Page 1
User Manual
Page 2
TABLE OF CONTENTS
What is Included ................................................................................................ 3
Unpacking Instructions ...................................................................................... 3
Claims ........................................................................................................................ 3
Text Conventions .............................................................................................. 3
Icons .................................................................................................................. 3
Document Information ....................................................................................... 3
Product at a Glance .......................................................................................... 4
Safety Notes ...................................................................................................... 4
Product Overview .............................................................................................. 5
3. Setup .................................................................................................. 6
AC Power .......................................................................................................... 6
Fuse Replacement ..................................................................................................... 6
Mounting ........................................................................................................... 7
Orientation ................................................................................................................. 7
Rigging ....................................................................................................................... 7
4. Operation ........................................................................................... 8
Manual Local Operation .................................................................................... 8
Manual Remote Operation ................................................................................ 8
Timer Remote Operation................................................................................... 8
Wireless Remote Operation ............................................................................ 10
5. Technical Information ......................................................................11
Fogger Maintenance ....................................................................................... 11
Storage ............................................................................................................ 11
General Troubleshooting................................................................................. 12
Returns ..................................................................................................13
RMA ................................................................................................................ 13
Contact Us ............................................................................................14
6. Technical Specifications ..................................................................15
Page 2 of 2 Hurricane™ 901 User Manual Rev. 4
Page 3
Immediately upon receiving this product, carefully unpack it and check the container in which you received it. Make sure that you have received all the parts indicated above
ntainer (this product and any other accessory included with it)
appears damaged from shipping, or if the container shows signs of mishandling, notify
upon reception of the damaged merchandise.
ely manner may invalidate your claim with the carrier. In addition,
For other issues such as missing components or parts, damage not related to shipping,
within seven (7) days of
<Menu>
A key to be pressed on the fixture’s control panel
1–512
A range of values
50/60
A set of values of which only one can be chosen
Claims
A section or chapter in this document
A menu option not to be modified (for example, showing the operating mode/current statu s)
Menu > Settings
A sequence of menu options to be followed
ON
A value to be entered or selected

Icons

This paragraph contains critica l instal lat ion, con fig ur ati on, or
damage to the fixture, or cause harm to the user.
This paragraph contains important installation or configuration the fixture from functioning correctly.
Document
are subject to change
reserves the right to update the existing

1. BEFORE YOU BEGIN

What is
Included
Unpacking
Instructions

Claims

Text
Conventions
Hurricane™ 901
Wired Remote
Power Cord
and that they are all in good condition.
If the material inside the co the shipper immediately, not Chauvet,
Failure to do so in a tim retain the container and all the packing material for inspection.
or concealed damage, you should make claims to Chauvet receiving the merchandise.
Convention Meaning
Settings
Warranty Card
Quick Reference Guide
Icon Meaning
operation information. Failure to comply with this information may
The information and specifications contained in this document
Information
Hurricane™ 901 User Manual Rev. 4 Page 3 of 3
without notice. Chauvet assumes no responsibility or liability for any errors or omissions that may appear in this manual. Chauvet document or to create a new document to correct any errors or omissions.
You can download the latest version of this document from www.chauvetlighting.com.
© Copyright 2014 Chauvet. All rights reserved
Electronically published by Chauvet in the United States of America
Author Date Editor Date
A. Leon 10/21/14 M. Trouard 10/21/14
render the fixture partially or completely inoperative, cause
information. Failure to comply with this information may prevent
This paragraph reminds you of useful, although not critical, information.
Page 4
Product at a
x
x
x
P
x
P
x
x
x
x

