Carrier EACAAXCC0014, EACABXCC2020, EACA0014, EACA0020, EACA2020 Installation And Operation Manual

Page 1
EACA
Electronic Air Cleaner
Sizes 0014, 0020, & 2020
1
Manual for:
Installation Operation Maintenance
CAUTION: Read installation instructions and rules carefully for safe operation.
Form # EACA-1SI I II EACA-14-1 Date 07102
Page 2
Table of Contents
Safety Considerations & Introdudion
Un;t spealficatJons
Facts you should know about your new Electronic Air Cleaner
1) Regular dusting & "white dust"
2) Ozone
3) Air flow sensor operation
4) High altitude applications
Replacing the ionizing wires
Common Q & A
Maintenance of your Electronic Air Cleaner
1) Removing the ceils and prefllter
2) Washing the cells and prefilter (s)
3) Replacing the cells and prefilter(s)
Common troubleshooting techniques
Installation instructions (for use by authorized HVAC contractors)
Technical troubleshooting flowchart
Replacement part list
List of figures
Figure 1
Figure 2
Figure 3
Table 1
Figure 4
Figure 5
Figure 6
Figure 7
Figure 8
Figure 9
Figure 19
Air flow sensor diagram
Reducing ozone inhigh altitude applications
Cleaning the ionizing-collector cells
Symptoms of excessive amieg or zapping
Unit dimensions
Technical specifications
Typical HVAC system configurations
Sheet metal transitions
Turning vanes from in_rovieg air flow
Proper installation of ceil spacer
Proper mounting diagram
Wiring the unit to the input power source
Electrical schematic diagram
Testing the power supply output
Troubleshooting flowchart
Un_ p a r f s diagram
L _
Page
1
2
4
4
5
6
7
8-9
10
10
11
11
12
15 29
29-30
31-32
Page
5
6
10
12
13
15
16
19
18
19
21
22
26
28
29-30
31-32
Page 3
NOTE: Read the entire instruction manual before starting the installation.
Safety Considerations Improper installation, adjustment, alteration, service, maintenance, or use
can cause explosion, fire, electrical shock, or other conditions which may cause personal injury or property damage. Consult a qualified installer,
service agency, or your distributor or branch for information or assistance. The qualified installer or agency must use factory authorized kits or accessories when modifying this product. Refer to the individual instructions
packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses and work gloves. Read these instructions thoroughly and follow all warning or cautions attached to the unit.
consult local building codes and National Electric Code (NEC) for special
requirements.
Recognize safety information. This is the safety-alert symbol L .Whenyou see this symbol on unit or in instructions and manuals, be alert to potential for personal injury.
Understand the signal words DANGER, WARNING, and CAUTION. These words are used with the safety alert symbol. DANGER identifies the most
serious hazards which will result in severe personal injury or death. WARNING signifies a hazard which could result in personal injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage. NOTE is used to highlight suggestions that will result in enhanced installation, reliability, or operation.
This manual provides information for location, installation, operation and service. Before installation and use of the air cleaner, carefully read these
instructions to insure maximum benefits from the unit and to avoid needless service costs that can result from improper installation.
Page 4
INTRODUCTION
This electronic air cleaner is technically known as a two-stage electrostatic
precipitator. The air cleaner is designed to remove airborne particulates, including dust, dirt, smoke, pollen, virus, spores, bacteria and mold, from indoor
air.
Air movement through the unit is provided by the heating, air conditioning or ventilating system blower. As dirty air enters the air cleaner, the air passes through a metal mesh prefilter. The prefilter prevents lint, pet hair and other large
particulates from entering the air cleaner. It its important that these filters be in
place to prevent excessive dirt loading of the air cleaner collector cells. These filters extend the time between maintenance of the air cleaner collector
cells.This allows the ionizing-collector cells to provide clean air for a longer period between washings.
The prefiltered air then passes through a two-stage Electronic Air Cleaner. In the first stage, all airborne particulate, even submicron size, are electronically
charged (positive) as they pass through the ionizer. The ionizer field is set up by a corona discharge emanating from the fine, tightly strung wires suspended
between two adjacent flat plates. In the second stage, the charged particulate
passes through an intense electrical field established between alternately charged and grounded parallel collector plates. Here, the positively charged
particulate isattracted to the negatively ground plates and removed from the air stream.
For a unit diagram and a complete listing of atl parts, please see page 31-32.
INOICATING LIGHTS
CELL CONTACT
POWER TRAy
,_SEMBLY
CABINET
II II
I
i
COLLECTING _LL(I
Page 5
UNIT SPECIFICATIONS
This air cleaner is easy to install, operate and maintain. Its basic components arethe:
Cabinet Mounts to existing ductwork; houses the ionizing-collecting cells and prefilters.
Ionizing-Collector Cells
Collect the dust, dirt and other particulates in the air. They contain the ionizing and collecting sections as described on page 2. The cells must be
installed with ionizing wires on the air intake side. A spring contact is located on the top of each cell and must be in position to make contact with the contact board assemblies on the bottom of the oower tray assembly.
Prefilters
Trap large particulates before it enters the ionizing-collector cells.
Power Tray Assem bly
Contains the indicating light, solid state power supply, contact boards and electrical controls including ON/OFF switch and safety interlock switch. A
power cord at the rear of the tray allows the unit to be connected to a
standard 120V outlet. A wiring compartment is provided at the rear of the tray allowing the option to permanently wire the unit directly to a fumace control.
Air Flow Sensor (AFS)
Installed on certain models, this part controls the operation of the unit by
sensing the movement of air within the duct. This helps to reduce power usage and prevents the possible buildup of ozone within the duct.
Howto Identify Which Air Cleaner Model you own The model number and serial number for your Electronic Air Cleaner can be
found on the data label located on the inside of the access door. This serial number will be a ten (10) digit number.
3
Page 6
FACTS YOU SHOULD KNOW ABOUT YOUR NEW
ELECTRONIC AIR CLEANER
Dusting and "White Dust"
Your new Electronic Air Cleaner will efficiently clean and filter your household air. Unfortunately, it will not eliminate the need for regular dusting of your
furniture and belongings. Due to the design of all duct-mounted air cleaners, they can only clean the air that reaches the air cleaner. Therefore, if the
particulates are not being carried to the air cleaner in the air stream, the air cleaner cannot remove them from your home.
