Precision DIN-rail
mounted timing relays
for any industrial
application
Sprecher + Schuh’s new RZ7-FS precision electronic timing relays offer 19
different output functions applicable
to all types of industrial control.
In addition to standard
and OFF-Delay relays, the series also
includes many specials such as an
Delay that operates without supply
voltage. Various timing ranges from
0.05 seconds to 60 hours are available,
with many relays offering multi-time
setting capability in the same device.
ON-Delay
OFF-
Solid state accuracy and
reliability
Except for their hard silver contacts, all
RZ7-FS timing relays are built with solid
state electronics and controlled by a mi
croprocessor. ey are accurate to within
0.2 percent. eir ruggedness and high
level of accuracy is due to the thorough
testing of function, timing characteristics
and surge voltage strength performed on
each device prior to shipment.
In addition, RZ7-FS relays function
reliably from 15% under rated oper
ating voltage to 10% over rated voltage
(AC). Voltage tolerance is even greater
in DC applications.
-
-
Multiple functions and
timing ranges in one relay
e RZ7-FSM combines eight separate
timing functions (plus ON and OFF
functions) into one device. In addition, ten timing ranges are individually
selectable from 0.05 seconds to 60
hours. ese special relays reduce in
ventories and are ideal for maintaining
remote installations where stocking
several different timing relays would
not be practical.
-
Many safety and
G
Timing Relays
Control &
RZ7-FS
The new multifunction RZ7-FSM Electronic
Timing Relay provides eight different timing
functions and ten different timing ranges.
Eliminates additional relays
e standard RZ7-FS is supplied with
one single pole double throw
contact within a compact case only
22.5mm wide. If more contacts are
required, several relays are available
that provide two separate, electrically
isolated SPDT contacts within the
same narrow footprint. Output two is
selectable as an instantaneous contact,
which can eliminate the need for aux
iliary relays in complex installations.
ese two pole relays can also be used
with an external potentiometer for
remote time setting.
(SPDT)
convenience features
• Every RZ7 accepts a broad range of
AC and DC supply voltages without
special ordering.
• Each relay is equipped with an LED
that indicates four output status
conditions.
• Finger and back of hand protection
to IP40.
• Terminals are captive and supplied
in the open position.
-
• All RZ7’s can be surface mounted, rail
mounted, or mounted directly on our
family of CA7/CS7 or CA4/CS4 devices.
• RZ7 relays can be mounted in any
plane.
• Terminals, setting knob and LED’s are
all accessible from the front of the unit.
• RZ7 Timing Relays are very compact,
measuring approximately 1" x 3" x 4".
G39
G
Control &
Timing Relays
RZ7-FS
Electronic Timing Relays
Quick Selection Guide
Single Function Timing Relays
RZ7-FSA3AU23
TypeFunction
A On-Delay
B Off-Delay
C On and Off-Delay
D One Shot / Watchdog
E Fleeting Off-Delay
F Symmetric flasher starting with a pulse
G Symmetric flasher starting with a pause
I On-Delay pulse generator
J On-Delay (pulse controlled)
K One Shot / Watch Dog (pulse controlled)
L Impulse Converter
RZ7-FSQ3QU18
Type
Q Off-Delay Without Supply Voltage
Function
Contacts
All functions:
3 One single pole
double throw contact
Functions A & B only:
4
Two single pole
double throw contacts ➋
(Available with Time
Range “U” only. Not
available with “U18”
supply voltage)
Contacts
3 One single pole
double throw contact
4
Two single pole double
throw contacts ➋