Safety Notes

hey
The fog exits the nozzle at a very high temperature. Keep a minimum distance of 6.5
emergency number (911 in the US) and seek help.
completely disconnect the product from power via breaker or by unplugging it.
Keep this User Manual for future consultation. If you sell this product to another user,
between cleanings, to increase the life of your fogger.
Glance
Use on Dimmer Outdoor Use Sound Activated DMX Master/Slave Please read the following notes carefully before starting to work with this product. T
include important safety information about its installation, usage, and maintenance.
Always connect this product to a grounded circuit to avoid the risk of electrocution.
Always disconnect this product from the power source before cleaning it or replacing
the fuse.
Make sure the power cord is not crimped or damaged.
Never disconnect this produ ct fr om power cord by pulling or tugging on the cord.
If mounting this product overhead, always secure it to a fastening device using a
safety cable.
Make sure there are no flammable materials close to the unit while operating.
Do not touch this product’s housing when operating because it may be very hot.
Do not mount this product on a flammable surface (linoleum, carpet, wood, paper,
carton, plastic, etc.)
This product’s nozzle is very hot during operation and it rema ins hot for a long time after operation has stopped.
ft (2 m) from the nozzle to the nearest object.
Do not use this product as a space heater.
Do not add flammable liquids (alcohol, perfume, gasoline, kerosene, solvents, etc.)
to the flog fluid.
Avoid ingesting the fog fluid. If that happens, immediately call the medical
Auto Programs Fixed voltage (120 V / 230 V) Replaceable Fuse User Serviceable Duty Cycle
Always make sure that the voltage of the outlet to which you are connecting this product is within the range stated on the decal or rear panel of the fixture.
This product is for indoor use only! (IP20) To prevent risk of fire or shock, do not expose this fixture to rain or moisture.
Always install this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
Be sure that no ventilation slots on the unit’s housing are blocked.
Never connect this product to a dimmer pack.
Make sure to replace the fuse with another of the same type and rating.
Never carry this product from the power cord. Always use the mounting bracket.
The maximum ambient temperature (Ta) is 104° F (40° C). Do not operate this
product at higher temperatures.
In the event of a serious operating problem, stop using the unit immediately.
Never try to repair this product. Repairs carried out by unskilled people can lead to
damage or malfunction. Please contact the nearest authorized technical assistance center.
Use only CHAUVET® water-based fog fluid.
Drain the tank before transporting the product.
To eliminate unnecessary wear and improve its lifespan, during periods of non-use
be sure that they also receive this document.
FCQ (Fog Cleaner Quart) was specifically developed by Chauvet to clean your
Hurricane™ 1101. Make sure you use FCQ regularly, no longer than 90 days
Page 4 of 4 Hurricane™ 901 User Manual Rev. 4
Page 5

2. INTRODUCTION

Product Overview

Fluid tank cap
Mounting holes
Mounting bracket
Nozzle
Bracket adjustment knob
Safety loop
Fluid tank
Remote connector
Manual fog button
Power input
Fuse holder
Fluid level indicator
Power switch
Back Panel
Hurricane™ 901 User Manual Rev. 4 Page 5 of 5
Page 6
fogger matches the voltage of
ther 120 V or 230 V.
void its warranty and it
this product (circuit breaker, power outlet, and
(circuit breaker or fuse),
an appropriate electrical ground to avoid the risk of
a rheostat (variable resistor) or dimmer circuit, even
Fuse
it in
Although the safety cap does have room for a spare fuse, this product ships with
Installed fuse (held by plastic clip)
Spare fusel
(inside safety cap)
Safety cap

3. SETUP

AC Power

Replacement
This product has a fixed voltage power supply and it can work with an input voltage of either 120 V, 60 Hz or 230 V, 50 Hz, depending on the specific model.
Make sure that the model of your Hurricane™ 901 the power outlet to which you want to connect it, whe Connecting this product to the wrong input voltage would may permanently damage the Hurricane™ 901.
To determine the power requirements for wiring), use the current value listed on the label affixed to the product’s back panel, or refer to the product’s specifications chart. The listed current rating indicates the product’s average current draw under normal conditions.
Always connect this product to a protected circuit making sure that it has electrocution or fire.
Never connect this product to if the rheostat or dimmer channel serves only as a 0 to 100% switch.
This product uses an F 10 A, 250 V fuse. Follow the instructions below to change case it blows.
Disconnect this product from the power outlet before replacing the fuse.
1) Wedge the tip of a flat head screwdriver into the slot of the fuse holder and pry it out of its housing.
2) Remove the blown fuse from its holder and replace it with a fuse of the exact same type and rating.
3) Insert the fuse holder back into its place, and reconnect power.
Always replace a blown fuse with a good fuse of the same type and rating.
no spare fuse.
Page 6 of 6 Hurricane™ 901 User Manual Rev. 4
Page 7

Mounting

Before mounting this product, read and follow the safety recommendations indicated in
may be mounted in any position, provided there is adequate room

Rigging

Before deciding on a location for this product, always make sure that it will be easy to
section of this manual for
Mount the fixture
of appropriate
appropriate for this
on the floor,
Bracket adjustment knob
Mounting holes
Mounting
bracket
Safety
loop
Clamp (not
included)
the Safety Notes section (page 2 of this manual).

