Chauvet DJ Hurricane 1800 Flex Users Manual

Page 1
User Manual
Page 2
TABLE OF CONTENTS
What Is Included ............................................................................................................................... 3
Unpacking Instructions ..................................................................................................................... 3
Claims ....................................................................................................................................................... 3
Text Conventions ............................................................................................................................. 3
Symbols ............................................................................................................................................ 3
Disclaimer ......................................................................................................................................... 3
Product at a Glance .......................................................................................................................... 4
Safety Notes ..................................................................................................................................... 4
2. Introduction ................................................................................................................... 5
Overview ........................................................................................................................................... 5
Dimensions ....................................................................................................................................... 6
AC Power ......................................................................................................................................... 7
Resetting the Breaker ................................................................................................................................ 7
Mounting ........................................................................................................................................... 8
Orientation ................................................................................................................................................. 8
Rigging ...................................................................................................................................................... 8
Remote or Manual Operation ........................................................................................................... 9
Timer Remote Controller (FC-T) ............................................................................................................... 9
Fluid Tank Indicator LED .................................................................................................................. 9
Auto Cut-Off Feature ...................................................................................................................... 10
DMX Operation ............................................................................................................................... 10
Setting the Starting Address .................................................................................................................... 10
DMX Channel Values .............................................................................................................................. 10
DMX Quick Reference Chart ................................................................................................................... 11
5. Technical Information ..................................................................................................12
Fogger Maintenance ...................................................................................................................... 12
Storage ........................................................................................................................................... 12
6. General Troubleshooting .............................................................................................13
7. Technical Specifications ..............................................................................................14
Returns .............................................................................................................................15
Contact Us ........................................................................................................................16
Page 2 of 16 Hurricane™ 1800 Flex User Manual Rev. 8
Page 3
What Is

Unpacking
Instructions

Text
1—512
A range of values
50/60
A set of values
Settings
A menu option
Menu > Settings
A sequence of menu options
<Enter>
A button

Symbols

Critical installation, configuration, or operation information. Not damage to the product, or cause harm to the operator.

Disclaimer

1. BEFORE YOU BEGIN

Included

Claims

Conventions
Hurricane™ 1800 Flex
FC-T Wired Timer Controller
Hanging Bracket with Mounting
Hardware
Carefully unpack the product immediately and check the container to make sure all the parts are in the package and are in good condition.
If the box or the contents (the product and included accessories) appear damaged from shipping, or show signs of mishandling, notify the carrier immediately, not Chauvet. Failure to report damage to the carrier immediately may invalidate your claim. In addition, keep the box and contents for inspection.
For other issues, such as missing components or parts, damage not related to shipping, or concealed damage, file a claim with Chauvet within 7 days of delivery.
Convention Meaning
Symbol Meaning
Power Cord
Warranty Card
Quick Reference Guide
The information and specifications contained in this User Manual are subject to change without notice. Chauvet assumes no responsibility or liability for any errors or omissions, and reserves the right to revise or recreate this manual at any time. Download the latest version from www.chauvetlighting.com.
© Copyright 2015 Chauvet. All rights reserved.
Electronically published by Chauvet in the United States of America.
Author Date Editor Date
R. Isenstadt 4/15/2015 D. Couppe 5/12/2015
following these instructions may make the product not work, cause
Important installation or configuration information. The product may not function correctly if this information is not used.
Useful information.
HurricaneTM 1800 Flex User Manual Rev. 8 Page 3 of 16
Page 4
Product at a
x
x
x
P
x
x
P
x
x
x

