Chauvet DJ Hurricane Haze 1D User manual

User Manual
Table of Contents
1. Before You Begin ........................................................................... 3
What Is Included ........................................................................................... 3
Unpacking Instructions .................................................................................. 3
Claims ........................................................................................................... 3
Text Conventions .......................................................................................... 3
Icons .............................................................................................................. 3
Document Information ................................................................................... 3
Product at a Glance ...................................................................................... 4
Safety Notes .................................................................................................. 4
2. Introduction .................................................................................... 5
Product Overview .......................................................................................... 5
Product Dimensions ...................................................................................... 6
3. Setup ............................................................................................... 7
AC Power ...................................................................................................... 7
Fuse Replacement ................................................................................................. 7
Mounting ....................................................................................................... 8
Orientation ............................................................................................................. 8
Rigging ................................................................................................................... 8
4. Operation ........................................................................................ 9
Control Panel Operation................................................................................ 9
Fluid Tank Indicator LEDs ............................................................................. 9
Wired Timer Remote Operation .................................................................. 10
Menu Map ................................................................................................... 11
Configuration (DMX) ................................................................................... 11
Starting Address .......................................................................................... 11
Configuration (Standalone Mode) ............................................................... 11
Manual Mode ....................................................................................................... 11
DMX Channel Assignments and Values ..................................................... 11
1-CH ..................................................................................................................... 11
5. Technical Information .................................................................. 12
Hazer Maintenance ..................................................................................... 12
Storage ........................................................................................................ 12
General Troubleshooting............................................................................. 13
Returns .............................................................................................. 14
Contact Us .......................................................................................... 15
Page 2 of 16 Hurricane Haze 1D User Manual Rev. 1
6. Technical Specifications .............................................................. 16

1. Before You Begin

What Is

Unpacking
Instructions

Immediately upon receiving this product, carefully unpack it and check the container in

Claims

If the container or the material inside the container (the product and included
For other issues such as missing components or parts, damage not related to

Text
Conventions

<Menu>
A key to be pressed on the product’s control panel
1–512
A range of values 50/60
A set of values of which only one can be chosen
Menu > Settings
A sequence of menu options to be followed
ON
A value to be entered or selected

Icons

Document
The information and specifications contained in this document are subject to change
assumes no responsibility or liability for any errors or
Hurricane Haze 1D
Included
Power cord
FC-T remote controller
Hanging bracket with mounting hardware
Warranty card
Quick Reference Guide
which you received it.
accessories) appear damaged from shipping, or show signs of mishandling, upon receipt notify the carrier immediately, not Chauvet. Failure to do so in a timely manner may invalidate your claim with the carrier. In addition, keep the container and all the packing material for inspection.
shipping, or concealed damage, file a claim with Chauvet within seven (7) days of receiving the merchandise.
Information
Settings
Icon Meaning
A menu option not to be modified (for example, showing the operating mode/current status)
Critical installation, configuration, or operation information. Failure to comply with this information may render the product partially or completely inoperative, cause damage to the product, or cause harm to the user.
Important installation or configuration information. Failure to comply with this information may prevent the product from functioning correctly.
Useful information.
without notice. Chauvet omissions that may appear in this manual.
© Copyright 2016 Chauvet. All rights reserved.
Electronically published by Chauvet in the United States of America.
Convention Meaning
Hurricane Haze 1D User Manual Rev. 1 Page 3 of 16
Product at a
Glance
x
x
Outdoor Use
x
Auto-ranging Power Supply
x
Sound-Activated
x
Replaceable Fuse
P
DMX
P
User-Serviceable
x
Master/Slave
x
Duty Cycle
x