Orientation

The Hurricane™ 901 for ventilation around it.
access the unit for maintenance and fluid replenishment purposes. Make sure that the structure or surface onto which you are mounting this product can
support its weight. Please see the Technical Specifications weight information.
When mounting this product overhead, always use a safety cable. securely to a rigging point, whether an elevated platform or a truss.
When rigging this product onto a truss, you should use a mounting clamp weight capacity. The bracket has three M8 size holes, which are purpose.
The bracket adjustment knobs allow for directional adjustment when aiming the product to the desired angle. Only loosen or tighten the bracket knobs using your bare hands. Using tools could damage the knobs.
The rubber feet allow for surface mounting. When mounting this fixture make sure that the fixture and its cables are away from people and vehicles. Refer to the Safety Notes section (page 2 of this manual)
Mounting Diagram
Hurricane™ 901 User Manual Rev. 4 Page 7 of 7
Page 8
Manual
comes with a wired
. This
allows the user to start and stop the fog
To operate this product, follow the instructions
The Hurricane™ 901 unit may stop producing fog to allow for fluid reheating after
can operate with the
optional wired timer remote control (model
T). This control allows the user to start and
stop the fog output manually, as well as to
To operate this product, follow the instructions

4. OPERATION

Manual Local
Operation
Remote
Operation
To operate the Hurricane™ 901, do the following:
1) Plug the fog machine into power and turn the power switch to the fixture on.
2) Press <FOG> on the rear of the fog machine to trigger the fog output. The fog will start.
3) Release the button to stop the fog output.
The Hurricane™ 901 manual remote control (model FC-M) control output.
below:
1) Plug the fog machine into power and turn the power switch to the fixture on.
2) Plug in the wired manual remote FC-M into the Remote Control socket on the rear of the fog machine.
3) Press <FOG> on the remote to trigger the fog output. The fog will start.
4) Release the button to stop the fog output.
a period of continuous fog output. This is a normal occurrence.
Timer Remote
Operation
The Hurricane™ 901 FC­operate the Hurricane™ 901 in timer mode.
below:
1) Plug the fog machine into power and turn
2) Plug in the wired timer remote FC-T into the
Timer operation
1) Press and latch <TIMER ON/OFF> on the
2) Use the INTERVAL knob to adjust the time
3) Use the DURATION knob to adjust the
the power switch to the fixture on
Remote Control socket on the rear of the fog machine.
FC-T remote. The yellow LED should illuminate.
between bursts of fog.
duration of each burst of fog.
Continues on the next page
Page 8 of 8 Hurricane™ 901 User Manual Rev. 4
Page 9
Timer Remote
The Hurricane™ 901 unit may stop producing fog to allow for fluid reheating after
Manual Continuous Operation
Operation
(Cont.)
1) For continuous operation, press and latch <CONTINUOUS> on the FC-T remote. The red LED should illuminate.
2) The Hurricane™ 901 will continue generating fog until you press <CONTINUOUS> again to unlatch it.
Make sure to press <CONTINUOUS> again to stop the fog output.
Manual Burst Operation
1) For burst operation, press <MANUAL> on the FC-T remote. The green LED should illuminate.
2) The Hurricane™ 901 will continue generating fog until you release <MANUAL>.
a period of continuous fog output. This is a normal occurrence.
Continued from previous page
Hurricane™ 901 User Manual Rev. 4 Page 9 of 9
Page 10
Wireless
remote control (model
manually without the
W consists of a receiver and a key chain transmitter. The transmitter has four
to tune it on one of those four channels. This allows the operator to control up
units. It is also possible to control more than four
receiving channel to more than one
2
ON
The Hurricane™ 901 unit may stop producing fog to allow for fluid reheating after
Red LED
(Send)
Fog
Triggers
Antenna
Key chain Loop
Sliding Key Cover
Receiver
Transmitter
Green
LED
(Ready)
Red LED (Heating)
DIP
Switches
The Hurricane™ 901 can operate with the optional wireless FC-W). This control allows the user to start and stop the fog output
Remote
Operation
limitations of the wired remote controls. The FC-
control buttons, each of them assigned to a specific channel. The receiver has four DIP switches to four independent Hurricane™ 901 Hurricane™ 901 units by assigning the same Hurricane™ 901 unit.
To operate this product, follow the instructions below:
1) Plug the fog machine into power and turn the power switch to the fixture on.
2) Plug in the wireless remote control receiver FC-W into the Remote Control socket on the rear of the fog machine.
3) Select the receiving channel by configuring the DIP switch as follows:
Channel
1 2 3 4
1 ON
Off
3 4
Off Off Off Off Off
DIP Switches
Off Off Off
Off Off
ON
Off
ON
4) Press the corresponding button on the FC-W transmitter and the Hurricane™ 901 will output fog for as long as you keep that button pressed.
a period of continuous fog output. This is a normal occurrence.
Page 10 of 10 Hurricane™ 901 User Manual Rev. 4
Page 11
hours of continuous
Fog Cleaner Quart (FCQ) through the system to prevent the
ecifically developed by Chauvet to clean your
no longer than 90 days
between cleanings, to increase the life of your product.

