Chauvet DJ Hurricane 2000 Users Manual

User Manual
HURRICANE 2000
TABLE OF CONTENTS
1. Before You Begin ....................................................................... 1
What Is Included ........................................................................................... 1
Unpacking Instructions.................................................................................. 1
Claims ............................................................................................................................ 1
Text Conventions .......................................................................................... 1
Symbols ........................................................................................................ 1
Disclaimer ..................................................................................................... 1
Safety Notes.................................................................................................. 2
2. Introduction ................................................................................ 3
Product Overview.......................................................................................... 3
Product Dimensions ...................................................................................... 4
3. Setup ........................................................................................... 5
AC Power...................................................................................................... 5
Resetting the Breaker ................................................................................... 5
Mounting ....................................................................................................... 5
Orientation...................................................................................................................... 5
4. Operation .................................................................................... 7
Hurricane 2000 Control Priority..................................................................... 7
Control Panel Operation................................................................................ 7
Control Panel Description .............................................................................................. 7
Programming.................................................................................................................. 7
Operation ...................................................................................................... 8
Remote or Manual Operation......................................................................................... 8
Optional Wireless Remote (FC-W)................................................................................. 8
Menu Map ...................................................................................................................... 8
DMX Linking................................................................................................................... 8
Configuration (DMX) ..................................................................................... 8
Starting Address............................................................................................................. 9
DMX Values ................................................................................................................... 9
5. Maintenance and Storage.......................................................... 10
Fogger Maintenance ..................................................................................... 10
Storage.......................................................................................................... 10
6. Technical Specifications ........................................................... 11
Returns........................................................................................ 12
Contact Us .................................................................................. 13
Hurricane 2000 User Manual Rev. 1
BEFORE YOU BEGIN

1. BEFORE YOU BEGIN

What Is Included

Hurricane 2000
Power Cord

Unpacking Instructions

Carefully unpack the product immediately and check the container to make sure all the parts are in the package and are in good condition.

Claims

If the box or the contents (the product and included accessories) appear damaged from shipping, or show signs of mishandling, notify the carrier immediately, not Chauvet. Failure to report damage to the carrier immediately may invalidate your claim. In addition, keep the box and contents for inspection.
For other issues, such as missing components or parts, damage not related to shipping, or concealed damage, file a claim with Chauvet within 7 days of delivery.

Text Conventions

CONVENTION MEANING
1–512 A range of values
50/60 A set of values of which only one can be chosen
Settings A menu option not to be modified
<ENTER> A key to be pressed on the product’s control panel
ON A value to be entered or selected
Warranty Card
Quick Reference Guide

Symbols

SYMBOL MEANING
Electrical warning. Not following these instructions may cause electrical damage to the product, accessories, or the user.
Critical installation, configuration, or operation information. Not following these instructions may make the product not work, cause damage to the product, or cause harm to the operator.
Important installation or configuration information. The product may not function correctly if this information is not used.
Useful information.

Disclaimer

Chauvet believes that the information contained in this manual is accurate in all respects. However, Chauvet assumes no responsibility and specifically disclaims any and all liability to any party for any loss, damage or disruption caused by any errors or omissions in this document, whether such errors or omissions result from negligence, accident or any other cause. Chauvet reserves the right to revise the content of this document without any obligation to notify any person or company of such revision, however, Chauvet has no obligation to make, and does not commit to make, any such revisions. Download the latest version from www.chauvetdj.com
The works of authorship contained in this manual, including, but not limited to, all design, text and images are owned by Chauvet.
© Copyright 2018 Chauvet & Sons, LLC. All rights reserved.
Electronically published by Chauvet in the United States of America. CHAUVET, the Chauvet logo, and Hurricane 2000 are registered trademarks or trademarks of Chauvet &
Sons LLC (d/b/a Chauvet and Chauvet Lighting) in the United States and other countries. Other company and product names and logos referred to herein may be trademarks of their respective companies.
.
Hurricane 2000 User Manual Rev. 1
Page 1 of 11