Occasionally a "white dust" may be noticed in bedrooms or newly furnished rooms. This is mainly composed of lint which, because it is heavier than other particulates, settles before it reaches your unit.. This "white dust" is not mixed
with airborne dirt particles, therefore, it is clean and has no staining or soiling
properties. However, running the furnace blower continuously, day and night,
will help reduce this from occurring.
_Ozone
Under normal operating conditions all Electronic Air Cleaners produce minute quantities of ozone as an incidental by-product. In fact, all electronic products, such as televisions, cordless phones and refrigerators, produce
some amount of ozone. The average homeowner can detect the smell of ozone concentrations as low as 25 to 100 ppb (parts per billion). The design of
this unit has been tested and ozone production is approximately half of the
published permissible limits established by the Environmental Protection Agency. These limits recommend that the concentration of indoor ozone not exceed 50 ppb. Ozone is not harmful in these concentrations. In tact, the ozone level in major cities can sometimes reach as high as 100 ppb on a summer day. The addition of optional charcoal after-filters can help reduce
this.
Normally, a new unit will produce more ozone than one that has been in
operation for several weeks. This is due to sharp corners or manufacturing burrs on the ionizing-collecting cell(s) and is normal. As the Electronic Air
Cleaner arcs and zaps, the voltage is vaporizing these areas and tends to round them off. This is part of the breaking-in period of ownership and the issue is self-correcting. Also, high-altitude locations can be more susceptible
to noticing the presence of ozone.
An ionizing-collecting cell that has been damaged or bent (the designed spacing between electrically charged and ground components has been decreased) may also produce an abnormal amount of ozone.
Page 7
How the Air Flow Sensor Works (available on specific models)
The electronic AFS was designed to provide an efficient and reliable method
of controlling the operation of the air cleaner when the dealer is unable to wire the unit directly into the furnace blower. The electronic AFS utilizes a thermistor that heats up to approximately 130°E The AFS then stabilizes at
this temperature and when the furnace blower turns on and air flows through
the ductwork, the same vacuum effect pulls cooler air over the hot surface. This air movement cools down the thermistor and this cooling down effect
allows the electronic AFS to understand that the furnace blower is moving air and the Electronic Air Cleaner must turn on to provide air cleaning.
If the air cleaner is installed in a location that is dusty and dirty, the sensor on the AFS can become coated with dirt and lint. This coating can insulate the
AFS and keep it from operating properly. To clean the thermistor, take a cotton swab dipped in rubbing alcohol and carefully insert it into the hole located on the right hand side of the power pack assembly (when facing the
unit). The hole is 3/16" in diameter and is located on the front of the power
tray assembly. Carefully twirl the cotton swab between your fingers, making sure the tip is lightly in contact with the grey disc, cleaning this coating from
thethermistor. T.E.___
Figure 1
individual to personal injury
1. Make sure the furnace blower is not operating, the rocker
is OFF and the circuit breaker is turned OFF or cord is disconnected.
4. Locate the AFS. It is a circuit board with a small grey_q connected to the circuit board by two(2) silver .wi'res (sir_ to
Figure 1). Carefully bend the thermistor so that it is Iocat, In the
center of the opening and approximately 1/8" from the inside edge of the power pack assembly.
5. Reinstall the power tray assembly end access door.
Page 8
i
Hiqh Altitude Operation
Because the air is less dense at higher altitudes, there is a possibility of nuisance arcing. The homeowner can quickly and easily correct this
condition.
1. TurntheunitOFE Disconnectcordorturnoffcircuitbreaker.
2. Remove the two screws that secure the cover to the power tray and remove it from the unit. (The entire power supply tray may be removed
from the cabinet by removing two screws from inside the cabinet.) Do
not lose these screws.
3. Locatethejumperterminal (seefigure2).
4. With a pair of needle nose pliers, carefully adjust the jumper settings from HIGH to MED. Ensure that the jumper is firmly seated in the terminal.
5. Replace the power tray cover and secure it with the two screws.
6. Replacethe access door and turn the unit ON.
This procedure will slightly reduce the output voltage, minimize arcing and
reduce ozone production. If the condition does not improve, repeat the above procedure and move the jumper setting from MED to LOW. If this
does not correct the situation, contact your local HVAC dealer.
All Electronic Air Cleaners are produced at the factory with the jumpers set in the HIGH position. However, the output voltage may be lowered in any
situation where the unit is arcing excessively or there is excessive ozone production.
Figure 2
Page 9
REPLACING THE IONIZING WIRES
Ionizing wire breakage is minimal because of the constant tension design and fixed location of the ionizing wire supports. When an ionizing wire
breaks, the efficiency of the Electronic Air Cleaner will decrease slightly.
However, the unit will continue to operate with broken ionizing wires as long
as the broken wires have not caused a short circuit of the unit. Remove all
loose and broken wires as soon as they are identified.
Although the replacement of the ionizing wires can be attempted by a homeowner, it is recommended that a qualified HVAC contractor be
contacted for replacement parts and/or servicing. Wires are supplied in a coiled spring configuration, with a clinch nut on each end of the wire.
Replacement requires a pair of needle nose pliers. Exercise caution in removing any broken wires in the collector cell. This will prevent accidental shorting of the cell and reduce the need for further maintenance.
Usethe following procedure when replacing an ionizing wire.
1. Ensure that all power to the Electronic Air Cleaner is OFF, remove the access door and remove the ionizing-collector cells from the unit.
2. Carefully remove all remains ofthe broken wire.
3. Grip the new wire at each end of the wire with your thumb and index finger. While stretching the wire to approximately 6" allow one end of
the wire to uncoil between your thumb and index finger.
4. Place one end of the wire in the slot of the stainless steel support on the collector cell from the front of the cell. This support is partially
covered by the cell brace in front of the support.
5. Grip the other end of the ionizing wire with needle nose pliers and
insert the terminated end of the wire into the slot on the support bar of
the opposite end of the collector cell.
6. The wire should be tight enough to be self supporting and remain
suspended between the two support slots in the support bar.
7
Page 10
Common Questions and Answers
Q.
A.
Why isn't my' air cleaner cleaning my air? The air cleaner is most likely working just like it was designed.
However, many factors can affect the performance of the unit. Are cold air registers located in the ceiling? If so, it will be difficult for the air flow to
carryheavierparticulatestotheaircleaner.lfthedirtdoesn_getto the air
cleaner, it can't be removed from the air. Are both the Red and Green lights illuminated? If not, then the unit may be in need of servicing. Contact your
local HVAC dealer for assistance.
e.
A.
It still isn't cleaning my air the way I want it to. What can Ido?
