Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
Oilless Compressors
Description
Oilless compressors are designed for do-it-yourselfers with a variety of home and automotive jobs. These units operate without oil. Compressed air from this unit will contain moisture. Install a water filter or air dryer if application requires dry air.
Unpacking
After unpacking the unit, inspect carefully for any damage that may have occurred during transit. Make sure to tighten fittings, bolts, etc., before putting unit into service. In case of questions, damaged or missing parts, please call 1-800-543-6400 for customer assistance.
Have the date code, model number, and parts list (with missing parts circled) before calling.
DO NOT RETURN
STOP!
Do not operate
during shipping, handling or use. Damage may result in bursting and cause injury or property damage.
THE PRODUCT TO THE RETAILER!
unit if damaged
READ & FOLLOW ALL
INSTRUCTIONS
SAVE THESE INSTRUCTIONS
DO NOT DISCARD
Record the Model No., Serial No. and date of purchase located on the base below the pump in the space below.
Model No. FP202801, FP202901
Serial No. ___________________
Date of purchase ____________
Retain these numbers for
future reference.
Safety Guidelines
This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols.
Danger indicates
an imminently hazardous situation which, if not avoided, WILL result in death or serious injury.
Warning indicates
a potentially hazardous situation which, if not avoided, COULD result in death or serious injury.
Caution indicates
a potentially hazardous situation which, if not avoided, MAY result in minor or moderate injury.
Breathable Air Warning
This compressor/pump is not equipped and should not be used “as is” to supply breathing quality air. For any application of air for human consumption, the air compressor / pump will need to be fitted with suitable in-line safety and alarm equipment. This additional equipment is necessary to properly filter and purify the air to meet minimal specifications for Grade D breathing as described in Compressed Gas Association Commodity Specification G
7.1 - 1966, OSHA 29 CFR 1910. 134, and/or Canadian Standards Associations (CSA).
DISCLAIMER OF WARRANTIES In the event the compressor is used for the purpose of breathing air application and proper in-line safety and alarm equipment is not simultaneously used, existing warranties shall be voided, and Campbell Hausfeld disclaims any liability whatsoever for any loss, personal injury or damage.
Notice indicates
important information, that if not followed, may cause damage to equipment.
NOTE: Information that requires special attention.
REMINDER: Keep your dated proof of purchase for warranty purposes!
Attach it to this manual or file it for safekeeping.
IN614207AV 1/10© 2010 Campbell Hausfeld/Scott Fetzer For parts, product & service information,
Operating Instructions and Parts List
General Safety Information
CALIFORNIA PROPOSITION 65
This product or its
power cord may contain chemicals, including lead, known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.
You can
create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry. This dust often contains chemicals known to cause cancer, birth defects, or other reproductive harm. Wear protective gear.
GENERAL SAFETY
Since the air compressor and other components (material pump, spray guns, filters, lubricators, hoses, etc.) used, make up a high pressure pumping system, the following safety precautions must be observed at all times:
1. Read all manuals
included with this product carefully. Be thoroughly familiar with the controls and the proper use of the equipment.
2. Follow all local electrical and safety
codes as well as in the United States, the National Electrical Codes (NEC) and Occupational Safety and Health Act (OSHA).
3. Only persons well acquainted
with these rules of safe operation should be allowed to use the compressor.
4. Keep visitors away and NEVER
allow children in the work area.
5. Wear safety glasses and
use hearing protection when operating the unit.
6. Do not stand on or use the unit as
a handhold.
7. Before each use, inspect
compressed air system and electrical components for signs of damage, deterioration, weakness or leakage. Repair or replace defective items before using.
8. Check all fasteners at frequent
intervals for proper tightness.
MANUAL
Motors,
electrical equipment and controls can cause electrical arcs that will ignite a flammable gas or vapor. Never operate or repair in or near a flammable gas or vapor. Never store flammable liquids or gases in the vicinity of the compressor.
Compressor parts may be hot even if the unit is stopped.
