These devices and their accessories may only be operated in compliance with the operating instructions (intended use)!
These devices and their accessories may only be commissioned by trained and qualified personnel.
These devices may only be operated with the intended operating voltages and parameters.
If malfunctions occur that cannot be rectified, shut down the device and send it in for repair.
These devices are only allowed to be repaired by the manufacturer. Tampering and alterations are not permitted. This will invalidate all guarantee and
warranty claims.
Mechanical mounting in the switch cabinet
2
The SMA / SMA 2 / SMA 220 is mounted on a 35 mm mounting rail acc. to EN 50 022 in the switch cabinet.
The terminals are pluggable and coded.
Electrical connection
3
The loop connection wiring to the loop detector must be twisted at least 20 times per meter.
Please ensure the unit is wired properly with correct input voltage and all terminals are connected according to the wiring diagram on the label.
SMA/SMA 2/ SMA 220 loop detector DIN variant, mounting rail installation
LCD display
«Mode» button
«Data»-button
Terminals
Info LED
ENGLISH
Terminal connection diagram
3.1
A:
Supply
voltage
connection
B:
Loop connection
1-channel device
C:
Loop connection
2-channel device
D:
Alarm output
connection
(optional)
E:
Relay connection
output 1
F:
Relay connection
output 2
Output connection options (depending on the options ordered):
Relay assignment:
1-loop device
Output 1E
Output 2F
Alarm outputD
Value and parameter setting options
4
Output connection
diagram:
2-loop device
Relay assignment:
Output 1+2E, F
Alarm outputD
Output connection
diagram:
General
The settings of the devices in this chapter are shown and explained for the 1-loop device. The settings for loop 2 of a 2-loop device should be made using
the corresponding method.
LCD display and controls
4.1
Standard display
1-loop device
Standard display
2-loop device
Control buttonControl button
Explanation of the LCD displayExplanation of the LED
Function
Example:
Time
function set
Loop 1
Loop 2
Example:
Parameter «h»
set
Red + green: Start-up phase
Green:Operation
Red + green: Configuration
Flashing green: Output 1 and/or
Flashing red: Error
Flashing
red + green: Simulation
2 activated
1
Page 2
Loop
Relay
Loop
Relay
t
t
Loop
Relay
tt
Loop
Relay
tt
Loop
Relay
tt
Loop
Relay
tt
4.2
1
Mode
Sim1
1
1
2
Mode
Sim1
1
Mode
Sim1
2
common
nc
no
common
nc
no
common
nc
no
common
nc
no
Basic functions 0 (see Table 4.11a for settings)
Parameters
1: Door and gate The assigned output relay picks up when the loop is activated and drops out when the loop returns to a non-activated condition.
2: BarrierThe assigned output relay picks up when the loop is activated and drops out when the loop returns to a non-activated condition.
: Quiescent current The assigned output relay drops out when the loop is activated and picks up again when the loop returns to a non-activated condition.
3
4: Direction logic Output 1 switches if an object moves from loop 1 to 2. Output 2 switches if an object moves from loop 2 to 1. Both loops must be
activated for a short time. The outputs are reset again when loop 2 returns to a non-activated condition. Both loops must have returned to a non-activated condition for another direction detection.
0: Loop 2 Loop 2 can be deactivated in a 2-loop device.
Relay response to malfunctions (see chapter 6 Troubleshooting):
1.Door/gate
systems
4.3
Time functions 1 , time unit 2 and time factor 3 (Einstellungen siehe Tabelle 4.11a)
A malfunction causes
the output relay to be
released. The alarm
relay drops out.
2. Barrier
The relay picks up when the
loop is activated and drops
out when the loop is exited.
Activation pulse:
The relay picks up when the
loop is activated and drops
out again after the time t.
Sensitivity 4 (see Table 4.11a for settings)
4.4
A malfunction causes
the output relay to pick
up. The alarm relay
drops out.
On delay:
The relay picks up after the
time t when the loop is activated and drops out when
the loop is exited.
Impulse by leaving the loop:
By leaving the loop,
the relay picks up after
the time t, relay drops out.
3. Quiescent
current
A malfunction causes
the output relay to be
released. The alarm
relay drops out.
Off delay:
The relay picks up when the
loop is activated and drops
out after the time t when the
loop is exited.
Max. presence:
he relay picks up when the
loop is activated and drops
out again after leaving, but
at least after the time t.
4. Direction logic
(2-loop device
only)
A malfunction causes
the output relays to be
released. The alarm
relay drops out.
