CHAUVET DJ Geyser RGB Jr. User manual

User Manual
TABLE OF CONTENTS
What is Included ............................................................................................................................... 3
Unpacking Instructions ..................................................................................................................... 3
Claims ....................................................................................................................................................... 3
Text Conventions ............................................................................................................................. 3
Symbols ............................................................................................................................................ 3
Disclaimer ......................................................................................................................................... 3
Product at a Glance .......................................................................................................................... 3
Safety Notes ..................................................................................................................................... 4
2. Introduction ................................................................................................................... 5
Overview ........................................................................................................................................... 5
Dimensions ....................................................................................................................................... 6
AC Power ......................................................................................................................................... 7
Fuse Replacement .................................................................................................................................... 7
Mounting ........................................................................................................................................... 8
Orientation ................................................................................................................................................. 8
Rigging ...................................................................................................................................................... 8
Tank Inversion for Inverted Mounting ............................................................................................. 10
4. Operation ......................................................................................................................11
Control Panel Operation ................................................................................................................. 11
Menu Map ....................................................................................................................................... 11
Configuration (Standalone) ............................................................................................................ 12
Wireless Remote Control ......................................................................................................................... 12
Programmable Color Selection ................................................................................................................ 12
5. Technical Information ..................................................................................................13
Fogger Maintenance ...................................................................................................................... 13
Storage ........................................................................................................................................... 13
General Troubleshooting ................................................................................................................ 14
6. Technical Specifications ..............................................................................................15
Returns ........................................................................................................................................... 16
Contact Us ...................................................................................................................................... 17
Page 2 of 17 Geyser™ RGB Jr. User Manual Rev. 4
What is

Unpacking
Instructions

Carefully unpack the product immediately and check the container to make sure all the
If the box or the contents (the product and included accessories) appear damaged from Failure to report damage to the carrier immediately may invalidate your claim. In
For other issues, such as missing components or parts, damage not related to shipping,
Text
1–512
A range of values
50/60
A set of values of which only one can be chosen
Settings
A menu option not to be modified
Menu > Settings
A sequence of menu options to be followed
<ENTER>
A key to be pressed on the product’s control panel
ON
A value to be entered or selected

Symbols

Critical installation, configuration, or operation information. Not damage to the product, or cause harm to the operator.

Disclaimer

are subject to change
reserves the right to revise or recreate this manual at any time. Download the latest
Product at a
x
P
x
P
x
P
x
x
x

1. BEFORE YOU BEGIN

Included

Claims

Conventions
Geyser™ RGB Jr.
Geyser™ Wireless Remote Control
Geyser™ Wired Remote Receiver
parts are in the package and are in good condition.
shipping, or show signs of mishandling, notify the carrier immediately, not Chauvet. addition, keep the box and contents for inspection.
or concealed damage, file a claim with within 7 days of delivery.
Convention Meaning
Symbol Meaning
Power Cord
Warranty Card
Quick Reference Guide
The information and specifications contained in this User Manual without notice. assumes no responsibility or liability for any errors or omissions, and
version from www.chauvetlighting.com.
© Copyright 2015. All rights reserved.
Electronically published by Chauvet in the United States of America.
Author Date Editor Date
A. Leon 6/1/15 D. Couppe 6/1/15
Use on Dimmer
Glance
Geyser™ RGB Jr. User Manual Rev. 4 Page 3 of 17
Outdoor Use Sound-Activated DMX Master/Slave
following these instructions may make the product not work, cause
Important installation or configuration information. The product may not function correctly if this information is not used.
Useful information.
Auto Programs Fixed voltage (120 V or 230 V) Replaceable Fuse User-Serviceable

