Chauvet DJ Geyser P5 Quick Start Guide

Quick Reference Guide
QUICK REFERENCE GUIDE
EN

About This Guide

The Geyser P5 Quick Reference Guide (QRG) has basic product information such as menu options. Download the User Manual from www.chauvetdj.com

Disclaimer

The information and specifications contained in this QRG are subject to change without notice.

Safety Notes

These Safety Notes include important information about installation, use, and maintenance.
This product is not intended for permanent installation.
ONLY connect this product to a grounded and protected circuit.
Always disconnect from power before cleaning or replacing the fuse.
Make sure the power cord is not crimped or damaged.
Never disconnect this product from power by pulling on the cord.
DO NOT touch this product when it is operating because it may be hot.
Do not set this product on a flammable surface (linoleum, carp et, wood, paper , carton, plastic, etc.).
Do not touch the output nozzle on this product. It is very hot during operation and it may remain hot for several hours after turning the unit off.
Depending on the amount of fog ge ne rated, all fog machines may set off smoke detectors.
The voltage of the outlet to which you are connec ting this product must be within the range stated on the decal or rear panel of the product.
This product is for indoor use only! (IP20) To prevent risk of fire or shock, do not expose this product to rain or moisture.
Always mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
Be sure that no ventilation slots on the unit’s housing are blocked.
Never connect this product to a dimmer or rheostat.
Replace the fuse with one of the same type and rating.
ONLY use the carry handle to carry this product.
The maximum ambient temperature is 104 °F (40 °C). Do not operate this product at higher temperatures.
In the event of a serious operating problem, stop using immediately.
DO NOT open this product. It contains no user-serviceable parts.
Do not use for space heating purposes.
Use only CHAUVET water-based fog fluid.
Drain the tank before transporting or storing the product.
To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via the breaker or by unplugging it.

Contact

Outside the U.S., United Kingdom, Ireland, Mexico, or Benelux, contact your distributor to request support or return a product. Visit www.chauvetdj.com
for contact information.

What is Included

•Geyser P5
Power Cord
Geyser Wireless Remote Control and Receiver
Warranty Card
Quick Reference Guide

To Begin

Unpack your Geyser P5 and make sure you have received all parts in good condition. If the box or contents appear damaged, notify the carrier immediately, not Chauvet.
1
Geyser P5 QRG Rev. 2

Product Overview

Power
In
Fuse
Holder
LED Display
Penta-color LEDs
Fan
Manual Button
Controller In Carry Handle
Fluid T ank
Fluid Level Indicator
Menu Buttons
Nozzle
Rubber Feet for
Surface Mounting
(x4)
Power
Switch
Safety
Loop
DMX
In/Out
QUICK REFERENCE GUIDE
EN
FCQ (Fog Cleaner Quart) was specifically developed by Chauvet to clean your Geyser P5. Make sure you use FCQ regularly, no longer than 90 days between cleanings, to increase the life of your product.
While operating the Geyser P5, make sure there is adequate fog fluid in the machine to prevent pump and heater damage. When the fog fluid level becomes low, simply add more fog fluid to continue using the Geyser P5.

AC Power

This product has a fixed voltage power supply and it can work with an input voltage of either 120 V AC, 60 Hz or 230 V AC, 50 Hz, depending on the specific model.
To eliminate wear and improve its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it.

Fuse Replacement

1. Disconnect the product from power.
2. Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
3. Pry the safety cap out of the housing.
4. Remove the blown fuse from the clip on the front of the safety cap and replace with a fuse of the exact same type and rating.
5. Re-insert the fuse holder and reconnect power.