9. Keep fingers away from a
running compressor; fast moving and hot parts will cause injury and/ or burns.
10. If the equipment should start
to vibrate abnormally, STOP the engine/motor and check immediately for the cause. Vibration is generally a warning of trouble.
11. To reduce fire hazard, keep engine/
motor exterior free of oil, solvent, or excessive grease.
An ASME code
safety relief valve with a setting no higher than 125 psi MUST be installed in the tank for this compressor. The ASME safety valve must have sufficient flow and pressure ratings to protect the pressurized components from bursting.
See compressor
specification decal for maximum operating pressure. Do not operate with pressure switch or pilot valves set higher than the maximum operating pressure.
12. Never attempt to adjust ASME
safety valve. Keep safety valve free from paint and other accumulations.
Never use plastic
(PVC) pipe for compressed air. Serious injury or death could result.
Never
attempt to repair or modify a tank! Welding, drilling or any other modification will weaken the tank resulting in damage from rupture or explosion. Always replace worn, cracked or damaged tanks.
Drain liquid from
tank daily.
13. Tanks rust from moisture build-up,
which weakens the tank. Make sure to drain tank regularly and inspect periodically for unsafe conditions such as rust formation and corrosion.
FP202801, FP202901
14. Fast moving air will stir up dust and debris which may be harmful. Release air slowly when draining moisture or depressurizing the compressor system.
SPRAYING PRECAUTIONS
Do not
spray flammable materials in vicinity of open flame or near ignition sources including the compressor unit.
15. Do not smoke when spraying paint,
insecticides, or other flammable substances.
16. Use a face mask /
respirator when spraying and spray in a well ventilated area to prevent health and fire hazards.
17. Do not direct paint or other
sprayed material at the compressor. Locate compressor as far away from the spraying area as possible to minimize overspray accumulation on the compressor.
18. When spraying or cleaning with
solvents or toxic chemicals, follow the instructions provided by the chemical manufacturer.
Introduction
Refer to Figure 4 to locate the following items.
ON / OFF Switch ( I / O ) - Push switch to the ON ( I ) position to turn compressor on. Push switch to the OFF ( O ) position to turn compressor off. This switch should be in the OFF ( O ) position when connecting / disconnecting power cord from electrical outlet or when changing tools.
Figure 1
www.chpower.com
2
Operating Instructions and Parts List
Introduction (Continued)
Pressure Switch (located internally)- When the compressor
is turned ON, this switch will shut compressor off automatically when tank pressure reaches maximum shut­off / cut-out pressure. If compressor remains on and air is depleted from tank, this switch will allow compressor to automatically restart at the restart / cut-in pressure.
Regulator - The regulator controls the amount of air pressure released at the hose outlet. Turning the regulator knob clockwise (to the right) will increase air pressure at the outlet. Turning the knob counter-clockwise (to the left) will lower air pressure to the outlet. Turning knob fully counter­clockwise will shut off flow of air completely.
Pressure Gauges - There are two gauges located next to the regulator. These gauges read air pressure in pounds per square inch (psi) The larger gauge shows pressure at the outlet. Make sure this gauge reads ZERO (by adjusting the regulator) BEFORE changing air tools or disconnecting hose from outlet. The small gauge shows pressure in the tank indicating compressor is building pressure properly.
ASME Safety Valve - This valve automatically releases air if the tank pressure exceeds the preset maximum.
Handle - Designed to move the compressor.
Drain Valve - This valve is located on the bottom of the tank. Use this valve to drain moisture from the tank daily to reduce the risk of corrosion.
Figure 2
Motor Reset - (not shown, located
inside motor). Designed to keep the motor from overheating. The motor has an auto reset protector. To reset once the motor has cooled, turn the switch to the OFF position, then to the ON position.
This compressor is
equipped with an overload protector which will shut off motor if it becomes overloaded.
If the overload
protector is actuated, the motor must be allowed to cool down for approximately 30 minutes before it will reset.