Safety Notes

Do not add perfume, alcohol, gasoline, or any other flammables to the fog fluid.
completely disconnect the product from power via breaker or by unplugging it.
sell the product to another user, be sure to
FCQ (Fog Cleaner Quart) was specifically developed by Chauvet to clean your
, no longer than 90 days
between cleanings, to increase the life of your fogger.
Glance
Use on Dimmer Outdoor Use Sound-Activated DMX Master/Slave
These notes include important information about the mounting, usage, and maintenance of this product; read before using the product.
Always connect the product to a grounded circuit to avoid the risk of electrocution.
Always disconnect the product from the power source before cleaning or resetting
the breaker.
Make sure the power cord is not crimped or damaged.
Never disconnect the product from power by pulling or tugging on the cord.
If mounting the product overhead, always secure to a fastening device using a
safety cable.
Make sure there are no flammable materials close to the product when operating.
Do not touch the product’s housing when operating because it may be very hot.
Do not mount the product on a flammable surface (linoleum, carpet, wood, paper,
carton, plastic, etc.).
The product’s nozzle is very hot during operation and it remains hot for a long time after operation has stopped.
The fog exits the nozzle at a very high temperature. Keep a minimum distance of
6.5 ft (2 m) from the nozzle to the nearest object.
Do not use the product as a space heater .
Do not drink or come in contact with the fog fluid. If you do, call your local
emergency service (911 in the US) for help.
Auto Programs Fixed voltage (120 V or 230 V) Replaceable Fuse User-Serviceable Duty Cycle
Always make sure that the voltage of the outlet to which y ou are conne cti ng the product is within the range stated on the decal or rear panel of the product.
The product is for indoor use only! (IP20) To prevent risk of fire or shock, do not expose the product to rain or moisture.
Always install the product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
Be sure that no ventilation slots on the product’s housing are blocked.
Never connect the product to a dimmer.
Never carry the product from the power cord or any moving part. Always use the
hanging/mounting bracket.
The maximum ambient temperature (Ta) is 104 °F (40 °C). Do not operate the product at higher temperatures.
In the event of a serious operating problem, stop using the product immediately.
Never try to repair the product. Repairs carried out by unskilled people can lead to
damage or malfunction. Contact the nearest authorized technical assistance center.
This product is not intended for permanent installation.
Use only CHAUVET® water-based fog fluid.
Drain the tank before transporting or storing the product.
To eliminate unnecessary wear and improve its lifespan, during periods of non-use
Keep this User Manual for future use. If you give this document to the next owner.
Hurricane™ 1800 Flex. Make sure you use FCQ regularly
Page 4 of 16 Hurricane™ 1800 Flex User Manual Rev. 8
Page 5

2. INTRODUCTION

Overview

Fog Fluid
Tank
DIP Switch
3-Pin DMX
In/Out
Manual-Fog Button
Remote Control
Input
5-Pin DMX
In/Out
Breaker
Power Cable
Output Nozzle
Back Panel View
Front View
Power Switch
Mounting Bracket
Adjustment Knobs x4
HurricaneTM 1800 Flex User Manual Rev. 8 Page 5 of 16
Page 6

Dimensions

22.2 in
563 mm
15 in
380 mm
13.4 in
340 mm
Page 6 of 16 Hurricane™ 1800 Flex User Manual Rev. 8
Page 7

AC Power

Resetting the

3. SETUP

This HurricaneTM 1800 Flex has a fixed voltage power supply and it can work with an input voltage of either 120 VAC, 60 Hz or 230 VAC, 50 Hz, depending on the specific model.
To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the current value listed on the label affixed to the product’s back panel, or refer to the product’s specifications chart. The listed current rating indicates the product’s average current draw under normal conditions.
Always connect the product to a protected circuit (circuit breaker or fuse). Make
sure the product has an appropriate electrical ground to avoid the risk of electrocution or fire.
To eliminate unnecessary wear and improve its lifespan, during periods of non-
use completely disconnect the product from power via breaker or by unplugging it.
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel serves only as a 0 to 100% switch.
1. Disconnect the product from power.
Breaker
2. Allow to cool for 5-15 minutes.
3. Using your hand, press on the button for the breaker, until it remains in place.
Disconnect the product from power before resetting the breaker.
The breaker will not reset until it has been allowed to cool.
HurricaneTM 1800 Flex User Manual Rev. 8 Page 7 of 16
Page 8
Hanging Clamp
NOTE!
SEPARATELY.

