Carlo Gavazzi UC 80 CND 60 . P M1 TR Data Sheet

Specifications are subject to change without notice (19.07.2005) 1
Ultrasonic Diffuse, Dual Transistor Outputs Type UC 80 CND 60 . P M1 TR
Product Description
Ultrasonic sensor Housing style Housing size Housing material Housing length Detection principle Sensing distance Output type Output configuration Connection Remote teach
Type Selection
Housing Connection Rated operating Outputs Ordering no. dimensions dist. (S
n
)
80 x 80 x 50 mm Plug M12, 5 pin 600-6000 mm 2 x PNP, NO/NC UC 80 CND 60 PP M1 TR 80 x 80 x 50 mm Plug M12, 5 pin 600-6000 mm 2 x NPN, NO/NC UC 80 CND 60 NP M1 TR
Ordering Key
UC80CND60PPM1TR
A self-contained multi func­tion diffuse ultrasonic sensor with a sensing range of 600 to 6000 mm. 2 switching outputs - easily set up for 3 different switching modes and adjusted by teach-in ­makes it ideal for level con­trol tasks in a wide variety of vessels. A sturdy one-piece ABS housing provides the
perfect packaging for the sofisticated microprocessor controlled and digitally fil­tered sensor electronics. Excellent EMC performance and precision are typical features of this sensor based on true distance measurement.
Technical Data
Rated operational volt. (Ue) 15 to 30 VDC (ripple included) Ripple 10% Output current (Ie) max. 500 mA (continuous) No-load supply current (Io) 80 mA Protection Short-circuit, transients and
reverse polarity
Rated insulation voltage > 1 kV Output 2 PNP or NPN open collector
outputs, NO or NC
Power-on delay 200 ms Voltage drop (Ud) < 0.5 V Off-state current (Ir) < 10 µA Teach-in Set point adjustment NO/NC selection
Switching modes selection
Indication Set points, 2 LEDs yellow
Echo, 1 LED green
Rated operating distance 600 - 6000 mm Operating frequency 0.5 Hz Carrier frequency 80 kHz
Response time 70 ms (target speed 1 m/s
in beam direction) 700 ms (step response)
Hysteresis (H) (differential travel) Programmable Temperature compensation Ye s Beam angle Ambient temperature
Operating and Storage -15° to +70°C (5° to +158°F)
Environment
Overvoltage category II (IEC 60664/60664A,
60947-1)
Pollution degree 3 (IEC 60664/60664A,
60947-1)
Degree of protection IP 65 (IEC 60529, 60947-1)
Housing material ABS Connection Plug M12, 5-pin
Cables for plug (M1) CONM15 series
Weight 300 g CE-marking Yes
• Square 80 mm ABS housing
• Sensing distance: 600 - 6000 mm
• Remote Teach by wire
• Outputs: 2 multi function switching outputs PNP or NPN, NO or NC
• Setup of "Normal Switching", "Window" or "Adjustable Hysteresis" function
• Power supply: 15 to 30 VDC
• 8° beam angle
• Protection: Short-circuit, reverse polarity, transients
• Protection degree IP 67
• M12 plug, 5 pin
2 Specifications are subject to change without notice (19.07.2005)
UC 80 CND 60 . P M1 TR
Switching Operation
Distance
P1 P2
Distance
P1 P2
Distance
P1 P2
Distance
NO Characteristics
NC Characteristics
Normal Switching Operation
Windows Function
Hysteresis Adjustment
The following 3 different modes of the switching outputs can be selected:
I Normal switching function II Window function III Adjustable hysteresis
All these functions may be programmed/taught by means of the Teach-in input (pin 5) present in the connector. Each mode has a unique indication using the Echo, P1 and P2 LEDs. The programming/Teach-In procedure is shown in the following flow diagram:
Teach in of switching output SP1
Position P1 Switching output can be either NO or NC.
Teach in of switching output SP2
Switching output can be either NO or NC.
Window function / Selection of Hysteresis Mode
SP1 is switching when object is between P1 and P2. SP2 is switching when the object is NOT between P1 und P2. Hysteresis adjustment of set points at P1 Distance between P1 and P2 determines the hyteresis of the switching outputs. SP1 has
NO and SP2 has NC characteristics.
Teach-In for 8 sec
14 sec
20 sec
Normal function:
The Echo LED is ON when an echo is received (alignment LED). P1 and P2 LEDs are indicating status of the switching outputs.
Echo P1 P2
Green Yellow Yellow
Wiring Diagram
Teach-In for
14 sec
Teach-In for
20 sec
Teach input is active when 5 BE wire is connected to Ground (3 BU).
Teach input is active when 5 BE wire is connected to Ground (3 BU).
PNP
SP1
SP2
1 BN
5 PK (GY)
4 BK
2 WH
3 BU
43
5
2
1
SP 1
SP 2
SP 1
SP 2
P 1 P2
P 2
P1
D ist anc e
NPN
SP 1
SP 2
SP 1
SP 2
1 BN
SP1
SP2
4 BK
2 WH
5 PK (GY)
3 BU
P1 P2
43
5
2
1
P1 P2
D ist anc e
Loading...