Champion D-H1T General Manual

Project Item No. Quantity
DH1T GAS HEATED DOORTYPE
STANDARD FEATURES
• Dual NSF listing as a dishwasher and pot, pan, utensil washer
• Automatic tank fill
• Automatic drain valve
• Adjustable mode/time selector switch
• Door activated cycle start
• One gas heating system for boosting the final rinse and tank heat
• Low-water tank heat protection
• 2-Hp pump motor
• Stainless steel pump impeller
• Door safety switch
• Interchangeable upper and lower spray arms
• Vented wash chamber design
• Detergent/chemical connection provisions
• Single point electrical connection (see chart)
• Vent fan control switch
Gas
DH1T
Gas Heated Door-type
Extended Hood
High Temperature Dishwasher
OPTIONS & ACCESSORIES
 Corner Model
 Drain Tempering Kit
(1M) 9/10 Printed in U.S.A.
CH079
Dual Certified!
SPECIFIER STATEMENT
Specified unit will be Champion Industries model D-H1T door type extended hood, gas tank heat, high temperature dishwashing machine.
Features include automatic tank fill, automatic drain valve, 2 Hp drip-proof pump motor, gas tank heat, interchangeable upper and lower spray arms, door activated start cycle, dual NSF Certified as both dishwasher and potwasher.
1 year parts and labor warranty.
Champion Industries, Inc.
3765 Champion Blvd., Winston-Salem, NC 27105
Tel: 336/661-1556 Fax: 336/661-1979
www.championindustries.com
2 HP
12-1/2"
[318]
11"
[279]
34"
[864]
27"
[686]
1A
3A
A A
2-11/16"
[68]
19-7/8"
[505]
1A
3A
Clearance
Door
Up
Hatco
Gas Booster
Mod. # Pmg-100
2
4
8-1/2"
[216]
10-1/4"
[260]
7-1/8" [181]
1B
31-3/8"
[797]
25-7/16"
[646]
13-1/4"
[337]
25-1/4"
[641]
67-7/16"
[1,713]
19-5/8"
[498]
5
3B
Up
2 HP
12-1/2"
[318]
11"
[279]
34"
[864]
27"
[686]
1A
3A
A A
2-11/16"
[68]
19-7/8"
[505]
1A
3A
Clearance
Hatco
Gas Booster
Mod. # Pmg-100
2
4
8-1/2"
[216]
10-1/4"
[260]
7-1/8" [181]
1B
31-3/8"
[797]
25-7/16"
[646]
13-1/4"
[337]
25-1/4"
[641]
67-7/16"
[1,713]
19-5/8"
[498]
5
3B
Door
87" [2,210]
27"
[686]
Clearance
[1,713]
67-7/16"
34"
[864]
[318]
12-1/2"
11"
[279]
1A
3A
Front View
DH1T
Extended Hood
Gas Heated Door-type
Dimensions shown in inches [mm]
Door
92-1/2"
[2,350]
Removal
High Temperature Dishwasher
Gas
Length between table connections: 25-3/4"
Shipping weight crated: 775 lbs.
Details, Dimensions & Connections
2-1/8" [54]
7-1/4" [184]
20-7/8"
1-1/4" [32] Roll
[530]
[616]
24-1/4"
[29]
1-1/8"
Hatco
Typical Table Construction
Gas Booster
Mod. # Pmg-100
25-7/16"
[797]
2 HP
[498]
19-5/8"
[646]
7-1/8" [181]
[216]
8-1/2"
[260]
10-1/4"
3B
5
Minimum
Overcurrent
Minimum
Supply Ckt.
25-1/4"
[337]
13-1/4"
1B
4
2
Device
Protective
Ampacity
Conductor
[641]
* Booster shown is the PMG100. Contact factory for
PMG60 drawings & electrical information.
Side View
Amps
Rated
Electrical Connection
Utilities
1
A Machine connection (See Box)
Hot Water
B Gas Booster connection requires 15 Amps @ 120/60/1
3/4” NPT hot water 140°F for 40°F rise booster.
3/4” NPT hot water 110°F for 70°F rise booster.
Flow pressure 20-22 psi.
2
Drain
A 2” OD machine connection
B 3/4” NPT relief valve to open drain
3
Natural Gas Connection
40°F rise - 58,000 BTU/hr.
4
70°F rise - 105,000 BTU/hr.
Gas Flue Exhaust
PMG-60 requires 1/2” NPT.
PMG-100 requires 3/4” NPT.
5
4” Dia. Rear of booster
Note: The booster and machine come fully interplumbed
complete with a blended phosphate water treatment
system, pressure regulating valve, water hammer arrestor,
ASME temperature and pressure relief valve, drain valve,
circulator pump, and temperature gauges installed and
ready for connection to your water supply.
Machine Load Amps
Elec.
Specs.
208/60/1 15 20 20
240/60/1 14 20 20
208/60/3 8 15 15
240/60/3 7 15 15
480/60/3 4 15 15
575/60/3 3 15 15
Loading...