CAME STYLO-ME User Manual

h
STYLO SERIES
EXTERNAL AUTOMATION FOR SWING GATES
INSTALLATION MANUAL
STYLO-ME
Englis
EN
2
119DV 11
1.0
Index
Legend of symbols
P. 4
Intended use and restrictions P. 4
Intended use P. 4 Restrictions P. 4
Description P. 4
Technical features P. 4 Dimensions P. 5 Description of parts P. 5
ENGLISH
Installation P. 6
Preliminary checks P. 6 Examples P. 6 Tools and materials P. 8 Cable list and minimum thickness P. 8 Standard installation P. 8 Installing the operator P. 9 Manually releasing the gearmotor P. 14
Electrical connections P. 15
Electric connections to the ZL92 control panel P. 15
Safety instructions P. 16 Maintenance P. 17
Periodic maintenance P. 17 Trouble shooting P. 17 Extra-ordinary maintenance P. 18
Phasing out and disposal P. 19 Conformity declaration P. 19
1.0 03/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
119DV11 ver.
2 - Manual code:
Pag.
3
119DV 11
1.0
WARNING!
Important instructions for the safety of people:
READ CAREFULLY!
Foreword
• Use of the products must be restricted to its intended use (i.e. that for which it was expressly built for). Any other use is to be considered dangerous. Came Cancelli Automatici S.p.A. is not liable for any damage resulting from improper, wrongful or unreasonable use • Keep these warnings with the installa­tion and use manuals issued with the automated system.
Before installing
(preliminary check: in case of a negative
outcome, do not proceed before having
complied with the safety obligations)
• Make sure that the parts you intend to automate are in good working order, and that they are properly balanced and aligned. Also, make sure that proper mechanical stops are already in place • If the operator will be installed at a height of less than 2.5 m from the ground or other access level, check whether you will need any protections and/or warnings • Any gate leaves, fi tted with pedestrian entrances, onto which you will install an operator, must have a blocking mechanism when the gate is in motion • Make sure that the opening of the automated gate is not an entrapment hazard as regards any surrounding fi xed parts • Do not mount the operator upside down or onto any elements that may fold under its weight. If needed, add suitable reinforcements at the points where it is secured • Do not install onto gates on either an upward or downward slope (i.e. that are not on fl at, level ground) • Check that any lawn watering devices will not wet the gearmotor from the bottom up.
are working properly • Where necessary and in plain sight, apply the Warning Sings (e.g. gate plate).
Special instructions and
advice for users
• Keep the gate’s area of operation clean and clear of any obstacles. Trim any vegetation that may interfere with the photocells • Do not allow children to play with the fi xed com­mand devices, or in the gate’s area of operation. Keep any remote control devices (i.e. transmitters) away from the chil­dren as well • Frequently check the system, to see whether any anomalies or signs of wear and tear appear on the moving parts, on the component parts, on the securing points, on the cables and any accessible connections. Keep any joints (i.e. hinges) lubricated and clean, and do the same where fric­tion may occur (i.e. slide rails) • Perform functional tests on photocells and sensitive edges, every six months. Keep glass panels constantly clean (use a slightly water-moistened cloth; do not use solvents or any other chemical products) • If the system requires repairs or modifi cations, release the operator and do not use it until safety conditions have been restored
• Cut off the power supply before releasing the operator for manual openings. See instructions • Users are FORBIDDEN to carry out ANY ACTIONS THAT THEY HAVE NOT BEEN EXPRESSLY ASKED TO DO OR SO INDICATED in the manu­als. Any repairs, modifi cations to the settings and extraor­dinary maintenance MUST BE DONE BY THE TECHNICAL ASSISTANCE STAFF • On the periodic maintenance log, note down the checks you have done.
