons located next to the display. Please refer to the
Introduction
ButtonFunction
<MENU> Exits from the current menu or function
<UP>Navigates upwards through the menu list and increases the numeric value when in a function
<DOWN>
<ENTER>
Menu Map
Refer to the Intimidator Free Spot 60 ILS product page on www.chauvetdj.com for the latest menu map.
Main MenuProgramming LevelsDescription
DMX Address001–499Selects DMX starting address
Run Mode
to see the button locations on the control panel.
Navigates downwards through the menu list and decreases the numeric value when in a function
Enables the currently displayed menu or sets the currently selected value into the selected function
08CH8-channel DMX mode
Setup
DMX
SlaveSlave 1–4
ILSILS1–4Sets ILS mode
AUTOSets the fixture to Auto mode
SoundSets the fixture to Sound mode
RFSets the fixture to connect via RF
Manual
DFI
D-Fi Channel1–16Sets D-Fi channel
Pan Reverse
Tilt Reverse
Screen Reverse
Pan Angle
Tilt Angle
Tote m M o de
Sensitivity000–100Sets the sound sensitivity in Sound mode
10CH10-channel DMX mode
14Ch14-channel DMX mode
Sets which slave unit(s) will mimic the master
unit
Pan
Tilt
ColorSelects the color manually
GoboSelects the gobo manually
Gobo
Rototate
PrismAdjusts prism
FocusAdjusts focus
DimmerAdjusts the brightness
ShutterAdjusts the shutter
000–255
RXSets the product to receive D-Fi signal
TXSets the product to transmit D-Fi signal
OFFDisables D-Fi mode
OFFNormal pan operation
ONReverse pan operation
OFFNormal tilt operation
ONReverse tilt operation
OFFNormal display
ONReverse display
540Selects the 540° pan angle range
360Selects the 360° pan angle range
180Selects the 180° pan angle range
234Selects the 234° tilt angle range
180Selects the 180° tilt angle range
90Selects the 90° tilt angle range
OFFDoes not restrict the pan and tilt motion
UP
DOWN
Adjusts the pan angle
Adjusts the tilt angle
Adjusts gobo rotation
Restricts the pan and tilt motion for overhead
mounting
Restricts the pan and tilt motion for surface/
floor mounting
Intimidator Free Spot 60 ILS User Manual Rev. 2
8
Main MenuProgramming LevelsDescription
HoldHolds the last setting when DMX signal is lost
BlackBlacks out the fixture when DMX signal is lost
Sets the fixture to Auto mode when DMX
signal is lost
Sets the fixture to Sound mode when DMX
signal is lost
The LED indicator flashes when the unit is
connected to the DMX
The LED indicator flashes when the unit is
disconnected from the DMX
Adjusts the light and power consumption
based on the amount of time the fixture has
been running
Enables control of the fixture using any RF
remote
Enables control of the
Intimidator Free Spot 60 ILS using only the RF
remote paired to the fixture
Sets which group of fixture the RF remote will
control
Link the fixture to a single remote and displays
the ID of the linked remote.
Press <ENTER> then hold and press
<BLACKOUT>.
The display will show “SUCCESS” (success)
or “ERROR” (failure).
Enables fixture to be controlled via ILS command
Resets individual functions or all functions
from startup
Resets settings to factory default
Displays the DMX address
Setup
Sys Info
DMX Loss
Indicator
Flash if DMX
Runtime
RF
RF GroupGroup1–4
RF Bind_ _ _ _
Follow Spot
Reset
Factory Reset
Ver:V _ _ _Displays the firmware version
Running
Mode:
DMX Address:_ _ _
Temperature:_ _ _ °CDisplays the LED PCB temperature in °C
DFI:_ _ _Displays the D-Fi status
Auto
Sound
ONEnables LED indicator
OFFDisables LED indicator
ON
OFF
4 Hours
6 Hours
8 Hours
Common
Bind
OffDisables RF connection
OFFDisables Follow Spot mode
ON
NO
YES
NO
YES
_ _ _ Displays the current running mode
Operation
DMX Configuration
The Intimidator Free Spot 60 ILS works with a DMX controller. Information about DMX is in the Chauvet
DMX Primer available from the Chauvet website: www.chauvetdj.com.
DMX Personality and Starting Address
When selecting a starting DMX address, always consider the number of DMX channels the selected DMX mode
uses. Choosing a starting address that is too high could restrict access to some of the product’s channels.