Control Panel Description

BUTTON FUNCTION <MENU> Exits from the current menu or function
<UP> Navigates upwards through the menu list and incr e ase s the nu m er ic valu e wh en in a func tion
<DOWN> Navigates downwards through the menu list and decreases the numeric value when in a function
<ENTER>
Enables the currently displayed menu or sets the curr en tly se lec ted valu e into the sele cted function
Geyser P5 QRG Rev. 2
2
QUICK REFERENCE GUIDE
EN

Menu Map

MAIN LEVEL PROGRAMMING LEVELS DESCRIPTION
Addr 1–512 Sets the DMX starting address
oFF No color output Co 1 Red Co 2 Green Co 3 Blue Co 4 Amber Co 5 Ultraviolet
CH-1–4

Wireless Remote Control

To trigger fog output and activate the color program using the wireless remote control, do the following:
1. Plug the wireless receiver into the Controller In port on the side of the Geyser P5.
2. Program the color choice for each button on the remote (<1>–<4>), using the CH-1–4 menu options on the Geyser P5.
3. On the wireless transmitter, press the button assigned to the desired color program (<1>–<4>). The Geyser P5 emits fog and outputs color for as long as the button is held down.

DMX Linking

The Geyser P5 can work with a DMX controller. Instructions for connecting and configuring this product for DMX operation are in the User Manual. If you are not familiar with DMX, download the DMX Primer from www.chauvetdj.com

Starting Address

To ensure full access to all channels available in each DMX mode, the highest recommended DMX address is 503.

DMX Values

10Ch

CHANNEL FUNCTION VALUE PERCENT/SETTING
1 Fog
2Red
3Green
4Blue
5Amber
6 Ultraviolet
7 Color Macro
8 Color Macro Speed
9 Strobe
10 Dimmer
Co 6 Hot pink Co 7 Pink Co 8 Yellow
Co 9 Magenta Co10 Cyan Co11 White
rand Random color output
000
009 No function
010
255 Output fog
000
014 No function
015
255 0–100%
000
014 No function
015
255 0–100%
000
014 No function
015
255 0–100%
000
014 No function
015
255 0–100%
000
014 No function
015
255 0–100%
000
009 No function
010
255 Color macros
000
009 No function
010
255 Color macro speed, slow to fast
000
009 No function
010
255 Strobe, slow to fast
000
014 No function
015
255 0–100%
.
The LEDs will automatically shut off after 60 seconds of sustained output. Reset the dimmer to re-enable LED output.
3
Geyser P5 QRG Rev. 2
GUÍA DE REFERENCIA RÁPIDA

Acerca de esta guía

La guía de referencia rápida (GRR) del Geyser P5 contiene información básica sobre el producto, como montaje y opciones de menú. Descargue el manual de usuario de www.chauvetdj.com

Exención de responsabilidad

La información y especificaciones contenidas en esta GRR están sujetas a cambio sin previo aviso.

Notas de seguridad

Estas notas de seguridad incluyen información importante sobre el montaje, uso y mantenimiento.
Este producto no está concebido para una instalación permanente.
Conecte este producto SOLO a un circuito con toma de tierra y protegido.
Desconecte siempre de la alimentación antes de la limpieza o sustitución del fusible.
Asegúrese de que el cable de alimentación no está retorcido ni estropeado.
Nunca desconecte este producto de la alimentación tirando del cable.
NO toque este producto cuando esté en funcionamiento, pues podría estar caliente.
No coloque este producto sobre una superficie inflamable (linóleo, alfombra, madera, papel, cartón, plástico, etc.).
NO toque la boquilla de salida de este producto. Se calienta mucho durante el funcionamiento, y puede permanecer caliente durante varias horas después de apagar la unidad.
Dependiendo de la cantidad de niebla generada, todas las máquinas de niebla pueden disparar los detectores de humo.
La tensión del enchufe al que conecte est e pr od u c to ha de estar en el rango establecido en el grabado o en el panel posterior del producto.
¡Este producto es para uso en interiores solamente! (IP20) Para evitar riesgos de incendio o descarga, no exponga este producto a la lluvia o la humedad.
Monte siempre este producto en una ubicación con ventilación adecuada, al menos a 20 in (50 cm) de superficies adyacentes.
Asegúrese de que ninguna ranura de ventilación en la carcasa de la unidad queda bloqueada.
Nunca conecte este producto a un atenuador o reostato.
Sustituya el fusible con otro del mismo tipo y categoría.
Use SOLAMENTE el asa de transporte para mover este producto.
La temperatura ambiente máxima es de 104 °F (40 °C). No haga funcionar este producto a temperaturas más altas.
En caso de un problema grave de funcionamiento, deje de usarlo inmediatamente.
NO abra este producto. No contiene ninguna pieza reparable por el usuario.
No utilizar para calentar espacios.
Use solo fluido de niebla a base de agua CHAUVET.
Vacíe el depósito antes de transportar o almacenar el producto.
Para evitar un desgaste innecesario y alargar su vida útil, desconecte completamente el producto de la alimentación mediante el interruptor o de senchufándolo du rante period os en que no se use.
para una información más detallada.
ES

