Cashco 5200P User Manual

INSTALLATION, OPERATION & MAINTENANCE MANUAL
IOM-5300P
1-04
MODEL 5300P
AIR FILTER REGULATOR
SECTION I
I. DESCRIPTION AND SCOPE
These regulators are designed for air service only. Maximum allowable inlet pressure is 290 psi. Operating temperatures are -20o to 180o F. The 5300P has low capacity internal relief which provides very limited down stream over pressure protection. Note: Non-relieving version does not provide internal relief. To avoid exceeding outlet pressure limits in ser­vice, a pressure-relieving or pressure-limiting device should be provided.
SECTION II
II. INSTALLATION
Install the regulator as close as possible to the instrument or tool it is to service. Clean all pipelines to remove dirt and scale prior to installation. The words "IN" and "OUT" are cast into the body to indicate the direction of fl ow. For best fi lter drainage orient the drain valve so that it is at the lowest point on the drip well housing. The exhaust port should be kept free and unplugged. Position the regulator so the vent is at the lowest point possible, or provide additional protection to prevent contaminants from entering the regulator. Rotating the bonnet relative to the body may change the vent hole orientation. Exhaust may be remotely vented by installing tubing to the 1/8" NPT port. Apply pipe compound or sealing tape to the male pipe threads prior to installing regulator. Use caution to prevent the sealant from getting inside the regulator.
SECTION III
III. PRINCIPLE OF OPERATION
Prior to turning on supply air, back off adjusting screw until there is no compression of the range spring. After turning supply pressure on, turn the adjusting screw clockwise to increase outlet pressure. Tighten locknut to maintain desired pressure setting.
SECTION IV
IV. MAINTENANCE
1. To remove condensate, slowly open drain valve and bleed accumulated liquid.
2. To clean fi lter element a. Shut off supply air. b. Drain condensate. c. Remove four corner bolts from bottom of unit. d. Remove dripwell housing and fi lter. e. Clean parts and reassemble in reverse order.
WARNING A
These products are intended for use in industrial compressed-air systems only. Do not use these products where pressures and temperatures can exceed those listed under specifi cations.
Before using these products with fl uids other than air, for non-industrial applications, life­support systems, or other applications not within published specifi cations, consult factory.
5300P Instrument Air Filter Regulator
Cashco, Inc. P.O. Box 6 Ellsworth, KS 67439-0006 PH (785) 472-4461 Fax (785) 472-3539 e-mail: sales@cashco.com or exportsales@cashco.com
Printed in U.S.A. IOM-5300P