The Intimidator Free Spot 60 ILS uses up to 14 DMX channels in a 14CH DMX mode, which defines the
highest configurable address to 499.
For more information about the DMX protocol, download the DMX Primer from: www.chauvetdj.com
To select the starting address, do the following:
1. Press <MENU> repeatedly until DMX Address shows on the display.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to select the starting address, from 001–499.
4. Press <ENTER>.
9
Intimidator Free Spot 60 ILS User Manual Rev. 2
.
Operation
12 3
45
6
7
Gobos
DMX Values
08CH 10CH 14CH FunctionValuePercent/Setting
111Pan000 255 0–540°
––2Fine pan000 255 Fine control of panning
223Tilt 000 255 0–234°
––4Fine tilt000 255 Fine control of tilting
––5Pan/tilt speed000 255 Pan/tilt speed, fast to slow
000 006 White
007 013 Red
014 020 Orange
021 027 Yellow
028 034 Green
035 041 Blue
336Color wheel
447
558Gobo rotation
Gobo wheel
(see Gobos
)
042 048 CTO
049 055 Cyan
056 062 Magenta
063 189 Color indexing
190 221 Color clockwise rotation, fast to slow
222 223 Stop
224 255 Color counter-clockwise rotation, slow to fast
000 007 Open
008 015 Gobo 1
016 023 Gobo 2
024 031 Gobo 3
032 039 Gobo 4
040 047 Gobo 5
048 055 Gobo 6
056 063 Gobo 7
064 071 Gobo 7 shake, slow to fast
072 079 Gobo 6 shake, slow to fast
080 087 Gobo 5 shake, slow to fast
088 095 Gobo 4 shake, slow to fast
096 103 Gobo 3 shake, slow to fast
104 111 Gobo 2 shake, slow to fast
112 119 Gobo 1 shake, slow to fast
120 127 Open
128 189 Gobo clockwise rotation, slow to fast
190 193 Stop
194 255 Gobo counter-clockwise rotation, slow to fast
000 007 No function
008 119 Gobo rotation, clockwise, slow to fast
120 231 Gobo rotation, counterclockwise, slow to fast
232 255 Gobo bounce, short to long
Intimidator Free Spot 60 ILS User Manual Rev. 2
10
08CH 10CH 14CH FunctionValuePercent/Setting
669Prism
7710Focus000 255 Focus, large to small
–811Dimmer000 255 0–100%
8912Shutter
–1013Function
––14Movement macro
000 015 No function
016 255 3-facet prism
000 003 Closed
004 007 Open
008 076 Strobe, slow to fast
077 145 Pulse strobe, slow to fast
146 215 Random strobe, slow to fast
216 255 Open
000 007 No function
008 015 Blackout on pan/tilt movement
016 023 Blackout on color wheel movement
024 031 Blackout on gobo wheel movement
056 095 No function
096 103 Pan reset
104 111 Tilt reset
112 119 Color wheel reset
120 127 Gobo wheel reset
128 135 No function
136 143 Prism reset
144 151 Focus reset
152 159 Reset all
160 167 No function
168
176 183 Runtime 4-hour mode
184 192 Runtime 6-hour mode
193 200 Runtime 8-hour mode
201 255 No function
000 007 No function
008 023 Movement macro 1
024 039 Movement macro 2
040 055 Movement macro 3
056 071 Movement macro 4
072 087 Movement macro 5
088 103 Movement macro 6
104 119 Movement macro 7
120 135 Movement macro 8
136 151 Sound-active macro 1
152 167 Sound-active macro 2
168 183 Sound-active macro 3
184 199 Sound-active macro 4
200 215 Sound-active macro 5
216 231 Sound-active macro 6
232 247 Sound-active macro 7
248 255 Sound-active macro 8
175 Run time from display menu setting
Operation
11
Intimidator Free Spot 60 ILS User Manual Rev. 2
Operation
Standalone Configuration
Set the product in one of the standalone modes to control without a DMX controller.
Never connect a product that is operating in any standalone mode to a DMX string
connected to a DMX controller. Products in standalone mode may transmit DMX signals
that could interfere with the DMX signals from the controller.
Run Mode
Automatic mode
To run the Intimidator Free Spot 60 ILS in automatic mode, follow the instructions below:
1. Press <MENU> repeatedly until Run Mode is displayed.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to select Auto.
4. Press <ENTER>.
Sound-active mode
To run the Intimidator Free Spot 60 ILS in sound mode, do the following:
1. Press <MENU> repeatedly until Run Mode is displayed.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to select Sound.