The sensitivity 5 (=Sensitivity) of the loop detector can be adapted in 9 stages: 51 = Lowest sensitivity, 59 = Highest sensitivity,
54 = Factory setting.
4.5
Automatic Sensitivity Boost ASB 5 (see Table 4.11a for settings)
ASB (=Automatic Sensitivity Boost). ASB is required in order to be able to recognise trailer drawbars after activation.
4.6
Frequency 6 (see Table 4.11a for settings)
Four different frequencies F1, F2, F3, F4* can be set in order to avoid interference when using several loop detectors.
4.7
Direction logic7 (see Table 4.11a for settings)
The direction logic function can only be used with a 2-loop device. Direction logic must have been set in the basic function (see chapter 4.2). Detection
can be performed from: ➝ Loop 1 to loop 2 ➝ From loop 2 to loop 1 ➝ from both directions
4.8
Output 2 8 (see Table 4.11b for settings)
In a device with 2 outputs, output 2 can be either activated or deactivated.
4.9
Protection against power failure 9 (see Table 4.11a for settings)
Note: The set parameter values are retained after a power failure, independent from the “Protection against power failure” function.
P 1 = Protection against power failure activated: The sensitivity is restricted to 1–5.
4 .9.1
Signal characteristics with protection against power failure active (Function 9 = 1)
For Activation (e.g. Barriers)
Basic function 0 = 2 Barrier systems
Output
Without powerInitialisationFreeOccupiedFree
For Safeguarding (e.g. Barriers, bollards)
Basic function 0 = 3 Quiescent current
Output
Without powerInitialisationFreeOccupiedFree
2
4.10
1- loop device
Display after start-up:
2- loop device
Display after start-up:
Changeover from operation to configuration mode
Touch the «Mode» button once
to change to configuration
mode
Touch the «Mode» button once
to change to configuration
mode
Loop 1 is
selected
Loop 2 is
selected
*factory settings
Page 3
1
Mode
Sim1
1
Mode
Sim1
1
Mode
Sim1
1
Mode
Sim1
1
Mode
Sim1
1
Mode
Sim1
1
Mode
Sim1
1
2
Mode
Sim1
1
Mode
Sim1
Mode
Sim1
1
Data
Sim2
Data
Sim2
Data
Sim2
Data
Sim2
Data
Sim2
Data
Sim2
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
2
1
2
2
2
1
ng
Loop
Relay
tt
Loop
Relay
Loop
Relay
tt
Loop
Relay
tt
Loop
Relay
tt
Loop
Relay
tt
etti
s
Notes
With deactivation of Loop 2
the output 2 becomes
configurable g 8
The time unit multiplied by
the time factor gives the
set time.
Setting restrictions:
rotection against power
failure (with P1): Value 1-5
The direction logic function
can only be implemented
with 2 loops and a 2-loop
device
Loop 2 has to be
deactivated «0»
(5= A0 ).
If parameter 9 = P 1
parameter 5 must be set to off
Possible displays in case of
tory
ac
F
*
error: see chapter 6 of these
operating instructions
Max. presence
deactivated: «0»
activated: «1»*
Loop 2
Only 2-loop device:
Time funct. pulse
when loop is exited
Activation
pulse loop
Direction logic
Off delay
Quiescent current
1 hour
1 minute
Frequency F3
Frequency F2
Loop 1 to loop 2
Error memory
slot 5
slot 3
Error memory
slot 3
Error memory
Error memory slot 2
On delay
Barrier systems
∞*
Door/gate
systems*
Button operation
parameter
1 second*
0.1 second
This display does
not appear with
time function th (∞)
button
holding the «Data»
and 99 by touching or
Set value between 1
1*
This display does
not appear wih time
function th (∞)
the «Data» button
by touching or holding
) and 9 (highest sensi.)