Contacto

Fuera de EE. UU., Reino Unido, Irlanda, México o Benelux póngase en contacto con su distribuidor para solicitar asistencia o devolver un producto. Visite www.chauvetdj.com para información de contacto.

Qué va incluido

•Geyser P5
Cable de alimentación
Receptor y control remoto inalámbrico Geyser
Tarjeta de garantía
Guía de referencia rápida

Para empezar

Desembale su Geyser P5 y asegúrese de que ha recibido todas las partes en buen esta do. Si la caja o los comp onentes parecen dañados, notifíqueselo inmediatamente al transportista, no a Chauvet.
Geyser P5 GRR Rev. 2
4
ES
Entrada de
alimentación
Portafusibles
Pantalla LED
LED de cinco
colores
Ventilador
Botón manual
Entrada de
controlador
Asa de transporte
Depósito de líquido
Indicador de nivel
de fluido
Botones de menú
Boquilla
Pies de goma
para montaje en
superficie (x4)
Interruptor de
alimentación
Lazo de
seguridad
Entrada/Salida
DMX

Visión general del producto

GUÍA DE REFERENCIA RÁPIDA
El FCQ (cuarto de galón de limpiador de niebla) ha sido especialmente desarrollado por Chauvet para limpiar su Geyser P5. Asegúrese de usar FCQ regularmente, no más de 90 días entre limpiezas, para incrementar la vida de su producto.
Cuando ponga en marcha el Geyser P5, cerciórese de que hay fluido de niebla adecuado en la máquina, para evitar que se estropeen la bomba y el calentador. Cuando el nivel de fluido esté bajo, no tiene más que añadir fluido para seguir usando el Geyser P5.

Corriente alterna

El producto tiene una fuente de alimentación fija y puede funcionar con una tensión de e ntrada d e 120 VCA 60 Hz o 230 VCA 50 Hz, dependiendo del modelo en concreto.
Para evitar un desgaste innecesario y alargar su vida út il, desconecte completamente el pr oducto de la alimentación mediante el interruptor o desenchufánd olo durant e periodos en que n o se use.

Sustitución del fusible

1. Desconecte el producto de la alimentación.
2. Haga cuña con la punta de un destornillador plano en la ranura del portafusibles.
3. Saque la tapa de seguridad de la carcasa.
4. Quite el fusible fundido de la sujeción en la parte frontal de la tapa de seguridad y sustituya el fusible con otro

Descripción del panel de control

del mismo tipo y categoría.
5. Vuelva a insertar el portafusibles y conecte de nuevo la alimentación.
BOTÓN FUNCIÓN
<MENU> Sale del menú o función actual
<UP> Navega hacia arriba por la lista de menú y aumenta el valor numérico cuando está en una función
<DOWN> Navega hacia abajo por la lista de menú y disminuye el valor numérico cuando está en una función
<ENTER>
Habilita el menú actualmente en pantalla o configura el valor seleccionado actualmente dentro de la función seleccionada
5
Geyser P5 GRR Rev. 2
Loading...
+ 14 hidden pages