Safety Notes

This product is not intended for permanent installation.
ONLY connect this product to a grounded and protected circuit.
Always disconnect from power before cleaning or resetting the breaker.
Make sure the power cord is not crimped or damaged.
Never disconnect this product from power by pulling on the cord.
DO NOT touch this product when it is operating because it may be hot.
Do not touch the output nozzle on this product. It is very hot during operation and it may remain hot for several hours after turning the unit off.
Depending on the amount of fog/haze generated, all fog machines may set off smoke detectors.
The voltage of the outlet to which you are connecting this product must be within the range stated on the decal or rear panel of the product.
Always mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
Be sure that no ventilation slots on the unit’s housing are blocked.
ONLY use the hanging/mounting bracket to carry this product.
The maximum ambient temperature is 104 °F (40 °C). Do not operate this product at higher temperatures.
In the event of a serious operating problem, stop using immediately.
DO NOT open this product. It contains no user-serviceable parts.
Do not use for space heating purposes.
Use only CHAUVET water-based fog fluid.
Drain the tank before transporting the product.
To eliminate wear and improve its lifespan, during periods of non-use completely disconnect from power via the main breaker or by unplugging it.
BEFORE YOU BEGIN
Keep this User Manual for future use. If you sell the product, be sure that the purchaser receives this document.
Page 2 of 11
Hurricane 2000 User Manual Rev. 1
INTRODUCTION
Fluid Tank
DMX In/Out
Power Switch
Power In
Menu Buttons
LED Display
Breaker
Remote Connection
Rubber Feet
for Floor
Mounting (x4)

2. INTRODUCTION

Product Overview

Hurricane 2000 User Manual Rev.1
Page 3 of 11

Product Dimensions

11.7 in
296.5 mm
19 in
485 mm
11 in
277 mm
INTRODUCTION
Page 4 of 11
Hurricane 2000 User Manual Rev.1
SETUP

3. SETUP

AC Power

The Hurricane 2000 has a auto-ranging voltage power supply and it can work with an input voltage of either 120 VAC, 60 Hz or 230 VAC, 50 Hz, depending on the specific model.
To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the current value listed on the label affixed to the product’s back panel, or refer to the product’s specifications chart. The listed current rating indicates the product’s average current draw under normal conditions.
Always connect the product to a protected circuit (a circuit breaker or fuse). Make sure the product has an appropriate electrical ground to avo id the risk of electrocution or fire.
To eliminate unnecessary wear and improve its lifespan, during periods of non­use completely disconnect the product from power via breaker or by unplugging it.
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel serves only as a 0 to 100% switch.

Resetting the Breaker

This product is equipped with a resettable circuit breaker. If the breaker trips, all sections of this product will lose power.
1. Remove the power cord from mains power.
2. Allow unit to cool for 15 minutes.
3. After 15 minutes, you may attempt to reset the breaker by pressing the button with your finger.
4. Plug the product’s power cord into the power outlet and continue using as recommended.
Disconnect the product from the power outlet before resetting the breaker.

Mounting

Before mounting the product, read and follow the safety recommendations indicated in the Safety Notes.

Orientation

This product may NOT be tilted. This product should be level when on a surface or when mounted.

Rigging

Before deciding on a location, always make sure there is easy access to the product for maintenance and fluid replenishment.
Make sure adequate ventilation is provided around the product.
Make sure that the structure or surface onto which you are mounting the product can support the product’s weight. (see the Technical Specifications
When mounting the product overhead, always use a safety cable. Mount the product securely to a rigging point, such as an elevated platform or a truss.
When rigging the product onto a truss, you should use a mounting clamp of appropriate weight capacity. The bracket has 13-mm holes, which are appropriate for this purpose.
The rubber feet also serve as floor supports and allow for surface mounting. When mounting the product on the floor, make sure that the product and cables are away from people and vehicles.
)
Hurricane 2000 User Manual Rev. 1
Page 5 of 11
Mounting Diagram
Mounting Clamp
Rubber Feet for
Surface Mounting
(x4)
Safety Cable
Mounting Bracket
Safety Loop
Bracket Adjustment
Knob (2x)
SETUP
Page 6 of 11
This product may NOT be tilted. This product should be level when on a surface.
While operating the Hurricane 2000, make sure there is adequate fog fluid in the machine to prevent pump and heater damage. When the fog fluid level becomes low, simply add more fog fluid to continue using the Hurricane 2000.
FCQ (Fog Cleaner Quart) was specifically developed by Chauvet to clean your Hurricane 2000. Make sure you use FCQ regularly, no longer than 90 days between cleanings, to increase the life of your product.
Hurricane 2000 User Manual Rev. 1
OPERATION

