Carlo Gavazzi UA 30 EAD Part Numbering Designation

Ultrasonic Diffuse, Analogue and Digital Output
Types UA30EAD......TI
• Cylindrical M30 Stainless Steel INOX AISI 316L housing
• Sensing distance: 350-3500 mm
• Power supply: 12 (15) to 30 VDC
• Linearity error 1%
• Repeatability 1%
• Beam angle. ±7°
• Protection: Short-circuit, reverse polarity and overvoltage
• Protection degree IP 67
• 2 m cable or M12 plug
Product Description
A family of diffuse ultrason­ic sensors in Stainless steel housing and with sensing range from 350-3500 mm with a resolution as low as
2.0 mm. The sensor contains both an analogue and a digital output. The output is either 0-10V or 4-20 mA and the digital output NPN or PNP, NO or NC which
forms a windows detection. The sensor is the ideal choice for distance measurement, level measurement, diameter measurement or loop control. Due to use of microproces­sor control the digital filtering makes the sensor immune to most electromagnetic inter­ferences.
Ordering Key
Ultrasonic sensor Housing style Housing size Housing material Housing length Detection principle Sensing distance Output type Output configuration Connection Teach-in
UA30EAD35NGM1TI
Type Selection
Housing Connec- Rated operating Analog Digital output Ordering no. diameter tion dist. (Sn) Output NPN/PNP
M30 Plug M12 350-3500 mm 4-20 mA NPN UA 30 EAD 35 NG M1 TI M30 Cable 350-3500 mm 4-20 mA NPN UA 30 EAD 35 NG TI M30 Plug M12 350-3500 mm 0-10 V NPN UA 30 EAD 35 NK M1 TI M30 Cable 350-3500 mm 0-10 V NPN UA 30 EAD 35 NK TI M30 Plug M12 350-3500 mm 4-20 mA PNP UA 30 EAD 35 PG M1 TI M30 Cable 350-3500 mm 4-20 mA PNP UA 30 EAD 35 PG TI M30 Plug M12 350-3500 mm 0-10 V PNP UA 30 EAD 35 PK M1 TI M30 Cable 350-3500 mm 0-10 V PNP UA 30 EAD 35 PK TI
Specifications
Rated operating distance (Sn) Reference target: 1 mm metal rolled finish, size 400 x 400 mm. 350 - 3500 mm
Blind zone ≤ 350 mm Repeatability 1% Linearity error 1% Beam angle ±7˚ Sensitivity
Push-button P1 (longest setpoint)
P2 (shortest setpoint) Resolution 2 mm
Temperature drift 0.1%/˚C @ -20˚ to +70˚ C Temperature compensation Yes Hysteresis (H) Min. 1%
Specifications are subject to change without notice (01.04.2014) 1
Rated operational voltage (UB) NG or PG versions 12 to 30 VDC NK or PK versions 15 to 30 VDC (ripple included)
Ripple (U No-load supply current (Io) 50 mA @ UB max Output current continuous
digital output (Ie) Max. load capacity 100 nF 100 mA
Output current short-time digital output (I) Max. load capacity 100 nF 100 mA
Minimum operational current digital output (Im) 0.5 mA
OFF-state current digital output (Ir) 10 μA
) ≤ 5%