Safety Notes

nformation about the mounting, usage, and maintenance
Do not add perfume, alcohol, gasoline, or any other flammables to the fog fluid.
completely disconnect the product from power via breaker or by unplugging it.
to clean your
, no longer than 90 days between
The Geyser™ RGB Jr. was specifically designed for use with CHAUVET® Quick Dissipating Fluid (QDF). For optimum performance with your fogger, Chauvet
These notes include important i of this product; read before using the product.
Always connect the product to a grounded circuit to avoid the risk of electrocution.
Always disconnect the product from the power source before cleaning or replacing
the fuse.
Avoid direct eye exposure to the light source while the product is on.
Make sure the power cord is not crimped or damaged.
Never disconnect the product from power by pulling or tugging on the cord.
If mounting the product overhead, always secure to a fastening device using a
safety cable.
Make sure there are no flammable materials close to the product when operating.
Do not touch the product’s housing when operating because it may be very hot.
Do not mount the product on a flammable surface (linoleum, carpet, wood, paper,
carton, plastic, etc.).
The product’s nozzle is very hot during operation and it remains hot for a long time after operation has stopped.
The fog exits the nozzle at a very high temperature. Keep a minimum distance of
6.5 ft (2 m) from the nozzle to the nearest object.
Do not use the product as a space heater .
Do not drink or become in contact with the fog fluid. If you do, call your local
emergency service (911 in the US) for help.
Always make sure that the voltage of the outlet to which you are connecting the
product is within the range stated on the decal or panel of the product.
The product is for indoor use only! (IP20) To prevent risk of fire or shock, do not expose the product to rain or moisture.
Always install the product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surface s.
Be sure that no ventilation slots on the product’s housing are blocked.
Make sure there is adequate fog fluid in the machine to prevent pump and heater
damage.
Never connect the product to a dimmer.
Make sure to replace the fuse with another of the same type and rating.
Never carry the product by the power cord or any moving part. Always use the
handles.
The maximum ambient temperature (Ta) is 104 °F (40 °C). Do not operate the product at higher temperatures.
In the event of a serious operating problem, stop using the product immediately.
Never try to repair the product. Repairs carried out by unskilled people can lead to
damage or malfunction. Contact the nearest authorized technical assistance center.
This product is not intended for permanent installation.
Use only CHAUVET® water-based fog fluid.
Drain the tank before transporting the product.
To eliminate unnecessary wear and improve its lifespan, during periods of non-use
Keep this User Manual for future use. If you sel l the product to another user, be sure to give this document to the next owner.
Fog Cleaner Quart (FCQ) was specifically developed by Chauvet Geyser™ RGB Jr. Make sure you use FCQ regularly cleanings, to increase the life of your fogger.
recommends using QDF.
Page 4 of 17 Geyser™ RGB Jr. User Manual Rev. 4

2. INTRODUCTION

Overview

Control
Buttons
Fluid Tank
On/Off Switch
Safety Eye
Remote Control
Receiver Port
Manual Fog
Button
Nozzle and LEDs
Handles
Geyser™ RGB Jr. User Manual Rev. 4 Page 5 of 17
LED Display
Loop
Power In
Fuse Holder

Dimensions

2.39 in
(60.8 mm)
16.04 in
(407.5 mm)
10.39 in
(264 mm)
7.55 in
(191.9 mm)
Page 6 of 17 Geyser™ RGB Jr. User Manual Rev. 4

AC Power

supply and it can work with an input
circuit breaker, power outlet, and
’s panel, or refer to
(circuit breaker or fuse). Make
has an appropriate electrical ground to avoid the risk of
to a rheostat (variable resistor) or dimmer circuit, even
Fuse
Installed fuse (held by plastic clip)
Spare fuse holder
(inside safety cap)
Safety cap

3. SETUP

The Geyser™ RGB Jr. has a fixed voltage power voltage of either 120 VAC, 60 Hz or 230 VAC, 50 Hz, depending on the specific model.
To determine the product’s power requirements ( wiring), use the current value listed on the label affixed to the product the product’s specifications chart. The listed current rating indicates the product’s average current draw under normal conditions.
Always connect the product to a protected circuit sure the product electrocution or fire.
Never connect the product if the rheostat or dimmer channel serves only as a 0–100% switch.
Replacement
Disconnect the product from power before replacing the fuse.
1. Disconnect the product from power.
2. Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
3. Pry the fuse holder out of the housing.
4. Remove the blown fuse from the holder.
5. Replace with a fuse of the exact same type and rating.
6. Insert the fuse holder back in place and reconnect power.
A spare fuse is not included; however, the safety cap has room for a spare.
Always replace a blown fuse with another of the same type and rating.
Geyser™ RGB Jr. User Manual Rev. 4 Page 7 of 17

Mounting

, read and follow the safety recommendations indicated in
follow
, remove the fluid
Fluid Tank
To avoid spillage with any mounting, always position the fluid tank with the tank’s
Before mounting the product the Safety Notes.