Safety Notes

Please read the following Safety Notes carefully before working with the product. The Notes include important safety information about installation,
between cleanings, to increase the life of your product.
Use on Dimmer
usage, and maintenance.
Always connect the product to a grounded circuit to avoid the risk of electrocution.
Always disconnect this product from the power source before cleaning it or
replacing the fuse.
Make sure the power cord is not crimped or damaged.
Never disconnect the power cord by pulling or tugging on the cord.
Do not touch the output nozzle on this product. It is very hot during operation and
it may remain hot for several hours after turning the unit off.
If mounting this product overhead, always secure it to a fastening device using a safety cable.
Do not mount this product on a flammable surface (e.g., wood, linoleum, carton, plastic, or carpet).
Always make sure that the voltage of the outlet to which you are connecting the product is within the range stated on the decal or rear panel of the product.
Keep this User Manual for future consultation. If you sell this product to another user, be sure that they also receive this document.
This product is for indoor use only! To prevent risk of fire or shock, do not expose this product to rain or moisture.
Make sure there are no flammable materials close to the unit while operating.
Always install this product in a location with adequate ventilation, at least
20 in (50 cm) from adjacent surfaces.
Be sure that no ventilation slots on the unit’s housing are blocked.
Make sure to replace the fuse with another of the same type and rating.
The maximum ambient temperature (Ta) is 104 °F (40 °C). Do not operate this
product at higher temperatures.
In the event of a serious operating problem, stop using the unit immediately.
Never try to repair this pr od uct . Repairs carried out by unskilled people can lead
to damage or malfunction. Please contact the nearest authorized technical assistance center.
Never connect this product to a dimmer pack.
Make sure there are no flammable materials close to the unit while operating.
Depending on the amount of fog/haze generated, all fog machines may set off
smoke detector s.
Do not use for space heating purposes.
Use only CHAUVET water-based haze fluid.
Drain the tank before transporting the product.
To eliminate unnecessary wear and improve its lifespan, during periods of non-
use completely disconnect the product from power via breaker or by unplugging it.
FCQ (Fog Cleaner Quart) was specifically developed by Chauvet to clean your Hurricane Haze 1D. Make sure you use FCQ regularly, no longer than 90 days
Auto Programs
Page 4 of 16 Hurricane Haze 1D User Manual Rev. 1

2. Introduction

Product Overview

LED Display
DMX In/Out
Remote Control
Receiver Port
Power In
Fuse Holder
On/Off Switch
Wireless Remote
Manual Fog
Button
Fluid Level
Indicator
Fluid Tank
Hurricane Haze 1D User Manual Rev. 1 Page 5 of 16

Product Dimensions

12.80 in 325 mm
12.52 in 318 mm
9.84 in 250 mm
5.95 in 151 mm
7.95 in 202 mm
10.55 in 268 mm
Page 6 of 16 Hurricane Haze 1D User Manual Rev. 1

3. Setup

AC Power

Fuse Replacement

The product does not ship with a spare fuse; however, the safety cap has room for
Spare fuse holder (inside safety cap)
Installed fuse (held by plastic clip)
Safety cap
This product can work with an input voltage of either 120 VAC, 60 Hz or 230 VAC, 50 Hz depending on the model.
To determine the power requirements for a particular product, see the label affixed to the back plate of the product or refer to the product’s specifications chart. The l isted current rating indicates the product’s average current draw under normal conditions.
Always connect this product to a protected circuit (circuit breaker or fuse), making sure that it has an appropriate electrical ground to avoid the risk of electrocution or fire.
Never connect this product to a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel serves only as a 0 to 100% switch.
Disconnect this product from the power outlet before replacing the fuse.
1. Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
2. Pry the fuse out of the housing.
3. Remove the blown fuse from the holder and replace with a fuse of the exact same
type and rating.
4. Insert the fuse holder back in place and reconnect power.
a spare.
Hurricane Haze 1D User Manual Rev. 1 Page 7 of 16

Mounting

Orientation

provided there is

Rigging

Rubber Feet
Safety Cable
Mounting Clamp
The Hurricane Haze 1D may be mounted in any position adequate room for ventilation around it.
Be sure that the structure or surface onto which you are mounting this product can support its weight. Please see the Technical Specifications section of this manual for weight information.
Make sure to mount the product securely to a rigging point, whether an elevated platform or a truss.
When rigging this product onto a truss, you should use a mounting clamp of appropriate weight capacity. The bracket has a 13 mm hole, which is appropriate for this purpose.
When mounting this product overhead, always use a safety cable. Before deciding on a location for this product, always make su re t hat it will be easy
to access the unit for maint en a nce and programming purposes. When po wer linki ng multi ple products, you must always consider the length of the
power linking cable and mount the products close enough for the cable to reach them.
The bracket knobs allow for directional adjustment when aiming the product to the desired angle. Only loosen or tighten the bracket knobs using your bare hands. Using tools could damage the knobs.
Mounting Diagram
Page 8 of 16 Hurricane Haze 1D User Manual Rev. 1

