Canon LV S3 - SVGA LCD Projector Specification

0.5” SVGA LV-S3
SERIAL FUNCTIONAL SPECIFICATION
Page 1/21
-CONTENT-
1. Overview
2. Interface Specification
3. Connection
4. Notes for Communication
5. Functional Execute Command Table
6. Status Read Command Table
7. Functional Execution Command Table
7.1 Format
7.2 When the command pipelining is needed
7.3 Transfer Example
7.4 Operation Requirements
7.5 Power ON Command
7.6 Power OFF Command (Quick POWER OFF)
7.7 Power OFF Command
7.8 Computer Command
7.9 Video Command
7.10 Volume + Command
7.11 Volume – Command
7.12 Audio Mute ON Command
7.13 Audio Mute OFF Command
7.14 Video Mute ON Command
7.15 Video Mute OFF Command
7.16 Screen Normal Size Command
7.17 Screen Wide Size Command
7.18 Image Standard Command
7.19 Image High contrast Command
7.20 Image Cinema Command
7.21 Image Custom Command
7.22 Menu ON Command
7.23 Menu OFF Command
7.24 Display Clear Command
7.25 Brightness + Command
7.26 Brightness – Command
7.27 Image (Toggle) Command
Page 2/21
7.28 Power Management Ready Command
7.29 Power Management OFF Command
7.30 Power Management Shut Down Command
7.31 D.Zoom + Command
7.32 D.Zoom - Command
7.33 Video Auto Command
7.34 Video Video Command
7.35 Video S-Video Command
7.36 Pointer Right Command
7.37 Pointer Left Command
7.38 Pointer Up Command
7.39 Pointer Down Command
7.40 Enter Command
7.41 Freeze ON Comman d
7.42 Freeze OFF Comman d
7.43 Computer Analo g RGB Command
7.44 Computer Scart Command
7.45 Computer Component Command
7.46 Page Up Command
7.47 Page Down Command
7.48 Auto PC Adj. Command
7.49 Presentation Timer Command
7.50 Keystone Up Command
7.51 Keystone Down Command
8. State Read Command
8.1 Format
8.2 Transfer Example
8.3 Status Read Command
8.4 Input Mode Read Command
8.5 Lamp Time Read Command
8.6 Setting Read Command
Page 3/21
1. Overview
1.1 This Specification defines projector control commands for LV-S3 (0.5”SVGA model).
1.2 The projector control commands are for controlling projector through RS232C from a computer.
2. Interface Specification Specification
Shynchro system Asynchronous Transmission Speed 9600 / 19200 Data Length 8 bit Parity None Stop Bit 1 Flow Control None
1. Transfer rate: initial setting value is 19200
2. Transfer rate can be changed by service mode
3. Connection
The serial cable that is specified in the specification as below must be used for a connection to a computer and a projector.
PC Projector
COM No. 1  Control Port
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8
CD
SG
RXD
TXD
DTR
DSR
RTS CTS
RING
D-Sub 9 Pin Mini-DIN 8 Pin
Page 4/21
4. Notes for Communication
4.1 The projector command is defined one command/one line that starts “C” and ends carriage return (0x0D).
4.2 The projector starts decoding after the carriage return.
4.3 There are two types of command, functional execution commands and state read commands.
Example of Functional Execution Command: “C05” [CR]
Example of State Read Command: “CR0” [CR]
4.4 It clears information of accepting buffer as following terms.
4.4.1 When a projector receives LF(0xoA) or EOF(0x1A)
4.4.2 When it takes more than one second to receive on e command. (Until the projector receives the carriage return after the projector receives the first data.)
4.5 When control command pipelining, after the response, wait interval of time as below.
1.COMMAND such as ”VOLUME +/-“Æ 100ms
2.Other COMMANDÆ 500ms
4.6 Wait at least 500 ms after the response, when status read command pipelining.
4.7 Do not issue any command before the Response. When there is no response after 5 seconds, issue next command.
4.8 It takes about 7 seconds for internal initialization after plugging in AC. During this time, it cannot process command. Do not issue any commands.
4.9 7 seconds after StandBy or Power ON, even when a projector receives a command, a computer receives acceptable response, but it does not execute for internal initialization and lamp lighting process. However, Status Read Commands are executed after 500ms when they receive acceptable response.
4.10 About performance during processing count down or cooling down.
When a projector receives After Stand By or Power ON, Even when a projector receives a command, a computer receives response to accept the command, but it does not execute for internal initialization and lamp lighting process. However, Status Read Commands are executed.
4.11 About performance when changing INPUT.
After receiving INPUT switching command, when receiving commands between 5 seconds from starting the switching to completing the switching, a computer receives acceptable command, but it is not executed. However, status read commands are executed after a computer receives response to
accept the command, after 500ms. Response for Status Read Command after accepting has different characters. See ”Status Read Command Table”.
Page 5/21
4.12 Characters for commands must be Capital (A - Z).
5. Functional Execution Command Table
Command Item Command Item
C00 Power ON C2A Power Management Ready C01
Power OFF Quick Power OFF
C2B Power Management OFF C02 Power OFF C2E Power Management Shut down C05 Computer C30 D.Zoom + C07 Video C31 D.Zoom ­C09 Volume + C32 Video Auto
C0A Volume - C33 Video Video C0B Audio Mute ON C34 Video S-Video C0C Audio Mute OFF C3A Pointer Right C0D Video Mute ON C3B Pointer Left C0E Video Mute OFF C3C Pointer Up C0F
Screen Normal size(4:3)
C3D Pointer Down C10
Screen Wide size(16:9)
C3F Enter C11 Image Standard C43 Freeze ON C12 Image High contrast C44 Freeze OFF C13 Image Cinema C50 Computer Analog RGB C14 Image Custom C51 Computer Scart
C1C Menu ON C54 Computer Component C1D Menu OFF C59 Page Up C1E Display Clear C5A Page Down
C20 Brightness + C89 Auto PC Adj. C21 Brightness - C8A Presentation Timer C27
Image Toggle
C8E Keystone Up
C8F Keystone Down
6. Status Read Command Table
Command
Function CR0 Status Read CR1 Input Mode Read CR3 Lamp Time Read CR4 Setting Read CR6 Temp Read
Page 6/21
7. Functional Execution Command Table
7.1 Format
1. PC issues a command as below form at “C” [CR]
COMMAND
Command: 2 characters (See Functional Execution Command Table)
2. A projector decodes received data and sends a return result after being ready to receive next command. [ACK] [CR]:0x06,0x0DWhen received functional execution commands. “?” [CR]: When cannot read received data
7.2 When the command pipelining is needed
When some functions need command pipelining , the performance is the same as the remote control’s performance.
1. System: issue any commands every 100ms after receiving response
2. When receiving the same command continuously with 120ms, the function is executed
for 120ms from that moment.
3. When receiving the same command continu ously, with 120ms, the fun ction is executed
for 120ms form the moment.
4. The next command is not issued after 120ms, and the execution is stopped.
5. If the projector receives other incoming commands within 120ms, the execution is
stopped.
7.3 Transfer Example
Change to Video mode with Basic Command
 Command
PC Æ Projector “C” ”0” ”7” CR
Projector Æ PC ACK CR Processing (A few ms--1s)
Page 7/21