The Geyser P5 Quick Reference Guide (QRG) has basic product information such as menu options. Download the User
Manual from www.chauvetdj.com
Disclaimer
The information and specifications contained in this QRG are subject to change without notice.
Safety Notes
These Safety Notes include important information about installation, use, and maintenance.
•This product is not intended for permanent installation.
•ONLY connect this product to a grounded and protected circuit.
•Always disconnect from power before cleaning or replacing the fuse.
•Make sure the power cord is not crimped or damaged.
•Never disconnect this product from power by pulling on the cord.
•DO NOT touch this product when it is operating because it may be hot.
•Do not set this product on a flammable surface (linoleum, carp et, wood, paper , carton, plastic, etc.).
•Do not touch the output nozzle on this product. It is very hot during operation and it may remain
hot for several hours after turning the unit off.
•Depending on the amount of fog ge ne rated, all fog machines may set off smoke detectors.
•The voltage of the outlet to which you are connec ting this product must be within the range stated
on the decal or rear panel of the product.
•This product is for indoor use only! (IP20) To prevent risk of fire or shock, do not expose this
product to rain or moisture.
•Always mount this product in a location with adequate ventilation, at least 20 in (50 cm) from
adjacent surfaces.
•Be sure that no ventilation slots on the unit’s housing are blocked.
•Never connect this product to a dimmer or rheostat.
•Replace the fuse with one of the same type and rating.
•ONLY use the carry handle to carry this product.
•The maximum ambient temperature is 104 °F (40 °C). Do not operate this product at higher
temperatures.
•In the event of a serious operating problem, stop using immediately.
•DO NOT open this product. It contains no user-serviceable parts.
•Do not use for space heating purposes.
•Use only CHAUVET water-based fog fluid.
•Drain the tank before transporting or storing the product.
•To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely
disconnect the product from power via the breaker or by unplugging it.
for more details.
Contact
Outside the U.S., United Kingdom, Ireland, Mexico, or Benelux, contact your distributor to request support or return a
product. Visit www.chauvetdj.com
for contact information.
What is Included
•Geyser P5
•Power Cord
•Geyser Wireless Remote Control and Receiver
•Warranty Card
•Quick Reference Guide
To Begin
Unpack your Geyser P5 and make sure you have received all parts in good condition. If the box or contents appear
damaged, notify the carrier immediately, not Chauvet.
1
Geyser P5 QRG Rev. 2
Product Overview
Power
In
Fuse
Holder
LED Display
Penta-color LEDs
Fan
Manual Button
Controller InCarry Handle
Fluid T ank
Fluid Level Indicator
Menu Buttons
Nozzle
Rubber Feet for
Surface Mounting
(x4)
Power
Switch
Safety
Loop
DMX
In/Out
QUICK REFERENCE GUIDE
EN
FCQ (Fog Cleaner Quart) was specifically developed by Chauvet to clean your Geyser P5. Make
sure you use FCQ regularly, no longer than 90 days between cleanings, to increase the life of
your product.
While operating the Geyser P5, make sure there is adequate fog fluid in the machine to prevent
pump and heater damage. When the fog fluid level becomes low, simply add more fog fluid to
continue using the Geyser P5.
AC Power
This product has a fixed voltage power supply and it can work with an input voltage of either 120 V AC, 60 Hz or 230 V AC,
50 Hz, depending on the specific model.
To eliminate wear and improve its lifespan, during periods of non-use completely disconnect the
product from power via breaker or by unplugging it.
Fuse Replacement
1.Disconnect the product from power.
2.Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
3.Pry the safety cap out of the housing.
4.Remove the blown fuse from the clip on the front of the safety cap and replace with a fuse of the exact same
type and rating.
5.Re-insert the fuse holder and reconnect power.