Time Ranges
A 0.05…1 second
B 0.15… 3 seconds
C 0.5…10 seconds
D 1.5…30 seconds
E 0.05…1 minute
F 0.15…3 minutes
G 0.5…10 minutes
H 1.5…30 minutes
I 0.05…1 hour
J 0.15…3 hours
K 0.5…10 hours
L 3.0…60 hours
U 0.05s…60 hours ➊
Time Ranges
Q 0.15s…10 minutes ➊
Supply Voltages
Standard:
U23 24…48VDC
24…240V 50/60Hz
Special Order:
U18* 24…240VAC or DC
A40 346…440V 50/60Hz ➌
Z12 12VDC
* Not available with Time Range “U”
Supply Voltages
U18 24…240VAC or DC
Series RZ7-FS
Multi-Function Timing Relay
RZ7-FSM3UU23
TypeFunction
M Multi-Function
Eight single functions plus ON & OFF function (for installation/maintenance)
- On-Delay
- Off-Delay
- On and Off-Delay
- One Shot / Watchdog
- Fleeting Off-Delay
- Symmetric flasher starting with a pulse
Contacts
3 One single pole
double throw contact
4
Two single pole
double throw contacts ➋
Time Ranges
U 0.15…60 hours
Supply Voltages
➊
Standard:
U23 24…48VDC
24…240V 50/60Hz
Special Order:
U18 24…240VAC or DC
A40 346…440V 50/60Hz ➌
Z12 12VDC
Special Function Timing Relays
RZ7-FSH3UU23
TypeFunction
H Repeat Cycle Timer (Flasher)
Includes four separate functions
- Supply voltage controlled, output
starts with a pause
- Supply voltage controlled, output
starts with a pulse
- Pulse controlled, output starts with a
pause
- Pulse controlled, output starts with a
pulse
Contacts
All functions:
3 One single pole
double throw contact
Time Ranges
For equal timing of pulse
and pause
U 0.05s…60 hours ➊
For separate timing of
pulse and pause
V 2 x 0.05s…60 hours
➊
Supply Voltages
Standard:
U23 24…48VDC
24…240V 50/60Hz
Special Order:
A40 346…440V 50/60Hz ➌
Z12 12VDC
RZ7-FSY2CU23
Type
Y Wye Delta Timing Relay
➊
Multi-time setting range. See Technical Section for specific time settings.
➋
Second output selectable as timed or instantaneous.
Function
Contacts
2 Two normally open
contacts
Time Ranges
C 0.5…10 seconds
D 1.5…30 seconds
E 0.05…1 minute
F 0.15…3 minutes
G 0.5…10 minutes
➌
Timers with supply voltage code A40 (346...440VAC) are not UL listed.
Supply Voltages
Standard:
U23 24…48VDC
24…240V 50/60Hz
Special Order:
A40 346…440V 50/60Hz ➌
G40
Discount Schedule B
L/+
A2
N/-
A1
18 16
15
B1
Z1 Z2
28 26
25
24 22
21
S
L/+
A2
N/-
A1
18 16
15
B1
S
L/+
A2
N/-
A1
18 16
15
B1
Z1 Z2
28 26
25
24 22
21
L/+
A2
N/-
A1
18 16
15
28 26
25
Electronic Timing Relays
L/+
A2
N/-
A1
18 16
15
L/+
A2
N/-
A1
18 16
15
Series RZ7-FS
RZ7-FS Timing Relays – Single Function, One and Two Pole
Functional
Description
ON-Delay Timing Relay (A)
When supply voltage is applied, output
contact(s) change state after time
delay t.
OFF-Delay Timing Relay (B)
When control contact “S” closes, output
contact(s) change state immediately. When
control contact S opens, output contact(s)
change state after time delay
supply voltage required on terminals A1/A2.
Note: Control pulse duration minimum 50ms
(AC) - 30ms (DC).
t. Constant
Functional
Diagram
Terminal
ArrangementTypeCatalog NumberPrice
➋
➋
G
Timing Relays
Control &
• One SPDT contact
• Single timing range
• One SPDT contact
• Multi-timing range
(from 0.05s to 60h)
• Two SPDT contacts ➋
• Multi-timing range
(from 0.05s to 60h)
➌
➋
➊
➊
➌
• One SPDT contact
• Single timing range
• One SPDT contact
• Multi-timing range
(from 0.05s to 60h)
• Two SPDT contacts ➋
• Multi-timing range
(from 0.05s to 60h)
➋
RZ7-FSA3✱U23
RZ7-FSA3UU2364
➍
RZ7-FSA4UU2384
➍
RZ7-FSB3✱U23
RZ7-FSB3UU2364
➍
RZ7-FSB4UU2384
➍
61
RZ7-FS
61
• One SPDT contact
Off-Delay Without Supply Voltage (Q)
When supply voltage is applied, output
contact(s) change state immediately. When
supply voltage is removed, output contact(s)
change state after time delay
➏
t.
