Carlo Gavazzi UC 80 CND 40 ER Data Sheet

Specifications are subject to change without notice (26.10.01) 1
Ultrasonic Diffuse, RS 485 Output Type UC 80 CND 40 ER
• 80 x 80 x 43 mm polyester housing
• Sensing distance: 400-4000 mm
• Output: RS 485
• 8° beam angle
• Alignment LED
• Protection: Short-circuit, reverse polarity, transients
• Protection degree IP 67
Product Description
Ultrasonic sensor Housing style Housing size Housing material Housing length Detection principle Sensing distance Output type Output configuration
Type Selection
Housing Connection Rated operating Ordering no. dimensions dist. (S
n
) RS 485 output
80 x 80 x 43 mm Screw terminals 400-4000 mm UC 80 CND 40 ER
Ordering Key
UC 80 CND 40 ER
A diffuse ultrasonic sensor with a sensing of 400-4000 mm with an analog RS485 communication output. Both the housing and the sensor transducer are designed for tough environment. A high carrier frequency secures a
precise measuring and high noise immunity. Due to use of microprocessor control the digital filtering make the sen­sor very immune against most electromagnetic interferences and enables synchronisation in an easy way.
Specifications
Rated operational volt. (Ue) 19 to 30 VDC
(ripple included)
Ripple 10%
No-load supply current (I
o
) 50 mA
Protection Short-circuit, transients and
reverse polarity
Rated insulation voltage > 1 kV Output RS 485
Resolution min. 20 mm Linearity 0.5% Repeatabilty 0.5% Temperature deviation 1%
Indications
Status “Occupied” LED1, yellow Alignment LED2, green
Rated operating distance
400-4000 mm
Carrier frequency 120 kHz Beam angle Temperature compensation Yes Ambient temperature
Operating
0° to +70°C (32° to +158°F)
Storage
-20° to +80°C (-4° to +176°F)
Degree of protection IP 67 (Nema 1, 3, 4, 6, 13) Housing material
Polyester PBTP
Dimensions 80 x 80 x 43 mm Connection Screw terminals, PG 13.5 Weight 250 g CE-marking Yes
2 Specifications are subject to change without notice (26.10.01)
UC 80 CND 40 ER
Installation Hints
Relief of cable strain Protection of the sensing face Switch mounted on mobile carrierTo avoid interference from inductive voltage/ current peaks, separate the prox. switch power cables from any other power cables, e.g. motor, contactor or solenoid cables
Incorrect
Correct
The cable should not be pulled
A proximity switch should not serve as mechanical stop
Any repetitive flexing of the cable should be avoided
DimensionsWiring Diagram
Detection Range
400 4000
+40
-40
mm
mm
Guaranteed detection of a target 100 x 100 mm
Possible detection of a large target
1 +24 VDC
3 GND
4 RS485-A
2 RS485-B
Blue
Black
Pink
Brown
Loading...