We recommend that you run the blower continuously so that the air
movement will carry the dirt to the air cleaner. Unfortunately, there will
always be some dirt that is left behind on the appliances, furniture, etc.
Regular dusting is recommended to stir up these pockets of dust so that
they can enter the airstream and be removed by the Electronic Air Cleaner.
Q. When I turn on my Electronic Air Cleaner, the lights come on for a couple
of seconds and then turn off. The air cleaner isnhtworking!
A. The air cleaner is fine as long as both the Red and Green lights are
coming on. Try turning the HVAC blower OFF and then turning the
Electronic Air Cleaner on. This should solve the problem.
Q. What is the zapping noise I'm hearing from my unit? Should I be
concerned?
A. The zapping or popping noise that you are hearing is the sound of larger
particles being "vaporized" by the ionizing-collector cell. This is normal
and is no cause for alarm. As your HVAC system blower moves the air through the ductwork and allows the Electronic Air Cleaner to clean the
air, the noise will diminish. However, there will always be instances when larger particles enter the ionizing-collector cell.
Q. Should I hear this zapping noise all the time?
A. All Electronic Air Cleaners will occasionally zap or pop as larger particles
pass through the ionizing-collector cells. However, if the sound is constant or is repetitive in nature, then a large particle may have become lodged in the ionizing-collector cells and they may require cleaning. If cleaning the ionizing-collector cells does not stop the noise and there
are no large particles trapped in the ionizing-collector cells, then the
cause could be a broken/loose ionizing wire, bent collector plate or other mechanical reason. Please contact your local HVAC dealer for assistance.
8
Page 11
Q. What if I no longer hear any popping or zapping noises coming from
my unit? Is it still cleaning the air?
A. If the zapping noises stop and the air cleaner is not in need of
servicing, then one of two situations has occurred. First, the Electronic
Air Cleaner has successfully removed all larger particles from the air
and is cleaning microscopic particles which do not cause the zapping noise. Second, the blower and/or HVAC system is not running and air
is not flowing through the ductwork. The Electronic Air Cleaner cannot remove particles if the air stream is not moving.
Q. I lost power to my home during a storm. Should I worry about the
Electronic Air Cleaner?
A. The most common problem associated with power outages is the unit
will not turn on properly after power is restored. If the Red and Green
light come on for a couple of seconds and then go off, the unit is OK. Just turn the HVAC blower off, turn the unit ON and then turn the
blower back on. If the Red and/or Green light does NOT come on after a storm, the power supply in the Electronic Air Cleaner may be
short circuited. Contact a local HVAC contractor for further information.
Q. My installer told me to keep my HVAC system blower running all the
time, but I don't want to increase my power bill. What should I do?
A. It is recommended that you keep your HVAC system blower running
all the time to achieve the maximum air cleanJng efficiency. This will
allow the Electronic Air Cleaner to do what it is designed to do, which
is clean the air. Remember that if the air does not reach the air cleaner,
it cannot be cleaned. On average, your Electronic Air Cleaner will use the same amount of electricity as a 55W light bulb. The energy usage of the HVAC system blower will depend on the age of your system,
energy costs in your regional location and other variables. The best
solution is to try running the HVAC system blower in continuous mode for a month or two to estimate your annual energy costs and base
your final decision on what you feel most comfortable with.
9
Page 12
MAINTENANCE OF YOUR ELECTRONIC AIR CLEANER
_WARNING :Handle ionizing-collector cells with care as plates
,can be sharp and cause injury if not handled properly. __.
WASHING CELLS AND PREFILTERS
Regular washing is necessary to ensure proper performance. A thorough
washing once every two months will be adequate for most installations.
More frequent washing (once a month) may be necessary on some installations (new homes for example) where there is new carpeting, plaster dust, or excessive cigarette smoke (Figure 3).
To remove cells and prefilter
1. Push air cleaner switch to the OFF position. Wait 15 seconds. Open door
access panel.
2. Carefully remove cells and prefilter(s) and set aside in a safe place,
3. Do not drop the ionizing-collector cell. This could cause damage to the cell plates or ionizing wires and cause excessive arcing and noise.
10
Page 13
Towashcells and prefilter(s)
We suggest that you follow the instructions below to properly and
thoroughly clean your collector cells.
1. Place enough hot water in a utility tub to cover the first cell. Dissolve 2 to 4 oz. of granulated automatic dishwasher detergent (not laundry detergent) in the water.
2. Allow the cell to soak for 30 minutes. Agitate it up and down in the solution until it appears clean and remove.
3. Repeat with second cell.
4. Agitate the prefilters up and down in the solution until they appear clean.
5. With a hose, rinse the cells and prefilters. The hose should be held about 10" from the cell plates and at a slight angle for better cleaning
results. Be careful not to spray the ionizing wires directly with the hose. The water pressure can cause the wire to snap and break. The cell frame should be thoroughly rinsed along the edges to dislodge
any trapped lint or dirt. Carefully wipe a damp cloth or sandpaper (not emery cloth) along the ionizing wires.
6. Stand cells and prefilters up to drain. Let dry two hours. You may experience a slight discoloration of the aluminum collector cells after washing. This is a normal chemical reaction and will not harm your
unit or affect its performance.
To replace cells in air cleaner
1. Replace prefilter and cells in cabinet. Check that arrow on cells points in same direction as air flows through the duct. (If you have to force it past the positioning screw on bottom, it is probably in the wrong position.)
