STYLO SERIES
EXTERNAL AUTOMATION FOR SWING GATES
INSTALLATION MANUAL
STYLO-ME
Englis
EN
Index
Legend of symbols
P. 4
Intended use and restrictions P. 4
Intended use P. 4
Restrictions P. 4
Description P. 4
Technical features P. 4
Dimensions P. 5
Description of parts P. 5
ENGLISH
Installation P. 6
Preliminary checks P. 6
Examples P. 6
Tools and materials P. 8
Cable list and minimum thickness P. 8
Standard installation P. 8
Installing the operator P. 9
Manually releasing the gearmotor P. 14
Electrical connections P. 15
Electric connections to the ZL92 control panel P. 15
Safety instructions P. 16
Maintenance P. 17
Periodic maintenance P. 17
Trouble shooting P. 17
Extra-ordinary maintenance P. 18
Phasing out and disposal P. 19
Conformity declaration P. 19
1.0 03/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
119DV11 ver.
2 - Manual code:
Pag.
WARNING!
Important instructions for the safety of people:
READ CAREFULLY!
Foreword
• Use of the products must be restricted to its intended use
(i.e. that for which it was expressly built for). Any other use is
to be considered dangerous. Came Cancelli Automatici S.p.A.
is not liable for any damage resulting from improper, wrongful
or unreasonable use • Keep these warnings with the installation and use manuals issued with the automated system.
Before installing
(preliminary check: in case of a negative
outcome, do not proceed before having
complied with the safety obligations)
• Make sure that the parts you intend to automate are in
good working order, and that they are properly balanced
and aligned. Also, make sure that proper mechanical stops
are already in place • If the operator will be installed at a
height of less than 2.5 m from the ground or other access
level, check whether you will need any protections and/or
warnings • Any gate leaves, fi tted with pedestrian entrances,
onto which you will install an operator, must have a blocking
mechanism when the gate is in motion • Make sure that the
opening of the automated gate is not an entrapment hazard
as regards any surrounding fi xed parts • Do not mount the
operator upside down or onto any elements that may fold
under its weight. If needed, add suitable reinforcements at
the points where it is secured • Do not install onto gates on
either an upward or downward slope (i.e. that are not on fl at,
level ground) • Check that any lawn watering devices will not
wet the gearmotor from the bottom up.
are working properly • Where necessary and in plain sight,
apply the Warning Sings (e.g. gate plate).
Special instructions and
advice for users
• Keep the gate’s area of operation clean and clear of any
obstacles. Trim any vegetation that may interfere with the
photocells • Do not allow children to play with the fi xed command devices, or in the gate’s area of operation. Keep any
remote control devices (i.e. transmitters) away from the children as well • Frequently check the system, to see whether
any anomalies or signs of wear and tear appear on the moving
parts, on the component parts, on the securing points, on the
cables and any accessible connections. Keep any joints (i.e.
hinges) lubricated and clean, and do the same where friction may occur (i.e. slide rails) • Perform functional tests on
photocells and sensitive edges, every six months. Keep glass
panels constantly clean (use a slightly water-moistened cloth;
do not use solvents or any other chemical products) • If the
system requires repairs or modifi cations, release the operator
and do not use it until safety conditions have been restored
• Cut off the power supply before releasing the operator for
manual openings. See instructions • Users are FORBIDDEN
to carry out ANY ACTIONS THAT THEY HAVE NOT BEEN
EXPRESSLY ASKED TO DO OR SO INDICATED in the manuals. Any repairs, modifi cations to the settings and extraordinary maintenance MUST BE DONE BY THE TECHNICAL
ASSISTANCE STAFF • On the periodic maintenance log, note
down the checks you have done.