Mounting

While oper ating the Hurri cane™ 1800 Flex, make sure t here is adequa te fog fluid i n the
Pointing up
Pointing
Safety Cable
Before mounting the product, read and follow the safety recommendations indicated in the
Safety Notes.

Orientation

This product may be mounted in a 90° degree angle (horizontal), provided there is adequate room for ventilation. The tank of the product should not move from this position. However, the front portion of the fog machine can tilt up and down in the desired direction. This is secured by using the bracket adjustment knobs.

Rigging

Before deciding on a location, always make sure there is easy access to the product for maintenance and fluid replenishment.
Make sure that the structure or surface onto which you are mounting the product can support the product’s weight (see the Technical Specifications).
When mounting the product overhead, always use a safety cable. Mount the product securely to a rigging point, such as an elevated platform or a truss.
When rigging the product onto a truss, you should use a mounting clamp of appropriate weight capacity. The bracket has 13-mm holes, which are appropriate for this purpose.
The rubber feet also serve as floor supports and allow for surface mounting. When mounting the product on the floor, make sure that the product and cables are away from people and vehicles.
Mounting Diagram
CLAMP AND SAFETY CABLE SOLD
machine to prevent pump and heat e r damage. When fluid runs low, the auto cut-off feat ure will activate. Simply add more fog fluid to continue using the Hurric ane™ 1800 Flex.
Page 8 of 16 Hurricane™ 1800 Flex User Manual Rev. 8
Page 9
Remote or
Manual
Controller
1. Plug in the fog machine to power and turn the power switch to the product on.
Fluid Tank
Duration
Interval
Adjustment
Timer LED
Manual
Manual/Power
LED
Manual Control Continuous
Timer On/Off