2. Replace access door (engage tabs on lower edge of door into slots in cabinet). Carefully close door.
3. Turn air cleaner switch to ON.
11
Page 14
COMMON TROUBLESHOOTING TECHNIQUES
SYMPTOM POSSIBLE CAUSES
Broken or loose ionizing wire(s)
Rapid arcingor zapping
Excessive ozone smell
Excessive ozone smell
Hissing or siZZling noise
Green LED light is not ON
Reci LED I_ght is nct ON
Dirty ionizing _oltector cell
Damaged or bent collector plates
Dirty insulator caps on ionizing-
collector cell
Air cleaner is wired directly to a
t20V power source
Loose high voftage connections
Radio or television interference
Poor electrical contact
NO power available
I Loose at ON/OFF switch
wiring
Defective ON/OFF switch
ON/OFF switch not in ON position
Loose wiring within power pack asSembly
Broken or shorted electrical component
Excessive dirt build up on ionizing wires
CORRECTIVE ACTION
Remove broken or loose wire and replace wtth new wire
Clean as outlined on page t0-! 1
Straighten plates with needienose pliers or replace engre ionizing-
collector cell
Clean with warm soapy water and rinse well
Qua[itie<3 HVAC contractor must
install AFS or rewire air cleaner
To the HVAC system blower
Repair or replace the component
Uncommon occurance --
check for good common ground for air cleaner
Ensure that there is a good connection between the top of the ionizicg-coliector cell and the bottom of the contact beard
assembly Contact HVAC contractor
Reset circuit breaker Replace fuse
Check for secure connection
Replace ON/OFF switch
Turn the unit ON
Check for secure connections Contact HVAC contractor
Contact HVAC contractor
Clean wires with alcohol and
allow to d_/thoroughly before turning the unitON
Contact board assemblies are Replace contact board assembly corroded or cad3onized
Broken ionizing w_re
Dirty ionizing collector cell
Foreign object located between collector plates
Damaged or bent collector plates
Insulators are corroded or carbonized
Table 1
12
Remove broken '_itre and repiec_ with new wire
Clean as outlined on page 10-11
Remove object from ionizing- Cofleotor cell
Straighten with a pair of needle- nose p_er,_ or replete ceil
Replace insulators or ionizing-
Cctlector cell
Page 15
UNIT DIMENSIONS - All dimensions in inches (mm)
EACA
!
_r
iiii¸ _ ............_ B: D ; E F = G
572
Inches MM Inches MM Inches MM Irtche_ MM Inches MM Inches MM Inches MM
_20 24-1/4 616 17-7/8 453 20-15116 531 I 22-1/2 24-7/8 632 7-1/8 181 21-7/16 545
0014 20-1/4 514 13-7/8 352 16-15116 429 22-1/2 572 24-7/8 632 7 1/8 181 21-7/16 545
I
2020 24-1/4 616 17-7/8 453 20-15/16 531 19 I 483 21-3/8 543 7-1/8 181 18-5/6 473
I
Dimensions _'e the same f_- both models with and wtthc_ Air Row _ensors installed
13
Page 16
Only a trained, experienced serviceman
,should install this electronic air cleaner.
A thorough checkout of the unit installation should be completed before unit
operation. Electrical shock can cause serious injury or death.
14
Page 17
TECHNICAL SPECIFICATIONS
(Specifications subject to change without notice.)
MODEL NUMTER-EACA 0014 0020 2020
D/MIENSlONS (IN) 20 1/4 x 7 1/8 X 24 7/5 24 1/4 _ 7 1/8 x 24 7/8 24 I/4 x 7 1/8 x 21 3/8
UNIT COLOR American Sterling American Sterling American Sterling
AIR FLOW SENSOR INSTALLEO NO NO YES
ELECTRICAL iNPUT 120_ 60 HZ, 1 PH 12e_ 60 Hz, I PH 240V, 60Hz, 1PH
MAXIMUM RATED AIR FLOW 1400 CFM 2000 CFM 1400 CFM
(2380 m3/hr.) (3400 m_lhr.) (2380 m3hr.)
MAX/MUM PRESSURE DROP ,I 1 inch w.g. ._4 inch wg .I _ inch w.g.
@1400 CFM @ 2000 CFM @ 1400 CFM
CELLWEIGHT (2 CELLS IN EACH UNIT) 10 Ibs. each 12 Ibs Each 9 Ibs Each
(4,45 k9) (5.45 kg) (410 kg)
UNIT WEIGHT 32 Ibs 30_bs 36 Ibs
(14.6 kg) (16.4 kg) (16,4 kg)
MAXIMUM POWER CONSUMPTION 40 watts 48 watts 40 watts
ELECTRICAL OUTPUT 2.5mADC 3.2 mADC 2.5 rnADC
@ 5200 kVDC @ 0200 kVDC @ 6200 kVDC
CLASSIFICATION I UL/CUL UUOUL UUCUL
15
Page 18
TYPICAL MOUNTING POSITIONS
Shaded illustrations are for positioning use only
AreaFLOW _/_
!sHi
rP_NS'TIO_S AIR C_A_E_
_ CLEA_R
\
BASEMENT FURNACE
(LOWBOY) Mounted horizontally in return plenum - just above the furnace
l
COUNTERFLOW FURNACE SPACE SAVER FURNACE Mounted horizontally in return (HIGHBOY) duct - just above the furnace Side installation. Cleaner is
mounted vertically, where
return air enters side inlet of
furnace.
OFFSET INSTALLATION I J I } _ If there is less than 7-in. for mounting the air cleaner I __ /'] }/._
between the duct end the furnace, move the return air drop. /_ _,
/_ --_-...._
_ C_EANFR/ _
/,
SPACE SAVER (HIGHBOY) Installation beneath furnace. Cleaner
mounts horizontally, where return air
enters from below. Raise furnace by
installing a suitable wood structure and install air cleaner.
HORIZONTAL FURNACE Mounted vertically in return duct as close to
the furnace as possible
16
Page 19
PLANNING THE INSTALLATION
A_ation
The air cleaners are used in forced air heating cooling and ventilating systems. The
air cleaner should be installed in the system so that all the system air is circulated through the air cleaner. The air cleaner will only remove the airborne contaminants
delivered to it. Maximum performance is obtained when the system blower is set for continuous operation.
Installation Requirements
The best location for the air cleaner is in the return air duct next to the blower compartment. Inthis location, the blower motor and cooling coils will be kept clean.
DO NOT INSTALL THE AIR CLEANER
IN THE DISCHARGE AIR DUCT.
Before installing the air cleaner, consider the application and type of HVAC system present. Refer to the section entitled Typical Mounting Positions,
for the most common types. If a transition between the ductwork and air cleaner is
required, refer to section entitled Transitions. The unit must be readily accessible
for periodic inspection and cleaning of the prefilters and electronic cells to maintain
maximum efficiency and trouble-free operation.
Air Conditioninq The air cleaner should be installed upstream of the cooling coil. This will keep the
coil clean and reduce air conditioning coil maintenance. Improved cooling efficiency is the result and directly affects energy costs. A clean coil, will reduce
utility costs. If the air cleaner is downstream of the cooling coil, condensation will
form on the cooled collector plates when the air conditioner cycles. This will allow water droplets to form on the collector plates and cause nuisance arcing. Arcing will
reduce air cleaner efficiency and reduce the life of the high voltage power supply.