4. Operation

Control
Operation
buttons located underneath the
Button
Function
<MENU>
Exits from the current menu or function
Navigates upwards through the menu list and increases the numeric value when in a function
Navigates downwards through the menu list and decreases the numeric value when in a function
<ENTER>
Enters into a menu or sets the currently displayed value
Important note regarding the priority level for the three types of methods used
3. Digital display
Fluid Tank
Indicator
Note: The Hurricane H aze 1D may be operational while the heater is warming up and
normal operation.
To access the control panel functions, use the 4
Panel
display.
<UP>
<DOWN>
to control the operation of your Hurricane Haze 1D.
A DMX controller will take priority control over the digital display and Remote Control. The priority control levels are:
1. DMX
2. Remote controller
Indicator LEDs show the status of the fill tank, as follows:
Red - the heater is currently warming up
LEDs
Blue - the hazer is ready
Flashing Blue - the fluid tank requires refilling
may emit bu rs ts o f fo g while resetting it s el f or while the fluid t an k is heating. This is
See the General Troubleshooting section to identify possible sources of trouble and find solutions.
Hurricane Haze 1D User Manual Rev. 1 Page 9 of 16
Wired Timer
Operation
Interval
Adjustment
Timer LED
Manual LED
Manual/Power
LED
Manual Control Continuous
Timer On/Off
Latching Button
Duration
Output
OUTPUT
Important: Using the Control Board, set the Haze (HAZe) output to 0. You can then
Remote
The wired timer c ontr oller a llows you to automaticall y trigg er f og out put by setting interval and dur at io n times. LED indicator lights displa y the m achine and contr oller’s c urrent s tate. Rotar y knobs s et interva l and duration times, while manual and continuous buttons allow overriding control.
1. Plug in the fog machine to power and turn the power switch to the product on.
2. Plug in the timer controller to the Manual Controller socket on the back of the fog machine.
3. Press the <TIMER ON/OFF> latching button on the timer controller. The Timer LED Indicator above the button will light up. The <TIMER ON/OFF> latching button will remain on until it is pressed again.
4. Set the INTERVAL, DURATION, and OUTPUT adjustment knobs to the desired positions.
INTERVAL knob sets the amount of time in between bursts of fog
DURATION knob sets the length of time that the fog machine will run during the burst
OUTPUT knob adjusts the fog output
connect and operate the included wired remote with the Hurricane Haze 1D.
5. Press the <CONTINUOUS> latching button and the fog machine outputs fog until the button is pressed again. The Manual/Power LED Indicator above the button will light up during continuous operation.
Note: The duration of continuous fog output is based on the capability of the fog machine.
6. Press the <MANUAL> button to momentarily output fog. The fog machine will output fog for as long as you hold down the button. During manual operation the Manual Momentary LED Indicator above the button will light up.
Note: The duration of manual fog output is based on the capability of the fog machine.
Adjustment
Adjustment
Indicator
Momentary
Momentary Button
Latching Button
Page 10 of 16 Hurricane Haze 1D User Manual Rev. 1

Menu Map

Mode
Programming Steps
Description
HAZe
h 0~h 3
Output Low~High
Ht
H _ _ _
Shows current temperature
Addr
d 1~512
Selects the DMX starting address
Configuration
Starting
channel mode for basic
the number of DMX
Configuration
Mode)

Manual Mode

DMX Channel Assignments and V alues

1-CH
1
Output
000 ó 255
Low~High
Set this product in DMX mode to control it with a DMX controller.
(DMX)
Connect this product to a suitable power outlet.
Turn this product on.
Connect a DMX cable from the DMX output of the DMX controller to the
DMX input socket of this product.
The Hurricane Haze 1D has one DMX personality, a 1-
Address
control. The Hurricane Haze 1D uses 1 channel in DMX mode, which defines the highest
configurable address to 512. When selecting a starting DMX address, always consider
channels the selected DMX mode uses. If you choose a starting address that is too high, you could restrict the access to some of the product’s channels.
If you are not familiar with the DMX protocol, download the DMX Primer from
www.chauvetlighting.com
.
To select the starting address, do the following:
1. Press <MENU> repeatedly until d*** shows on the display.
2. Use <UP> or <DOWN> to select the starting address.
(Standalone
Set this product in one of the standalone modes to control it without a DMX controller.
1. Connect this product to a suitable power outlet.
2. Turn this product on.
Never connect a product that is operating in any standalone mode, whether Static, Automatic, or Sound to a DMX string connected to a DMX controller. Products in standalone mode may transmit DMX signals that could interfere with the DMX signals from the controller.
To enable the Automatic Mode, follow the instructions below:
1. Press <MENU> repeatedly until h*** shows on the display.
2. Use <UP> or <DOWN> to adjust the haze volume.
Channel Function Value Setting
Hurricane Haze 1D User Manual Rev. 1 Page 11 of 16

5. Technical Information

Hazer Maintenance

to become clogged. After every 40 hours of continuous
between cleanings, to increase the life of your product.

