• Built-in 40°F/22°C rise stainless steel electric
booster (DHB only)
• Vent fan control
DHB/DH1
Door-type High Temperature
Dishwashing Machine
OPTIONS & ACCESSORIES
Sheet pan rack
Electric:
Steam coil tank heat
Steam injector tank heat (DHB only)
Steam: 40°F/22°C - 70°F/39°C rise
(built-in) (DHB only)
Corner operation
2674 N. Service Road,
Jordan Station, Ontario, Canada L0R 1S0
Tel: 800/263-5798 Fax: 905/562-4618
(1M) 9/10 Printed in U.S.A.
CH105
70°F/39°C rise (built-in) (DHB only)
SPECIFIER STATEMENT
Specified unit will be Champion model D-HB/D-H1 high
temperature dishwashing machine with built-in,
stainless steel booster heater (DH1 without booster).
Features top mounted control cabinet, balanced door-lift
with door safety switch, 40°F/22°C rise, built-in SST booster
(DHB only), interchangeable stainless steel wash and rinse
arms, 55 racks/hr., 0.86 US gals/rack, single point electrical
connection. Constructed of Type 304 SST.
1 year parts and labor warranty.
Champion Industries, Inc.
3765 Champion Blvd., Winston-Salem, NC 27105
Tel: 800/532-8591 Fax: 336/661-1979
www.championindustries.com
Page 2
FRON
T
5-1/4" [133] min
5-1/4" [133] min
20-1/2" [521]
Inside Tracks
DHB/DH1
Door-type High Temperature
Dishwashing Machine
Dimensions shown in inches and [millimeters]
Details, Dimensions & Connections
AA
60-1/2" [1537]
8-7/8" [225]
8-3/4" [222]
Length between table connections: 26"/660mm
92-1/2" [2302]
Door
Removal
86" [2184]
Doors
Up
67-1/2" [715]
Mach.
Height
Volume crated: 46 cu.ft.
Shipping weight crated: 350 lbs./158kg
27" [686]
Clearance
34" [864]
Load
Height
2HP
1
26" [660]
4" [102]
1
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 800/263-5798 • Fax: 905/562-4618
9-1/4"
[229]
3
1
Front
13"
[330]
3
2
13-3/4"
[343]
2
2
20-1/8"
[511]
Inside Tracks
5-1/4" [133] min
Straight Through
Wash Pump 2 Hp
2-7/8" [73]
Front
Front View
Corner Configuration
Page 3
DHB/DH1
Door-type High Temperature
Dishwashing Machine
Utilities
1
Electrical (See Box)
2
Hot Water (DHB)
3/4" NPT hot water 140°F/60°C min for
40°F/22°C rise booster. 3/4" NPT hot water
110°F/43°C min for 70°F/39°C rise booster. Flow
pressure 20-22 psi. (138-151kPa)
Hot Water (DH1)
3/4" NPT 180ºF/82ºC hot water connection.
Flow presure 20-22 ps, (138-151 kPA
3
Drain
2" O.D. connection. Max. flow rate
15 US gpm. (12imp.gpm/54/Lpm
For Electrical Heat
Elec.
Specs.
208/60/1738080
240/60/1819090
208/60/3415050
240/60/3465050
480/60/3202525
575/60/3162020
For Electrical Heat
Elec.
Specs.
208/60/3586060
240/60/3667070
480/60/3303535
575/60/3253030
Typical Table Construction
1-1/8"
[29]
Rated
Amps
Rated
Amps
30"
[762]
D-HB
w/40°F/22°C Rise Booster
Minimum
Supply Ckt.
Conductor
Ampacity
D-HB
w/70°F/39°C Rise Booster
Minimum
Supply Ckt.
Conductor
Ampacity
1-1/2" [32] Roll
21-3/8"
[543]
Minimum
Overcurrent
Protective
Device
Minimum
Overcurrent
Protective
Device
7-1/4"
[184]
SPECIFICATIONS
Capacity
Racks per hr. (NSF rated) 55
Wash tank US gal. (imp. gal/liters) 9 (7.5/34)
Motor horsepower 1
Water consumption
Gal. per hr. (max. use) US gal. (imp. gal/liters) 49 (41/186)
Gal. per rack (US gal. (imp. gal/liters) .86 (0.74/3.4)
Temperatures °F/°C
Wash 150/66
Rinse 180/82
Heating
Tank heat, electric, (kW) 5.2
Tank heat, steam (lbs.per hr.
required at 15 psi flow pressure) 25
DHB
only
Electric booster (kW required for 40°F/22°C rise) 9
Electric booster (kW required for 70°F/39°C rise) 13
Steam booster (internally mounted)
(lbs. per hr. required for 40°F/22°C rise) 50
Steam booster (internally mounted)
(lbs.per hr. required for 70°F/39°C rise) 65
Time cycle in seconds
Wash 40
Rinse 8
Dwell 12
Total cycle 60
For Electric Heat
D-H1 Electrical Power Requirements
Minimum
Supply Ckt.
Elec.
Specs.
115/60/1*486060
208/60/1374040
240/60/1404545
208/60/3202525
240/60/3222525
480/60/391515
575/60/371515
*3kW wash tank heat
Rated
Amps
Conductor
Ampacity
Minimum
Overcurrent
Protective
Device
Warning: Plumbing and electrical connection
should be made by qualified personnel who
will observe all the applicable plumbing,
sanitary and safety codes and the National
Electrical Code.
Plumbing Note: Because of the variation
in house-supplied water and steam
pressure, pressure regulating valves (PRV’s)
for incoming water and steam supply are
needed. The PRV’s can be purchased from
Champion or obtained locally.
Note: Water Hammer Arrestor (meeting ASSE1010 standard or equivalent) to be supplied
(by others) in common water supply line at
service connection.
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.