Humidifiers
An evaporative humidifiercan be mounted upstream of the air cleaner. It is best to install an atomizing humidifier downstream of the air cleaner because hard water salt deposits and water droplets may damage the air cleaner. If an atomizing humidifier must be mounted upstream of the air cleaner:
1. Mount itas far upstream as possible. (Recommended at least 6 feet.)
2. Install a standard disposable furnace filter between the humidifier and the air cleaner to trap water droplets and hard water salts.
3.Clean the air cleaner more frequently to prevent a hard water salt
buildup.
Outdoor Air
When outdoor air isadded to the returnair duct, sufficient heat should be added to
maintain the return airtemperature at 40°F (4°C) minimum. Lower temperatures can cause ionizer wire failure.
17
Page 20
Atomizincj Humidifiers
If an atomizing humidifier is installed, it must be mounted downstream of
the air cleaner•
1. Mount the humidifier as far downstream as possible, it is recommended a distance of at least 10 feet to reduce the possibility of excessive arcing
as water droplets pass through the Electronic Air Cleaner.
2. Install a standard disposable furnace filter between the humidifier and the air cleaner to trap water droplets and hard water deposits.
3. Clean the air cleaner more frequently to prevent a hard water buildup•
Sheet Metal Installation The Electronic Air Cleaner is adaptable to all new or existing residential forced air furnace and cooling systems.
Transitions If the air duct does not fit the air cleaner cabinet opening, gradual transitions are recommended to reduce air turbulence through the air cleaner and
maximize efficiency. Not more than 20 °
(about 4" per running foot) of expansion
should be used on each side of the transition fitting (Figure 4).
Outdoor Air When outdoor air is added to the return air
duct, sufficient heat should be added to maintain the return air temperature at 40°F
(4°C) minimum. Lower temperatures can
cause ionizer wire failure.
Fu._
_--4
Turnincj Vanes
If the air cleaner is installed adjacent to a 90 ° duct elbow, add turning vanes inside the duct to improve air distribution across the face of the air cleaner (Figure 5).
Failure to follow the recommendation can reduce the efficiency of the Electronic Air
Cleaner.
Figure 4
/
Figure 5
18
Page 21
SELECT LOCATION FOR AIR CLEANER
Remember to select a location that is readily accessible for periodic inspection and cleaning of this air cleaner. Allow a minimum of 24"
clearance in front and 12" clearance above the air cleaner for component
removal and service space. For complete dimensions required refer to the section entitled UNIT DIMENSIONS.
DIRECTION OF AIR FLOW THROUGH THE AIR CLEANER This air cleaner is set up for left to right air flow when you are facing the
access door.
For right to left air flow, follow these directions:
1. Remove the prefilter(s) and cells from the cabinet. A plastic positioning spacer is
located inside the bottom of the cabinet.
This spacer is secured to the cabinet using
a #6-32 round head Phillips drive thread cutting screw to assure installation of the
cells in the proper position with respect
to air flow (Figure 6).
2. Remove the screw and reposition the
spacer in the alternate hole at the bottom of the cabinet.
/
Figure 6
SCREW
PLASTIC
' SPACER
3. Replace the screw to insure the plastic spacer is not accidentally
knocked out of place during normal maintenance. It must be installed in
the hole provided closest to the air leaving side of the cabinet. Seal the
unused hole with duct tape.
4. Remove the cell handle and reattach to the opposite end of the cell. Turn
cells around, replace in cabinet and replace prefilters on the air entering side. The directional arrows on the cell end plates must point in
the direction of air flow.
19
Page 22
INSTALLATION
!. CAUTION: Only a trained experienced serviceman should
_all this electronic air cleaner. The power supply should be
'_removed before installation. To remove the power supply, remove I the two (2) screws (See Figure 7) in the top front of the cabinet.
] Remember to keep this hardware for reinstallation of the power
supply when the air cleaner installation is complete. A thorough
I checkout of the unit installation should be completed before unit ! operation.
PHYSICAL INSTALLATION OF THE AIR CLEANER
This Electronic Air Cleaner can be installed in any position, except with the access door facing down. The section entitled TYPICAL MOUNTING POSITIONS show examples of proper air cleaner mounting with a variety of
furnace installations.
Prior to installing this product...
1. Read rules and instructions carefully for safe operation. Failure to follow them could damage the product or cause a hazardous condition.
2, Check the ratings given on the product to make sure it is suitable for your
application.
3. Select a location for the air cleaner.
4. Remove the old furnace filter and discard.
5. The air cleaner cannot remove existing dirt from the blower and ducts. Clean the area thoroughly before you begin.
6. Remove unit access panel, and slide the prefilters and ionizing-collecting ceils out of the cabinet. Place them safely aside with the warranty and
registration card. NOTE: The following is a typical installation of the air cleaner on a
highboy furnace. You may have to alter the installation to fit your particular application.
2O
b
I
Page 23
,
,
Locate the cabinet in the cold air return duct so that all of the return air
flows through the unit (Figure 6). If the furnace and air cleaner openings
are different, use a transition (Figure 4).
Mounting holes are provided for
ductwork attachment (Figure 7). The
.140" holes are sized for #8 sheet metal screws, or 1/8" rivets. If the
adjoining ductwork is flanged, install the screws so that the screw heads
are inside the cabinet. This will prevent damage to the prefilters and optional charcoal after-filter during
removal and installation after cleaning.
9. After the unit has been secured, seal seams air tight with duct tape or
caulking.
Figure 7
ATTENTION: On Electronic Air Cleaners that have the air flow sensor installed at the factory, be especially careful not to cover the air flow sensor orifice when sealing the air cleaner and ductwork. This hole is
located on the right hand side of the enclosure that holds the power pack assembly (when facing the unit). The hole is 3/16" in diameter and
is located on the front of the power tray assembly. In applications with minimum air flow, it is helpful to seal any openings on the power tray
assembly or cabinet. This will increase the velocity of air flowing over the air flow sensor, enabling the air flow sensor to turn the Electronic Air Cleaner on and off. The only opening required for actuation of the air flow sensor is the 3/16" diameter hole previously described.
10. Refer to the section entitled DIRECTION OF AIR FLOW.
11. Install prefilters and ionizer-collector cells.
12. Reinstall power trayassemblyintothe cabinet.
13. Reinstall unit access panel.
21
Page 24
ELECTRICAL INSTALLATION
A)I wiring must comply withapplicable local and national codes.
I Be sure all incoming power is OFF before beginning any procedures.
I Thefollowing instructionsare for use byqualified personnel only.