4. OPERATION

Operation
Timer Remote
(FC-T)
The Hurricane™ 1800 Flex can be operated manually, or with the included timer remote controller (FC-T). T he Manual button is located on the rear of the unit. See the product
Overview.
Two other optional remote controls are also available: a manual wired remote (FC-M) and a wireless remote (FC-W). Details on the optional controllers are available at
http://www.chauvetlighting.com/.
The FC-T wired timer controller allows you to automatically trigger fog output by setting interval and duration times. LED indicator lights display the machine and controller’s current state. Rotary knobs set interval and duration times, while manual and continuous buttons allow overriding control.
2. Plug in the timer controller to the Manual Controller socket on the back of the fog machine.
3. Press the <TIMER ON/OFF> latching button on the timer controller. The Timer LED Indicator above the button will light up. The <TIMER ON/OFF> latching button will remain on until it is pressed again.
4. Set the INTERVAL and DURATION adjustment knobs to the desired positions.
INTERVAL knob sets the amount of time in between bursts of fog
DURATION knob sets the length of time that the fog machine will run during the burst
5. Press the <CONTINUOUS> latching button and the fog machine outputs fog until the button is pressed again. The Manual/Power LED Indicator above the button will light up during continuous operation.
Note: The duration of continuous fog output is based on the capability of the fog machine.
6. Press the <MANUAL> button to momentarily output fog. The fog machine will output fog for as long as you hold down the button. During manual operation the Manual Momentary LED Indicator above the button will light up.
Note: The duration of manual fog output is based on the capability of the fog machine.
Indicator
Adjustment
Momentary LED
Momentary Button
Latching Button
The indicator LED inside of the Hurricane™ 1800 Flex shows the status of the fogger by
Indicator LED
HurricaneTM 1800 Flex User Manual Rev. 8 Page 9 of 16
causing the fluid tank to glow as follows:
Red - T he product is heating up, or will heat up once the trigger is released.
Blue - Optimum temperature has been reached. Ready to produce fog.
Flashing (any color) - Fluid level is low.
Latching Button
Page 10
Auto Cut-Off
DMX
Determine the largest value switch that is less than the remainder from the previous
EXAMPLE STARTING ADDRESS
Address 10
Resolving address
233 – (128) = 105, Turn ON Dip # 8
DIP SWITCH
(DMX VALUE)
1
9
1
256
DMX Channel
Channel
Function
Value
Percent/Setting
This product has an auto cut-off safety feature to keep the machine from becoming damaged. This is referring to the operation of the pump. When the fluid tank is empty, the pump will still
Feature
operate for a short period of time, until all of the fluid has been removed from the system. Then, it will sense that there is no fluid, and will automatically stop the fog output. An indication that this has occurred is when the LED’s that are lighting the fluid tank are flashing.
This feature takes approximately 30 seconds to 1 minute to engage once the fluid
has emptied from the tank.
In order for the fog machine to automatically reset, the trigger must be released
either from the wired remote, wireless remote, the manual fog button on the unit, or via a DMX controller. If the DMX controller is used, the DMX channel must be brought to a value of 000 (0%) in order to allow the fog machine to reset itself.
Once the tank has been refilled with fog fluid, you may resume using the fog
machine. The auto cut-off will automatically reset.
Connecting a DMX controller to the Hurricane™ 1800 Flex automatically sets the product to DMX mode. There are both 3-pin and 5-pin inputs and outputs on the rear panel. For more