Storage

, run FCQ through the system as described in the cleaning
. Do not refill the tank with
Cleaning the system prior to storage will help prevent
on a monthly basis to achieve the best

5. TECHNICAL INFORMATION

Fogger
Maintenance
Do not allow the fogger to become clogged. After every 40 operation, use CHAUVET® accumulation of particulate matter in the heating element.
The recommended cleaning procedure is as follows.
1. Unplug the product from power.
2. Empty all fog fluid from the machine.
3. Add cleaning solution to the tank.
4. Connect the product to power and allow it to warm up.
5. Run the unit in a well-venti late d area until the ta nk is almost empty . Do not allow
the pump to run dry.
6. Refill with fogger fluid to continue using the fogger. Run the machine briefly to clear
any remaining cleaning solution from the pump and heater.
Do not operate the machine without fluid at any time.
Fog Cleaner Quart (FCQ) was sp Hurricane™ 901. Make sure you use FCQ regularly,
Before storing the fogger procedure above; however, only follow steps 1 through 5
fog fluid if storing the fogger.
any particles from condensing inside the pump or heater while not in use.
Test-run your Hurricane™ 901 performance.
Hurricane™ 901 User Manual Rev. 4 Page 11 of 11
Page 12

General Troubleshooting

Clean thoroughly with CHAUVET® FCQ. For Refill with CHAUVET® water-based fog fluid.
Blocked pipe or failing part
Contact Customer Service
Excessive load on the circuit
Make sure that the total load does not exceed 80% of the breaker or fuse nominal current
Short circuit along the power lines
Check the power lines and power cords
No energy on power outlet
Check power outlet Change to another outlet
Loose or damaged power cord
Check the power cord
Blown fuse
Replace blown fuse with a good one of the same type and rating
Internal problem
Send product for repair
No fluid
Turn the product off and replenish the fog fluid (use only Chauvet fog fluid)
Heater or pump clogged
Use Chauvet cleaner to free the path.
Wired remote disconnected or
Make sure that the remote is connected 901
Inappropriate wired remote operation
Read the instructions for both wired remote units
Wireless remote receiver not connected
Make sure that the wireless remote receiver is connected
Wireless remote transmitter ran out of battery
Replace battery on wireless remote transmitter
Wireless remote pair needs configuration
Make sure to configure the wireless remote pair as per the instructions in this manual
Internal problem
Send the product for repair
Symptom Possible Cause Possible Action
No output or fog machine is spitting fluid
Circuit breaker or fuse keeps blowing
Product does not power up
Product does not output fog
Incorrect fluid
defective
full instructions, see Fogger Maintenance.
Try the remote on another HURRICANE™
If you still experience problems after trying the above solutions, contact Chauvet Technical Support. See Contact Us.
Page 12 of 12 Hurricane™ 901 User Manual Rev. 4
Page 13
R
To return a product or request support:
If you live outside the U.S., United Kingdom, Ireland, or Mexico, contact your
follow their instructions on how to return Chauvet
Call the corresponding Chauvet Technical Support office and request a Return
product. Be prepared to
provide the model number, serial number, and a brief description of the cause for the
You must send the merchandise prepaid, in its original box, and with its original packing
Clearly label the package with the RMA number. Chauvet will refuse any product
number
