CaptiveAire DF5-48 Parts List

CONFIDENTIAL
Sheet: 1 of 2
NOTES:
Gas Type: Natural or LP
ITEM NUMBER
Description
Quantity
1
1-1/2" Quick Seal
1
2
1-1/2" x 4" Nipple
1
3
1-1/2" 90° Elbow
4
4
1-1/2" x 1-1/2" Nipple
12
5
1-1/2" Union
3
6
1-1/2" x 1-1/2" x 1/2" Tee
3
7
N/A
N/A
8
1-1/2" K3A682T Solenoid Valve
1
9
1-1/2" V4055A1007 Hydraulic Actuator and V5055A1020 Valve
1
10
1-1/2" x 2-1/2" Nipple
1
11
Maxitrol 1-1/2" MR212D Modulating Valve
1
12
1/2" Male x 1/4" Female Reducer
2
13
1-1/2" Manual Ball Valve
1
14
1-1/2" x 10" Nipple
1
BILL OF MATERIALS
Inlet Pressure: 7 in. w.c. - 5 psi. Max. Natural Gas Manifold Pressure: 5 in. w.c. Max. LP Manifold Pressure: 2.5 in. w.c.
External Ball Valve Shipped Loose in Control Cabinet
External High Gas Pressure Regulator Required when gas pressure exceeds 5 psi.: P/N = 243-8-2-1.5-OR-1-30 (25 psi. max.)
18
17
4
3
15 N/A N/A 16 N/A N/A 17 1-1/2" Female x 2" Male Adapter 1 18 48" Dual Fuel Midco Burner 1 19 N/A N/A 20 N/A N/A 21 1/4" Brass Elbow 1 22 3/8" Male x 1/4" Female Reducer 1 23 325-3x3/8 Pilot Gas Regulator 1 24 3/8" 90° Elbow 1 25 3/8" Close Nipple (1-1/2") 1 26 3/8" x 2" Nipple 1 27 3/8" Pilot Shut Off Valve 1 28 1/2" Male x 3/8" Female Reducer 1 29 3/8" x 3" Nipple 1 30 Pyroseal Furnace Cement (AX # 2220) 31 1-1/2" x 7-1/2" Nipple 1 32 1-1/2" x 14" Nipple
42026 3/8 U-Bolt, washer, and locknuts (2 Places)
5/16 Bolt, washer, and locknuts (2 Places)
M1067H1M Bracket 2 Places
5/16 x 3/4 Self Tapping Sheet Metal Screws 2 PLaces
1
Note:
1) Burners Riveted together with 3/16" rivets.
2) Burner Cement needed at all casting joints only.
Material: N/A Blank Size: N/A x N/A Weight: N/A lbs
Part Number: N/A MACOLA/AX Number: Drawing Name: DF 5 48 inch Gas Train Drawn By: Parent Assembly: DF 5
Item # 9 is replaced by V4055D1019 and V5055C1059 for Proof of Closure Applications
Item # 30 (not shown) used for burners built in house.
8
5
Pilot Regulator
Pilot Tap
9
3
2
Main Regulator
1
Pilot Solenoid, Regulator,
44 9/16"
& Manual Valve Location for MN State Requirements Regulator P/N: 325-3x3/8 Solenoid P/N: V4046C1021
(2x)
12
4
21
22
4
6
25
23
24
26
4
6
Install Manifold Support Here
Unless Otherwize Specified Dimensions are in Inches.
Standard Tolerances are: Fractions: Decimal:
Angles:
1/16 .XX .05 .XXX .015
1
Low Fire By-Pass
11
27
29
28
10
31
5
5
14
13
3
3
32
4
6
4 Install Manifold Support Here
Sheet: 2 of 2
CONFIDENTIAL
NOTES:
ITEM NUMBER
Description
Quantity
1
1-1/2" Quick Seal
1
2
1-1/2" x 4" Nipple
1
3
1-1/2" 90° Elbow
4
4
1-1/2" x 1-1/2" Nipple
10
5
1-1/2" Union
3
6
1-1/2" x 1-1/2" x 1/2" Tee
3
7
1/4" Square Head Pipe Plug
2
8
1-1/2" K3A682T Solenoid Valve
1
9
1
10
1-1/2" x 2-1/2" Nipple
1
11
Maxitrol 1-1/2" MR212D Modulating Valve
1
12
1/2" Male x 1/4" Female Reducer
2
13
1-1/2" Manual Ball Valve
1
14
1-1/2" x 10" Nipple
1
BILL OF MATERIALS
Gas Type: Natural or LP Inlet Pressure: 7 in. w.c. - 5 psi. Max. Natural Gas Manifold Pressure: 5 in. w.c. Max. LP Manifold Pressure: 2.5 in. w.c.
17
External Ball Valve Shipped Loose in Control Cabinet
External High Gas Pressure Regulator Required when gas pressure exceeds 5 psi.:
15 N/A N/A 16 N/A N/A 17 1-1/2" Female x 2" Male Adapter 1 18 48" Dual Fuel Midco Burner 1 19 1/4" x 4" Nipple 4 20 1/4" x 1/4" x 1/4" Tee 2 21 1/4" Brass Elbow 1 22 3/8" Male x 1/4" Female Reducer 1 23 325-3x3/8 Pilot Gas Regulator 1 24 3/8" 90° Elbow 1 25 3/8" Close Nipple (1-1/2") 1 26 3/8" x 2" Nipple 1 27 3/8" Pilot Shut Off Valve 1 28 1/2" Male x 3/8" Female Reducer 1 29 3/8" x 3" Nipple 1 30 Optional Antunes HGP-A M1 Pressure Switch 1 31 Optional Antunes LGP-A M1 Pressure Switch 1 32 Pyroseal Furnace Cement (AX # 2220) 33 1-1/2" x 7-1/2" Nipple 34 1-1/2" x 14" Nipple
42026 3/8 U-Bolt, washer, and locknuts (2 Places)
5/16 Bolt, washer, and locknuts (2 Places)
M1067H1M Bracket 2 Places
5/16 x 3/4 Self Tapping Sheet Metal Screws 2 PLaces
Pilot Solenoid, Regulator, & Manual Valve Location for MN State Requirements Regulator P/N: 325-3x3/8 Solenoid P/N: V4046C1021
1 1
P/N = 243-8-2-1.5-OR-1-30 (25 psi. max.)
Item # 9 is replaced by V4055D1019 and V5055C1059 for Proof of Closure Applications
Item # 32 (not shown) used for burners built in house.
Note:
1) Burners Riveted together with 3/16" rivets.
2) Burner Cement needed at all casting joints only.
Material: N/A Blank Size: N/A x N/A Weight: N/A lbs
Part Number: N/A MACOLA/AX Number: Drawing Name: DF 5 48 inch Gas Train Drawn By: Parent Assembly: DF 5
Pilot Regulator
3
(2x)
(2x)
20
(2x)
19
(2x)
12
(2x)
4
Install Manifold Support Here
Unless Otherwize Specified Dimensions are in Inches.
Standard Tolerances are: Fractions: Decimal:
Angles:
5
2
1
19
7
4
1/16 .XX .05 .XXX .015
1
21
6
Pilot Tap
8
31
Main Regulator
23
22
24
25
4
6
Low Fire By-Pass
18
9
44 9/16"
26
27
29
28
10
11
4
33
3
5
30
14
5
13
3
34
3
6
4
4
Install Manifold Support Here
Loading...