Operation
information on DMX, download the DMX Primer from Chauvet.
Setting the
Starting
Address
The starting address on the Hurricane™ 1800 Flex is set by using the DIP switch on the rear panel, with a binary version of the address desired. If unfamiliar with binary numbering systems, see the DMX Quick Reference Chart, or follow the instructions below to determine how to set the address:
1. Determine the largest value switch that is less than the start address. Turn this switch on.
2. Subtract the value of the switch you just turned on from the starting address number.
3. subtraction. Turn this switch on.
4. Subtract the value of the switch you just turned on from the remainder of the previous subtraction.
5. Repeat steps three and four until you have a remainder of zero.
Switch # 4 = 8 Switch # 2 = 2 Total = 10
Page 10 of 16 Hurricane™ 1800 Flex User Manual Rev. 8
Values
using simple math.
Address 233
1 Fog Output
105 – (64) = 41, Turn ON Dip # 7 41 – (32) = 9, Turn ON Dip # 6 9 – (8) = 1, Turn ON Dip # 4 1 – (1) = 0, Turn ON Dip # 1
000ó005 006ó255
No function Fog output On/Off
2
2
3
4
4
8
5
16
6
32
7
64
8
128
Page 11
DIP Switch Position
DMX DIP
SWITCH SET
0=OFF
#8 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1
1=ON
#7 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1
X=OFF or ON
#6 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1
#1
#2
#3
#4
#5 0 0 0 0 0
32
64
96
128
160
192
224
256
288
320
352
384
416
448
480 1 0 0 0 0 1 33
65
97
129
161
193
225
257
289
321
353
385
417
449
481 0 1 0 0 0 2 34
66
98
130
162
194
226
258
290
322
354
386
418
450
482 1 1 0 0 0 3 35
67
99
131
163
195
227
259
291
323
355
387
419
451
483 0 0 1 0 0 4 36
68
100
132
164
196
228
260
292
324
356
388
420
452
484 1 0 1 0 0 5 37
69
101
133
165
197
229
261
293
325
357
389
421
453
485 0 1 1 0 0 6 38
70
102
134
166
198
230
262
294
326
358
390
422
454
486 1 1 1 0 0 7 39
71
103
135
167
199
231
263
295
327
359
391
423
455
487 0 0 0 1 0 8 40
72
104
136
168
200
232
264
296
328
360
392
424
456
488 1 0 0 1 0 9 41
73
105
137
169
201
233
265
297
329
361
393
425
457
489 0 1 0 1 0
10
42
74
106
138
170
202
234
266
298
330
362
394
426
458
490 1 1 0 1 0
11
43
75
107
139
171
203
235
267
299
331
363
395
427
459
491 0 0 1 1 0
12
44
76
108
140
172
204
236
268
300
332
364
396
428
460
492
1 0 1 1 0 13
45
77
109
141
173
205
237
269
301
333
365
397
429
461
493
0 1 1 1 0 14
46
78
110
142
174
206
238
270
302
334
366
398
430
462
494 1 1 1 1 0
15
47
79
111
143
175
207
239
271
303
335
367
399
431
463
495 0 0 0 0 1
16
48
80
112
144
176
208
240
272
304
336
368
400
432
464
496 1 0 0 0 1
17
49
81
113
145
177
209
241
273
305
337
369
401
433
465
497 0 1 0 0 1
18
50
82
114
146
178
210
242
274
306
338
370
402
434
466
498 1 1 0 0 1
19
51
83
115
147
179
211
243
275
307
339
371
403
435
467
499 0 0 1 0 1
20
52
84
116
148
180
212
244
276
308
340
372
404
436
468
500 1 0 1 0 1
21
53
85
117
149
181
213
245
277
309
341
373
405
437
469
501 0 1 1 0
1 22
54
86
118
150
182
214
246
278
310
342
374
406
438
470
502 1 1 1 0 1 23
55
87
119
151
183
215
247
279
311
343
375
407
439
471
503 0 0 0 1 1 24
56
88
120
152
184
216
248
280
312
344
376
408
440
472
504 1 0 0 1 1 25
57
89
121
153
185
217
249
281
313
345
377
409
441
473
505 0 1 0 1 1 26
58
90
122
154
186
218
250
282
314
346
378
410
442
474
506 1 1 0 1 1 27
59
91
123
155
187
219
251
283
315
347
379
411
443
475
507 0 0 1 1 1 28
60
92
124
156
188
220
252
284
316
348
380
412
444
476
508 1 0 1 1 1 29
61
93
125
157
189
221
253
285
317
349
381
413
445
477
509 0 1 1 1 1 30
62
94
126
158
190
222
254
286
318
350
382
414
446
478
510 1 1 1 1 1
31
63
95
127
159
191
223
255
287
319
351
383
415
447
479
511
DIP Switch Position DMX Address

