CDI Torque SPLIT BEAM CLICK TORQUE WRENCH User Manual

This torque wrench as calibrated at the factory, is certified to meet the current ASME specification. Additionally, all wrenches are calibrated on a torque standard traceable to the National Institute of Standards and Technology (N.I.S.T.).
CONvERsION TAbLE
To Convert Multiply From To By
in. oz. in. lb. 0.06250
FOR YOUR PERMANENT FILECERTIFICATION
WRENCH MODEL NUMBER:
WRENCH SERIAL NUMBER:
For Warranty Claims, Contact CDI Torque Products
at (626) 965-0668.
OPERATION MANUAL
sPLIT bEAM CLICk
TORQUE WRENCH
in. lb. in. oz. 16
in. lb. ft. lb. 0.08333
in. lb. cmkg 1.15212
in. lb. mkg 0.01152
in. lb. Nm 0.11298
in. lb. dNm 1.12984
ft. lb. in. lb. 12
ft. lb. mkg 0.13825
ft. lb. Nm 1.35581
dNm in. lb. 0.88507
dNm Nm 0.1
Nm dNm 10
Nm cmkg 10.1971
Nm mkg 0.10197
Nm in. lb. 8.85074
Nm ft. lb. 0.73756
cmkg in. lb. 0.86796
LIMITED WARRANTY
The CDI Split Beam Click Torque Wrench is backed by a one year warranty. This warranty covers manufacturer defects and workmanship. The warranty excludes misuse, abuse and normal wear and tear. Exclusion is not allowed in some states and may not apply. This warranty gives you specific legal rights, and you may have other rights, which vary from state to state.
IMPORTANT ENVIRONMENTAL NOTES:
1. This equipment may contain hazardous materials which can be harmful to the environment.
2. Do not dispose of this equipment as municipal waste. Return it to the distributor or a designated collection center. Thank you for caring about our environment!
cmkg Nm 0.09806
mkg in. lb. 86.7961
mkg ft. lb. 7.23301
mkg Nm 9.80665
19220 SAN JOSE AVENUE • CITY OF INDUSTRY, CA 91748 • USA
(626) 965-0668
Find other ne torque products at WWW.CDITORQUE.COM
Form 20-301-CDI 6/2010 Rev. N/C
sAFETY MEssAGEs
WARNING
Read operation manual completely before using torque instrument and store for future reference.
ADJUsTMENTs OF
TORQUE sETTINGs
SET KNOB
APPLY FORCE
SCALE WINDOW
Wear safety goggles-both user and bystanders
• An out of calibration torque wrench can cause part or tool breakage
• Periodic re-calibration is necessary to
maintain accuracy
• Do not exceed rated torque as
overtorquing can cause wrench or part failure
• Do not use torque instrument to break
fasteners loose
• Do not use cheater extension on the
handle to apply torque
• Broken or slipping tools can cause
injury.
CAUTION - RATCHET HEAD
Ratchet mechanism may slip or break if dirty, mismatched or worn parts are used, or direction lever is not fully engaged. Ratchets that slip or break can cause injury.
MAINTENANCE / sERvICE
1. The torque wrench’s internal mechanism is
permanently lubricated during assembly. Do not
attempt to lubricate the internal mechanism.
SET MARK
LOCK LEVER
1. Pull back on the lock lever to unlock the set knob.
2. With the set knob turned to the lowest value, turn the knob clockwise to the desired value indicated at the set mark. If the value is exceeded, back off and approach the proper seting from the low side.
3. Close the lock lever to lock the set knob at the torque setting.
4. To torque fastener, keep hand centered on the handle, apply a slow steady force in the clockwise direction until a click/impulse is heard or felt. Stop pulling and allow the wrench to reset.
RELEASE FORCE TO RESET
UsE OF ExTENsIONs
AND ADAPTERs
When using an extension or adapter (increasing the effective length of the torque wrench) the output torque value will change. To calculate the new torque output of the wrench use the following formula:
TA x L
TW =
TA = Torque exerted @ end of adapter L = Distance between square drive and hand position TW = Wrench scale reading A = Length of adapter or extension
TA TW
A
L + A
L
2. Clean torque wrench by wiping. Do not immerse.
3. Store torque wrench in protective tube at its lowest
torque setting. Do not force handle below lowest
setting.
A number of variables can affect torque accuracy. These include the length of an adapter or extension, length of the wrench and variations in hand position on the wrench will affect the accuracy of the above calculation.
Loading...