Casio TQ-3591 User Manual

Vibranett Alarm Clock
Manual
ENGLISH: Analogue alarm clock for under-pillow vibrator ......page 2
NEDERLANDS: Analoge wekker met kussenvibrator ...............Pag. 4
NORSK: Analog vekkerklokke for putevibrator ...................... side 6
SVENSKA: Analog väckarklocka för kuddvibrator .................... sid 8
Ordering number: 200 30 73
2
Analogue alarm clock for under-pillow vibrator
Our analogue alarm clock alerts the user with both sound and an under-pillow vibrator. It can be used as a stand-alone wake-up system or together with our alerting system Lynx.
Batteries
The alarm clock is powered by one 1.5 volt battery, size C. The under-pillow vibrator is pow­ered by mains current. In addition, there is an alkaline back-up battery (9 volt) for the under­pillow vibrator in the event of a power failure. Always use mains power for the under-pillow vibrator (a green LED should light up on the clock face) so as not to drain the back-up battery. NOTE: You should change the back-up battery once a year, see instructions on next page.
Connecting the under-pillow vibrator
To Lynx Tactum: Connect Tactum’s under-pillow vibrator to the Tactum charger. Then, connect the alarm clock to the charger, using the enclosed connection cord.
As a stand-alone wake-up system: Connect the under-pillow vibrator into the socket on the backside of the alarm clock.
To Lynx Flash: Connect the under-pillow vibrator to Lynx Flash. Then, connect the alarm clock to Lynx Flash, using the enclosed connection cord.
Wake-up
At wake-up time, the alarm clock will ring and the under-pillow vibrator starts vibrating, until you turn it off.
Technical data
Power supply: 230 V AC 50-60 Hz. Batteries: Alarm clock: 1 x 1,5 V (size C). Service life >3 years.
Back-up battery for under-pillow vibrator: 1 x 9 V (6LR61). Service life 1 year. Under-pillow vibrator: 9-24 V DC (80 mA).
Any issues relating to the EU Medical Device Directive 93/42/EEC should be directed to AB Transistor Sweden.
Turn to set wake­up time. Pull and turn to set time.
Battery lid for clockwork.
Screws, to open clock and change back-up battery of under-pillow vibrator (two more screws under the battery lid).
Connection to under-pillow vibrator.
Connection to mains outlet.
Alarm on/off.
Snooze, repeats alarm every 4th minute.
Green LED. Indicates mains adapter connected.
3
Cleaning and maintenance
Use a vacuum cleaner with a soft brush to clean the product on the outside. Use a damp cloth to wipe it on the outside. Never use cleaning products or solvents. From time to time check that the cables and connections are intact. The batteries last for at least 3 years. The back-up battery should always be changed once a year to ensure the clock will operate if there is a power failure.
Repairs
If your product malfunctions, it must be repaired by a qualified technician. If your product requires service, please contact your hearing care professional for assistance.
Waste disposal
This product contains electrical or electronic equipment and should be disposed of carefully in the interest of your safety and the environment. Please contact your local hearing care professional concerning disposal of the product.
General precautions
• The back-up battery should always be changed once a year to ensure the clock will operate if there is a power failure.
• Radiation from low-emitting equipment (burglar alarms, room surveillance systems, radio equipment, mobile telephones, etc) will not damage the device.
• Warning: External devices connected to the product must be safe according the requirements of EN 60601-1-1, EN 60335-1 or EN 60065, as appropriate.
Troubleshooting
Type of fault Cause Action
The clock has stopped. Flat battery. Replace the old battery with a new 1.5 volt
Size C battery.
The under-pillow vibra­tor is not working.
1. The under-pillow vibrator is not connected to the clock.
2. The mains lead is not connected and the back-up battery is flat.
1. Connect the under-pillow vibrator to the clock.
2. Insert the mains cable and immediately change the back-up battery.
The clock does not ring. The clock’s alarm is set to OFF. Set the clock’s alarm to ON.
Changing the back-up battery
1. Disconnect the mains cable from the clock.
2. Unscrew the four corner screws on the rear of the clock.
3. Pull out and remove the alarm set knob.
4. Carefully lift off the clock’s rear cover so that you do not damage the cables.
5. Undo the 9 volt battery from the Velcro and disconnect the snap connector.
6. Connect the new battery in the same manner.
NOTE: Remember to reconnect the mains cable to the clock so that the green LED on the clock face lights up.
4
NEDERLANDS
Analoge wekker met kussenvibrator
Onze analoge wekker met kussenvibrator geeft geluidssignalen en activeert de kussenvibrator. De wekker kan zowel vrijstaand worden gebruikt als in combinatie met ons waarschuwingssysteem Lynx.
Werking wekker
Het uurwerk loopt op een 1,5 V (C) batterij. De kussenvibrator en de wijzerplaatverlichting worden
aangesloten op het lichtnet via de adapter aansluiting, welke zich aan de zijkant van de wekker bevindt
(zie tekening). Het aansluitpunt voor de kussenvibrator vindt u aan de andere zijkant van de wekker. Een 9 V back-up batterij zorgt ervoor dat u ook gewekt wordt bij stroomuitval.
Wekker in combinatie met Lynx
In combinatie met Lynx Tactum dient u de kussenvibrator aan te sluiten op de lader van de Tactum. Sluit vervolgens de wekker aan op de lader via het meegeleverde verbindingskabeltje.
In combinatie met de Lynx Flitslamp dient u de kussenvibrator en de wekker beiden aan te sluiten
op de onderzijde van de flitslamp. Gebruik de meegeleverde verbindingskabel voor het aansluiten
van de wekker.
Wekken
Op het ingestelde tijdstip begint de wekker te zoemen en begint de kussenvibrator te trillen totdat
het alarm wordt uitgeschakeld.
Technische gegevens
Spanning: 230 V AC 50-60 Hz. Batterijen: Uurwerk: 1 x 1,5 V (C). Levensduur circa 3 jaar.
Back-up batterij t.b.v. kussenvibrator: 1 x 9V (6LR61). Ieder jaar vervangen. Trilkussen: 9-24 V DC (80 mA).
Alle zaken betreffende de EU-Richtlijn Medische Hulpmiddelen 93/42/EEG dienen gemeld te worden aan AB Transistor Sweden.
Alarm instelknop. Draaien om de wektijd in te stellen. Uittrekken en draaien om de tijd in te stellen.
Batterijdeksel voor batterij uurwerk.
Schroeven voor het openen van de wekker om de back-up batterij te vervangen.
Aansluiting kussenvibrator.
Aansluiting op het lichtnet.
Alarm aan/uit.
Sluimeren, het alarm wordt elke 4 minuten herhaald.
Groen indicatielampje geeft aan dat de netadapter is aangesloten.
Loading...