I _
L J
The Electronic Air Cleaner (without the AFS installed at the factory) is designed to take advantage of the integrated accessory control panel available on most furnaces. The 12OV Electronic Air Cleaner tap on the furnace will provide
power to the air cleaner only when the circulating air blower isin operation.
Read the instructions in the furnace installation manual carefully before attempting instal_efion or operation. Failure to follow these instructions may result in improper installation and therefore void warranty.
An optionef(on 120v model) electronic air l_ow sensor kit isavailable ifthe air cleaner is not equipped with an AFS. This air _ow sensor will sense the air movement w_thin the duct and turn the Electronic/_r Cleaner on and off accordingly.
Figure 8
I [IW:_.lllllt|] _
WIRING PROCEDURE This air cleaner is powered by providing power to pigtail
leads at field wiring compartment (see knoCk-Out holes)
loCated at the rear of the power pack assembly (See Fig.
0).
1. Turn air cleaner OFF using ON/OFF switch located on front panel.
2. Remove power pack cover plate by removing front door and two screws holding assembly to the top of
theair cleaner.
3. Make wiring connections inside junction box area (See Fig. 8). Remove knOCk-Out and use conduit or
other approved methods to supply input power.
Connect ground wire to clip.
4. Replace the power supply cover plate and secure with screws removed from step 2.
5. Replacethe unit door to the front of the air cleaner.
6, Air cleaner will now operate when door is Ln place,
ON/OFF rocker switch is inthe ON position and input voltage is present in the junction box. The following
should be oompIcted to supply input power to the _r cleaner.
FURNACE APPLICATION It is recommended to use EAC t and EAC 2 terminals
when provided by the furnace circuit hoard. These outputs will provide 120 vac whenever the blower motor
isenergized. Furnace circuit boards without EAC 1 and EAC 2
terminals MUST use alternate methods to supply to supply power to the air cleaner. Options include Sail
Switch, Isolation relay or Optional AFS (Air F!ow Sensor) Air cleaner should only operate when blower motor is
running.
This unit cannot be powered directly from blower motor
/
leads. Voltages can exceed t 90vac for 120-v. motors or possibly double with 240-v fan coil motors, j
FAN COIL APPLICATION of0014 or 0020 Models (120-v.)
if EAC I and F_AC2 terminals are provided by fan coil circuit board, refer to fan coil data to determine voltage
output. Most fan coils do not provide 120-v. at these
termina!s. Alternate methods may be needed to eonved fan coil supply voltage to 120-v. for the cleaner. A 240-v. to
120-v step down transformer (60v) will be needed in most applications. Sail Switch, Isolation relay or Optional AFS
(Air Flow Sensor) may also be needed,
FAN COIL APPLICATION of 2020 Model (240-v.) The Model 2020 is a 240-v, power supply model designed
to match you fan coil, To installthis model with a g40-v, far_ coil:
_|_:tl| I[IU
I This unit cannot he powered directly from blower motor
leads. Back EMF (electro magnetic field) voltages can
l reach40Ovao or240-v.fanco mo ors. J
1. "rum air cleaner OFF using ON/OFF rocker switch loCated on front panel
2, Remove power pack cover plate by removing front
door and two screws holding assembly to the top of the
aircteanec
3. Make wiring connections inside )unction box area (See Fig 8). Remove knock-out and use conduit or other
approved methods to supply input powe_ Connect ground wireto clip,
4. Rep(ace the power supply cover plate and secure with screws removed from step 2.
5.Replace the unit door to the front of _heair cleaner.
6. Air cleaner will now operate when door in place, ON/OFF rocker switch is in the ON position and input voltage is present in the junction box.
22
Page 25
SYSTEM CHECKOUT
_- _,"I",.WARNING: The following procedures should be conducted by a
_ified HVAC contractor or repair person ONLY These procedures
will expose hazardous electrically energized charged components.
Disconnect power between checks and proceed carefullY.
1. The HVAC system blower should be turned OFE
2. Switch the ON/OFF rocker switch to the ON position. The bright red segment of the rocker switch should be visible.
3. Inspect both the Green INPUT POWER light and the Red CELL ENERGIZED light:
If the unit has an AFS installed, the lights should go out in approximately 20 to 60 seconds. This is the normal time for the
electronic air flow sensor to complete its stabilization period. Both lights will come back on when the HVAC system blower begins to
operate. See the section entitled HOW THE AIR FLOW SENSOR WORKS for more information
Ifthe unit is wired directlyto the HVAC system blower, the lights will not come on until the blower begins to operate. In this case, the electronic air cleaner will stay on as long as the ON/OFF switch is in the ON
position and the blower is operating.
Iftheunitiswireddirectlytoadedicated 120Vpowersource, thelights will come on immediately and stay on for as long as the ON/OFF switch is in the ON position, regardless of the HVAC system blower
operation. This type of installation is NOT recommended due to the excessive production of ozone. See the section entitled FACTS YOU
SHOULD KNOW ABOUT YOUR ELECTRONIC AIR CLEANER - OZONE for more information.
4. Wait approximately one (1) minute and turn the HVAC system blower ON. Most thermostats have a setting that will allow you to run the fan
manually. If net, then set the thermostat so that either hot or cold air begins to flow through the ductwork.
5. The Green INPUT POWER light and Red CELL ENERGIZED light should come on, if the unit is wired directly to a dedicated 120V power source, the lights will already be on and will not be affected by the HVAC system
blower operation (see Step 3).
6. Check to make sure that the Red CELL ENERGIZED light goes out when the following conditions occur:
Cell access panel is removed
Rocker switch is switched to the OFF position
HVAC system blower is not running. 23
Page 26
TROUBLESHOOTING
CAUTION:
These procedures should only be attempted by a qualified HVAC
technician or electrician.
Risk of personal injury could occur by attempting to troubleshoot or repair this unit by untrained persons.
Exercise the usual precautions when working with high voltage.
When the circuit has been de-energized, always discharge any
residual current in the secondary with an insulated handle
_rewddver.
; =
Always ground power supply and ionizing-collecting Ceil when bench testing.
Recommended Service Tools
Screwdriver, 8" common with insulated handle (plastic)
Screwdrivers Phillips #1 and #2 with plastic insulated handles
Needle nose pliers
Multimeter
High voltage probe
Indication of Electrical Trouble
The air cleaner is equipped with a Red CELL ENERGIZED light for indicating
proper unit operation. When the unit is in normal operation (with the HVAC system fan running, access door in place and rocker switch in the ON position) and the Red CELL ENERGIZED light is not lit, the problem is a
shorted secondary. Although failure of the indicating light itself should not be overlooked, this condition isunusual and rather remote.