4. Press <ENTER>.
RF mode
To use the Intimidator Free Spot 60 ILS with an RFC or RFC-XL remote, it must first be set to RF mode. To
do this, follow the instructions below:
1. Press <MENU> repeatedly until Run Mode is displayed.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to select RF.
4. Press <ENTER>.
For more information about using the Intimidator Free Spot 60 ILS with an RF remote,
see RFC Remote Control
section.
Manual Mode
To operate the Intimidator Free Spot 60 ILS manually through the menu, do the following:
1. Press <MENU> repeatedly until Run Mode is displayed.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to select Manual.
4. Press <ENTER>.
5. Use <UP> or <DOWN> to select from Pan, Tilt, Color, Gobo, Gobo Rotate, Prism, Focus,
Dimmer, or Shutter.
6. Press <ENTER>.
7. Use <UP> or <DOWN> to increase or decrease the value of the selected function, from 000–255.
8. Press <ENTER>.
9. Repeat steps 6-9 until the product is set as desired.
Intimidator Free Spot 60 ILS User Manual Rev. 2
12
Operation
Settings Configuration
Use a DMX controller to set and control the Intimidator Free Spot 60 ILS.
D-Fi Settings
To access the D-Fi Setting menu on the Intimidator Free Spot 60 ILS, do the following:
1. Press <MENU> repeatedly until Setup shows on the display.
2. Press <ENTER>.
3.Use
4. Press <ENTER>.
To set which D-Fi mode the Intimidator Free Spot 60 ILS will follow, follow the instructions below:
1. Select the DFI option.
2. Use <UP> or <DOWN> to select RX (to set the product to receive D-Fi signal), TX (to set the
3. Press <ENTER>.
To set the D-Fi channel on the Intimidator Free Spot 60 ILS, do the following:
1. Select the DFI Channel option.
2. Use <UP> or <DOWN> to set the D-Fi channel, from 1–16.
3. Press <ENTER>.
Pan Reverse
To manually set the orientation of the pan on the Intimidator Free Spot 60 ILS, follow the instructions below:
1. Press <MENU> repeatedly until Setup shows on the display.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to select Pan Reverse.
4. Press <ENTER>.
5. Use <UP> or <DOWN> to select OFF (normal pan motion) or ON (reversed pan motion).
6. Press <ENTER>.
Tilt Reverse
To manually set the orientation of the tilt on the Intimidator Free Spot 60 ILS, do the following:
1. Press <MENU> repeatedly until Setup shows on the display.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to select Tilt Reverse.
4. Press <ENTER>.
5. Use <UP> or <DOWN> to select OFF (normal tilt motion) or ON (reversed tilt motion).
6. Press <ENTER>.
Screen Reverse
To manually set the orientation of the tilt on the Intimidator Free Spot 60 ILS, do the following:
1. Press <MENU> repeatedly until Setup shows on the display.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to select Screen Reverse.
4. Press <ENTER>.
5. Use <UP> or <DOWN> to select OFF (normal screen display) or ON (reversed screen display).
6. Press <ENTER>.
Pan Range
To set the maximum angle of the pan on the Intimidator Free Spot 60 ILS, do the following:
1. Press <MENU> repeatedly until Setup shows on the display.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to select Pan Range.
4. Press <ENTER>.
5. Use <UP> or <DOWN> to set the pan angle from 180 (180°), 360 (360°), or up to 540 (540°).
6. Press <ENTER>.
Tilt Range
To set the maximum angle of the tilt on the Intimidator Free Spot 60 ILS, follow the instructions below:
1. Press <MENU> repeatedly until Setup shows on the display.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to select Tilt Range.
4. Press <ENTER>.
5. Use <UP> or <DOWN> to set the tilt angle from 90 (90°), 180 (180°), or up to 234 (234°).
6. Press <ENTER>.
<UP>
or
<DOWN>
product to transmit D-Fi signal), or OFF (to deactivate D-Fi mode).
to select
DFI
(to activate D-Fi mode) or
DFI Channel
(to set the D-Fi channel).
13
Intimidator Free Spot 60 ILS User Manual Rev. 2
Operation
Totem Mode
To restrict the range of pan and tilt motion based on how the Intimidator Free Spot 60 ILS is mounted, do
the following:
1. Press <MENU> repeatedly until Setup is displayed.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to select Totem Mode.
4. Press <ENTER>.
5. Use <UP> or <DOWN> to select from OFF (no restriction on the pan and tilt motion), UP (restricts
the pan and tilt motion for overhead mounting), or DOWN (restricts the pan and tilt motion for
surface or floor mounting).
