This torque wrench as calibrated at the factory, is
certified to meet the current ASME specification.
Additionally, all wrenches are calibrated on a torque
standard traceable to the National Institute of
Standards and Technology (N.I.S.T.).
CONvERsION TAbLE
FOR YOUR PERMANENT FILECERTIFICATION
WRENCH MODEL NUMBER:
WRENCH SERIAL NUMBER:
OPERATION MANUAL
DIAL TORQUE WRENCH
sINGLE sCALE
MEMORY NEEDLE
To Convert Multiply
From To By
in. oz. in. lb. 0.06250
in. lb. in. oz. 16
in. lb. ft. lb. 0.08333
in. lb. cmkg 1.15212
in. lb. mkg 0.01152
in. lb. Nm 0.11298
in. lb. dNm 1.12984
ft. lb. in. lb. 12
ft. lb. mkg 0.13825
ft. lb. Nm 1.35581
dNm in. lb. 0.88507
dNm Nm 0.1
Nm dNm 10
Nm cmkg 10.1971
Nm mkg 0.10197
For Warranty Claims, Contact CDI Torque Products
at (626) 965-0668.
LIMITED WARRANTY
The CDI Dial Torque Wrench Single Scale Memory
Needle is backed by a one year warranty. This
warranty covers manufacturer defects and
workmanship. The warranty excludes misuse,
abuse and normal wear and tear. Exclusion is not
allowed in some states and may not apply. This
warranty gives you specific legal rights, and you
may have other rights, which vary from state to
state.
IMPORTANT ENVIRONMENTAL NOTES:
1. This equipment may contain hazardous materials which can be
harmful to the environment.
2. Do not dispose of this equipment as municipal waste. Return it
to the distributor or a designated collection center.
Thank you for caring about our environment!
Nm in. lb. 8.85074
Nm ft. lb. 0.73756
cmkg in. lb. 0.86796
cmkg Nm 0.09806
mkg in. lb. 86.7961
mkg ft. lb. 7.23301
mkg Nm 9.80665
19220 SAN JOSE AVENUE • CITY OF INDUSTRY, CA 91748 • USA
(626) 965-0668
Find other ne torque products at WWW.CDITORQUE.COM
Form 20-220SS-CDI
6/2010 Rev. B
sAFETY MEssAGEs
WARNING
Read operation manual completely
before using torque instrument and
store for future reference.
Wear safety goggles-both user and
bystanders
• An out of calibration torque wrench
can cause part or tool breakage
• Periodic re-calibration is necessary to
maintain accuracy
• Do not exceed rated torque as
overtorquing can cause wrench or part
failure
• Do not use torque instrument to break
fasteners loose
• Do not use cheater extension on the
handle to apply torque
• Broken or slipping tools can cause
injury.
CAUTION - RATCHET HEAD
Ratchet mechanism may slip or break
if dirty, mismatched or worn parts are
used, or direction lever is not fully
engaged. Ratchets that slip or break
can cause injury.
MAINTENANCE / sERvICE
1. The torque wrench’s internal mechanism is
permanently lubricated during assembly. Do not
attempt to lubricate the internal mechanism.
ADJUsTMENTs OF
TORQUE sETTINGs
PUSHER
NEEDLE
(ORANGE)
MEMORY
FOLLOWER
NEEDLE
KNOB
MEMORY
FOLLOWER
NEEDLE
(BLUE)
BEZEL
FOLLOWER NEEDLE DIAL
sETTING MEMORY
FOLLOWER NEEDLE
ON sINGLE sCALE MODEL
Before using all models of dial torque wrenches, it is
strongly suggested to cycle/operate them 3 times at
full scale in the torque direction in which they will be
used. Dial torque wrenches must always be zeroed
before use.
To set orange pusher & blue follower needle for righthand (CW) torquing:
1. Turn bezel in left-hand (CCW) direction until, blue
memory follower needle contacts orange pusher
needle.
2. Continue to turn bezel left-hand (CCW) until blue
memory follower needle is lined up with zero (0) of
outer graduation on portion of dial for IN.LB., FT.LB.,
METRIC readings.
3. Apply force on the wrench handle until blue follower
needle reaches desired torque. When force is released
orange pusher needle will return to zero and blue
memory follower needle will remain at torque applied.
4. For repetitive torque operations (once the zero
has been set as instructed above), the blue memory
follower needle can be returned to zero by use of the
follower needle knob. It is ready for the next operation.
5. IMPORTANT - When using the memory feature
always make sure that the blue follower memory
needle is on zero before torquing.
UsE OF ExTENsIONs
AND ADAPTERs
When using an extension or adapter (increasing the
effective length of the torque wrench) the output
torque value will change. To calculate the new torque
output of the wrench use the following formula:
TA x L
TW =
L + A
TA = Torque exerted @ end of adapter
L = Distance between square drive and hand position
TW = Wrench scale reading
A = Length of adapter or extension
TA TW
A
L
2. Clean torque wrench by wiping. Do not immerse.
3. Store torque wrench in protective tube at its lowest
torque setting. Do not force handle below lowest
setting.
A number of variables can affect torque accuracy.
These include the length of an adapter or extension,
length of the wrench and variations in hand position
on the wrench will affect the accuracy of the above
calculation.