Cashco 8310HP User Manual

Vent to Atmosphere ­Leakage of Steam or Oil Indicates a Diaphragm Failure. (1/8" NPT)
DOUBLE DIAPHRAGM TOPWORKS
(“HP” V ARIA TION ONL Y)
TEMPORARY LITHO 08/96
8310HP-1+8
Loading Connection. (1/4" NPT)
DA TE
8310HP-1+6
SINGLE DIAPHRAGM TOPWORKS
ITEM NO. DESCRIPTION
1 BODY 2 BONNET 3 BOTTOM FLANGE 4 GUIDE BUSHING 5 STEM BUSHING 6 BODY GASKET 7 BODY STUD
8 BODY STUD NUT 10 UPPER SEAT RING 11 LOWER SEAT RING 12 VALVE PLUG ASSEMBLY
12.1 PLUG
12.2 STEM
12.3 PIN (GROOVE) 13 SPRING CHAMBER 14 DIAPHRAGM CASE 15 O-RING 16 BONNET NUT 17 PUSHER PLATE 18 PUSHER PLATE GASKET 19 STEM LOCK NUT
ITEM NO. DESCRIPTION
20 DIAPHRAGM 21 DIAPHRAGM GASKET 22 PRESSURE PLATE 23 LOWER PRESSURE PLATE 24 PRESSURE PLATE NUT 25 BODY SPACER 26 DIAPHRAGM SPACER 27 SPRING BUTTON 28 RANGE SPRING 29 FLANGE BOLT 30 FLANGE NUT 31 NAME PLATE 32 ADJUSTING SCREW 33 ADJ. SCREW LOCK NUT 34 SEAL WASHER 35 CLOSING CAP 36 CLOSING CAP GASKET 37 BLEEDER VALVE 38 PIPE NIPPLE 39 NEEDLE VALVE 53 O-RING
NB PB QB
INSTALLATION, OPERATING AND
MAINTENANCE INSTRUCTIONS
Install with arrow on body (1) pointing in direction of flow. Install an external sensing line (1/2" O.D. tubing min.) from the 3/8" NPT
connection in needle valve (39) to a point downstream, preferably at gauge location.
Install oil loading pressure sensing line to spring chamber (13) connec­tion.
Before disassembling the valve for maintenance work, always release the tension on the range spring (28) by turning the adjusting screw (32) coun­terclockwise.
For examination or replacement of diaphragms (20), remove spring cham­ber (13). Place wrench on flats of pusher plate (17). Remove nut (24), and pressure plate (22), then remove upper set of diaphragms (20), diaphragm spacer (26), body spacer (25), and lower set of diaphragms (20).
The diaphragm setting must be flush to ensure proper valve travel (with plug against the seat, adjust the pusher plate (17) so that the gasket (18) face of the pusher plate (17) is flush with the top of the case (14) flange and then tighten the stem lock nut (19) by holding upper flats on the pusher plate (17)).
STABILIZING NEEDLE VALVE – The needle valve (39) is shipped in a full open position. If the system is unstable due to pressure fluctuations, slowly close this valve (39) until system becomes stable. This valve (39) should never be in a fully closed position.
Turn handle of bleeder valve (37) counterclockwise to bleed off air en­trapped above oil to ensure stable operation.
MODEL “8310HP-1+8”, OR MODEL “8310HP-1+6”, OR
MODEL “8310LP-1+6”
DIFFERENTIAL PRESSURE REDUCING REGULATOR
Cashco, Inc. P.O. Box 6 Ellsworth, KS 67439-0006 PH (785) 472-4461 • FAX (785) 472-3539 E-mail: sales@cashco.com or exportsales@cashco.com
Loading...