the following information on a piece of paper
properly. Any shipping damage resulting from inadequate
reserves the right to use its own discretion to repair or replace returned
ETURNS
RMA
In the U.S., contact Chauvet World Headquarters (see Contact Us).
In the UK or Ireland, contact Chauvet Europe Ltd. (see Contact Us).
In Mexico, contact Chauvet Mexico (see Contact Us).
In any other country, DO NOT contact Chauvet. Contact your distributor. See
www.chauvetlighting.com
for distributors outside the U.S., United Kingdom, Ireland, or Mexico.
distributor of record and products to them. Visit our website for contact details.
Merchandise Authorization (RMA) number before shipping the return.
and accessories. Chauvet will not issue call tags.
returned without an RMA number.
Write the RMA number on a properly affixed label. DO NOT write the RMA directly on the box.
Before sending the product, clearly write and place it inside the box:
Your name
Your address
Your phone number
RMA number
A brief description of the problem
Be sure to pack the product packaging will be your responsibility. FedEx packing or double-boxing are recommended.
Chauvet product(s).
Hurricane™ 901 User Manual Rev. 4 Page 13 of 13
Page 14
C
WORLD HEADQUARTERS - Chauvet
General Information
Toll free: (800) 762-1084
Technical Support
World Wide Web www.chauvetlighting.com
UNITED KINGDOM AND IRELAND - Chauvet Europe Ltd.
General Information
Fax: +44 (0)1773 511110
Technical Support
MEXICO - Chauvet Mexico
General Information
Voice: +52 (728) 285-5000
Technical Support
Outside the U.S., United Kingdom, Ireland, or Mexico, contact your dealer. Follow their instructions to request support or to return a product. Visit our website for contact details.
ONTACT
US
Address: 5200 NW 108th Avenue Sunrise, FL 33351 Voice: (954) 577-4455 Fax: (954) 929-5560
Address: Unit 1C Brookhill Road Industrial Estate Pinxton, Nottingham, UK NG16 6NT Voice: +44 (0)1773 511115
Address: Av. Santa Ana 30 Parque In dustr i al Lerma Lerma, Mexico C.P. 52000
Voice: (954) 577-4455 (Press 4) Fax: (954) 756-8015 Email: tech@chauvetlighting.com
Email: uktech@chauvetlighting.com
World Wide Web www.chauvetlighting.co.uk
Email: servicio@chauvet.com.mx
World Wide Web www.chauvet.com.mx
Page 14 of 14 Hurricane™ 901 User Manual Rev. 4
Page 15
Dimensions and
Length
Width
Height
Weight
10.4 in (264 mm)
8.7 in (221 mm)
9.1 in (231 mm)
7.7 lb (3.5 kg)
Note: Dimensions in inches rounded to the nearest decimal digit.
Power
Power Supply Type
Range
Voltage Selection
120 V, 60 Hz
230 V, 50 Hz
Parameter
120 V, 60 Hz
230 V, 50 Hz
Consumption
670 W
670 W
Operating Current
5.6 A
2.9 A
Fuse
F 10 A, 250 V
F 10 A, 250 V
Power I/O
US/Worldwide
UK/Europe
Power input connector
IEC
IEC
Power Cord plug
Edison (US)
Local plug
Operation
Heat-up Time
Tank Capacity
1.5 min
1.3 liter
Remote Controllers
Remote Control
Cable Length
Included/Optional
FC-M
15 ft (462 cm)
Included
FC-T
15 ft (462 cm)
Optional
FC-W
N/A
Optional
Fog Production
Output
Fluid Consumption
Tank Capacity
4,000 cfm
11 ml/min
0.3 gal (1.3 l)
Thermal
Max. External Temperature
Cooling System
Indoor/Outdoor
104° F (40° C)
Convection
Indoor only
Ordering
Product
Product Name
Item Code
Item Number
Hurricane 901 (120 V)
09070324
H901
Hurricane 901 (230 V)
09070325
220VH901
Optional Remotes
Product Name
Item Code
Item Number
Fogger Timer Remote
05080150
FC-T
Fogger Wireless Remote
05080151
FC-W

6. TECHNICAL SPECIFICATIONS

Weight
Magnetic (internal)
or
Fixed
(per model)
Hurricane™ 901 User Manual Rev. 4 Page 15 of 15
Loading...