Set value betw. 1 (lowest
4*
5 = Sensitivity
Switched on
Switched off*
ASB stands for
Automatic Sensiti-
Frequency F1
Frequency F4*
vity Boost
Loop 2 to loop
Both directi-
This display appears
Output 2 is
1
ons*
only with a
activated
Output 2 is
switched off
2-loop device
Error memory
Switched on
Switched off*
slot 1
Operating
mode
Notes
1 = Output 2 on; 0 = Output 2 off
Parameter 8 is not possible and is not displayed
1 = Output 2 on; 0 = Output 2 off
Output 2
–
1*/0
1/0*
functions
Button operation
–
active
LCD
display
deactivated
Configuration mode
4.11
Note on 2-loop device: After loop 1 has been set, the parameters for loop 2 are set (make the settings using the same procedure) and the settings are not shown in the table with the exception of the direction logic
Table 4.1a Settings
Function
0 - Basic function
1 - Time function
2 - Time unit
3 - Time factor
4 - Sensitivity
Sensitivity Boost
ASB
5 - Automatic
6 - Frequency
7 - Direction logic
configuration
against power
9 - Protection
8 - Output 2
mode
failure
A - Operating
Table 4.11b Different product variants (setting options)
1-loop device, 2 relays
SMA/SMA 2/ SMA 220
2-loop device, 2 relays
3
Page 4
Mode
Sim1
2 seconds
Data
Sim2
2
seconds
1
1
Data
Sim2
1
Mode
S
im1
2
Data
Sim2
2
Mode
S
im1
1
Data
S
im2
1
Mode
Sim1
2
Data
S
im2
2
Mode
Sim1
Data
Sim2
M
ode
Sim1
1
Mode
Sim1
2
Mode
Sim1
2 seconds
1
2
Simulation mode
Mode
Sim1
2 seconds
M
ode
Sim1
8 seconds
Data
S
im2
5
Changeover to simulations mode
Press «Sim1»
button
Press «Sim2»
button
Press «Sim2»
button
Press «Sim2»
button
Notes
Changeover to simulation mode:
Press the Sim1 + Sim2 buttons
simultaneously for 2 seconds.
+
Simulation mode:
Activation of the loop
Activation of the output relay
Alarm output activation
Inductance of loop 1
Inductance of loop 2
Exiting simulation mode
Troubleshooting
6
L0 -No loop activation (time functions are active)
L1 -Loop activation (time functions are active)
- Loop 1 - Loop 2
00 - Activation of output
01 - Activation of output
- Loop 1 - Loop 2
A0 -Switch off alarm relay
A1 -Switch on alarm relay
Measurement of the inductance, value in µH
Measurement of the inductance, value in µ
Return to function mode
If an error occurs, operating mode «A» and error display «E» light up alternately and an error code such as E 012 is displayed. The LED changes to
flashing red, the 4 most recent errors are stored and can be interrogated.
Briefly pressing the «Data» button shows the last of 4 errors on the display. Another short press switches to the error before that, and so on. When
the button is pressed for the 5th time, the device switches back to automatic mode. If you press the «Data» button for 4 seconds during the query,
all error messages are deleted. The figure shows memory slot 1 in which error 001, Interruption loop 1, has been stored (example).
Reset
7
Reset 1 (recalibration)
The loop(s) is/are recalibrated.
Most important technical data
8
Supply voltage /
Power consumption
Loop inductance
Loop connection wiring
Loop resistance
Output relay (loop)
Output relay (alarm)
Dimensions
Housing mounting
Connection type
Protection class
Operating temperature
Storage temperature
Air humidity
SMA / SMA 2 / SMA 220
SMA / SMA 2
24 VAC -20 % to +10%, max. 2 VA
24 VDC -10 % to +20%, max. 1.5 W
SMA 220
100-240 VAC ± 10%, 50/60 Hz, max. 2.9 VA
max. 20 to 1000 µH,
ideally 80
At 20-40 µH: max. 100 m at 1.5 mm
to 300 µH
2
At >40 µH: max. 200 m with 1.5 mm
min. twisted 20x/m
22.5 x 94 x 88 mm (B x H x T)
Direct DIN rail mounting
Plug-in terminals
IP 20
-20°C to +60°C
-40°C to +70°C
<95% non-condensing
Reset 2 (factory setting)
All values (except the error memory) are reset to the factory
settings (see Table 4.11a). The loop(s) is/are recalibrated.
2
SAFETY INSTRUCTIONS
It is the responsibility of the manufacturer to perform a risk assessment and install the detector and the door system in accordance with applicable national and international
The detector may be installed by professionally qualified personnel only. Repairs or attempted repairs by unauthorised personnel will void the warranty. Do not touch the electrical and
regulations and safety standards and, if applicable, in accordance with the Machinery Directive 2006/42/EC.
optical components.
Came S.p.A.- Via Martiri Della Liberta 15 - IT-31030 DOSSON DI CASIER (TV)
TEL (+39) 0422 4940 - FAX (+39) 0422 4941 - info@came.com - www.came.com
Came S.p.A. hereby declares that SMA/SMA2/SMA220 complies with the essential requirements and other relevant provisions of the RoHS Directives 2011/65/EU,
R&TTE 1999/5/EC (until 12/06/2016), RED 2014/53/EU (after 13/06/2016).
Original upon request.