FP202801, FP202901
Installation
LOCATION
It is extremely important to use the compressor in a clean, well ventilated area where the surrounding air temperature will not be more than 100°F.
A minimum clearance of 18 inches between the compressor and a wall is required because objects could obstruct air flow.
Do not locate the
compressor air inlet near steam, paint spray, sandblast areas or any other source of contamination. This debris will damage the motor.
GROUNDING INSTRUCTIONS
1. This product is for use on a
nominal 120 volt circuit and has a grounding plug that looks like the plug illustrated in Figure 3. Make sure the product is connected to an outlet having the same configuration as the plug. This product must be grounded. In the event of an electrical short circuit, grounding reduces risk of electrical shock by providing an escape wire for electric current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug. Plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.
Figure 4
Shroud
ON / OFF Switch
Tank
Tank Drain Valve
Handle
Regulator Gauge
Regulator
Tank Gauge
ASME Safety Valve
www.chpower.com
3
Operating Instructions and Parts List
FP202801, FP202901
Installation (Continued)
Grounded
Outlet
RESET
TEST
Grounding
Pin
Figure 3 - Grounding Method
Improper
use of grounding plug can result in a possible risk of electrical shock!
Do not use a
grounding adapter with this product!
2. If repair or replacement of cord or
plug is necessary, do not connect grounding wire to either flat blade terminal. The wire with insulation having an external surface that is green (with or without yellow stripes) is the grounding wire.
Never connect
green (or green and yellow) wire to a live terminal.
3. Check with a qualified electrician
or serviceman if grounding instructions are not completely understood, or if in doubt as to whether product is properly grounded. Do not modify plug provided; if it will not fit outlet, have proper outlet installed by a qualified electrician.
Overheating, short
circuiting and fire damage will result from inadequate wiring.
LUBRICATION This is an oilless product and DOES
NOT require lubrication to operate.
Pre-Operation
BEFORE FIRST START-UP BREAK-IN PROCEDURE
(Complete this procedure before using compressor for the first time. Once completed, it is not necessary to repeat.)
1. Turn regulator knob fully clockwise (to the right) to open air flow.
2. Do not attach a hose or any other fitting to the compressor.
3. Turn ON / OFF switch to OFF position.
4. Plug in power cord.
5. Turn ON / OFF switch to ON position and run compressor for 30 minutes.
6. Turn ON / OFF switch to OFF position.
7. Unplug power cord.
The compressor is now ready for use.
BEFORE EACH START-UP OPERATING PROCEDURE
1. Turn regulator knob fully counterclockwise (to the left) to close air flow.
2. Connect air hose to outlet of regulator.
3. Turn ON / OFF switch to OFF position.
4. Plug in power cord.
5. Turn ON / OFF switch to ON position and let compressor run until it reaches automatic shutoff pressure.
6. Attach tire chuck or tool to end of hose.
7. Turn regulator knob clockwise (to the right) to desired pressure of tool being used.
Operation
START-UP
Do not attach air
tools to open end of the hose until start-up is completed and the unit checks OK.
ON / OFF CYCLING OF COMPRESSOR
In the ON / AUTO position, the compressor pumps air into the tank. When a shut-off (preset “cut-out”) pressure is reached, the compressor automatically shuts off.
If the compressor is left in the ON / AUTO position and air is depleted from the tank by use of a tire chuck, tool, etc., the compressor will restart automatically at its preset “cut-in” pressure. When a tool is being used continuously, the compressor will cycle on and off automatically.
In the OFF position, the pressure switch cannot function and the compressor will not operate. Make sure switch is in OFF position when connecting or disconnecting power cord from electrical outlet.
PRESSURE GAUGES
Gauge attached to regulator indicates air pressure going to hose (and any tool attached to end of hose).
Gauge attached to pressure switch indicates air pressure in tank.
MOISTURE IN COMPRESSED AIR
Moisture in compressed air will form into droplets as it comes from an air compressor pump. When humidity is high or when a compressor is in continuous use for an extended period of time, this moisture will collect in the tank. When using a paint spray or sandblast gun, this water will be carried from the tank through the hose, and out of the gun as droplets mixed with the spray material.
