CENTRAK PROBE-BASED TEMPERATURE
SENSOR TAGRIT-735P
Covers ranges from -200C to +50C
●
●
0.75C accuracy (0.5C typical)
●
Customizable reporting rates – down to 12 seconds
Low power consumption for long battery life (4 years with 1 minute reporting rate)
●
●
NIST traceable calibration available
●
Button for event reporting
●
Integrates with CenTrak RTLS
Hospitals have a critical need for wireless monitoring of environmental fluctuations. They
require reliable real time monitoring and alerting capabilities as well as comprehensive
records of sensor data for reporting and analysis purposes. CenTrak’s advanced
temperature sensing technology was developed to meet those needs.
The IT-735 is a probe-based temperature sensing tag that has the ability to monitor a wide
range of temperatures, from cryogenic (-200C) to room temperature (+50C), reliably and
accurately with customizable reporting rates down to 12 seconds at 0.75C accuracy. It is
available for use with three specific temperature range probes : -20C to +50C (ITA-781),
-100 to -20C (ITA-782), and -200 to -100C (ITA-783)
The IT¬735 Tag creates a cost effective way to improve patient care as well as provide
automated and detailed reports for any time period. In conjunction with the CenTrak RTLS
this single Tag can be used to track, locate, identify and ensure correct temperature levels
and can generate alerts via email/SMS when the temperature goes above or below set
parameters. The system can also provide temperature logs which eliminate human error
and the cost of manual temperature documentation.
CenTrak, Inc.
5 Caufield Place, Suite 102
Newtown, PA 18940
t: 215-860-2928
e: sales@centrak.com
www.centrak.com
Tags send temperature readings in intervals specified by the user (e.g., every one minute). The
battery powered tags will even continue to monitor temperature and send a local alert in the
event of a power outage. Tags provide an automated and accurate solution that improves
regulatory compliance and saves time so that staff can focus on patient care and safety.
About CenTrak Technology
CenTrak’s core RTLS differs from legacy technologies in its use of a patented combination of
second-generation infrared (Gen2IR™) and active RFID technology called DualTrak. Battery
powered Monitors transmit a unique room number using Gen2IR which is received by any tag
in that room. The tag communicates the room number and its own unique ID via RF to the
CenTrak Location Server using a hospital’s existing wired or Wi-Fi network, where it can be
accessed in real-time by hospital personnel and integrated with third party solution providers.
Like light, Gen2IR will not pass through walls and does not suffer from traditional infrared
line-of-sight limitations. Therefore, when a tag reads a room number, there are no errors.
This is certainty-based RTLS. Unlike estimation-based information, certainty-based location
data can be used by hospitals to make important improvements to process flow and
automate decision making. Most healthcare workflow improvements can only be realized
when the location data is certainty-based.
WARNING: This guide is in draft form and can be changed without notice at any time by CenTrak. Please
contact CenTrak prior to commercial use to receive all the necessary latest information about the system.
© CenTrak 2010. All Rights Reserved • DualTrak and CenTrak is a trademark of CenTrak, Inc. • Proprietary and Confidential Information • 12/1/10
902-928 MHz (Model # IT-735)
8M codes
> 300 feet
2 uW (Average)
1 button, LED, low battery
FCC Operating Frequency Range
868-870 MHz (Model # ITEU-735)
CE Operating Frequency Range
Operation
Group ID codes
Outdoor transmission range
Field strength
Smart Tag features
YES
Motion Sensor
ITA-786
ITA-787
ITA-751
ITA-752Double sided adhesive
Thermal vial holder
Probe holder for air
temperature measuring
3M VHB adhesive (0.64 mm)
ITA-753
Screw attachment w/ adhesive pad
Operating temperature (Tag)
Storage temperature (Tag)
+10C to +40C
-25 C to +80 C
Battery type
Smart tag feature Low battery indication
Lithium CR2450
Environmental
Power
Probe temperature ranges
Thermal Vial
-20C to +50C (ITA-781)
-100 to -20C (ITA-782)
-200 to -100C (ITA-783)
ITA-785
Attachment Options
Case length
Case height
Case width
1.5 in (38.48mm)
1.98 in (50.36 mm)
0.94 in (24 mm)
Case weight (with battery)
Construction
1.10 oz. (34.02g)
Durability Tough, impact resistant and
temperature stable
ABS & Poly Carbonate mixture
Tag Dimensions
Note: Must use CenTrak Disinfection procedure. Other methods may void product warranty.
Tag cleaning method
Wipe Cleaning Method Only.
See CenTrak Tag Disinfection Guide for Instructions
Cleaning
CENTRAK PROBE-BASED TEMPERATURE SENSOR
TAG IT-735 TECHNICAL SPECIFICATIONS
CenTrak, Inc.
5 Caufield Place, Suite 102
Newtown, PA 18940
t: 215-860-2928
e: sales@centrak.com
www.centrak.com
This component complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) The device may not cause harmful interference,
and 2) this device must accept any interference received, including interference that may cause undesired operation. Modifying or tampering with the
transceiver’s or receiver’s internal components can cause a malfunction, invalidate the warranty, and will void FCC authorization to use these products. This
product or its systems are covered by one or more of the following U.S. patents: 5,917,425 , 7,061,428 , 7,378,964
© CenTrak 2010. All Rights Reserved • DualTrak and CenTrak is a trademark of CenTrak, Inc. • Proprietary and Confidential Information • 12/1/10