4. OPERATION

Hurricane 2000 Control Priority

The Hurricane 2000 operates according to the following priority control levels:

Control Panel Operation

To access the control panel functions, use the four buttons located underneath the display, and the two manual control knobs located to the right of the display. Please refer to the Product Overview button and knob locations on the control panel.

Control Panel Description

BUTTON FUNCTION
<FUNCTION> Enters the programming mode
<UP>
<DOWN>
<TIMER> Starts the timer controlled operation
< VOLUME> Controls the volume of the fog output, from 1-100%
<MANUAL> Manual fog output
Navigates upwards through the menu list and increases the numeric value when in a function
Navigates downwards through the menu list and decreases the numeric value when in a function

Programming

Refer to the Menu Map to understand the menu options. The menu map shows the main level and a variable number of programming levels for each option.
To go to the desired main level, press <FUNCTION> repeatedly until the option shows on the display. This will take you to the first programming level for that option.
To select an option or value within the current programming level, press <UP> or <DOWN> until the option shows on the display. If there is another programming level, you will see that first option, or you will see the selected value.
•Press <FUNCTION> repeatedly to exit to the previous main level.
to see the
Hurricane 2000 User Manual Rev. 2
Page 7 of 11
OPERATION

Operation

Remote or Manual Operation

The Hurricane 2000 can be operated manually, or with a wireless remote (FC-W). The Manual button is located on the rear of the unit. See the product Overview. Details on the optional controllers are available at http://www.chauvetlighting.com/.

Optional Wireless Remote (FC-W)

The optional FC-W wireless remote allows the user to trigger the Hurricane 2000 to produce fog from up to 100 ft away. Plug the fog machine into power and turn the product’s power switch on.
1. Plug in the fog machine to power.
2. Plug the FC-W wireless remote receiver into the Wireless Remote Connector on the back of the
Hurricane 2000. (See the product Overview.)
3. Allow the Hurricane 2000 3 minutes to heat up. (See Fluid Tank Indicator Lights.)
4. Press and hold the <1>, <2>, <3>, or <4> button on the wireless remote. (Download the FC-W
User Manual from www.chauvetlighting.com
5. Release the button to stop the fog output.
for more information on addressing the FC-W)
Ensure the FC-W has an unobstructed view of the receiver for maximum performance.
The <2>, <3>, and <4> buttons are reserved for future use.

Menu Map

MODE PROGRAMMING LEVELS DESCRIPTION
Interval Set 1-200s Sets the interval between fog output
Duration Set 1-200s Sets the duration of the fog output
Timer Out 1-100% Sets the timer
Volume Out 1-100% Sets the fog volume
DMX Address 1-512 Selects the DMX starting address
Fluid Sensor
ON
OFF
Turns the fluid sensor on/off

DMX Linking

The Hurricane 2000 can work with a DMX controller. Instructions for connecting and configuring this product for DMX operation are in the User Manual. If you are not familiar with DMX, download the DMX Primer from www.chauvetdj.com
.
Starting Address
To ensure full access to all channels available in DMX mode, the highest recommended DMX address is
512.