IMPORTANT: This condensation will cause water spots in a paint job, especially when spraying other than water based paints. If sandblasting, it will cause the sand to cake and clog the gun, rendering it ineffective.
A filter in the air line, located as near to the gun as possible, will help eliminate this moisture.
www.chpower.com
4
Operating Instructions and Parts List
Maintenance
Disconnect, tag and lock out power source, then release all pressure from the system before attempting to install, service, relocate or perform any maintenance.
Check compressor often for any visible problems and follow maintenance procedures each time compressor is used.
Safety valve must
be replaced if it cannot be actuated or it leaks air after ring is released.
1. Turn compressor off and release
pressure from system. (To release pressure from system, pull ring on ASME safety valve. Deflect escaping air by shielding valve with one hand as you pull ring with other hand.) Pull ring until tank is empty.
A large amount of
fast moving air will be released when the safety valve is opened with pressure in the tank. Wear ANSI approved Z87.1 safety glasses.
2. Drain moisture from tank by
opening drain valve underneath tank. Tilt tank to remove all moisture.
3. Clean dust and dirt from tank,
air lines and pump cover while compressor is still OFF.
ASME SAFETY VALVE
Do not remove or
attempt to adjust the safety valve!
Check the safety valve by performing the following steps:
1. Plug the compressor in and run
until shut off pressure is reached.
2. Wearing safety glasses, pull the
ring on the safety valve to release pressure from compressor tank. Use your other hand to deflect fast-moving air from being directed toward your face.
3. The safety valve should automatically close at approximately 40 psi - 50 psi. If the safety valve does not allow air to be released when you pull on the ring, or if it does not close automatically, it MUST be replaced.
DRAIN TANK
With compressor shut off and pressure released, drain moisture from tank by opening drain valve underneath tank.
CLEANING
Turn power OFF and clean dust and dirt from pump cover, tank, and air lines.
IMPORTANT: Unit should be located as far from spraying area as hose will allow to prevent over-spray from clogging air filter.
LUBRICATION.
This is an oilless type compressor requiring no lubrication.
OVERLOAD PROTECTOR
This compressor
is equipped with a manual reset overload protector which will shut off motor if it becomes overloaded.
If overload protector shuts motor OFF frequently, look for the following causes.
1. Low voltage.
2. Clogged air filter.
3. Lack of proper ventilation.
If the overload
protector is actuated, the motor must be allowed to cool down for 30 minutes before manual resetting.
FP202801, FP202901
END OF OPERATION/STORAGE
1. Turn ON / OFF switch to the OFF position.
2. Unplug power cord from wall outlet and wrap around handle area to prevent damage when not in use.
3. Wearing safety glasses drain tank of air by pulling the ring on the safety valve. Use other hand to deflect fast moving air from being directed toward your face.
4. Drain tank of condensation by opening drain valve on bottom of tank. Tank pressure should be below 10 psi when draining tank.
5. Air hose should be disconnected from compressor and hung open ends down to allow any moisture to drain.
6. Compressor and hose should be stored in a cool, dry place.
TECHNICAL SERVICE
For information regarding the operation or repair of this product, please call 1-800-543-6400.
Figure 5
MAINTENANCE SCHEDULE
OPERATION DAILY WEEKLY MONTHLY
DRAIN TANK CHECK SAFETY VALVE CLEAN UNIT
5
l
l
l
www.chpower.com
Operating Instructions and Parts List
FP202801, FP202901
Troubleshooting Chart
Symptom Possible Cause(s) Corrective Action
Compressor will not run 1. Switch in OFF position 1. Make sure compressor is plugged in and switch is ON.
