Program mode 13
Factory default settings
Your settings
Settings 14
Change between C° and F°
Restore factory default settings
Teaching the thermostat ID code
to the control unit
Frequently asked questions 15
Quick reference table 16
Back Up Switch 17
Service 18
Battery type: 2 X AA batteries
Battery life : approximately 12 months
Transmission frequency: 433.92 Mhz
Dimensions: 140MM x 80mm x 20mm
Page 1.
ROOM
TIME
A/M
T
DOWN
Cannon
UP
OK
PWR
P
QUICK START GUIDE
This Remote Thermostat is a room thermostat and to function correctly it
should be located in the same room as the heater within personal
comfort zone.
To start heater.
Select “PWR” and “OK” buttons and press them together (then release).
Select Auto or Manual by pressing “A/M” button (then release).
The heater will only operate if the actual room temperature is lower
than the required temperature.
Manual Mode:
Press “A/M” Button toselect “Manual” mode.
The required temperature can be selected by using ‘UP ’ or ‘DOWN ’
buttons.
Room temperature is shown at top of screen.
Selected temperature shown at mid screen.
Automatic Mode
Press “A/M” Button to select “Auto” mode.
Set current time and date. (See setting time and date later in manual.)
The thermostat is factory set with the default settings shown below and
will operate at settings indicated. If you wish to change these times or
temperatures see the Programming section later in manual.
Automatic Factory default settings
Time Period Start Time Heat Temperature (°C)
Wake up. 6.00 am 20 °C
Away. 8.30 am 7 °C
Coming home. 5.00 pm 21 °C
Sleep. 10.30 pm 7 °C
The room will be maintained at set temperature during set period.
21°C
20°C
7°C
6.00AM
8.30AM
5.00PM
10.30PM
6.00AM
Factory default settings
At any time during the automatic program period, the temperature can be
increased or decreased by pressing the “UP” or “DOWN” buttons.
Page 2.
SAFETY WARNINGS
Do not place clothing or other flammable material on or near the heater.
Keep curtains, clothing, furniture and other flammable materials at least
900mm from front and sides of the heater.
At the owners discretion curtain clearances can be less than 900mm as
long as they are restrained from the front, top and sides of the heater.
The manufacturer takes no responsibility if curtain clearance is less than
900mm and not restrained.
For full safety warning information, Refer to Heater User Instructions.
CAUTION: The thermostat has already been programmed with a
unique code. Do not attempt to teach the RF Thermostat ID code
unless instructed by the manufacturer.
This appliance is not intended for use by persons
(including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction
concerning use of the appliance by a person responsible
for safety. Children should be supervised to ensure that
they do not play with the appliance.
Features of your thermostat model heater:
This heater features a safety interlock mode to prevent accidental or
inappropriate activation of the hand held remote control unit. It requires
both “PWR”and “OK” buttons be pressed at the same time to turn on the
controller.
If the controller is turned on and there is a requirement for heating, the
heater will start up on Low Fire and Low Fan and operate for approximately
3 minutes.
The heater will then go to your preset desired temperature functions on
the remote controller
Once the selected room temperature has been reached, the heater will
go to Low Fire and Low Fan.
The full description on the operation of the heater is described in more
detail in the following section.
Page 3.
Features of your thermostat model heater:
Auto mode cycle.
The heater on start will operate on Low Fire and fan for approx 3 minutes.
The heater will then go to your preset desired settings on Remote Thermostat.
(Auto or Manual)
As the preset temperature is reached, the heater will go to Low Fire and
Low Fan. If the preset temperature is exceeded, the burner is
extinguished and the fan will run on at low setting for approximately 3 min.
If room temperature is still higher than preset temperature, the heater will
stop. Once room temperature drops below preset temperature, the heater
will resume operation and continue the program cycle..
This feature is dependant upon the preset programmed temperature and
where the thermostat is located in the room. (See diagram below)
The heater can be set with your personal settings including temperature,
start and stop times and days of week.
(see programming section for setting temperatures and operating times.)
Manual mode cycle
The heater on start will operate on Low Fire and fan for approx 3 minutes.
The heater will then go to your preset desired settings on remote thermostat.
As the preset temperature is reached, the heater will go to Low Fire and
Low Fan. When the heater preset temperature is exceeded, the burner is
extinguished and the fan will run on at low setting for approximately 3 min.
If room temperature is still higher than preset temperature the heater will
stop. Once room temperature drops below preset temperature, the heater
will resume operation and continue the program cycle..
When heater is shut down, fan will continue to operate on low for a further
period of 3 - 4 min to assist cooling down of the heater (common to Manual
and Auto cycles).
Personal comfort zone
Heater
Avoid locating remote
thermostat directly in front
of the heater
Wall bracket.
(Supplied)
2 screws.
(Not supplied)
Thermostat should be located within the personal comfort zone of the room.
(This is dependant on room layout and heater positioning.)
The remote can also be wall mounted using the bracket supplied.
Page 4.
Thermostat LCD
Full display
ROOM
1
SET
6
TIME
7
8
SU MO TU WE TH FR SA
PROG MANUAL AUTO
9
ROOM
TIME
2
4
10
11
AM
PM
AM
3
LCD Display features.
1. Temperature of Room in (C or F)
5
2. Transmitting indicator
3. Battery low indicator
4. Fan operating and speed
5. Fire indicator(low, medium or high)**
6. Selected Temperature in C or F)
7. Time of day (in AM or PM)
8. Day of week
9. Programming mode
10. Manual mode
11. Automatic mode
** Although a medium Fire is displayed it is not
available on this heater, it is actually operating
on High Fire when displayed.
Initial Display on set up.
The display when the thermostat is
initially turned on or when batteries are
replaced shows;
Current room temperature;
default clock display;
Default day of the week display.
Page 5.
MO
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.