Control Panel Description
BUTTONFUNCTION
<MENU>Exits from the current menu or function
<UP>Navigates upwards through the menu list and incr e ase s the nu m er ic valu e wh en in a func tion
<DOWN>Navigates downwards through the menu list and decreases the numeric value when in a function
<ENTER>
Enables the currently displayed menu or sets the curr en tly se lec ted valu e into the sele cted
function
Geyser P5 QRG Rev. 2
2
QUICK REFERENCE GUIDE
EN
Menu Map
MAIN LEVELPROGRAMMING LEVELSDESCRIPTION
Addr1–512Sets the DMX starting address
oFFNo color output
Co 1Red
Co 2Green
Co 3Blue
Co 4Amber
Co 5Ultraviolet
CH-1–4
Wireless Remote Control
To trigger fog output and activate the color program using the wireless remote control, do the following:
1.Plug the wireless receiver into the Controller In port on the side of the Geyser P5.
2.Program the color choice for each button on the remote (<1>–<4>), using the CH-1–4 menu options on the
Geyser P5.
3.On the wireless transmitter, press the button assigned to the desired color program (<1>–<4>). The Geyser P5
emits fog and outputs color for as long as the button is held down.
DMX Linking
The Geyser P5 can work with a DMX controller. Instructions for connecting and configuring this product for DMX
operation are in the User Manual. If you are not familiar with DMX, download the DMX Primer from www.chauvetdj.com
Starting Address
To ensure full access to all channels available in each DMX mode, the highest recommended DMX address is 503.
DMX Values
10Ch
CHANNELFUNCTIONVALUEPERCENT/SETTING
1Fog
2Red
3Green
4Blue
5Amber
6Ultraviolet
7Color Macro
8Color Macro Speed
9Strobe
10Dimmer
Co 6Hot pink
Co 7Pink
Co 8Yellow
Co 9Magenta
Co10Cyan
Co11White
randRandom color output
000
009No function
010
255Output fog
000
014No function
015
2550–100%
000
014No function
015
2550–100%
000
014No function
015
2550–100%
000
014No function
015
2550–100%
000
014No function
015
2550–100%
000
009No function
010
255Color macros
000
009No function
010
255Color macro speed, slow to fast
000
009No function
010
255Strobe, slow to fast
000
014No function
015
2550–100%
.
The LEDs will automatically shut off after 60 seconds of sustained output. Reset the dimmer
to re-enable LED output.
3
Geyser P5 QRG Rev. 2
GUÍA DE REFERENCIA RÁPIDA
Acerca de esta guía
La guía de referencia rápida (GRR) del Geyser P5 contiene información básica sobre el producto, como montaje y
opciones de menú. Descargue el manual de usuario de www.chauvetdj.com
Exención de responsabilidad
La información y especificaciones contenidas en esta GRR están sujetas a cambio sin previo aviso.
Notas de seguridad
Estas notas de seguridad incluyen información importante sobre el montaje, uso y mantenimiento.
•Este producto no está concebido para una instalación permanente.
•Conecte este producto SOLO a un circuito con toma de tierra y protegido.
•Desconecte siempre de la alimentación antes de la limpieza o sustitución del fusible.
•Asegúrese de que el cable de alimentación no está retorcido ni estropeado.
•Nunca desconecte este producto de la alimentación tirando del cable.
•NO toque este producto cuando esté en funcionamiento, pues podría estar caliente.
•No coloque este producto sobre una superficie inflamable (linóleo, alfombra, madera, papel,
cartón, plástico, etc.).
•NO toque la boquilla de salida de este producto. Se calienta mucho durante el funcionamiento, y
puede permanecer caliente durante varias horas después de apagar la unidad.
•Dependiendo de la cantidad de niebla generada, todas las máquinas de niebla pueden disparar
los detectores de humo.
•La tensión del enchufe al que conecte est e pr od u c to ha de estar en el rango establecido en el
grabado o en el panel posterior del producto.
•¡Este producto es para uso en interiores solamente! (IP20) Para evitar riesgos de incendio o
descarga, no exponga este producto a la lluvia o la humedad.
•Monte siempre este producto en una ubicación con ventilación adecuada, al menos a 20 in (50
cm) de superficies adyacentes.
