Basic Serial Command Functional Specification Page 3 of 19
1. Overview
1.1. This specification defines Projector control commands for LV-7225/7220/LV-5220.
1.2. The Projector control commands are for controlling Projector through RS232C from a computer.
2. Serial Interface Specification
2.1. Transfer Specification
Item Specification
Shynchro system Asynchronous
Transmission Speed 9600 / 19200
Data Length 8 bits
Parity None
Stop Bit 1
Flow Control None
1). Transfer rate: initial setting value is 19200.
2). Transfer rate can be changed by service mode.
2.2. Connection
Dedicated serial cable that comes with the projector must be used for a connection to a computer and
a Projector.
PC Projector
COM 1 SERVICE Port
CD
RXD
TXD
DTR
SG
DSR
RTS
CTS
RING
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
(Dsub-9 pin) (Mini DIN-8 pin)
Basic Serial Command Functional Specification Page 4 of 19
3. Notes for Communication
3.1. The Projector command is defined one command/one line that starts “C” and ends carriage return
(0x0D).
3.2. There are two types of command, functional execution commands and state read commands.
Example of Functional Execution Command
“C05” [CR]
Example of State Read Command
“CR0” [CR]
3.3. When it takes more than one second to receive on command, it clears information of buffer.
(Until the Projector receives the carriage return since the Projector has received the first data)
3.4. When a computer keeps sending some command; it must wait sending next command after 100ms
when the computer receives the return command.
More than 100ms
Command
PC → Projector “C” “0” “7” CR Next Command
Projector → PC ACK CR
Response
(A few ms- 5s)
3.4.1. When a computer sends next command before receiving a return command, the Projector may
not operate properly.
3.4.2. When there is no response after 5 seconds, issue next command.
3.5. It takes about 5 seconds for internal initialization after plugging in AC.
During this time, it cannot process command. Do not issue any commands.
3.6. Response for status read command after accepting has different characters.
See 7. Status Read Command.
3.7. Characters for commands must be capital (A - Z).
Basic Serial Command Functional Specification Page 5 of 19
4. Functional Execution Command Table
Command Item Command Item
C00 Power On C2A Power Management Ready
C01 Power Off (Quick Power Off) C2B Power Management Off
C02 Power Off C2E Power Management Shut down
C05 Computer 1 (MC/W/N) C30 D.Zoom +
C06 Computer 2 C31 D.Zoom C07 Video C32 Video Auto
C09 Volume + C33 Video Video
C0A Volume - C34 Video S-Video
C0B Mute On C3A Pointer Right
C0C Mute Off C3B Pointer Left
C0D No Show On C3C Pointer Up
C0E No Show Off C3D Pointer Down
C0F Screen Normal Size (4:3) C3E Mouse Right Click
C10 Screen Wide Size (16:9) C3F Enter
C11 Image Standard C43 Freeze On
C12 Image High contrast C44 Freeze Off
C13 Image Cinema C50 Computer 1 Analog RGB
C14 Image Custom C52 Computer 1 DVI (PC Digital)
C18 Image Blackboard (Green) C53 Computer 1 DVI ( HDCP)
C1C Menu On C59 Page Up
C1D Menu Off C5A Page Down
C1E Display Clear C89 Auto PC Adj.
C20 Brightness + C8A Presentation Timer
C21 Brightness - C8E Keystone Top
C24 Computer 2 Component C8F Keystone Bottom
C25 Computer 2 RGB C90 Keystone Right
C26 Computer 2 SCART C91 Keystone Left
C27 Image (Toggle)
C28 On Start Enable
C29 On Start Disable
5. Status Read Command Table
Command Function Note
CR0 Status Read
CR1 Input Mode Read
CR3 Lamp Time Read
CR4 Setting Read
CR6 Temp. Read