Orientation

Primarily, the Geyser™ RGB Jr. is to be floor mounted in a vertical fog jet orientation. Alternatively, it may also be mounted in a floor mounting/horizontal fog jet orientation or in an overhead mounting/downward fog jet orientation; however, be sure to instructions closely to avoid tank spills with alternate mounti n gs.
When mounting the Geyser™ RGB Jr. in any inverted position tank from the holder and set it upright on an adjacent surface.

Rigging

Before deciding on a location, always make sure there is easy access to the product for maintenance and fluid replenishment.
Make sure that the structure or surface onto which you are mounting the product can support the product’s weight (see the Technical Specifications).
When mounting the product overhead, always use a safety cable. Mount the product securely to a rigging point, such as an elevated platform or a truss.
When rigging the product onto a truss, you should use mounting clamps of appropriate weight capacity. Two threaded mounting holes (size M12) are on the bottom of the product, which are appropriate for this purpose.
The rubber feet also serve as floor supports. When mounting the product on the floor, make sure that the product and cables are away from people and vehicles.
Floor Mounting
Floor Mounting
Horizontal Fog Jet
Overhead Mounting – Downward Fog Jet
Floor Mounting – Vertical Fog Jet
Position
Page 8 of 17 Geyser™ RGB Jr. User Manual Rev. 4
cap in the uppermost position above the tank’s fluid line.
Fluid Line
Vertical Fog Jet
Horizontal Fog Jet
With inverted mounting, avoid spillage of the fog fluid by setting the fluid tank in an upright position. Be sure to use a safety cable for both the Geyser™ RGB Jr. and the fluid tank when rigging in this manner.
The dimensions shown for the mounting hole positions are included here to aid in
Mounting Clamps for
or
Chauvet)
The Fluid Tank
Overhead Mounting – Downward Fog Jet
(215 mm)
(165 mm)
Bottom Panel View
Threaded Mounting Holes
size M12
Alternate Inverted
Truss Mounting
TRUSST®
(or other elevated
platform or truss)
the Geyser™ RGB Jr.
(works with CLP-15
CLP-15N clamp from
Safety Cable for
the Fluid Tank
in an upright
Safety Cable
position
8.46 in
6.49 in
installation.
Geyser™ RGB Jr. User Manual Rev. 4 Page 9 of 17

Tank Inversion for Invert e d Mount ing

Removable
Plate
1. Remove the screws and the bottle lock to take out the tank.
Bottle Lock
2. Turn the fog machine upside down and remove the screws to take off the removable plate.
3. Attach the removable plate to the opposite side and secure the tank with the bottle lock.
Page 10 of 17 Geyser™ RGB Jr. User Manual Rev. 4

Control Panel
Operation

To access the control panel functions, use the four buttons located underneath the
Button
Function
<DOWN>

Menu Map

rAnd
oFF
The Geyser™ RGB Jr. Wireless Remote Control buttons 1–4 trigger the options set

4. OPERATION

display.
<MENU>
<UP>
<ENTER>
Mode Programming Steps Description
Color Program CH-1–CH-4
Fluid Sensor orL
Selects an operation mode or to backs out of the current menu option Scrolls up the list of options or selects a higher value Scrolls down the list of options or selects a lower value Activates a menu option or a selected value
oFF
Co 1–Co 9
on
Color program off (default) Selects preset color program Selects preset colors
Selects fluid sensor to on or off
in the color programs CH-1–CH-4, respectively.
Geyser™ RGB Jr. User Manual Rev. 4 Page 11 of 17
Configuration
Wireless Remote
To trigger fog output and activate the color program using the wireless remote control, do
If the color program is set to oFF for any trigger button, only fog output is
(Standalone)
Set the product without a DMX controller.
1. Connect the product to a suitable power outlet.
2. Turn the product on.
Control
the following:
1. Plug the wireless receiver into the Remote Control Receiver port on the side of the Geyser™ RGB Jr.
2. On the wireless transmitter, press the button assigned to the color program (1–4). The Geyser™ RGB Jr. emits fog and activates the color program for as long as you hold down the button.
triggered when that button is pressed.
Programmable
Color Selection
To select either the preset color program or one preset color to illuminate the fog using the wireless remote control, follow the instructions below:
1. Press <MENU> repeatedly until CH-1–CH-4 shows on the display. Select CH-1,
CH-2, CH-3, or CH-4 to choose that color program. Note: The color program numbers correspond with the nu m bered buttons on the
wireless transmitter.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to select rAnd (for preset color program) or
Co 1–Co 9 (to choose one of nine preset colors). Note: Select oFF to turn off the color program for that button.
4. Press <ENTER>.
5. Repeat steps 1–4 to configure the other buttons.
Page 12 of 17 Geyser™ RGB Jr. User Manual Rev. 4
Fogger
After every 40 hours of continuous
through the system to prevent the
Fog Cleaner Quart (FCQ) was specifically developed by Chauvet to clean your between cleanings, to increase the life of your fogger.