24
Page 27
PRIMARY CIRCUIT WITH FURNACE BLOWER OPERATING
If there is supply line voltage at the connections and no input voltage to the
power supply, the outage can be located by checking operation of the safety switch and the interconnecting wiring with a multimeter. Refer to Circuit Diagram, (Figure 9) to check operation of the switches.
Following these steps to test for proper operation of the circuit board and power supply assembly:
1. Ensure that the circuit breaker controlling the furnace blower is in the ON position and the main fuse is not open.
2. The power supply board has a built-in internal fuse to protect the 24V
transformer. It can be checked visually by inspecting the fuse. If the fine
wire inside the fuse is broken, this indicates a problem in the 24V circuit of
the power supply board. Do NOT replace this fuse. The entire power
supply board must be replaced. The purpose of the fuse is not to protect
the power supply board, but to function as a troubleshooting feature of the product and to protect the transformer from damage.
3. Ifthe fuse is NOT blown, check the ON/OFF switches and safety interlock
switch for proper engagement and operation. This can be completed
using a volt ohm millimeter on a scale that will measure ohms as low as
1.0. If you are using the recommended meter previously mentioned in
this manual, set the meter to read 200 ohm and proceed with Steps 4 through 6.
4. Remove the fuse. Connect one lead to the test pin located directly beside the wire that connects the ON/OFF switch to the power supply board. Connect the other lead to the fuse connection closest to the front panel.
5. Turn the ON/OFF switch to the ON position and depress the safety interlock switch. The meter should have the capability of reading levels
as low as 1.0 oh m.
6. If there is no reading on the meter, begin the process of elimination by disconnecting the wire from the test point and connecting it to the terminal with the blue wire located on the safety interlock switch. Depress
the safety interlock switch. If the reading on the meter is greater than 1.0
ohm, the safety interlock switch is defective and must be replaced. If the reading on the meter is less than 1.0 ohm, the ON/OFF switch is defective
and must be replaced.
25
27
Page 28
SECONDARY CIRCUIT
IONIZING-COLLECTING CELL
The cell is electrically energized through a contact terminal located at the top center
of the cell. The ionizing wires and alternating collector plates are electrically charged while the interleaving plates are grounded.
If the space between the charged and grounded plates is bridged with conductive or semi-conductive material, a short circuit develops. The bridging or short may be caused by damaged plates, or foreign material lodged between/on the components. Since the cell should be periodically removed from the unit to wash away collected dirt, it is susceptible to physical damage, The cell also contains the ionizing wires which, due to their function, have been designed with minimal structural support and are susceptible to breakage. However, trouble related to a shorted collector cell is readily shown by the Red CELL ENERGIZED light and can be quickly isolated by a simple procedure.
To determine if a short exists in one or both of the collector cells, turn the Electronic
Air Cleaner OFF and remove both electronic cells from the cabinet. Shut the door and repower the unit. If the Red CELL ENERGIZED light comes on, an electrical
short exists in one or both of the electronic cells. Replace the cells inthe unit, one at
atime, to determine which cell is shorted.
Most troubles in the cell can be visually detected and corrected (page 12 -Table 1).
NOTE: The ionizer collector cells are not designed for field repair. Ionizing wires and insulators can be field replaced. It is not recommended that you attempt to replace other cell components (i.e.Collector plates, end plates, ionizer supports).
EACA-0014 & 0020
_Z1,J
LJIlm.J
---- @
Figure gA
EACA-2020
= @
Figure 9B
26
Page 29
CHECKING THE POWER SUPPLY
If the output light remains out with the collector cells removed from the cabinet, the power supply is defective. Specific problems on the power tray assembly can be isolated by using a multimeter and high voltage probe to
check the output voltages.
To check the secondary circuit, a high voltage meter is required. See the section entitled RECOMMENDED SERVICE TOOLS. To check for proper
operation, it is imperative that the procedure be followed as outlined below:
1. Make sure the furnace blower is operating, the control switch is on and input voltage is 120 volts, 60 Hz.
2. Remove front door assembly panel.
3. Remove power pack access cover.
4. Check the high voltage contact board assembly(s) for damage or carbon tracking.
5. Make connections from the high voltage probe to the multimeter in accordance with the operatoCs manual. The meter should be set for
reading DC voltage on the 20 volt full scale.
6. Attach the high voltage probe ground lead to the cabinet. While depressing the safety switch lever, touch the ionizer wire support bar
with end of the high voltage probe (Figure 10). The meter reading should
be 6.2 kVDC ± .2 kVDC,
7. If no voltage is measured, remove the first cell and check the second cell.
The meter should read 6.2 kVDC ± .2 kVDC.
8. If proper voltage is measured, the first cell is shorted. Refer to Table 1, on page 12.
27
Page 30
.
If no voltage is present, remove the second cell. Install cell number one and measure voltage as described above. If voltage is present, the
second cell, which is now out of the cabinet, is shorted. Refer to Table 1 on page 12.
10.
If no voltage is present, remove both cells and measure the power supply output. While depressing the safety switch, touch the end of the
high voltage probe to either the front or rear contact board assembly
(Figure 10). The meter should read 6.2 kVDC or higher.
11. If no voltage is present, check the power supply. Set the multimeter for reading AC voltage at 200 volt full scale and attach meter test leads.
12. While depressing the safety lever, touch the two transformer output lead
junctions to the power supply board with the meter leads and read the
meter.
13. If there is no output voltage from 24 volt transformer, replace the 24 volt
transformer and power supply board.
Figure 10
28
Page 31
TROUBLE SHOOTING THE DUCT MOUNT ELECTRONIC AIR CLEANER
No
i L --7
}s the unit operating? " _ _;s the furnace bower on?
J
+_Yes
r
I Is input AC power available?
-- -- _ Yes
I Is the safety interlock system OK?
Yes
Yes
J
Is red light on?
Yes
Is ON/OFF switch working?
]k_[ Is cell dirty or defective?
IAre contact boards OK?
ryes
ts the power supply wiring OK?
JrYes
IIs power supply defective?
lls transformer defective?
[
Yes
I,
Is celt crackling and snapping? _s
_NO
I Is cell sizzling? ........ _ Yes
29
Page 32
WARNING: The following steps will expose hazardous live parts. Disconnect power between checks
and proceed carefully.