Ordering Instructions
• Specify catalog number
• Replace (✱) with Timing Range Code
Refer to table
at right
Supply Voltage
Single Function RZ7-FS...U23 timers (except RZ7-FSQ) accept supply voltages of 24…48VDC and 24…240VAC (RZ7-FSQ accepts
24…240VAC or DC). Other voltages are available by special order.
See Quick Selection Guide on page G40 for details or contact your
Sprecher + Schuh representative for information.
➊
For timing control, a voltage other than the supply voltage can also be used.
• Multi-timing range
(from 0.15s to 10min)
• Two SPDT contacts
• Multi-timing range
(from 0.15s to 10min) ➎
Timing Range Codes
Timing Range
0.05…1 sec
0.15…3 sec
0.5…10 sec
1.5…30 sec
0.05…1 min
0.15…3 min
0.5…10 min
1.5…30 min
0.05…1 hour
0.15…3 hour
0.5…10 hour
3.0…60 hour
Code
A
B
C
D
E
F
G
H
I
J
K
L
RZ7-FSQ3QU18121
➎
RZ7-FSQ4QU18141
RZ7-FS two pole timing relay
➋ Output two is selectable as an instantaneous contact by sliding a switch on the
faceplate.
➌ Bridge or potentiometer 10kΩ, min. 0.25W (low voltage) for external time setting.
➍ Timing range is screwdriver selectable from the faceplate. Timing range selections
include those found in the Timing Range Code chart.
Discount Schedule B
➎ Timing range is screwdriver selectable from the faceplate. Exact timing ranges can be
found in the Technical Section.
➏ Due to shock during shipment, the state of the contacts should be verified before
initial use.
G41
A2
N/-
18 16
15
L/+
A1
B1
S
RZ7-FS Timing Relays – Single Function, One Pole
L/+
A2
N/-
A1
18 16
15
L/+
A2
N/-
A1
18 16
15
L/+
A2
N/-
A1
18 16
15
B1
S
G
Functional
Description
Functional
Diagram
Electronic Timing Relays
Series RZ7-FS
Terminal
ArrangementTypeCatalog NumberPrice
Control &
Timing Relays
RZ7-FS
ON and OFF-Delay Timing Relay (C)
When control contact “S” closes, output
contact changes state after time delay
When control contact S opens, output contact
changes state again after time delay
Constant supply voltage required on terminals
A1/A2.
Note: Closure duration of S must be greater
than t.
One Shot / Watchdog Relay (D)
When supply voltage is applied, the output
contact changes state for time period
Fleeting OFF-Delay Timing Relay (E)
When control contact “S” is pulsed, output
contact changes state for time period
Note: Control pulse duration minimum 50ms
(AC) - 30ms (DC).
Symmetric Flasher Starting
With A Pulse (F)
When supply voltage is applied, output
contact changes state immediately and then
repeatedly changes after every time period
continuing until supply voltage is removed.
t.
t.
t.
t.
➊
• One SPDT contact
• Single timing range
• One SPDT contact
• Single timing range
➊
• One SPDT contact
• Single timing range
• One SPDT contact
t,
• Single timing range
RZ7-FSC3✱U23
RZ7-FSD3✱U23
RZ7-FSE3✱U23
RZ7-FSF3✱U23
68
68
68
68
Ordering Instructions
• Specify catalog number
• Replace (✱) with Timing Range Code
Refer to table
at right
Supply Voltage
Single Function RZ7-FS...U23 timers (except RZ7-FSQ) accept supply voltages of 24…48VDC and 24…240VAC (RZ7-FSQ accepts
24…240VAC or DC). Other voltages are available by special order.
See Quick Selection Guide on page G40 for details or contact your
Sprecher + Schuh representative for information.
➊
For timing control, a voltage other than the supply voltage can also be used.