Storage

on a monthly basis to achieve the best
Do not allow the hazer operation, use CHAUVET Fog Cleaner Quart (FCQ) through the system to prevent the accumulation of particulate matter in the heating element.
The recommended cleaning procedure is as follows.
1. Unplug the product from power.
2. Empty all fog fluid from the machine.
3. Add cleaning solution to the tank.
4. Connect the product to power and allow it to warm up.
5. Run the unit in a well-venti late d area until th e tank is almost empty . Do not allow the pump to run dry.
6. Refill with hazer fluid to continue using the hazer. Run the machine briefly to clear any remaining cleaning solution from the pump and heater.
Do not operate the machine without fluid at any time.
Fog Cleaner Quart (FCQ) was specifically developed by Chauvet to clean your Hurricane Haze 1D. Make sure you use FCQ regularly, no longer than 90 days
Before storing the hazer, run FCQ through the system as described in the cleaning procedure above; however, only follow steps 1 through 5. Do not refill the tank with fog fluid if storing the hazer. Cleaning the system prior to storage will help prevent any particles from condensing inside the pump or heater while not in use.
Test-run your Hurricane Haze 1D performance.
Page 12 of 16 Hurricane Haze 1D User Manual Rev. 1

General Troubleshooti ng

Allow the product to warm up completely. This should take less than 10 Allow the product to warm up completely.
Turn fog machine 45° to flatten out the bubble and allow the fog fluid to
Turn off the product for 5 seconds, and then turn it back on. Repeat as Note: After more than 10 attempts, contact Customer Service.
Clean thoroughly with CHAUVET FCQ. For full instructions, see Hazer Blocked pipes
Contact Customer Service
Failing part
Contact Customer Service
Clean thoroughly with CHAUVET FCQ. For full instructions, see Hazer
Maintenance. Refill with CHAUVET water-based haze fluid.
Failing part
Contact Customer Service
Maintenance. Refill with CHAUVET water-based haze fluid.
Blocked pipes
Contact Customer Service
Failing part
Contact Customer Service
Normal
Blue
Normal
Normal function
circuit
nominal current
Short circuit along the Change to another outlet
Loose or damaged power Blown fuse
Replace blown fuse with a good one of the same type and rating
Internal problem
Send product for repair
Use the right fader(s) on the controller
Wrong DMX personality on
Set the correct DMX product’s personality the DMX controller
Loose or damaged DMX Internal problem
Send product for repair
Interference with AC or radio signals
Too many products connected
Terminator not connected
Install a terminator, as indicated in the “DMX Primer” section.
Symptom Indicator Status Possible Cause Possible Action
No output or short output
Spitting fluid
Circuit breaker or fuse keeps blowing
Red Heater warming up
Red flashing Air bubble in fluid line
Incorrect fluid
Blue
Incorrect fluid
Blue blinking
Blue
N/A
Blocked pipes Contact Customer Service
Incorrect fluid
Excessive load on the
power lines
No energy on power outlet
minutes.
flow properly
necessary.
Maintenance. Refill with CHAUVET water-based haze fluid.
Clean thoroughly with CHAUVET FCQ. For full instructions, see
Make sure that the total load does not e xceed 80% of t he br eak er or fuse
Check the power lines and power cords
Check power outlet
Hazer
Product does not power up
Product does not respond to DMX
Blue
Intermittent DMX Problems
If you still experience problems after trying the solutions presented here, contact Chauvet Technical Support.
cord
Wrong starting address on the product
the product Wrong polarity setting on
cable
Signal cables are not DMX compatible
DMX cable too long
Check the power cord
Set the correct starting address on the product
Assign the faders accordingly
Change the signal polarity on the controller
Check the DMX cable before the faulty unit
Replace non DMX cables with tr ue D M X cabl es
Keep DMX cables away from AC wires or radi o equi pm ent
Install an optically coupled DMX amplifier right before the product with intermittent problems
