This heater is approved for use with Natural and Propane gases.
Please leave instructions with the owner
Contents
Contents2
Warranty3
Safety warnings4-5
❍ What to do if you smell gas
❍ Warnings
❍ Standards
User instructions6-8
❍ Operating instructions
❍ Cleaning
Heater specifications9
Installation instructions10-12
❍ Clearances
❍ Installation into a masonry fire place
❍ Sealing
Gas connection13-14
❍ Fuel bed and log installation
Gas control15-16
❍ Gas pressure point
❍ Gas pressure sdjustment
Service instructions17
❍ General
❍ To replace the gas control
❍ To replace the fan
❍ To replace the electronic controller
❍ To remove the burner and electrodes
❍ To check pressures
Trouble shooting18-19
❍ Connections
❍ Electric wiring diagram
❍ Authorised service agents
2
Warranty
The Cannon appliance is warranted against defects in materials
and workmanship for a period of one, (1) year from its date of
original purchase, for residential use in Australia.
Warranty service, which includes parts and labour for the replacement or repair of defective parts, is available through Cannon
Authorised Service Agencies. (Please refer to the list of authorised
service agents in this manual.)
Consumers are responsible for service person’s travel outside normal service areas (approximately seventy (70k) radius from the
nearest Cannon dealer’s location), local cartage, and normal maintenance as described in this manual.
Any product subjected to misuse, abuse, negligence, accident or
alteration will have its warranty voided. The defacement of serial
plate will have it’s warranty voided.
If installation is not carried out in accordance with manufacturer’s
instructions, this warranty may be void.
The customer must keep their “Tax Invoice” as proof of purchase of
this product and compliance certificate as proof of required installation.
Model number: ______________________________________
Serial number: _______________________________________
Date of manufacture: _________________________________
Date installed: _______________________________________
Sampford and Staff Pty Ltd.
421 Smith Street
Fitzroy, Vic, 3065
Tel: (03) 9418 5888
Don’t risk your appliance warranty
Only a licensed person will give you a Compliance Certificate, showing that the work complies with all the relevant
standards.
And only a licensed person will have insurance protecting
their workmanship for 6 years.
So make sure you use a licensed person to install this appliance and ask for your Compliance Certificate to ensure the
manufacturers appliance warranty will be honoured.
3
Safety Warnings
Please read this manual before installing and using the heater.
What to do if you smell
gas
Warnings
1. Turn OFF the main gas supply.
2. Extinguish any open flame.
3. Open windows.
4. Do not touch electrical switches.
5. Do not use your telephone.
6. Call your gas supplier immediately from a neighbour’s phone.
1. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to other
sections of this manual for correct procedures, or consult with
place of purchase, a licensed plumber, a gas supplier or
service agent listed in this manual.
2. Due to high temperatures the room heater should be located
out of traffic and away from:
•Furniture and draperies,
•Combustible materials,
•Gasoline and other flammable liquids,
Do not place clothing or other flammable material on or near
the heater.
3. Keep curtains*, clothing, furniture and other flammable materials at least 900mm from front and sides of the heater.
* At the owner’s discretion curtain clearance can be less than
900mm as long as they are restrained from the front, top and
sides of the heater. The manufacturer takes no responsibility if
curtain clearance is less than 900mm and not restrained.
4. Children and adults should be alerted to the hazard of high
surface temperature and should take care to avoid burns or
clothing ignition.
Young children should be carefully supervised when they are
in the same room as the heater.
5. Never attempt to burn paper or any other material in the
heater.
6. Do not spray aerosols in the vicinity of this appliance while it
is in operation.
7. If removed the glass window must be put back onto the unit
prior to operating the heater.
8. Installation and repairs should be performed by a licensed
service person only, refer to back of brochure for service
number.
4
9. For installation into a non-combustible fireplace, ie: masonry
or brick or into a mock fireplace, i.e. timber or plasterboard,
the chimney and base should be of sound construction and be
free from cracks and holes (to ensure that sufficient flue draught
can be generated).
NOTE: WHEN INSTALLING INTO A MOCK FIREPLACE A
MOCK FIREPLACE HEATER MUST BE USED.
Mock fireplace model no’s: CANTIBM & CANTIBMLP.
10. The heater must be properly installed in a working chimney or
connected to a venting system. Operation of this heater, when
not connected into a working chimney or a properly installed
and maintained venting system can result in carbon monoxide
(CO) poisoning and possible death.
11. The appliance should be inspected prior to use, with regular
inspections (annually) to be made by a licensed service person. It is important that circulating air passageways of the
appliance be kept clean, dirt and lint free, for a safe and
efficient operation of the heater.
12. On first lighting your heater a smell may occur due to it’s new
condition. This is quite normal and will disappear after a few
hours use at the maximum control position.
Important:
WHEN THIS HEATER IS OPERATING, THE GLASS FRONT IS HOT.
A safety guard conforming to AGA requirements is available for
this heater. It is an optional extra, which may be fitted to the heater
to reduce the risk of fire or injury from burns. Its fitting is recommended when there are children present. For permanent protection
of young children or the infirm, an optional mesh guard is recommended. Call your retailer or authorised service agent for further
details.
Standards
This appliance meets the following standards:
Standards Australia: AS 3100
AS 5601/AG 601
AS 4553/AG 103
5
User instructions
Operating instructions
1. Plug the power cord into the wall socket and turn on the power
to the heater, see figure 1. Refrain from using an extension
cord.
1
2. For control lay-out refer to figure 2
2
3. To turn heater on press switch to POWER ON position. There
is a 5 second delay before the burner ignites. At this setting the
burner is on LOW and the fan speed is on LOW. Refer
figure 3.
The burner will ignite on both HIGH and LOW settings.
3
4. To turn burner to HIGH setting, press switch for HIGH setting.
Refer figure 4.
.
4
6
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.