G42
Discount Schedule B
Timing Range Codes
Timing Range
0.05…1 sec
0.15…3 sec
0.5…10 sec
1.5…30 sec
0.05…1 min
0.15…3 min
0.5…10 min
1.5…30 min
0.05…1 hour
0.15…3 hour
0.5…10 hour
3.0…60 hour
Code
A
B
C
D
E
F
G
H
I
J
K
L
RZ7-FS one pole timing relay
A2
N/-
18 16
15
L/+
A1
B1
S
L/+
A2
N/-
A1
18 16
15
B1
S
L/+
A2
N/-
A1
18 16
15
L/+
A2
N/-
A1
18 16
15
Electronic Timing Relays
A2
N/-
18 16
15
L/+
A1
B1
S
Series RZ7-FS
RZ7-FS Timing Relays – Single Function, One Pole
Functional
Description
Symmetric Flasher Starting
With A Pause (G)
When supply voltage is applied, output
contact changes state after time period
then repeatedly changes again after every
period t, continuing until supply voltage is
removed.
On-Delay Pulse Generator (I)
When supply voltage is applied, output
contact changes state after time period
Output contact changes state again after
0.5 seconds.
On-Delay (pulse controlled) (J)
When control contact “S” is pulsed, the out
put contact changes state after time period
One Shot / Watchdog
(pulse controlled) (K)
When control contact “S” closes, the output
contact changes state immediately. After the
last pulse of contact S, the output contact
changes state after time delay
t and
t.
t.
t.
Functional
Diagram
Terminal
ArrangementTypeCatalog NumberPrice
• One SPDT contact
• Single timing range
• One SPDT contact
• Single timing range
➊
• One SPDT contact
• Single timing range
➊
• One SPDT contact
• Single timing range
RZ7-FSG3✱U23
RZ7-FSI3✱U23
RZ7-FSJ3✱U23
RZ7-FSK3✱U23
68
68
68
68
G
Timing Relays
Control &
RZ7-FS
Impulse Converter (L)
When a pulse is applied to control contact
“S”, the output contact changes state im
mediately for time period
during timing period t have no further effect.
Note: The period t is not dependent on the
length of the control pulse. Control pulse
duration minimum 50ms (AC) - 30ms (DC).
t. Pulses received
-
Ordering Instructions
• Specify catalog number
• Replace (✱) with Timing Range Code
Refer to table
at right
Supply Voltage
Single Function RZ7-FS..U23 timers (except RZ7-FSQ) accept
supply voltages of 24…48VDC and 24…240VAC (RZ7-FSQ accepts
24…240VAC or DC). Other voltages are available by special order.
See Quick Selection Guide on page G40 for details or contact your
Sprecher + Schuh representative for information.
➊
• One SPDT contact
• Single timing range
Timing Range Codes
Timing Range
0.05…1 sec
0.15…3 sec
0.5…10 sec
1.5…30 sec
0.05…1 min
0.15…3 min
0.5…10 min
1.5…30 min
0.05…1 hour
0.15…3 hour
0.5…10 hour
3.0…60 hour
Code
A
B
C
D
E
F
G
H
I
J
K
L
RZ7-FSL3✱U23
RZ7-FS one pole timing relay
68
➊ For timing control, a voltage other than the supply voltage can also be used.
Discount Schedule B
G43
G
L/+
A2
N/-
A1
18 16
15
B1
Z1 Z2
28 26
25
24 22
21
L/+
A2
N/-
A1
18 16
15
B1
Z1 Z2
28 26
25
24 22
21
S
L/+
A2
N/-
A1
18 16
15
B1
Z1 Z2
28 26
25
24 22
21
L/+
A2
N/-
A1
18 16
15
B1
Z1 Z2
28 26
25
24 22
21
L/+
A2
N/-
A1
18 16
15
B1
Z1 Z2
28 26
25
24 22
21
S
L/+
A2
N/-
A1
18 16
15
B1
Z1 Z2
28 26
25
24 22
21
L/+
A2
N/-
A1
18 16
15
B1
Z1 Z2
28 26
25
24 22
21
S
L/+
A2
N/-
A1
18 16
15
B1
Z1 Z2
28 26
25
24 22
21
S
Control &
Timing Relays
RZ7-FS
Electronic Timing Relays
Series RZ7-FS
RZ7-FS Timing Relays – Multi-Function, One and Two Pole
The RZ7-FSM multifunction relay combines eight timing functions
plus ON and OFF functions (for installation and maintenance). Each
timing function and timing range is selectable from the face of the
relay with a screwdriver actuated knob. The RZ7-FSM offers the
following timing functions:
On-Delay Off-Delay
On and Off-Delay
Fleeting Off-Delay
On-Delay Pulse Generator
ON Function (see below) With a Pulse
OFF Function (see below)
The two pole RZ7-FSM4 offers two separate, electrically isolated
single pole double throw (SPDT) contacts which allow applications in
complex installations without additional auxiliary relays. This series
may also be operated remotely via an external potentiometer.