Install an optically coupled DMX amplifier after unit #32
Hurricane Haze 1D User Manual Rev. 1 Page 13 of 16
R
To return a product or request support:
distributors outside the U.S., United Kingdom, Ireland, or Mexico.
If you live outside the U.S., United Kingdom, Ireland, or Mexico, contact your distributor
products to them.
Call the corresponding Chauvet Technical Support office and request a Return Merchandise Authorization (RMA)
Clearly label the package with the RMA number. Chauvet will refuse any product returned without an RMA number.
label. DO NOT write the RMA number
Before sending the product, clearly write the following information on a piece of paper and place it inside the box:
responsibility. FedEx packing or double-boxing is recommended.
ETURNS
In the U.S., contact Chauvet World Headquarters (see Contact Us).
In the UK or Ireland, contact Chauvet Europe Ltd. (see Contact Us).
In Mexico, contact Chauvet Mexico (see Contact Us).
In any other country, DO NOT contact Chauvet. Contact your distributor. See www.chauvetlighting.com for
number before shipping the product. Be prepared to provide the model number, serial number, and a brief description of the cause for the return. You must send the merchandise prepaid, in its original box, and with its original packing and accessories. Chauvet will not issue call tags.
Write the RMA number on a properly affixed
Your name
Your address
Your phone number
RMA number
A brief description of the problem
Be sure to pack the product properly. Any shipping damage resulting from inadequate packaging will be your
Chauvet reserves the right to use its own discretion to repair or replace returned
of record and follow their instructions on how to return Chauvet Visit our website for contact details.
directly on the box.
product(s).
Page 14 of 16 Hurricane Haze 1D User Manual Rev. 1
C
USA WORLD HEADQUARTERS
General Information – Chauvet
Technical Support
www.chauvetlighting.com
EUROPE
General Information - Chauvet Europe BVBA
Technical Support
General Information - Chauvet Europe Ltd.
Technical Support
MEXICO
General Information - Chauvet Mexico
Voice: +52 (728) 285-5000
Technical Support
www.chauvet.com.mx
Outside the U.S., United Kingdom, Ireland, Mexico, or Benelux contact the dealer of record. Follow their instructions to request support or to return a product. Visit our website for contact details.
ONTACT
US
Address: 5200 NW 108th Avenue Sunrise, FL 33351 Voice: (954) 577-4455 Fax: (954) 929-5560 Toll free: (800) 762-1084
Address: Stokstraat 18 9770 Kruishoutem Belgium Voice: +32 9 388 93 97
Address: Unit 1C Brookhill Road Industrial Estate Pinxton, Nottingham, UK NG16 6NT Voice: +44 (0)1773 511115 Fax: +44 (0)1773 511110
Address: Av. Santa Ana 30 Parque Industrial Lerma Lerma, Mexico C.P. 52000
Voice: (954) 577-4455 (Press 4) Fax: (954) 756-8015 Email: tech@chauvetlighting.com
World Wide Web
Email: Eutech@chauvetlighting.eu
World Wide Web
www.chauvetlighting.eu
Email: uktech@chauvetlighting.com
World Wide Web
www.chauvetlighting.co.uk
Email: servicio@chauvet.com.mx World Wide Web
Hurricane Haze 1D User Manual Rev. 1 Page 15 of 16

6. Technical Specifications

Dimensions and
Length
Width
Height
Weight
12.5 in (318 mm)
10.5 in (268 mm)
9.8 in (250 mm)
8.4 lb (3.7 kg)
Note: Dimensions in inches rounded to the nearest decimal digit.
Power
Power Supply Type
Range
Voltage Selection
120 V, 60 Hz 230 V, 50 Hz
Parameter
120 V, 60 Hz
230 V, 50 Hz
Consumption
840 W (6.8 A)
840 W (3.7 A)
Fuse size
F 10 A, 250 V
F 10 A, 250 V
Power I/O
Input
Connectors
IEC
Cord plug
Edison
Operation
Heat-up Time
Tank Capacity
Fluid Consumption
1 min
1.5 l
10 ml/min
Fog output
CFM
700
Approved Fluids
Chauvet Haze Fluid (Gallon)
HFG
Thermal
Maximum External Temp.
Cooling System
104 °F (40 °C)
Convection
DMX
I/O Connectors
Connector Type
Channel Range
3-pin XLR
Sockets
2
Ordering
Product Name
Item Code
UPC Number
09071158 (120 V) 09071159 (230 V)
781462215064 781462215071
Weight
Model-specific
or
Fixed voltage
Hurricane Haze 1D
Page 16 of 16 Hurricane Haze 1D User Manual Rev. 1
UL 499
CSA C22.2 No. 64
Loading...