Configuration (DMX)

The Hurricane 2000 works with a DMX controller. Information about DMX is in the CHAUVET DMX Primer, which is available from the Chauvet website http://www.chauvetlighting.com/downloads/
DMX_Primer_rev05_WO.pdf.
Page 8 of 11
Hurricane 2000 User Manual Rev. 2
OPERATION

Starting Address

When selecting a starting DMX address, always consider the number of DMX channels the selected DMX mode uses. If you choose a starting address that is too high, you could restrict the access to some of the product’s channels.
The Hurricane 2000 uses 1 DMX channels, which defines the highest configurable address to 512. If you are not familiar with the DMX protocol, download the DMX Primer from www.chauvetdj.com To select the starting address, do the following:
1. Press <MENU> repeatedly until DMX Add shows on the display.
2. Use <UP> or <DOWN> to select the starting address.
3. Press <ENTER>.

DMX Values

CHANNEL FUNCTION VALUE PERCENT/SETTING
005 No function
1 Fog Output
000
006
255 Fog volume, low to high
.
Hurricane 2000 User Manual Rev. 2
Page 9 of 11
MAINTENANCE AND STORAGE

5. MAINTENANCE AND STORAGE

Fogger Maintenance

Do not allow the fogger to become clogged. After every 40 hours of continuous operation, use CHAUVET Fog Cleaner Quart (FCQ) through the system to prevent the accumulation of particulate matter in the heating element.
The recommended cleaning procedure is as follows.
1. Unplug the product from power.
2. Empty all fog fluid from the machine.
3. Add cleaning solution to the tank.
4. Connect the product to power and allow it to warm up.
5. Run the unit in a well-ventilated area until the tank is almost empty. Do not allow the pump to run dry.
6. Refill with fog fluid to continue using the Fogger. Run the machine briefly to clear any remaining cleaning solution from the pump and heater.
Do Not operate the machine without fluid at any time.
Fog Cleaner Quart (FCQ) was specifically developed by Chauvet to clean your Hurricane 2000. Make sure you use FCQ regularly, no longer than 90 days between cleanings, to increase the life of your product.

Storage

Before storing the fogger, run FCQ through the system as described in the cleaning procedure above; however, only follow steps 1 through 5. Do not refill the tank with fog fluid if storing the fogger. Cleaning the system prior to storage will help prevent any particles from condensing inside the pump or
heater while not in use.
Test-run your Hurricane 2000 on a monthly basis to achieve the best performance.
Powering off the unit for transport
Follow these instructions to prevent leaks, and allow the air pump to entirely clear the fluid line and heater of the fog fluid before power off.
To prevent spills or leaks before, during, or after transport, Chauvet recommends the following steps for your Hurricane 2000:
1. Turn the "Fog Volume" output to off.
2. Wait 30-45 seconds.
3. When there is no more fog fluid in the output line, turn off the machine by pressing the power switch.
Page 10 of 11
Hurricane 2000 User Manual Rev. 1
TECHNICAL

6. TECHNICAL SPECIFICATIONS

Dimensions and Weight
LENGTH WIDTH HEIGHT WEIGHT
19 in (485 mm) 11.7 in (296 mm) 11 in (277 mm) 13.6 lb (6.2 kg)
Note: Dimensions in inches rounded to the nearest decimal digit.
Power
POWER SUPPLY TYPE RANGE VOLTAGE SELECTION
Model-specific
PARAMETER 120 V, 60 HZ 230 V, 50 HZ
Consumption 1230 W 1350 W
Operating Current 10.3 A 6 A
Breaker 15 A, 250 V 15 A, 250 V
POWER I/O U.S./WORLDWIDE UK/EUROPE
Power input connector IEC IEC
Power Cord plug Edison (U.S.) Local Plug
Operation
HEAT-UP TIME TANK CAPACITY FLUID CONSUMPTION
3 min 1 gal (3 l) 48.6 ml/min
120 VAC, 60 Hz, or 230 VAC, 50 Hz
Fixed
Fog Output
OUTPUT
20,000 cfm
Thermal
MAXIMUM EXTERNAL TEMPERATURE COOLING SYSTEM
104 °F (40 °C) Convection
DMX
I/O CONNECTOR CHANNEL RANGE
3-pin or 5-pin XLR 1
Ordering
PRODUCT NAME ITEM CODE UPC NUMBER
Hurricane 2000 (120 V) 05071448 781462217969 Hurricane 2000 (230 V) 05071449 781462217976
Hurricane 2000 User Manual Rev. 1
Page 11 of 11