2. No electrical power at wall outlet 2. Check circuit breaker or fuse at electrical panel.
3. Compressor has reached automatic shutoff pressure
4. Motor overheated 4. Allow compressor to cool for approximately 30 minutes so
5. Pressure switch bad 5. Replace pressure switch.
Thermal overload protector cuts out repeatedly
Tank pressure drops when compressor shuts off
Compressor runs continuously and air output is lower than normal/low discharge pressure
Excessive moisture in discharge air
Safety valve pops open 1. Defective pressure switch 1. Replace pressure switch.
1. Low voltage 1. Check voltage at wall outlet with voltmeter.
2. Wrong gauge wire or length of extension cord
3. Clogged intake filter 3. Clean or replace filter.
4. Lack of proper ventilation/room temperature too high
5. Defective check valve 5. Repair or replace.
6. Defective unloader valve (on pressure switch)
7. Compressor valves failed 7. Replace valve assembly.
1. Loose drain valve 1. Tighten.
2. Check valve leaking 2. Remove check valve. Clean or replace.
3. Loose connections at fittings, tubing, etc.
4. Tank leaks 4. Check tank for leaks with soap and water solution. If leak is
1. Excessive air usage, compressor too small
2. Clogged intake filter 2. Clean or replace.
3. Loose connections at fittings, tubing, etc.
4. Tank leaks 4. Check tank for leaks with soap and water solution. If leak is
5. Broken valves 5. Replace compressor valves as necessary.
6. Piston ring worn 6. Replace piston rings.
1. Excessive water in tank 1. Drain tank.
2. High humidity 2. Move to area of less humidity; use air line filter.
2. Defective safety valve 2. Replace safety valve with genuine replacement part.
3. Release air from tank until compressor restarts automatically.
thermal overload switch will reset. Make sure compressor is run in a clean, well-ventilated area.
2. Check extension cord chart for proper extension cord usage.
4. Move compressor to well-ventilated area.
6. Repair or replace.
Do not disassemble check valve with
air pressure in tank; bleed tank.
3. Check all connections with soap and water solution. If a leak is detected, (1) tighten or (2) remove fitting and apply pipe tape to threads and reassemble.
detected, tank must be replaced with genuine replacement part.
Do not disassemble check valve with
air pressure in tank; bleed tank.
1. Decrease usage or purchase unit with higher air delivery (SCFM).
3. Check all connections with soap and water solution. If a leak is detected, (1) tighten or (2) remove fitting and apply pipe tape to threads and reassemble.
detected, tank must be replaced with genuine replacement part.
NOTE: Water condensation is not caused by compressor
malfunction.
www.chpower.com
6
Operating Instructions and Parts List
FP202801, FP202901
For replacement parts or technical assistance, call 1-800-543-6400
Please provide following information:
- Model number
- Serial number (if any)
- Part description and number as shown in parts list
3
1
Address any correspondence to:
Campbell Hausfeld Attn: Customer Service 100 Production Drive Harrison, OH 45030
12
28
27
5
2
4
20
25
19
33
17
21
23 32
11
16
18
27
6
26
7
14
30
10
29
22
8
24
9
15
31
13
Ref. Part No. Description Number Qty.
1 Shroud s 1 2 Shroud insert s 1 3 ON/OFF switch FP204824AV 1 4 M3x15 screw s 6 5 Regulator Gauge FP204013AV 1 6 Tank Gauge FP204012AV 1 7 Safety valve V-215104AV 1 8 Plastic base n 1 9 Pressure switch FP209538AV 1 10 Check valve (includes part #29 & #30) FP209532AV 1 11 M4 x 0.7 x 6 screw * 1 12 M6 x 1.0 x 10 screw l 4 13 Drain valve D-1403 1 14 Rubber foot (tank) u 3 15 Wire (pressure switch to power switch) FP209523AV 1 16 Power cord t 1 17 M3 x 10 screw * 1 18 Pump/motor assembly (includes part #21) FP209039AV 1 19 Motor cover n 1 20 Wire clip FP202823AV 1
Ref. Part No. Description Number Qty.