ENGLISH
Installation
• Carefully section off the entire site to prevent unauthorised
access, especially by minors and children • Be careful when
handling operators that weigh more than 20 Kg (see installa-
The data and information repor ted in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
tion manual). In such cases, employ proper weight handling
safety equipment • All opening commands (e.g. buttons, key
selectors, magnetic detectors, etc.) must be installed at least
1.85 m from the gate’s area of operation perimeter - or where
they cannot be reached from the outside of the gate. Also,
the direct commands (e.g. push button, or proximity devices,
etc.) must be installed at a height of at least 1.5 m and must
© CAME cancelli automatici s.p.a. -
not be accessible to the public • All ‘maintained action’ commands, must be placed where the moving gate leaves, transit
1.0 03/2 010
areas and driveways are completely visible • If missing, apply a permanent label that shows the position of the release
mechanism • Before delivering to the client, verify that the
119DV11 ver.
:
system is EN 12453 (impact test) standard compliant. Make
sure that the operator has been properly adjusted and that the
safety and protection devices, as well as the manual release
Manual code
3 -
Pag.
Special instructions and
advice for all
• Avoid working near the hinges or moving mechanical parts
• Stay clear of the gate’s area of operation when in motion •
Do not resist the direction of movement of the gate; this may
present a safety hazard • At all times be extremely careful
about dangerous points that must be indicated by proper
pictograms and/or black and yellow stripes • When using
a selector or command in ‘maintained action’ mode, keep
checking that there are no people in the area of operation of
the moving parts. Do this until you release the command •
The gate may move at any time without warning • Always cut
the power when cleaning performing maintenance.
Legend of symbols
This symbol tells you to read the section with particular care.
This symbol tells you that the sections concern safety issues.
This symbol tells you what to say to the end-users.
Intended use and restrictions
ENGLISH
Intended use
The STYLO-ME gearmotor is designed to automate residential and apartment block swing-gates in even intensive use conditions.
Restrictions
Gate-leaf width (m) 0,8 1,2 1,8
Gate-leaf weight (kg) 150 125 100
Description
This product is designed and built by CAME CANCELLI AUTOMATICI S.p.A. in compliance with current safety norms.
Guaranteed 24 months unless tampered with.
Technical features
STYLO-ME
Control board power supply: 230 AC 50/60Hz
Motor power supply: 24V DC 50/60Hz
Max draw.: 5A
Power: 48W
Maximum torque: 100Nm
Opening time (90°): adjustable
Gear ratio: 1/531
Duty Cycle: Intensive use
Protection Rating: IP54
Weight: kg
Working temperature:
#
#
1.0 03/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
119DV11 ver.
4 - Manual code:
Pag.
Dimensions
STYLO-ME
(mm)
80
106
437,5
Description of parts
1) Main body of the gearmotor
2) Upper cap
3) Lower cap
4) Hinged arm
5) STYLO-BS arm securing bracket
6) Gearmotor securing bracket
7) STYLO-BS cover
8) STYLO-BD cover
9) Slide guide
10) Opening stop
11) STYLO-BD slide rail
12) Closing stop
STYLO-BD
650
57
ENGLISH
STYLO-BS
330
90°
330
STYLO-BS
7
4
5
11
STYLO-ME
The data and information repor ted in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
2
STYLO-BD
10
6
© CAME cancelli automatici s.p.a. -
9
4
12
1.0 03/2 010
1
8
119DV11 ver.
:
Manual code
5 -
Pag.
3
Installation
Installation must be carried out by expert qualified personnel and in full compliance with current regulations.
Preliminary checks
Before installing, do the following:
• Make sure you have suitable tubing and conduits for the electrical cables to pass through and be protected against mechanical
damage;
• Fit tubing to drain away any water leaks which may cause oxidation;
ENGLISH
•
Make sure that any connections within the container (made for uninterruptable power supply to the protection circuit) are fitted
with additional insulation compared to the other internal parts;
• Make sure the gate structure is sturdy enough, that the hinges are in proper working order and that there is no fiction among the
moving and fixed parts;
• Make sure there are opening and closing mechanical stops..
Examples
STYLO-BS
180
40
80
450
i
i = 300 mm max
with 90° opening
450
450
180
120
450
120~max
1.0 03/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
119DV11 ver.
6 - Manual code:
Pag.