6. Press <ENTER>.
Sound Sensitivity
To set the sound sensitivity on the Intimidator Free Spot 60 ILS, follow the instructions below:
1. Press <MENU> repeatedly until Setup is displayed.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to select Sensitivity.
4. Press <ENTER>.
5. Use <UP> or <DOWN> to increase or decrease the sound sensitivity, from 000–100.
6. Press <ENTER>.
DMX Loss
To set the action that the Intimidator Free Spot 60 ILS will do when the DMX signal is lost, do the following:
1. Press <MENU> repeatedly until Setup is displayed.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to select DMX Loss.
4. Press <ENTER>.
5. Use <UP> or <DOWN> to select from Hold (holds the last setting when DMX signal is lost), Black
(blacks out the fixture when DMX signal is lost), Auto (sets the fixture to Auto mode when DMX
signal is lost), or Sound (sets the fixture to Sound mode when DMX signal is lost).
6. Press <ENTER>.
Indicator
To enable or disable the LED indicator on the Intimidator Free Spot 60 ILS, follow the instructions below:
1. Press <MENU> repeatedly until Setup is displayed.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to select Indicator.
4. Press <ENTER>.
5. Use <UP> or <DOWN> to select from ON (enables the LED indicator) or OFF (disables the LED
indicator).
6. Press <ENTER>.
Flash if DMX
To set whether the LED indicator flashes when the Intimidator Free Spot 60 ILS is connected to or
disconnected from the DMX, do the following:
1. Press <MENU> repeatedly until Setup is displayed.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to select Flash if DMX.
4. Press <ENTER>.
5. Use
6. Press <ENTER>.
Run Time
To adjust the run time on the Intimidator Free Spot 60 ILS, follow the instructions below:
1. Press <MENU> repeatedly until Setup is displayed.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to select Runtime.
4. Press <ENTER>.
5.Use
6.Press
<UP>
or
the DMX) or
<UP>
<ENTER>
The maximum output is inversely proportional to the run time: The brighter the output, the
less run time available.
<DOWN>
OFF
or
<DOWN>
to select from ON (the LED indicator flashes when the fixture is connected to
(the LED indicator flashes when the fixture is disconnected to the DMX).
to select the number of hours the fixture will run:
.
4 Hours, 6 Hours
, or
8 Hours
.
Intimidator Free Spot 60 ILS User Manual Rev. 2
14
Operation
RF Setting
To set how the Intimidator Free Spot 60 ILS will receive RF signal and work with RF remotes, do the following:
1. Press <MENU> repeatedly until Setup is displayed.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to select RF.
4. Press <ENTER>.
5. Use <UP> or <DOWN> to select from the following: Common (to allow the fixture to respond to all
RF signals), Bind (to link the fixture to a single RF remote), or Off (to turn off RF reception).
6. Press <ENTER>.
RF Group
To select which group of fixtures the RF remote will control, follow the instructions below:
1. Press <MENU> repeatedly until Setup is displayed.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to select RF Group.
4. Press <ENTER>.
5. Use <UP> or <DOWN> to select Group 1–4.
6. Press <ENTER>.
Follow Spot
To enable control of the Intimidator Free Spot 60 ILS via ILS command, do the following:
1. Press <MENU> repeatedly until Setup is displayed.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to select Follow Spot.
4. Press <ENTER>.
5. Use
6. Press <ENTER>.
Product Reset
To reset individual or all functions on the Intimidator Free Spot 60 ILS upon startup, do the following:
1. Press <MENU> repeatedly until Setup is displayed.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to select Reset.
4. Press <ENTER>.
5. Use
6. Press <ENTER>.
Factory Reset
To reset the product to factory default settings, follow the instructions below:
1. Press <MENU> repeatedly until Setup is displayed.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to select Factory Reset.
4. Press <ENTER>.
5. Use
6. Press <ENTER>.
Product Information
To view the product information, do the following:
1. Press <MENU> repeatedly until Sys Info shows on the display.
2. Press <ENTER>.
3.
<UP>
or
<DOWN>
<UP>
or
<DOWN>
product reset from startup).
<UP>
or
<DOWN>
Use
<UP>
or
<DOWN>
•Ver: displays the current software version of the fixture
•Running Mode: displays the current running mode
•DMX Address: displays the DMX address
•Temperature: displays the LED PCB temperature in °C
•DFI: displays the fixture’s D-Fi status
to select
to select
to select
to
ON
YES
YES
choose among:
(enables Follow Spot mode) or
(enables reset of all functions from startup) or
(enables factory reset) or
OFF
(disables Follow Spot mode).
