Carrier 38MG user guide manual

38MG / 40MA / 40MB Multi-zone Ductless Split System Sizes 18 to 48
Owner's Manual
TABLE OF CONTENTS
PAGE
A NOTE ABOUT SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
MODEL NUMBER NOMENCLATURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
ENVIRONMENTAL NOTICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
OPERATING INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
CARE AND MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
OPERATION TIPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
TROUBLESHOOTING TIPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
NOTE TO EQUIPMENT OWNER:
Please read this Owner’s Information Manual carefully before installing and using this appliance and keep this manual for future reference.
For your convenience, please record the model and serial numbers of your new equipment in the spaces provided. This information, along with the installation data and dealer contact information, will be helpful should your system require maintenance or service.
UNIT INFORMATION
Model # ___________________________________ Serial # ___________________________________
INSTALLATION INFORMATION
Date Installed _____________________________
DEALERSHIP CONTACT INFORMATION
Company Name: _________________________________ Address:_________________________________________ ________________________________________________ Phone Number:__________________________________ Technician Name:_________________________________ ________________________________________________
A NOTE ABOUT SAFETY
Model Numbers
Any time you see this symbol in manuals, instructions and on the unit, be aware of the potential for personal injury. There are three levels of precaution:
DANGER identifies the most serious hazards which will result in severe personal injury or death.
WARNING signifies hazards that could result in personal injury or death.
CAUTION is used to identify unsafe practices which could result in minor personal injury or product and property damage.
NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.
!
PERSONAL INJURY, DEATH AND / OR PROPERTY DAMAGE HAZARD
Failure to follow this warning could result in personal injury, death or property damage.
Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause personal injury or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or service agency must use factory--authorized kits or accessories when modifying this product.
Read and follow all instructions and warnings, including labels shipped with or attached to unit before operating your new air conditioner.
WARNING
System
Tons
1.5 18,000
3 208/230-1
System
Btuh
27,000 36,000 48,000
Volt- Ph @
208/230-1 38MGQC18---3 208/230-12.25
208/230-14
60Hz
Outdoor Model
Number
38MGQD27---3 38MGQF36---3 38MGQF48---3
Model number Nomenclature
40 MA Q B 09 B -- 3
Digi ts 7, 8 i ndica te the syste m's cap aci ty in 100 0 BTU/ Hr
Exam ple : 09 = 9000 B TU/Hr
Maxi mum Number o f fan coil uni ts connect ed to the o utd oor uni t B = 1:1
Digi t 5 ind icate s the system 's type: C = Cool ing only; Q = Heat p ump
Digi t 12 in dicat es voltage 1 = 115/ l/60 3 = 208- 230-1-60 Hz
Digi ts 10 , 11 - blan k
Digi t 9 - Ind oor Fan Coi l Unit Type B = High -Wa ll C = Cass ette D = Duct ed F = Cons ole G = Unde rceiling H = High Wal l Color Var iatio n
- = Outd oor
Digi ts 3 an d 4 repre sent the mod el
The fi rst two digi ts indicat e the equipm ent typ e. 40 = Ind oor unit; 38 = Out door uni
2
CAUTION
Contact an authorized service technician for repair or maintenance of this unit. Contact the installer for installation of this unit. The air conditioner is not intended for use by young children or invalids without supervision. Young children should be supervised to ensure that they do not play with the air conditioner. If the power cord is to be replaced, replacement work shall be performed by authorized personnel only. Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
3
ENVIRONMENTAL NOTICE
When using this air conditioner in the European countries, the follow information must be followed:
DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste
separately for special treatment is necessary.
It is prohibited to dispose of this appliance in domestic household waste. For disposal, there are several possibilities: A) The municipality has established collection systems, where electronic waste can be disposed of
B) When buying a new product, the retailer will take back the old product free of charge.
C) The manufacturer will take back the old appliance for disposal.
D) As old products contain valuable resources, they can be sold to scrap metal dealers.
Wild disposal of waste in forests and landscapes endangers your health when hazardous substances leak into the ground-water and find their way into the food chain.
4
SAFETY PRECAUTIONS
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage.
The seriousness is classified by the following indications.
WARNING
CAUTION
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to property.
Meanings of symbols used in this manual are as shown below.
Never do this.
Always do this.
WARNING
Connect with the power properly.
Otherwise, it may cause electric shock or fire due to heat generation.
excess
Do not modify power cord length or share the outlet with other appliances
It may cause electric shock or fire due to heat generation.
Do not operate or stop the unit by switching on or off the power.
It may cause electric shock or fire due to heat generation.
Do not operate with wet hands or in damp environment.
It may cause electric shock.
Do not damage or use an unspecified power cord.
It may cause electric shock or fire.
Do not direct airflow at room occupants only.
This could damage your health.
Always ensure effective
grounding
No may cause el ectric shock.
.
grounding
Disconnect the power if strange sounds, smell, or
Do not allow water to run into electric parts.
It may cause machine failure or electric shock.
Do not drink water drained from air conditioner.
smoke comes from it.
It may cause fire a nd electric shock.
Use the correctly rated breaker or fuse.
Otherwise risk of fire or electric shock.
It contains co ntaminants and could make y ou sick.
Do not use the power cord close to heating appliances.
It may cause fire and electric shock.