DMX Quick Reference Chart

#9 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1
DMX Address Quick Reference Chart
HurricaneTM 1800 Flex User Manual Rev. 8 Page 11 of 16
Page 12
Fogger
between cleanings, to increase the life of your product.

Storage

5. TECHNICAL INFORMATION

Do not allow the fogger to become clogged. After every 40 hours of continuous operation,
Maintenance
use CHAUVET® Fog Cleaner Quart (FCQ) through the system to prevent the accumulation of particulate matter in the heating element.
The recommended cleaning procedure is as follows.
1. Unplug the product from power.
2. Empty all fog fluid from the machine.
3. Add cleaning solution to the tank.
4. Connect the product to power and allow it to warm up.
5. Run the unit in a well-venti late d area until the ta nk is almost empty . Do not allow the pump to run dry.
6. Refill with fogger fluid to continue using the fogger. Run the machine briefly to clear any remaining cleaning solution from the pump and heater.
Do Not operate the machine without fluid at any time.
Fog Cleaner Quart (FCQ) was specifically developed by Chauvet to clean your Hurricane™ 1800 Flex. Make sure you use FCQ regularly, no longer than 90 days
Before storing the fogger, run FCQ through the system as described in the cleaning procedure above; however, only follow steps 1 through 5. Do not refill the tank with fog fluid if storing the fogger. Cleaning the system prior to storage will help prevent any
particles from condensing inside the pump or heater while not in use
Test-run your Hurricane™ 1800 Flex on a monthly basis to achieve the best performance.
.
Page 12 of 16 Hurricane™ 1800 Flex User Manual Rev. 8
Page 13
Allow the product to warm up completely. This should take less than 10 minutes.
Allow the product to warm up completely.
Turn fog machine 45° to flatten out the bubble and allow the fog fluid to flow properly
Clean thoroughly with CHAUVET® FCQ. For full instructions, see Fogger
Maintenance. Refill with CHAUVET® water-based haze fluid.
Blocked pipes
Contact Customer Service
Failing part
Contact Customer Service
Maintenance. Refill with CHAUVET® water-based haze fluid.
Blocked pipes
Contact Customer Service
Failing part
Contact Customer Service
Clean thoroughly with CHAUVET® FCQ. For full instructions, see Fogger
Maintenance. Refill with CHAUVET® water-based haze fluid.
Blocked pipes
Contact Customer Service
Failing part
Contact Customer Service
Normal
Blue
Normal
Normal function
Make sure that the total load does not exceed the recommended Short circuit along the power lines
Check the power lines and power cords
No energy on power outlet
Check power outlet. Change to another outlet
Loose or damaged power cord
Check the power cord
Internal problem
Send product for repair
Wrong starting address on the product
DMX controller
Loose or damaged DMX cable
Check the DMX cable entering the faulty unit
Internal problem
Send product for repair
Signal cables are not DMX compatible
signals
Use a shorter DMX cable or install an optically coupled DMX amplifier right before the product with intermittent problems
Terminator not connected
Install a terminator
Fill the tank. Allow the unit to reach the normal operating temperature
blue tank indicator light stops flashing.
Fill the tank. While the unit is operating; remove but do not disconnect the fluid tank and tilt the machine at a 45° angle.
Empty fluid tank
Refill tank with the correct CHAUVET® water-based haze fluid

6. GENERAL TROUBLESHOOTING

Symptom Indicator Status Possible Cause Possible Action
Red Heater warming up
No output or short output
Spitting fluid
Circuit breaker or fuse keeps blowing
Product does not power up
Red flashing Air bubble in fluid line
Incorrect fluid
Blue
Incorrect fluid
Blue blinking
Incorrect fluid
Blue
Excessive load on the circuit
N/A
Turn off the product for 5 seconds, and then turn it back on. Repeat as necessary. Note: After more than 10 attempts, contact Customer Service.
Clean thoroughly with CHAUVET® FCQ. For full instructions, see Fogger
capacity of the breaker or fus e’s nom i n al cu rr ent
Set the correct starting address on the product
Product does not respond to DMX
Intermittent DMX Problems
False Sensor Reading (Priming)
Blue
LED Flashing
Wrong polarity setting on the
Interference with AC or radio
DMX cable too long
Air bubbles in fluid line
Change the signal polarity on the controller
Replace non-DMX cables with true DMX cables
Keep DMX cables away from AC wires or radio equipment
and for the blue indicator to light. Set the output to the highest level. Power cycle the unit 1-2 times until the fluid reaches the sensor. The
Fill the tank. While the unit is operating, pinch the fluid line between yo u r thumb and forefinger, and hold for 3 to 5 seconds creating a vacuum in the system. Release the pinched portion and allow the fluid to flow naturally.
If you still experience problems after trying the solutions presented here, contact Chauvet Technical Support.
HurricaneTM 1800 Flex User Manual Rev. 8 Page 13 of 16
Page 14
Dimensions and
22.2 in (563 mm)
13.4 in (340 mm)
15 in (380 mm)
27.6 lb (12.5 kg)
Note: Dimensions in inches rounded to the nearest decimal digit.
Power
120 VAC, 60 Hz or
230 VAC, 50 Hz
Consumption
1,364 W
1,300 W
Operating current
11.9 A
5.7 A
Breaker size
15 A
15
Power input connector
Hard-wired
Hard-wired
Power Cord plug
Edison (US)
Local plug
Operation
5 min
1.3 gal (5 l)
150 ml/min
Fog Output
25,000 cfm
Thermal
104 °F (40 °C)
Convection
Ordering
HurricaneTM 1800 Flex (120 V)
05070160
781462202965
HurricaneTM 1800 Flex (230 V)
05070320
781462206727