NO
(disables factory reset).
NO
(disables
15
Intimidator Free Spot 60 ILS User Manual Rev. 2
Operation
ILS Mode
ILS (Integrated Lighting System) provides 4 modes that synchronize with the GigBAR MOVE+ILS: Modes
1 and 3 synchronize with side 1 of the GigBAR MOVE+ILS, whereas modes 2 and 4 synchronize with side
2 of the GigBAR MOVE+ILS. When linked, effects will sync with the most similar effect on the selected side
of the GigBAR MOVE+ILS: Kinta effects will sync with one of the kintas, moving heads will sync with one of
the moving heads, and wash effects will sync with one of the pars. Laser effects will sync with the laser,
and strobe effects will sync with the strobe effects regardless of ILS mode.
This product will synchronize with the spot effect on the selected side of the GigBAR MOVE+ILS, as well
as the laser and strobes.
To set the Intimidator Free Spot 60 ILS to respond to an ILS signal:
1. Press <MENU> repeatedly until ILS shows on the display.
2. Use <UP> or <DOWN> to select from ILS1 (side 1), ILS2 (side 2), ILS3 (side 1), or ILS4 (side 2).
3. Press <ENTER>.
Master/Slave Mode
The Master/Slave mode allows a single Intimidator Free Spot 60 ILS product (the “master”) to control the
actions of one or more Intimidator Free Spot 60 ILS products (the “slaves”) without the need of a DMX
controller. The master product will be set to operate in Standalone, whereas the slave products will be set
to operate in Slave mode. Once set and connected, the slave products will operate in unison with the
master product. Configure the products as indicated below.
Slave products:
1. Press <MENU> repeatedly until Setup shows on the display. Press <ENTER>.
2. Use <UP> or <DOWN> to select DFI. Press <ENTER>.
3. Use <UP> or <DOWN> to select RX. Press <ENTER>.
4. Press <MENU> repeatedly until Run Mode shows on the display. Press <ENTER>.
5. Use <UP> or <DOWN> to select Slave. Press <ENTER>.
6. Use <UP> or <DOWN> to select the slave unit(s), from Slave1–4. Press <ENTER>.
7. Set the DMX address to 001.
8. Set the D-Fi to receive a specific channel, 1–16.
9. Finish setting and connecting all the slave products.
Master product:
1. Set the master product to operate in standalone mode.
2. Set the D-Fi to transmit on the D-Fi channel the slaves are receiving on.
•For more information on how to activate the Intimidator Free Spot 60 ILS built-in
D-Fi, see D-Fi Settings.
•All products must be set to the same DMX personality, DMX address, and D-Fi
channel.
•Configure all the slave products before configuring the master to transmit.
•Never connect a DMX controller to a D-Fi channel configured for Master/Slave
operation because the controller may interfere with the signals from the master.
Intimidator Free Spot 60 ILS User Manual Rev. 2
16
AUTO
FADE
SOUND
SPEED /
SENSITIVITY
STROBE
DIMMER
RED
GREEN
BLUE
AMBER
WHITE
UV
PAN
TILT
COLOR
GOBO
PRISM
FOCUS
ZOOM
GOBO
ROTATE
PRISM
ROTATE
FREEZE
GROUP
Black
OUT
Operation
RFC Remote Control
The Intimidator Free Spot 60 ILS can be operated with an RFC remote or an RFC-XL remote (sold
separately). To enable RF control, follow the instructions below:
1.Press <MENU> repeatedly until Setup shows on the display.
2.Press <ENTER>.\
3.Use <UP> or <DOWN> to select RF.
4.Press <ENTER>.
5.Use <UP> or <DOWN> to select from the following: Common (to allow the fixture to respond to
all RF signals), Bind (to link the fixture to a single RF remote), or Off (to turn off RF reception).
6.Press <ENTER>.
For more information about using an RFC or RFC-XL remote, download the user
manuals from www.chauvetdj.com
RFC-XL Remote Control Operation
Automatic Mode
Automatic mode will enable you to run the automatic programs on the product.
To turn on Automatic mode:
1.Press <AUTO>.
2.Press <+> or <–> to choose between the different auto programs.
To adjust the speed of the automatic program:
1.Press <SPEED/SENSITIVITY>.
2.Press <+> or <–> to increase or decrease the speed of the program.