RETURNS

RETURNS
In case you need to get support or return a product:
If you are located in the U.S., contact Chauvet World Headquarters.
If you are located in the UK or Ireland, contact Chauvet Europe Ltd.
If you are located in Benelux, contact Chauvet Europe BVBA.
If you are located in France, contact Chauvet France.
If you are located in Germany, contact Chauvet Germany.
If you are located in Mexico, contact Chauvet Mexico.
If you are located in any other country, DO NOT contact Chauvet. Instead, contact your local distributor. See www.chauvetdj.com Germany, or Mexico.
If you are located outside the U.S., UK, Ireland, Benelux, France, Germany, or Mexico, contact your distributor of record and follow their instructions on how to return Chauvet products to them. Visit our website www.chauvetdj.com
Call the corresponding Chauvet Technical Support office and request a Return Merchandise Authorization (RMA) number before shipping the product. Be prepared to provide the model number, serial number, and a brief description of the cause for the return.
Send the merchandise prepaid, in its original box, and with its original packing and accessories. Chauvet will not issue call tags.
Clearly label the package with the RMA number. Chauvet will refuse any product returned without an RMA number.
Write the RMA number on a properly affixed label. DO NOT write the RMA number directly on the box.
for distributors outside the U.S., UK, Ireland, Benelux, France,
for contact details.
Before sending the product, clearly write the following information on a piece of paper and place it inside the box:
Your name
Your address
Your phone number
•RMA number
A brief description of the problem
Be sure to pack the product properly. Any shipping damage resulting from inadequate packaging will be your responsibility. FedEx packing or double-boxing are recommended.
Chauvet reserves the right to use its own discretion to repair or replace returned product(s).
Page 12 of 11
Hurricane 2000 User Manual Rev. 1

CONTACT US

CONTACT US
General Information Technical Support
World Headquarters
UK
Benelux
France
Germany
Mexico
Address: Av. de las Partidas 34 - 3B
Lerma, Edo. de México, CP 52000
Address: 5200 NW 108th Ave. Voice: (844) 393-7575
Sunrise, FL 33351 Fax: (954) 756-8015
Voice: (954) 577-4455 Email: chauvetcs@chauvetlighting.com
Fax: (954) 929-5560
Toll Free: (800) 762-1084 Website: www.chauvetdj.com
Address: Unit 1C Email: UKtech@chauvetlighting.eu
Brookhill Road Industrial Estate
Pinxton, Nottingham, UK Website: www.chauvetdj.eu
NG16 6NT
Voice: + 44 (0) 17 73 511115
Fax : +44 (0) 1773 511110
Address: Stokstraat 18 Email: BNLtech@chauvetlighting.eu
9770 Kruishoutem
Belgium Website: www.chauvetdj.eu
Voice: +32 9 388 93 97
Address: 3, Rue Ampère
91380 Chilly-Mazarin
France Website: www.chauvetdj.eu
Voice: +33 1 78 85 33 59
Address: Bruno-Bürgel-Str. 11
28759 Bremen
Germany Website: www.chauvetdj.eu
Voice: +49 421 62 60 20
(Entrance by Calle 2)
Zona Industrial Lerma Website: www.chauvetdj.mx
Voice: +52 (728) 690-2010
Email: FRtech@chauvetlighting.fr
Email: DEtech@chauvetlighting.de
Email: servicio@chauvet.com.mx
Outside the U.S., U.K., Ireland, France, Germany, Benelux, or Mexico, contact the dealer of record. Fol­low the instructions to request support or to return a product. Visit our website for contact details.
Hurricane 2000 User Manual Rev. 1
Page 13 of 11
Loading...