ENGLISH
Installation
• Carefully section off the entire site to prevent unauthorised access, especially by minors and children • Be careful when handling operators that weigh more than 20 Kg (see installa-
The data and information repor ted in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
tion manual). In such cases, employ proper weight handling safety equipment • All opening commands (e.g. buttons, key selectors, magnetic detectors, etc.) must be installed at least
1.85 m from the gate’s area of operation perimeter - or where they cannot be reached from the outside of the gate. Also, the direct commands (e.g. push button, or proximity devices, etc.) must be installed at a height of at least 1.5 m and must
© CAME cancelli automatici s.p.a. -
not be accessible to the public • All ‘maintained action’ com­mands, must be placed where the moving gate leaves, transit
1.0 03/2 010
areas and driveways are completely visible • If missing, ap­ply a permanent label that shows the position of the release mechanism • Before delivering to the client, verify that the
119DV11 ver.
:
system is EN 12453 (impact test) standard compliant. Make sure that the operator has been properly adjusted and that the safety and protection devices, as well as the manual release
Manual code
3 -
Pag.
Special instructions and
advice for all
• Avoid working near the hinges or moving mechanical parts
• Stay clear of the gate’s area of operation when in motion • Do not resist the direction of movement of the gate; this may present a safety hazard • At all times be extremely careful about dangerous points that must be indicated by proper pictograms and/or black and yellow stripes • When using a selector or command in ‘maintained action’ mode, keep checking that there are no people in the area of operation of the moving parts. Do this until you release the command • The gate may move at any time without warning • Always cut the power when cleaning performing maintenance.
4
119DV 11
1.0
Legend of symbols
This symbol tells you to read the section with particular care.
This symbol tells you that the sections concern safety issues.
This symbol tells you what to say to the end-users.
Intended use and restrictions
ENGLISH
Intended use
The STYLO-ME gearmotor is designed to automate residential and apartment block swing-gates in even intensive use conditions.
Restrictions
Gate-leaf width (m) 0,8 1,2 1,8 Gate-leaf weight (kg) 150 125 100
Description
This product is designed and built by CAME CANCELLI AUTOMATICI S.p.A. in compliance with current safety norms. Guaranteed 24 months unless tampered with.
Technical features
STYLO-ME
Control board power supply: 230 AC 50/60Hz Motor power supply: 24V DC 50/60Hz Max draw.: 5A Power: 48W Maximum torque: 100Nm Opening time (90°): adjustable Gear ratio: 1/531 Duty Cycle: Intensive use Protection Rating: IP54 Weight: kg Working temperature:
#
#
1.0 03/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
119DV11 ver.
4 - Manual code:
Pag.
5
119DV 11
1.0
Dimensions
STYLO-ME
(mm)
80
106
437,5
Description of parts
1) Main body of the gearmotor
2) Upper cap
3) Lower cap
4) Hinged arm
5) STYLO-BS arm securing bracket
6) Gearmotor securing bracket
7) STYLO-BS cover
8) STYLO-BD cover
9) Slide guide
10) Opening stop
11) STYLO-BD slide rail
12) Closing stop
STYLO-BD
650
57
ENGLISH
STYLO-BS
330
90°
330
STYLO-BS
7
4
5
11
STYLO-ME
The data and information repor ted in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
2
STYLO-BD
10
6
© CAME cancelli automatici s.p.a. -
9
4
12
1.0 03/2 010
1
8
119DV11 ver.
:
Manual code
5 -
Pag.
3
6
119DV 11
1.0
Installation
Installation must be carried out by expert qualified personnel and in full compliance with current regulations.
Preliminary checks
Before installing, do the following:
• Make sure you have suitable tubing and conduits for the electrical cables to pass through and be protected against mechanical damage;
• Fit tubing to drain away any water leaks which may cause oxidation;
ENGLISH
Make sure that any connections within the container (made for uninterruptable power supply to the protection circuit) are fitted
with additional insulation compared to the other internal parts;
• Make sure the gate structure is sturdy enough, that the hinges are in proper working order and that there is no fiction among the moving and fixed parts;
• Make sure there are opening and closing mechanical stops..
Examples
STYLO-BS
180
40
80
450
i
i = 300 mm max
with 90° opening
450
450
180
120
450
120~max
1.0 03/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
119DV11 ver.
6 - Manual code:
Pag.
Loading...
+ 14 hidden pages