Storage

Before storing the fogger, run FCQ through the system as described in the cleaning
Cleaning the system prior to storage will help prevent
RGB Jr. on a monthly basis to achieve the best

5. TECHNICAL INFORMATION

Do not allow the fogger to become clogged.
Maintenance
operation, use CHAUVET® F og Cleaner Quart (FCQ) accumulation of particulate matter in the heating element.
The recommended cleaning procedure is as follows.
1. Unplug the product from power.
2. Empty all fog fluid from the machine.
3. Add cleaning solution to the tank.
4. Plug in the product and allow it to warm up.
5. Run the machine in a well-ventilated area until the tank is almost empty. Do not allow the pump to run dry!
6. Refill with fog fluid. Run the machine briefly to clear any cleaning solution from the pump and heater.
Geyser™ RGB Jr. Make sure you use FCQ regularly, no longer than 90 days
procedure above; however, only follow steps 1 through 5. Do not refill the tank with fog fluid if storing the fogger.
any particles from condensing inside the pump or heater while not in use.
Test-run your Geyser™ performance.
Geyser™ RGB Jr. User Manual Rev. 4 Page 13 of 17

General Troubleshooting

Clean thoroughly with CHAUVET® FCQ. For with CHAUVET® water-based fog fluid.
Excessive load on the circuit
Make sure that the total load does not exceed 80% of the breaker or fuse nominal current
Short circuit along the power lines
Check the power lines and power cords
No energy on power outlet
Check power outlet Change to another outlet
Loose or damaged power cord
Check the power cord
Blown fuse
Replace blown fuse with a good one of the same type and rating
Internal problem
Send product for repair
No fluid
Turn the product off and replenish the fog fluid (use only CHAUVET® water-based fog fluid)
Heater or pump
Clean thoroughly with CHAUVET® FCQ. For with CHAUVET® water-based fog fluid.
Wired remote defective
Make sure that the remote is connected available
Inappropriate wired remote operation
See Wireless Remote Control for instructions
Wireless remote connected
Make sure that the wireless remote receiver is
Wireless remote battery
Replace battery on wireless remote transmitter Internal problem
Send the product for repair
If you still experience problems after trying the above solutions, contact Chauvet
Symptom Display Possible Cause Possible Action
No output or low output or fog machine is spitting fluid
Circuit breaker or fuse keeps blowing
Product does not power up
Product does not output fog
Addr” or “HEAT
Off
Off
Addr” or “HEAT
Wrong fluid
Blocked pipes or failing part
clogged
disconnected or
receiver not
full instructions, see F ogger Maintenance. Refill
Contact Customer Service
full instructions, see F ogger Maintenance. Refill
Try the remote on another Geyser™ RGB Jr. if
connected
Technical Support.
transmitter ran out of
Page 14 of 17 Geyser™ RGB Jr. User Manual Rev. 4
Dimensions and
Length
Width
Height
Weight
16.04 in (407.5 mm)
10.39 in (264 mm)
7.55 in (191.9 mm)
16 lb (7.3 kg)
Note: Dimensions in inches rounded to the nearest decimal digit.
Power
Power Supply Type
Range
Voltage Selection
120 VAC, 60 Hz
or 230 VAC, 50 Hz
Parameter
120 V, 60 Hz
230 V, 50 Hz
Consumption
670 W
690 W
Operating current
5.63 A
3 A
Fuse
F 7 A, 250 V
F 7 A, 250 V
Power I/O
US/Worldwide
UK/Europe
Power input connector
IEC
IEC
Power output connector
Edison
IEC
Power Cord plug
Edison (US)
Local plug
Light Source
Type
Power
Lifespan
LED
3 W
50,000 hours
Color
Quantity
Current
Red
3
900 mA
Green
3
900 mA
Blue
3
900 mA
Operation/Capacity/
Consumption
Heat-up Time
Tank Capacity
Fluid Consumption
5 min
2.5 l
123 ml/min
Misc.
Output
13,500 cfm
Thermal
Maximum External Temp.
Cooling System
104 °F (40 °C)
Convection
Ordering
Product Name
Item Code
UPC Number
Geyser™ RGB Jr.
05070758
781462211066
Geyser™ RGB Jr. 220 V
05070761
781462211097