•Asegúrese de que ninguna ranura de ventilación en la carcasa de la unidad queda bloqueada.
•Nunca conecte este producto a un atenuador o reostato.
•Sustituya el fusible con otro del mismo tipo y categoría.
•Use SOLAMENTE el asa de transporte para mover este producto.
•La temperatura ambiente máxima es de 104 °F (40 °C). No haga funcionar este producto a
temperaturas más altas.
•En caso de un problema grave de funcionamiento, deje de usarlo inmediatamente.
•NO abra este producto. No contiene ninguna pieza reparable por el usuario.
•No utilizar para calentar espacios.
•Use solo fluido de niebla a base de agua CHAUVET.
•Vacíe el depósito antes de transportar o almacenar el producto.
•Para evitar un desgaste innecesario y alargar su vida útil, desconecte completamente el producto
de la alimentación mediante el interruptor o de senchufándolo du rante period os en que no se use.
para una información más detallada.
ES
Contacto
Fuera de EE. UU., Reino Unido, Irlanda, México o Benelux póngase en contacto con su distribuidor para solicitar
asistencia o devolver un producto. Visite www.chauvetdj.com para información de contacto.
Qué va incluido
•Geyser P5
•Cable de alimentación
•Receptor y control remoto inalámbrico Geyser
•Tarjeta de garantía
•Guía de referencia rápida
Para empezar
Desembale su Geyser P5 y asegúrese de que ha recibido todas las partes en buen esta do. Si la caja o los comp onentes
parecen dañados, notifíqueselo inmediatamente al transportista, no a Chauvet.
Geyser P5 GRR Rev. 2
4
ES
Entrada de
alimentación
Portafusibles
Pantalla LED
LED de cinco
colores
Ventilador
Botón manual
Entrada de
controlador
Asa de transporte
Depósito de líquido
Indicador de nivel
de fluido
Botones de menú
Boquilla
Pies de goma
para montaje en
superficie (x4)
Interruptor de
alimentación
Lazo de
seguridad
Entrada/Salida
DMX
Visión general del producto
GUÍA DE REFERENCIA RÁPIDA
El FCQ (cuarto de galón de limpiador de niebla) ha sido especialmente desarrollado por Chauvet
para limpiar su Geyser P5. Asegúrese de usar FCQ regularmente, no más de 90 días entre
limpiezas, para incrementar la vida de su producto.
Cuando ponga en marcha el Geyser P5, cerciórese de que hay fluido de niebla adecuado en la
máquina, para evitar que se estropeen la bomba y el calentador. Cuando el nivel de fluido esté
bajo, no tiene más que añadir fluido para seguir usando el Geyser P5.
Corriente alterna
El producto tiene una fuente de alimentación fija y puede funcionar con una tensión de e ntrada d e 120 VCA 60 Hz o 230
VCA 50 Hz, dependiendo del modelo en concreto.
Para evitar un desgaste innecesario y alargar su vida út il, desconecte completamente el pr oducto
de la alimentación mediante el interruptor o desenchufánd olo durant e periodos en que n o se use.
Sustitución del fusible
1.Desconecte el producto de la alimentación.
2.Haga cuña con la punta de un destornillador plano en la ranura del portafusibles.
3.Saque la tapa de seguridad de la carcasa.
4.Quite el fusible fundido de la sujeción en la parte frontal de la tapa de seguridad y sustituya el fusible con otro
Descripción del panel de control
del mismo tipo y categoría.
5.Vuelva a insertar el portafusibles y conecte de nuevo la alimentación.
BOTÓNFUNCIÓN
<MENU>Sale del menú o función actual
<UP>Navega hacia arriba por la lista de menú y aumenta el valor numérico cuando está en una función
<DOWN>Navega hacia abajo por la lista de menú y disminuye el valor numérico cuando está en una función
<ENTER>
Habilita el menú actualmente en pantalla o configura el valor seleccionado actualmente dentro de la