Ventilate room before operating air conditioner if there is a gas leakage from another appliance.
It may cause explosion, fire and, burns.
Always install circuit breaker and a dedicated power circuit.
Failure to install may cause fire and electric shock.
Do not open the unit during operation.
It may cause electric shock.
Do not use the power cord near flammable gas or combustibles, such as gasoline, benzene, thinner, etc.
It may cause an explosion or fire.
Do not disassemble or modify unit.
Doing so may result in unit failure and electric shock.
5
SAFETY PRECAUTIONS
CAUTION
When the air filter is to be removed, do not touch the metal parts of the unit.
Doingsomay cause an injury.
When the unit is to be cleaned, switch off, and turn off the circuit breaker.
Do not clean unit when po wer is on as it may cause fir,electric shock, or it may cause an injury.
Stop operation and close the window in storm or hurricane.
Operation with windows opened may allow wa te r to enter the interior space and soak or damage interior items.
Do not use strong detergent such as wax or thinner. Use a soft cloth for cleaning.
Appearance may be deteriorated due to change of product color or scratching of its surface.
Do not c lean the air conditioner with water.
Water may enter the unit and degrade the insulation. It may cause an electric shock.
Do not put a pet or house plant where it will be exposed to direct air flow.
This could injure the pet or plant.
Do not p lace obstacles around air-inlets or inside of air-outlet.
It may cause failure of teh appliance or ac cident.
Ensure that the installation bracket of the outdoor appliance is not damaged due to prolonged exposure.
If bracket is damaged, there is risk of damage due to falling of unit.
Ventilate the room well when used together with a s tove, etc.
An oxygen shortage may occur.
Do not use for special purposes.
Do not use this air cond­itioner to preserve preci­sion devices, food, pets, plants, and art objects. It may cause deterioration of quality, etc.
Turn off the main power switch when not sing the unit for a long time.
It may cause failure of product or fire.
Always insert the filters securely. C lean filter once every two weeks.
Operation without filters may cause failure.
u
Do not place heavy object on the power cord and take care so that the cord is not compressed.
Do n o t ope rate yo ur air c ondit i on er in a wet r oo m suc h as a bathro om or la un dry room.
This a pplia nc e can be use d by children ag ed fro m 8 years and abo ve a nd pe r sons with r educe d phy si c a l, s ensor y o r me n tal capab i lities o r lac k of exp erience
and kn owledge i f t hey h a ve be en given s uperv isio n o r in st ruction conce r ning u se of the a pp lian ce i n a safe way and un d e rstan d the haz ar d s invo l ved . Childre n s ha l l not pla y with the ap p lianc e . Clean i n g an d user main t en an ce sha ll not be performed by childre n
witho u t supe rvision .
Use caution when unpacking and installing. Sharp edges could cause injury.
C hi ldr e n sho u l d be s uper v ised to ens ure th ey do n ot pla y with th e app liance .
This ap plianc e is not in tended f or use by per so n s ( in clud ing chil dren) with reduce d physic al, sensory o r men ta l ca p abili t ies, or l a ck of ex perie nce a nd knowledge , unle ss th e y h ave been given supe rvision or inst r ucti on conc er nin g use o f the appliance by a p erson responsible for t heir sa f ety.
If water enters the unit, turn the unit off and disconnect the power , contact a qualified service technician.
There is danger of fire or electric shock.
If t h e su p ply co rd is da mage d , i t must b e re pla ced by th e ma nufac turer, its ser v ice ag ent or s imil a r ly quali fi ed pe rsons in ord e r to a v oid a hazard.
6
OPERATING INSTRUCTIONS
Identification of parts
Indoor unit
One - five
One - fo ur
One -three
One - twin
Indoor unit
1. Panel frame
2. Rear air intake grille
3. Front panel
4. Air Purifying filter and Air filter(behind)
5. Horizontal louver
6. LCD display window
7. Vertical louver
8. Manual control button(behind)
9.
Remote controller holder
Outdoor unit
10. D rain hose, refrigerant connecting pipe
11. C onnectiv e cable
12. S top valve
13. F an hood
Outdoor unit
13
9
11
12
Display wind ow
NOTE: The display window o n the air co ndit ioner y ou purc hase d may lo o k like one of the following:
10
7
Signal recepto r
(2)
(3)
OPERATING INSTRUCTIONS
OPERATION display
Displays when the air conditioner is in operation.
AUTO operation dis play
Displayed during the Auto operation .
DEFROST operation display
(For H eating and Cooling model o nly):
Displays when the air conditioner starts defrosting automatically or when the warm air control feature is activated in the heating operation.
TIMER displ ay
Displays during the Timer operation.
CLEAN AIR display(opt ional)
Ion
Displays when the CLEAN AIR feature is activated.
(4 )
(5 )
defros tauto t ime r ion
(6 )
(7 )
TURBO operation display
Displays when a user selectsthe TURBO function
heating
DIGITAL DISPLAY
on t h e cooling operation or on t h e
operation.
Displays the current setting temper­ature when the air conditioner is in operation.
FAN SPEED display
Displays the selected fan speed: LOW( ), MED( ) and HIGH( ).
Fre quency indication lamp
This display is separated into five zo nes. The zones illuminate based on the compressor curr ent frequency. For e xampl e, higher frequency ill uminates more zones.
8
Loading...