7. TECHNICAL SPECIFICATIONS

Weight
Length Width Height Weight
Power Supply Type Range Voltage Selection
Model-specific
Parameter 120 V, 60 Hz 230 V, 50 Hz
Power I/O US/Worldwide UK/Europe
Heat-up Time Tank Capacity Fluid Consumption
Output
Maximum External Temp. Cooling System
Fixed
Product Name Item Code Item Number
Page 14 of 16 Hurricane™ 1800 Flex User Manual Rev. 8
Page 15
R
In case you need to get support or return a product:
If you are located outside the U.S., UK, Ireland, Mexico, or Benelux, contact your to them. Visit our website www.chauvetlighting.com for contact details.
Call the corresponding Chauvet Technical Support office and request a Return Merchandise
without an RMA number.
Before sending the product, clearly write the following information on a piece of paper and
packaging will be your responsibility. FedEx packing or double-boxing are recommended.
ETURNS
If you are located in the U.S., contact Chauvet World Headquarters.
If you are located in the UK or Ireland, contact Chauvet Europe Ltd.
If you are located in Mexico, contact Chauvet Mexico.
If you are located in Benelux, contact Chauvet Europe BVBA.
If you are located in any other country, DO NOT contact Chauvet. Instead, contact your
local distributor. See www.chauvetlighting.com for distributors outside the U.S., UK, Ireland, Mexico, or Benelux.
distributor of record and follow their instructions on how to return Chauvet products
Authorization (RMA) number before shipping the product. Be prepared to provide the model number, serial number, and a brief description of the cause for the return. Send the merchandise prepaid, in its original box, and with its original packing and accessories. Chauvet will not issue call tags. Clearly label the package with the RMA number. Chauvet will refuse any product returned
Write the RMA number on a properly affixed label. DO NOT write the RMA number directly on the box.
place it inside the box:
Your name
Your address
Your phone number
RMA number
A brief description of the problem
Be sure to pack the product properly. Any shipping damage resulting from inadequate
Chauvet reserves the right to use its own discretion to repair or replace returned product(s).
HurricaneTM 1800 Flex User Manual Rev. 8 Page 15 of 16
Page 16
C
WORLD HEADQUARTERS - Chauvet
General Information
Technical Support
www.chauvetlighting.com
UNITED KINGDOM AND IRELAND - Chauvet Europe Ltd.
General Information
Fax: +44 (0)1773 511110
Technical Support
MEXICO - Chauvet Mexico
General Information
Voice: +52 (728) 285-5000
Technical Support
CHAUVET EUROPE - Chauvet Europe BVBA
General Information
Voice: +32 9 388 93 97
Technical Support
contact your dealer. Follow thei r
instructions to request support or to return a product. Visit our website for contact details.
ONTACT US
Address: 5200 NW 108th Avenue Sunrise, FL 33351 Voice: (954) 577-4455 Fax: (954) 929-5560 Toll free: (800) 762-1084
Address: Unit 1C Brookhill Road Industrial Estate Pinxton, Nottingham, UK NG16 6NT Voice: +44 (0)1773 511115
Address: Av. Santa Ana 30 Parque Industrial Lerma Lerma, Mexico C.P. 52000
Address:Stokstraat 18 9770 Kruishoutem Belgium
Voice: (954) 577-4455 (Press 4) Fax: (954) 756-8015 Email: tech@chauvetlighting.com
World Wide Web
Email: uktech@chauvetlighting.com
World Wide Web
www.chauvetlighting.co.uk
Email: servicio@chauvet.com.mx World Wide Web www.chauvet.com.mx
Email: Eutech@chauvetlighting.eu World Wide Web www.chauvetlighting.eu
Outside the U.S., United Ki ngdom, Ireland, Mexico, or Benelux
Page 16 of 16 Hurricane™ 1800 Flex User Manual Rev. 8
Loading...