Project 
Item No. 
Quantity
D-LF DOOR-TYPE
STANDARD FEATURES
Automatic tank fill•
Electric tank heat•
Balanced door lift system•
Corner model available (contact factory)•
Automatic electric drain valve•
Low-water tank heat protection•
1 Hp drip-proof pump motor•
Door safety switches•
Top-mounted, splash-proof control console•
Interchangeable upper and lower spray arms•
Stainless steel pump impeller•
Stainless steel front and side panels•
Detergent/chemical connection provisions•
Single point electrical connection (see chart)•
Vent fan control•
 D-LF
Door-type 
Low Temperature 
Dishwashing Machine
OPTIONS & ACCESSORIES
Steam coil tank operation
Corner operation
CH018
(1M) 10/08  Printed in U.S.A.
SPECIFIER STATEMENT
Specified unit will be Champion model D-LF low temperature 
dishwashing machine.
Features top mounted control cabinet, balanced door lift with 
safety latch, interchangeable stainless steel wash and rinse 
arms, 55 racks/hr., 1.1 US gals/rack. Constructed of type 
304 SST.
1 year parts and labor warranty.
Champion Industries, Inc. 
P. O. Box 4149, Winston-Salem, NC 27115 
Tel: 336/661-1556  Fax: 336/661-1979
 2674 N. Service Road, 
Jordan Station, Ontario, Canada L0R 1S0 
Tel: 800/263-5798  Fax: 905/562-4618 
  www.championindustries.com
 

D-LF
Inside Tracks
2-7/8" [73]
5-1/4" [133] Min.
FRONT
20-1/8"[511]
5-1/4" [133] Min.
1
13" [330]
32
19"
[483]
26"
[660]
2
3
1
[102] 4"
26" [660]
9-1/4"
[229]
19-1/4"
[489]
13-3/4" [343]
24-1/4" [616]
7-1/4" [184]
2-1/8" [54]
1-1/4" [32] Roll
20-7/8" [530]
1-1/8" 
[29]
 60-1/2" [1537]
8-7/8" [225]
A A
1
1" [279]
231
84" [2134]
Door
Removal
75" [1805]
Doors Up
57-1/2" [1461]
Machine 
Height
34" [864]
Load
Height
17" [432]
Clearance
20-1/4" [511]
Inside Track
2-7/8" [73]
FRONT
5-1/4" [133] Min.
Door-type  
Low Temperature  
Dishwashing Machine
 D-LF DOOR-TYPE
Straight-through 
Configuration
Dimensions shown in inches and [millimeters]
Length between table connections:  26"/660 mm 
Volume crated:  51 cu. ft./1.45 cu.m. 
Shipping weight crated:  325 lbs./148 kg
Side ViewFront View
SPECIFICATIONS
Corner Configuration
Typical Table 
Construction
Utilities
 1 Electrical: (See Box)
 2  Hot water: 
Plan View
Caution: Silver, aluminum and pewter are attacked 
by sodium hypochlorite (liquid bleach). Champion low 
temperature dishwashing machines are designed for 
liquid bleach solutions not exceeding 50 ppm.
 For Electric Heat 
      Minimum  Maximum 
      Supply Ckt. Overcurrent 
 Elec.  Rated Conductor  Protective 
 Specs.  Amps  Ampacity  Device
 115/60/1*  48  55  55 
 208/60/1  35  45  45 
 240/60/1  37  45  45 
 208/60/3  20  25  25 
 240/60/3  21  25  25 
 480/60/3  9  15  15 
 575/60/3  7  15  15
* 3kW wash tank heater
ChampionIndustries,Inc.,P.O.Box4149,Winston-Salem,NC27115•336/661-1556•Fax:336/661-1979•www.championindustries.com 
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
2674 N. Service Road
3/4" NPT 140°F/60°C hot water connection.  
Flow pressure 20-22 psi. (138-151 kPa).
 3  Drain: 2" O.D. connection. Max. flow 15 
US gpm (12 imp. gpm/54 lpm.) 
3/4" NPT machine return to boiler
A. Steam Injector Condensate 
B. Steam Coil Condensate
 For Steam Heat
      Minimum  Maximum 
      Supply Ckt. Overcurrent 
 Elec.  Rated Conductor  Protective 
 Specs.  Amps  Ampacity  Device
 115/60/1  22  30  30 
 208/60/1  12  15  15 
 240/60/1  11  15  15 
 208/60/3  6  15  15 
 240/60/3  6  15  15 
 480/60/3  3  15  15 
 575/60/3  3  15  15
Jordan Station, Ontario, Canada L0R 1S0
•
800/263-5798
•
Capacities
 Racks per hr. (NSF rated)  55 
 Wash tank US gal. 
(imp. gal./liters)  9 (7.5/34)
Wash motor horsepower 
Water consumption
 Gal. per hr. (max. use) 
US gal. (imp. gal./liters) 66 (55/248)
 Gal. per rack 
US gal. (imp. gal./liters)  1.2 
(0.96/4.4)
Temperatures °F/°C
 Wash  140/60 
 Rinse  140/60
Heating
 Tank heat, electric (kW)  4.7
Time cycle in seconds
 Wash  45 
 Dwell  1 
 Rinse  14 
 Total cycle  60
Warning: Plumbing and electrical connection 
should be made by qualified personnel who will 
observe all the applicable plumbing, sanitary and 
safety codes and the National Electrical Code.
Plumbing Note: Because of the variation in housesupplied water and steam pressure, pressure 
regulating valves (PRV’s) for incoming water 
and steam supply are needed. The PRV’s can be 
purchased from Champion or obtained locally.
Note: Water Hammer Arrestor (meeting ASSE-1010 
standard or equivalent) to be supplied (by others) in 
common water supply line at service connection.
Fax: 905/562-4618 
•