Ultrasonic
Diffuse, Analogue and Digital Output
Types UA30EAD......TI
• Cylindrical M30 Stainless Steel INOX
AISI 316L housing
• Sensing distance: 350-3500 mm
• Power supply: 12 (15) to 30 VDC
• Outputs: 0-10 VDC or 4-20 mA and one switching
output NPN or PNP.
• Linearity error 1%
• Repeatability 1%
• Beam angle. ±7°
• Protection: Short-circuit, reverse polarity and
overvoltage
• Protection degree IP 67
• 2 m cable or M12 plug
Product Description
A family of diffuse ultrasonic sensors in Stainless steel
housing and with sensing
range from 350-3500 mm
with a resolution as low as
2.0 mm.
The sensor contains both an
analogue and a digital output.
The output is either 0-10V or
4-20 mA and the digital output
NPN or PNP, NO or NC which
forms a windows detection.
The sensor is the ideal choice
for distance measurement,
level measurement, diameter
measurement or loop control.
Due to use of microprocessor control the digital filtering
makes the sensor immune to
most electromagnetic interferences.
Ordering Key
Ultrasonic sensor
Housing style
Housing size
Housing material
Housing length
Detection principle
Sensing distance
Output type
Output configuration
Connection
Teach-in
UA30EAD35NGM1TI
Type Selection
Housing Connec- Rated operating Analog Digital output Ordering no.
diameter tion dist. (Sn) Output NPN/PNP
M30 Plug M12 350-3500 mm 4-20 mA NPN UA 30 EAD 35 NG M1 TI
M30 Cable 350-3500 mm 4-20 mA NPN UA 30 EAD 35 NG TI
M30 Plug M12 350-3500 mm 0-10 V NPN UA 30 EAD 35 NK M1 TI
M30 Cable 350-3500 mm 0-10 V NPN UA 30 EAD 35 NK TI
M30 Plug M12 350-3500 mm 4-20 mA PNP UA 30 EAD 35 PG M1 TI
M30 Cable 350-3500 mm 4-20 mA PNP UA 30 EAD 35 PG TI
M30 Plug M12 350-3500 mm 0-10 V PNP UA 30 EAD 35 PK M1 TI
M30 Cable 350-3500 mm 0-10 V PNP UA 30 EAD 35 PK TI
Specifications
Rated operating distance (Sn) Reference target: 1 mm
metal rolled finish, size
400 x 400 mm.
350 - 3500 mm
Blind zone ≤ 350 mm
Repeatability 1%
Linearity error 1%
Beam angle ±7˚
Sensitivity
Push-button P1 (longest setpoint)
P2 (shortest setpoint)
Resolution 2 mm
Temperature drift 0.1%/˚C @ -20˚ to +70˚ C
Temperature compensation Yes
Hysteresis (H) Min. 1%
Specifications are subject to change without notice (01.04.2014) 1
Rated operational voltage (UB)
NG or PG versions 12 to 30 VDC
NK or PK versions 15 to 30 VDC
(ripple included)
Ripple (U
No-load supply current (Io) 50 mA @ UB max
Output current continuous
digital output (Ie)
Max. load capacity 100 nF 100 mA
Output current short-time
digital output (I)
Max. load capacity 100 nF 100 mA
Minimum operational current
digital output (Im) 0.5 mA
OFF-state current digital
output (Ir) 10 μA
) ≤ 5%
rpp