One Shot / Watchdog
Impulse Converter
Symmetric Flasher Starting
• One SPDT contact
• Multifunction, multi-timing range
relay (from 0.05s to 60h)
• Two SPDT contacts ➋
• Multifunction, multi-timing range
relay (from 0.05s to 60h)
➍
RZ7-FSM3UU23101
RZ7-FSM4UU23121
➍
On-Delay (A) Off-Delay (B)
➋
➌
On and Off-Delay (C) One Shot / Watchdog (D)
➊
➋
➋
➌
Fleeting Off-Delay (E) Symmetric Flasher Starting With a Pulse (F)
ON-Function OFF-Function LED display indicates function
➊
➌
➌
➌
➋
➋
➋
➊
➌
➋
Output in rest position, no timing
Output in rest position, time running
Output in operation position, no timing
Output in operation position, time running
Supply Voltage
The RZ7-FSM timer accepts supply voltages of 24…48VDC and
24…240VAC. Other supply voltages are available by special order.
See Quick Selection Guide on page G40 for details or contact your
Sprecher + Schuh representative for information.
G44
Discount Schedule B
➊
For timing control, a voltage other than the supply voltage can also be used.
➋ Output two is selectable as an instantaneous contact by sliding a switch on the
faceplate
➌ Bridge or potentiometer 10kΩ, min. 0.25W (low voltage) for external time setting.
➍ Function selection and timing range is screwdriver selectable from the faceplate. Exact
timing range selections can be found in Technical Information.
Electronic Timing Relays
L/+
A2
N/-
A1
18
16
15
B1
S
L/+
A2
N/-
A1
18
16
15
B1
S
L
A2
N
A1
18
28
17
Y ∆
L/+
A2
N/-
A1
18
16
15
B1
S
L/+
A2
N/-
A1
18
16
15
B1
S
Series RZ7-FS
RZ7-FS Timing Relays – Special Function, One Pole
Functional
Description
Wye-Delta Timing Relay (Y)
When supply voltage is applied, output
contact Y closes for time period
period t, plus a fixed time period tu, (5065ms) output contact Δ closes.
Repeat Cycle Timer (H) - (Flasher)
The Repeat Cycle Timer offers four different
operating characteristics within the same
relay. Depending on how the unit is wired,
cycles are initiated either by supply voltage
being applied or by a pulse from control
contact “S”. Regardless of the activation
method, each cycle may begin with a pause
or a pulse.
The RZ7-FSH3U relay sets the pulse and
pause durations equally. The RZ7-FSH3
allows individual time settings of pulse
and pause. Both relays offer multiple time
settings between 0.05s and 60h, selectable
in ten increments.
t. After time
V
Functional
Diagram
Supply voltage controlled,
output starts with a pause
Supply voltage controlled,
output starts with a pulse
Pulse controlled,
output starts with a pause
Terminal
ArrangementTypeCatalog NumberPrice
• Two single pole N.O.
contacts
• Single timing range
• One SPDT contact
• Multi-timing range
(from 0.05s to 60h)
Equal setting of pause and
➊
➊
pulse
Individual setting of pause
and pulse
RZ7-FSY2✱U23
➋
RZ7-FSH3UU23
RZ7-FSH3VU23
81
81
81
G
Timing Relays
Control &
RZ7-FS
Pulse controlled,
output starts with a pulse
Ordering Instructions
• Specify catalog number
• Replace (✱) with Timing Range Code
Refer to table
at right
Timing Range Codes
Timing Range
0.5…10 sec
1.5…30 sec
0.05…1 min
0.15…3 min
0.5…10 min
Code
C
D
E
F
G
Supply Voltage
These timers accept supply voltages of 24…48VDC and
24…240VAC. A supply voltage of 346…440VAC is also available by
special order. See Quick Selection Guide on page G40 for details or
contact your Sprecher + Schuh representative for information.