Sound-Active Mode
To turn on Sound-Active mode:
1.Press <SOUND>.
2.Press <+> or <–> to select a sound-active program.
To adjust the sound sensitivity:
1.Press <SPEED/SENSITIVITY>.
2.Press <+> or <–> to increase or decrease the sensitivity.
Dimmer
To adjust the total output of the product:
1.Press <DIMMER>.
2.Press <+> or <–> to increase or decrease the output level.
Prism
To adjust the focus of the product’s output:
1.Press <PRISM>.
2.Press <+> or <–> to select the prism.
Focus
To adjust the focus of the product’s output:
1.Press <FOCUS>.
2.Press <+> or <–> to adjust the focus.
Pan
To adjust the product’s pan angle:
1.Press <PAN>.
2.Press <+> or <–> to adjust the pan.
Tilt
To adjust the product’s tilt angle:
1.Press <TILT>.
2.Press <+> or <–> to adjust the tilt.
Black Out
To black out the lights of the product:
1.Press <Black OUT>. This will turn off all the lights until the button is
pressed again.
The RFC-XL remote will not respond to any inputs when Black Out is
activated. If the remote does not respond when a button is pressed, try
pressing <BLACK OUT>. You may have inadvertently activated Black Out.
17
Intimidator Free Spot 60 ILS User Manual Rev. 2
Maintenance
5. Maintenance
Product Maintenance
Dust build-up reduces light output performance and can cause overheating. This can lead to reduction of
the light source’s life and/or mechanical wear. To maintain optimum performance and minimize wear, clean
all lighting products at least twice a month. However, be aware that usage and environmental conditions
could be contributing factors to increase the cleaning frequency.
To clean the product, follow the instructions below:
1.Unplug the product from power.
2.Wait until the product is at room temperature.
3.Use a vacuum (or dry compressed air) and a soft brush to remove dust collected on the external
surface/vents.
4.Clean all transparent surfaces with a mild soap solution, ammonia-free glass cleaner, or isopropyl
alcohol.
5.Apply the solution directly to a soft, lint-free cotton cloth or a lens-cleaning tissue.
6.Softly drag any dirt or grime to the outside of the transparent surface.
7.Gently polish the transparent surfaces until they are free of haze and lint.
Always dry the transparent surfaces carefully after cleaning them.
Intimidator Free Spot 60 ILS User Manual Rev. 2
18
Technical Specifications
6. Technical Specifications
Dimensions and Weight
LengthWidthHeightWeight
11.4 in (290 mm)11.9 in (301 mm)15.4 in (391 mm)22 lb (9.9 kg)
Note: Dimensions in inches rounded to the nearest hundredth.
Power
Power Supply TypeRangeVoltage Selection
Switching (internal)100 to 240 VAC, 50/60 HzAuto-ranging
Parameter120 V, 60 Hz230 V, 50 Hz
Consumption110 W107 W
Operating Current0.9 A0.5 A
FuseT 2 A, 250 VT 2 A, 250 V
Power I/OU.S./WorldwideUK/Europe
Power cord plugEdison (U.S.)Local plug
Light Source
TypeQuantityColorPowerCurrentLifespan
LED1Cool white70 W4.8 A50,000 hours
Photometrics
Strobe RateZoom RangeIlluminance @ 2 m (13°) Illuminance @ 2 m (19°)
0 to 23 Hz13°–19°16,932 lux9,424 lux
Thermal
Maximum External TemperatureCooling System
104 °F (40 °C)Convection
DMX
Input/OutputChannel Range
3-pin XLR8, 10, or 14
Ordering
Product NameItem CodeUPC Number
Intimidator Free Spot 60 ILS10012030
781462223786
19
Intimidator Free Spot 60 ILS User Manual Rev. 2
Contact Us
Contact Us
Chauvet World Headquarters
Chauvet U.K.
Chauvet Benelux
Chauvet France
Chauvet Germany
Chauvet Mexico
Address: Av. de las Partidas 34 - 3BEmail: servicio@chauvet.com.mx
Zona Industrial LermaWebsite: www.chauvetprofessional.mx
Lerma, Edo. de México, CP 52000
Voice: +52 (728) 690-2010
Warranty & Returns
For warranty terms and conditions and return information, please visit our website.
For customers in the United States and Mexico: www.chauvetlighting.com/warranty-registration
For customers in the United Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg,
France, and Germany: www.chauvetlighting.eu/warranty-registration
.
Intimidator Free Spot 60 ILS User Manual Rev. 2
.
20
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.