21 Exhaust tube kit FP202839AV 1 22 Motor isolator bushing kit FP209037AV 1 23 Accessories FP204008AV 1 24 Nut l 4 25 Screw l 4 26 Screw l 4 27 Regulator assembly FP204835AV 1 28 Screw l 2 29 Spring (see part #10) 1 30 Cap (see part #10) 1 31 Tank -- 1 32 25-foot Recoil Hose MP268100AV 1 33 Strain relief t 1
REPAIR KITS AND ACCESSORIES
s Shroud kit FP209034AV n Motor cover and base kit FP209038AV l Fastener kit FP209040AV u Rubber foot kit FP202836AV t Power cord / strain relief kit FP209534AV I Decal kit FP202837AV
* Standard hardware item
-- Not available
www.chpower.com
7
Operating Instructions and Parts List
FP202801, FP202901
Limited Warranty
1. DURATION: From the date of purchase by the original purchaser as follows: One Year.
2. WHO GIVES THIS WARRANTY (WARRANTOR): Campbell Hausfeld / Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Telephone: (800) 543-6400
3. WHO RECEIVES THIS WARRANTY (PURCHASER): The original purchaser (other than for purposes of resale) of the Campbell Hausfeld compressor.
4. WHAT PRODUCTS ARE COVERED BY THIS WARRANTY: This Campbell Hausfeld air compressor.
5. WHAT IS COVERED UNDER THIS WARRANTY: Substantial defects due to material and workmanship with the exceptions noted below.
6. WHAT IS NOT COVERED UNDER THIS WARRANTY: A. Implied warranties, including those of merchantability and FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED
FROM THE DATE OF ORIGINAL PURCHASE AS STATED IN THE DURATION. If this compressor is used for commercial, industrial or rental purposes, the warranty will apply for ninety (90) days from the date of purchase. Some States do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.
B. ANY INCIDENTAL, INDIRECT, OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM ANY
DEFECT, FAILURE, OR MALFUNCTION OF THE CAMPBELL HAUSFELD PRODUCT. Some States do not allow the exclusion or limitations of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
C. Any failure that results from an accident, purchaser’s abuse, neglect or failure to operate products in accordance
with instructions provided in the owner’s manual(s) supplied with compressor. D. Pre-delivery service, e.g. assembly, oil or lubricants, and adjustment. E. Items or service that are normally required to maintain the product, e.g. lubricants, filters and gaskets, etc. F. Additional items not covered under this warranty:
1. Any component damaged in shipment or any failure caused by installing or operating unit under conditions not in accordance with installation and operation guidelines or damaged by contact with tools or surroundings.
2. Pump or valve failure caused by rain, excessive humidity, corrosive environments or other contaminants.
3. Cosmetic defects that do not interfere with compressor functionality.
4. Rusted tanks, including but not limited to rust due to improper drainage or corrosive environments.
5. Drain cocks.
6. Damage due to incorrect voltage or improper wiring.
7. Other items not listed but considered general wear parts.
8. Pressure switches, air governors and safety valves modified from factory settings.
9. Belts.
10. Ring wear or valve damage from inadequate filter maintenance.
7. RESPONSIBILITIES OF WARRANTOR UNDER THIS WARRANTY: Replace, at Warrantor’s option, compressor or component which is defective, has malfunctioned and/or failed to conform within the duration of the specific warranty period.
8. RESPONSIBILITIES OF PURCHASER UNDER THIS WARRANTY: A. Provide dated proof of purchase and maintenance records. B. Call Campbell Hausfeld (800-543-6400) to obtain your warranty service options. Freight costs must be borne by the
purchaser.
C. Use reasonable care in the operation and maintenance of the products as described in the owner’s manual(s).
9. WHEN WARRANTOR WILL PROVIDE REPLACEMENT UNDER THIS WARRANTY: Replacement will be scheduled according to the availability of replacement compressor or parts.
This Limited Warranty applies in the U.S., Canada and Mexico only and gives you specific legal rights. You may also have other rights which vary from State to State or country to country.
www.chpower.com
8
Loading...
+ 16 hidden pages