Champion D-LF User Manual

Project Item No. Quantity
D-LF DOOR-TYPE
STANDARD FEATURES
Automatic tank fill•
Electric tank heat•
Balanced door lift system•
Corner model available (contact factory)•
Automatic electric drain valve•
Low-water tank heat protection•
1 Hp drip-proof pump motor•
Door safety switches•
Top-mounted, splash-proof control console•
Interchangeable upper and lower spray arms•
Stainless steel pump impeller•
Stainless steel front and side panels•
Detergent/chemical connection provisions•
Single point electrical connection (see chart)•
Vent fan control•
D-LF
Door-type
Low Temperature
Dishwashing Machine
OPTIONS & ACCESSORIES
Steam coil tank operation
Corner operation
CH018
(1M) 10/08 Printed in U.S.A.
SPECIFIER STATEMENT
Specified unit will be Champion model D-LF low temperature dishwashing machine.
Features top mounted control cabinet, balanced door lift with safety latch, interchangeable stainless steel wash and rinse arms, 55 racks/hr., 1.1 US gals/rack. Constructed of type 304 SST.
1 year parts and labor warranty.
Champion Industries, Inc.
P. O. Box 4149, Winston-Salem, NC 27115
Tel: 336/661-1556 Fax: 336/661-1979
2674 N. Service Road,
Jordan Station, Ontario, Canada L0R 1S0
Tel: 800/263-5798 Fax: 905/562-4618
www.championindustries.com
D-LF
Inside Tracks
2-7/8" [73]
5-1/4" [133] Min.
FRONT
20-1/8"[511]
5-1/4" [133] Min.
1
13" [330]
32
19"
[483]
26"
[660]
2
3
1
[102] 4"
26" [660]
9-1/4"
[229]
19-1/4"
[489]
13-3/4" [343]
24-1/4" [616]
7-1/4" [184]
2-1/8" [54]
1-1/4" [32] Roll
20-7/8" [530]
1-1/8"
[29]
60-1/2" [1537]
8-7/8" [225]
A A
1
1" [279]
231
84" [2134]
Door
Removal
75" [1805]
Doors Up
57-1/2" [1461]
Machine
Height
34" [864]
Load
Height
17" [432]
Clearance
20-1/4" [511]
Inside Track
2-7/8" [73]
FRONT
5-1/4" [133] Min.
Door-type Low Temperature Dishwashing Machine
D-LF DOOR-TYPE
Straight-through
Configuration
Dimensions shown in inches and [millimeters]
Length between table connections: 26"/660 mm Volume crated: 51 cu. ft./1.45 cu.m. Shipping weight crated: 325 lbs./148 kg
Side ViewFront View
SPECIFICATIONS
Corner Configuration
Typical Table
Construction
Utilities
1 Electrical: (See Box)
2 Hot water:
Plan View
Caution: Silver, aluminum and pewter are attacked by sodium hypochlorite (liquid bleach). Champion low temperature dishwashing machines are designed for liquid bleach solutions not exceeding 50 ppm.
For Electric Heat Minimum Maximum
Supply Ckt. Overcurrent Elec. Rated Conductor Protective Specs. Amps Ampacity Device
115/60/1* 48 55 55 208/60/1 35 45 45 240/60/1 37 45 45 208/60/3 20 25 25 240/60/3 21 25 25 480/60/3 9 15 15 575/60/3 7 15 15
* 3kW wash tank heater
ChampionIndustries,Inc.,P.O.Box4149,Winston-Salem,NC27115•336/661-1556•Fax:336/661-1979•www.championindustries.com
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
2674 N. Service Road
3/4" NPT 140°F/60°C hot water connection. Flow pressure 20-22 psi. (138-151 kPa).
3 Drain: 2" O.D. connection. Max. flow 15
US gpm (12 imp. gpm/54 lpm.) 3/4" NPT machine return to boiler
A. Steam Injector Condensate B. Steam Coil Condensate
For Steam Heat
Minimum Maximum Supply Ckt. Overcurrent Elec. Rated Conductor Protective Specs. Amps Ampacity Device
115/60/1 22 30 30 208/60/1 12 15 15 240/60/1 11 15 15 208/60/3 6 15 15 240/60/3 6 15 15 480/60/3 3 15 15 575/60/3 3 15 15
Jordan Station, Ontario, Canada L0R 1S0
•
800/263-5798
•
Capacities
Racks per hr. (NSF rated) 55 Wash tank US gal.
(imp. gal./liters) 9 (7.5/34)
Wash motor horsepower Water consumption
Gal. per hr. (max. use)
US gal. (imp. gal./liters) 66 (55/248)
Gal. per rack
US gal. (imp. gal./liters) 1.2 (0.96/4.4)
Temperatures °F/°C
Wash 140/60 Rinse 140/60
Heating
Tank heat, electric (kW) 4.7
Time cycle in seconds
Wash 45 Dwell 1 Rinse 14 Total cycle 60