Chamberlain Ultra RX ULTRX900R User Manual

Page 1
Carton Inventory
Overview
The Ultra RX - Extreme Range Receiver has a 10-24Vac/Vdc operation with low power consumption (150 ua). The Receiver has 4 Channels, 2 Transistors and 2 Relays. The Receiver can control up to 4 devices.
1
Model ULTRX900R
Ultra RX - Extreme Range Receiver
Setup
1 3 2 4 5 6 7 8 9 10 11 12 13
10-24 Vac
1 3 2 4 5 6 7 8 9 10 11 12 13
-
+
10-24 Vdc
NOTE: Polarity does not matter.
Power Connections
Relay Outputs
The Receiver has 2 Relays and 2 Transistor (Open Collector) Outputs to control up to 4 devices. Higher Amperage (10 amp) applications that are directly controlled, should use Relay Channels 1 and 2.
Relay 1: 11: Common 12: Ch 1 Normal Open 13: Ch 1 Normal Closed
1 3 2 4 5 6 7 8 9 10 11 12 13
Relay 2: 8: Common 9: Ch 2 Normal Open 10: Ch 2 Normal Closed
Lower Amperage (500 ma or lower) applications that are indirectly controlled, should use Transistor Output Channels 3 and 4.
Channel 3:
Terminal 6
Channel 4:
Terminal 4
1 3 2 4 5 6 7 8 9 10 11 12 13
1 3 2 4 5 6 7 8 9 10 11 12 13
1 3 2 4 5 6 7 8 9 10 11 12 13
Dipswitch Settings
NOTE: If using the Receiver with a Gate Control Unit (GCU) proceed to Program with Gate Control Unit (GCU).
NOTE: The Dipswitches on the Receiver can be accessed by removing the screw on the bottom of the Receiver.
Ensure the Receiver does not have power. Set Dipswitch #1 to the ON position.
NOTE: These steps apply only if more than one Receiver is being used.
Step 1: Ensure the Receiver does not have power. Set Dipswitch #1 to the ON position in each Receiver.
Step 2: Set the Identity of each additional Receiver by changing the Dipswitches as shown in the chart below.
Receiver ID Switch #2 Switch #3
2 ON OFF 3 OFF ON 4ON ON
Additional Receivers
NOTE: Do not connect power until instructed to do so.
Page 2
2
Output Timing
Dipswitch Dipswitch Time
#4 #5
OFF OFF 0.5 Sec ON OFF 5 Sec OFF ON 1 Min ON ON Toggle
Channel 1:
Dipswitch Dipswitch Time
#6 #7
OFF OFF 0.5 Sec ON OFF 5 Sec OFF ON 1 Min ON ON Toggle
Channel 2:
Program
NOTE: If the Receiver will be programmed with a GCU or an accessory proceed to Program with GCU or Program Accessories. The following steps apply only if the Receiver will be used by itself.
Step 1: Ensure the Receiver does not have power and Dipswitch #1 is set to the OFF position.
NOTE: If Receiver is in this Mode, there can be no other 900 Mhz units in the network.
Step 2: Connect power (as shown in Setup: Power Connections).
Step 3: Within 15 seconds, press and hold a button on a remote control transmitter. The receiver will buzz indicating programming is successful.
Additional Remote Control Transmitters:
To program additional remote control transmitters, repeat Step 3 above with each remote control transmitter (within 10 seconds of each other) or repeat Steps 1-3.
When all the remote control transmitters have been programmed, wait 15 seconds for the Receiver to leave Learn Mode. The Receiver will buzz twice indicating it is ready for use.
Output Timing
Dipswitch Dipswitch Time
#4 #5
OFF OFF 0.5 Sec ON OFF 5 Sec OFF ON 1 Min ON ON Toggle
Channel 1:
Dipswitch Dipswitch Time
#6 #7
OFF OFF 0.5 Sec ON OFF 5 Sec OFF ON 1 Min ON ON Toggle
Channel 2:
Dipswitch Dipswitch Time
#2 #3
OFF OFF 0.5 Sec ON OFF 5 Sec OFF ON 1 Min ON ON Toggle
Channel 3:
Dipswitch Time
#8
OFF 0.5 Sec ON 5 Sec
Channel 4:
Program with Gate Control Unit (GCU)
NOTE: The Dipswitches on the Receiver can be accessed by removing the screw on the bottom of the Receiver.
Page 3
3
Door Strike or Magnetic Lock
Step 1: Connect relays (as shown in Setup: Relay
Outputs and the charts below).
NOTE: If a Door Strike is used, a separate power supply is required. If a Magnetic Lock is used, use the Normally Closed connections (see below).
132 4567891011
DC
AC
+
-
COM
N/C
Door Strike
Transformer/ Power Supply
Optional external power input 10-24 Vac or DC
Door Strike- Normally Open (N/O) Connection
N/O
1324567891011
+
-
COM
N/C
Magnetic Lock
Transformer/ Power Supply
Magnetic Lock- Normally Closed (N/C) Connection
DC
AC
Optional external power input 10-24 Vac or DC
N/O
GCU
GCU
Program Accessories
Single Pushbutton Control (WPB1LM)
Step 1: Connect relays (as shown in Setup: Relay
Outputs).
Step 2: Connect power (as shown in Setup: Power Connections).
Step 3: Press and Release the Learn button on the Pushbutton Control.
The Receiver will buzz and the LED will blink 3 times indicating programming is successful. If the memory in the Pushbutton Control needs to be cleared, press the Learn button until a tone is heard.
Refer to the Pushbutton Control manual for mounting and operating instructions.
Gate Access Panel (GAPLM)/Keypad
Step 1: Connect relays (as shown in Setup: Relay
Outputs).
Step 2: Connect power (as shown in Setup: Power Connections).
Step 3: On the GAPLM or Keypad, enter Master PIN Number, followed by the Receiver Identity (1-4) as determined in Setup: Additional Receivers.
The Receiver will buzz and the LED will blink 3 times indicating programming is successful.
Refer to the GAPLM/Keypad manual for mounting and operating instructions.
1
2 3
4
5 6
7 8 9
0 #
ac
OR
Installation
Step 1: Reattach cover with screw.
Step 2: Mount the Receiver with
the Terminal Block at the bottom and the antenna hanging straight down.
NOTE: Metal surfaces can shorten the range of the Receivers. If mounting on a metal surface and long range is required, use a non-metallic spacer to move the Receiver away from the metal surface.
Page 4
© 2007, The Chamberlain Group Inc.
114A3549 All Rights Reserved
NOTICE: To comply with FCC and or Industry Canada rules (IC), adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FOR TECHNICAL SUPPORT DIAL OUR TOLL FREE NUMBER:
1-800-528-2806
www.liftmaster.com
Operation
GAPLM/Keypad
On the GAPLM/Keypad enter any valid PIN Number followed by Identity (1-4). If the Receiver gets a request a success tone is heard. If a fail tone is heard, check the batteries in the GAPLM/Keypad or try again.
Single Pushbutton Control (WPB1LM)
Push the button on the Pushbutton Control. If the Receiver gets a request a success tone is heard. If a fail tone is heard, check the batteries in the Pushbutton Control or try again.
Clear Memory
When the Receiver has power, press the Learn button until the LED blinks a total of 8 times.
ON
1234567
Loading...