1. Replace any blown fuses and reset anytripped breakers
2. Repair or replace any loose wires or bad connections
3. Inspect AFS for proper location and operation.
1. Check that the access door is not open or ajar.
2. Repair or replace any loose wires or bad connections.
3. Replace defective momentanJ contact switch.
4. Inspect AFS for proper location and operation.
1. Ensure that ON/OFF switch isturned ON.
2. Repair or replace any loose wires or bad connections.
3. Replace defective ON/OFF switch.
4. Inspact AFS for proper location and oparat_on.
1. Remove any objects between adjacent collector plates.
2. Replace corrodedor cardonizedinsuletors.
3. Replace any broken ionizing wires. 4, Wash dirtycells..
1, Replace contaot board ifcontacts are corroded and carbonized.
2. Replace any defective wires.
3. With alcohol, clean dirt build-up on contaefs and let dry thoroughly.
1. Repair or replace any loose wires or bad connections.
1. Replace defective high frequency power supply.
I1 Replace power supply.i Replace transforme_
_32_Wash dirty cell, including any powder build-up on ionizing wires. |
Straighten any bent plates. Replace any broken orloose ionizing wires. I "r-- -
_. _.-_.-=._i_ _ = - _ JRepeat these I
I1. Ensure good contact between cell and contact boards. 1 steps until all
Replace defective contact boards.. } . I problems are I
j_Leliminated J
3O
Page 33
®
CONTACT
O
,...,
EACA
31
Page 34
EACA PARTS LIST
REF. DESCRIPTION NO..
1. Power Tray Assembly (W/AFS) t 20V
1A. Power Tray Assembly (W/AFS) 240V
lB. Power Tray Assembly (W/O AFS)120V
2. High Frequency Power Supply
3. Electronic Air Flow Sensor (Optional)
4. ON/OFF Switch
5. Interlock Switch
6. Cabinet Assembly
7. Pre÷FJJter(2/package)
8. Cell, Ionizing-Collecting
I
9. Ionizing Wire Assembly (Full Set / package)
10 Front Panel Assembly
11. Contact Board Assembly (2/package)
12. Charcoal Filter (optional, not shown)(2/package)
f3. Stepdo,,vn Transformer t20V to 24V (0014 & 0020)
13A. Stepdown Transformer 240V to 24V(2020)
[
14. Insulator (6/package)
T5. Cell Key (not shown)
16. Power Tray Cover
32
Page 35
Two-Year Umited Warranty - This Product is warranted to be free from defects in material and workmanship. IfDefect appears within Two years from the date of original installation, whether or not actual
use begins on that date, product is warranted. Ifproduct installation criteria meets this standard, a new or remanufactured part, at the manufacturer's sole option, to replace any defective part will be provided
without charge for the part itself; PROVIDED the defective part is returned to the distributor through a qualified servicing dealer.
Five-Year Limited Warranty on Power Supply- This Power Supply is warranted to be free from defects in material and workmanship. If Defectappears within Five years from the date of original installation, whether
or not actual use begins on that date, product is warranted. If product installation criteria meets this standard, anew orremanufactured part, at the manufacturer's sole option, to replace any defective part will be provided without charge for the part itself; PROVIDED the defective part is returned to the distributor
through aqualified servicing dealer
Limited Labor Allowance - If service call on this unit must be made in the first 120 days from ohginal data of installation a $25,00 (USD) labor allowance will be given. If Power Supply must be replaces in the first five
years after original installation date a $50.00 (USD) labor allowance will be given.
THIS WARRANTY DOES NOT INCLUDE LABOR OR OTHER COSTS-OTHER THAN THAT SPECIFIED
ABOVE incurred for diagnosing, repairing, removing, installing, shipping, servicing or handling of either
defective parts or replacement parts. Such costs may be covered by a separate warranty provided by the installer.
THIS WARRANTY APPUES ONLY TO PRODUCTS IN THEIR ORIGINAL INSTALLATION LOCATION AND
BECOMES VOID UPON REINSTALLATION.
LIMITATIONS OF WARRANTIES -ALL IMPLIED WARRANTIES (INCLUDING IMPLJED WARRANTIES OF FITNESS FORA PARTICULARPURPOSE AND MERCHANTABlUTY) ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH THE LIMITED WARRANTY IS GIVEN. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WAR RANTY LASTS, SO TH E ABOVE MAY NOT APPLY TO YOU. THE EXPRESSED WARRANTIES MADE JN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE
ALTERED, ENLARGED, OR CHANGED BY ANY DISTRIBUTOR, DEALER, OR OTHER PERSON WHATSOEVER.
ALL WORK UNDER THE TERMS OF THIS WARRANTY SHALL BE PERFORMED DURING NORMAL
WORKING HOURS. ALL REPLACEMENT PARTS, WHETHER NEW OR REMANUFACTURED, ASSUME AS THEIR WARRANT'( PERIOD ONLYTHE REMAINING TIME PERIOD OF THIS WARRANTY.
THE MANUFACTURER WILL NOT BE RESPONSIBLE FOR:
1. Normal maintenance as outlined inthe instaltation and servicing instructions orowners manual including filtercleaning and/or replacement and lubrication.
2. Damage or repairs required as a consequence of faulty installation, misapplication, abuse, improper servicing, unauthorizedalteration or improper operafion.
3. Failure to start due to voltage conditions, blown fuses, open circuit breakers or other damages due to the
inadequacy or interruption of electrical service.
4. Damage as a result of floods, winds, fires, lightning, accidents, corrosive environments or other
con_iaons beyond _e controlof the Manufacture_
5. Partsnotsuppliedordesignatedbythe Manufacturer, ordamagesresulting from theiruse.
6. Manufacturer products installedoutsidethe continental U.S.A., Alaska, Hawaii, and Canada.
7. Electricity or fuel costs or increases in electricity or fuel costs from any reason whatsoever including
add_ona( or unusual useof supplemental elec_c heat.
8. ANY SPECIAL INDIRECT OR CONSEQUENTIAL PROPERTY OR COMMERCIAL DAMAGE OF ANY
NATURE WHATSOEVER, Some states do not allow the exclusion of incidental or consequential
damages, sothe above may notapply to you.
This warrantygives youspecific legal rights, and you may also have other rightswhich may va_j from state
to state.
PartNurnber 155587 005 7/02
Page 36
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obl_jaum,_.
Form No. EACA-1SI / llEACA-14-1 Catalog NO. 03EA-CA0 Printed in U.S.A. 7-02 Replaces: New