➊
For timing control, a voltage other than the supply voltage can also be used.
➋ Timing range is screwdriver selectable from the faceplate. Exact timing range
selections can be found in Technical Information.
Discount Schedule B
RZ7-FSY one pole timing relay
G45
G
Accessories - Field Installable
Series RZ7-FS Electronic Timing Relays
Accessories
AccessoryDescriptionCatalog NumberPrice
Control &
Timing Relays
RZ7-FS
Setting Knob With Scale -
For time setting without tools.
Panel Mounting Adaptor -
For surface mounting RZ7-FS/FE
timing relays.
Dovetail joint -
for fitting all timers to CA7/CS7 and
CA4/CS4 devices
DIN-rail - 2 meter lengths (≈ 6' 6")
Top Hat, low profile (price per rail
Top Hat, high profile (price per rail)
RZ7-FSK5
26.506.221-014
25.944.201-031.30
3F
3AF
17
26
Marking Systems
ComponentDescription
Label Sheet –
1 sheet with 105 self-adhesive paper
labels each, 6 x 17mm
Marking Tag Sheet -
1 sheet with 160 perforated paper
labels each, 6 x 17mm. To be used with
transparent cover.
Transparent Cover -
To be used with Marking Tag Sheets.
Tag Carrier -
For marking with Series V7 Clip-on
Tags.
➊
Minimum order quantity is one package of 100. Price each x 100 = total price.
Pkg.
Qty. Catalog Number
CA7-FMS
1
CA7-FMP
1
100
CA7-FMC
➊
100
CA7-FMA2
➊
Price
Each
1
1
.10
.10
G46
Discount Schedule B
Technical Data
Timing Characteristics (according to VDE 0435, Part 2021)
Timing ranges for
RZ7-FSM-A, B, C, D, E, F, I, & L(1s)0.05…1 sec
RZ7-FSH(3s)0.15…3 sec
RZ7-FSQ(2.5s)0.15…2.5 sec
Setting accuracy
Repeatability
ToleranceVoltage:
Power Supply
Supply voltages24…48VDC and 24…240VAC, 50/60Hz
Voltage toleranceAC: -15%... +10%
Power consumptionAC: 5VA at 240V
Time energized
Reset time50ms
Voltage interruption
Input ImpedanceRelay On: 3k-13k ohms
Cable length
(supply voltage control)
Pulse Control (B1)
Impulse duration
Input voltageSupply voltage range
Input current1 mA
Max. Leakage Current400 micro Amps
Cable length
Outputs
Type of outputsRelay contacts: hard silver
Maximum admissible
operating voltage
Dielectric Coil to contact Withstand
Voltage
Switching capacity
Current Ith: (AC1)8A (5A for RZ7-FSQ)
Power:2000VA
Short circuit resistance10 A gL (fast blow fuse)
(10s)0.5…10 sec
(1mn)0.05…1 min
(3mn)0.15…3 min
(10mn)0.5…10 min
(1h)0.05…1 hour
(3h)0.15…3 hours
(10h)0.5…10 hours
(60h)3…60 hours
(10s)0.5…10 sec
(80s)4…80 sec
(10mn)0.5…10 min
±5% of full scale value
±0.2% of the setting values
±0.001%/%ΔU
Temperature:
(dual voltage)
12VDC
24…240V AC or DC (universal voltage)
346…440VAC, 50/60Hz
DC: -20%... +20%
DC: 0.5W at 24V
100%
≤20ms without reset (supply voltage)
Relay Off: 0.7k-4k ohms
250 meters (800 ft.) max.