6. TECHNICAL SPECIFICATIONS

Weight
Model-specific
Fixed
Geyser™ RGB Jr. User Manual Rev. 4 Page 15 of 17
, contact

Returns

Support office and request a Return
prepared to
provide the model number, serial number, and a brief description of the cause for the
You must send the merchandise prepaid, in its original box, and with its original packing
the following information on a piece of paper
properly. Any shipping damage resulting from inadequate
reserves the right to use its own discretion to repair or replace returned
To return a product or request support:
In the U.S., contact Chauvet World Headquarters (see Contact Us).
In the UK or Ireland, contact Chauvet Europe Ltd. (see Contact Us).
In Mexico, contact Chauvet Mexico (see Contact Us).
In Benelux, contact Chauvet Europe BVBA (see Contact Us).
In any other country, DO NOT contact Chauvet. Contact y our distribut or. See
www.chauvetlighting.com for distribut ors outs ide the U .S., United Kingdom, Ireland,
Mexico, or Benelux.
If you live outside the U.S., United Kingdom, Ireland, Mexico, or Benelux your distributor of record and follow their instructions on how to return Chauvet products to them. Visit our website for contact details.
Call the corresponding Chauvet Technical Merchandise Authorization (RMA) number before shipping the product. Be
return.
and accessories. Chauvet will not issue call tags. Clearly label the package with the RMA number. Chauvet will refuse any product
returned without an RMA number.
Write the RMA number on a properly affixed label. DO NOT write the RMA number directly on the box.
Before sending the product, clearly write and place it inside the box:
Your name
Your address
Your phone number
RMA number
A brief description of the problem
Be sure to pack the product packaging will be your responsibility. FedEx packing or double-boxing are recommended.
Chauvet product(s).
Page 16 of 17 Geyser™ RGB Jr. User Manual Rev. 4

Contact Us

WORLD HEADQUARTERS - Chauvet
General Information
Toll free: (800) 762-1084
Technical Support
World Wide Web www.chauvetlighting.com
UNITED KINGDOM AND IRELAND - Chauvet Europe Ltd.
General Information
Fax: +44 (0)1773 511110
Technical Support
MEXICO - Chauvet Mexico
General Information
Voice: +52 (728) 285-5000
Technical Support
CHAUVET EUROPE - Chauvet Europe BVBA
General Information
Voice: +32 9 388 93 97
Technical Support
instructions to request support or to return a product. Visit our website for contact details.
Address: 5200 NW 108th Avenue Sunrise, FL 33351 Voice: (954) 577-4455 Fax: (954) 929-5560
Address: Unit 1C Brookhill Road Industrial Estate Pinxton, Nottingham, UK
Voice: (954) 577-4455 (Press 4) Fax: (954) 756-8015 Email: tech@chauvetlighting.com
Email: uktech@chauvetlighting.com
World Wide Web www.chauvetlighting.co.uk NG16 6NT Voice: +44 (0)1773 511115
Address: Av. Santa Ana 30 Parque Industrial Lerma Lerma, Mexico C.P. 52000
Address: Stokstraat 18 9770 Kruishoutem Belgium
Email: servicio@chauvet.com.mx
World Wide Web www.chauvet.com.mx
Email: Eutech@chauvetlighting.eu
World Wide Web www.chauvetlighting.eu
Outside the U.S., United Kingdom, Ireland, Mexico, or Benelux, contact your dealer. Follow their
Geyser™ RGB Jr. User Manual Rev. 4 Page 17 of 17
Loading...