≥50ms (AC), ≥30ms (DC)
max. 250 m (800 ft.) without parallel load
between B1 & A2
max. 50 m (160 ft.) with load (
B1 & B2
Alternating current: 440VAC
5,000 V
according to IEC947-5-1:
3A/440VAC (inductive load, AC14)
3A/250VAC (inductive load, AC15)
1A/24VDC (inductive load, DC13)
according to UL 508:
1.5A/250VAC (B300)
3A/120VAC (B300)
±0.025%/°C
<3kΩ
) between
Technical Information
Series RZ7-FS Electronic Timing Relays
Life expectancy (electrical)4 million ops. at 1A/250VAC, cos
Life expectancy (mechanical)30 million operations
General Data
Insulation Characteristics
EMC/Interference ImmunityPerformance of following requirements:
EMC/EmissionElectromagnetic fields according to EN 55 022:
Safe isolationAccording to VDE 106, part 101
Climatic withstand56 cycles (24h) at 25…40°C and 95% relative
Vibration resistance4 g in 3 axis at 10…500 Hz, test FC according
Shock resistance50 g according to IEC 68-2-27
Protection classEnclosure:
Weight
Approvals/StandardsUL, C-UL up to 240VAC, Germanischer Lloyd, CE
Ambient temperatureOpen:
ConnectionsScrew terminal - M3.5 for Pozidrive No.2, Phillips and slotted screws
Rated tightening torque -
Mounting– Snap-on mounting (35mm DIN-rail)
Relays
DisposalSynthetic material without dioxin according to EC/
StandardsEN 60947-1, EN 60947-5-1, EN 50081-1, IEC 947,
Wire Size -
Finger Protection - According to VDE 0106
0.2 million ops. at 6A/250VAC, cos
1.5 million ops. at 1A/250VAC, cos
0.3 million ops. at 3A/250VAC, cos
0.5 million ops. at 6A/24VDC, resistive
2 million ops. at 4A/24VDC, resistive
2 million ops. at 0.2A/230VDC, resistive
1 million ops. at 0.4A/24VDC, L/R = 20ms
1 million ops. at 0.2A/110VDC, L/R = 20ms
1 million ops. at 0.1A/230VDC, L/R = 20ms
2 kVAC/50 Hz test voltage according to VDE
and 6 kV 1.2/50 μs surge voltage according to IEC
947-1 between all inputs and outputs
- Surge capacity of the supply voltage
according to IEC1000-4-5: 4 kV 1.2/50
- Burst according to IEC 1000-4-4: 6 kV/ 6/50ns
- ESD discharge according to IEC 1000-4-2:
- Contact 8 kV, air 8 kV
- Electromagnetic HF field according to IEC
and conducted electromagnetic HF
according to IEC 801-6: Level 3
Class B
humidity according to IEC 68-2-30 and IEC 68-2-3.
IP40
Terminal: IP20 according to IEC 947-1
100g
Enclosed:
Storage
No.2 suitable for power screwdriver.
0.8 Nm (max. 1.2 Nm) - [8.8 lb-in]
Dual-chamber system for terminal cross-sections
of 1 x 0.5mm2 (solid) or 2 x 2.5mm2 (flexible with
sleeve), AWG 20…14.
Series RZ7 Timing Relays have a “relative scale” setting knob numbered 0 to 1.0. ink about
this as 0 to 100% of the relay’s built-in time range. Example: To set an RZ7-FS timing relay
(with a 0.05 to 1 minute range) to activate after 25 seconds:
1) Divide the desired activation time (25 seconds)
by the maximum time limit of the relay (60
seconds).
25
÷ 60 = .416
2) Rotate the setting knob to just past the .4 mark.
ϕ = 1
ϕ = 1
ϕ = 0.3
ϕ = 0.3
0435
μs
801-3
signal
[surface mounting in
contacts
G
Timing Relays
Control &
RZ7-FS
Discount Schedule B
G47
G
9
4,3
22,5
4,3
75
35
5,5
58
17
12
13
2
Control &
Timing Relays
RZ7-FS
Dimensions
Series RZ7-FS Electronic Timing Relays
Dimensions
Series RZ7-FS Timing Relays (one and two pole)
• Dimensions are in millimeters
• Dimensions not intended for manufacturing purposes
RZ7-FS (1 SPDT contact) RZ7-FS (2 SPDT contacts)
Panel Mount Adaptor (26.506.221-01)
• Dimensions are in millimeters
• Dimensions not intended for manufacturing purposes
G48
Discount Schedule B
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.