• Use of the products must be restricted to its intended use (i.e. that for which it was expressly built for). Any other use is to be considered dangerous. Came Cancelli Automatici S.p.A. is not liable for any damage resulting from improper, wrongful or unreasonable use • Keep these warnings with the installa­tion and use manuals issued with the automated system.
Before installing
(preliminary check: in case of a negative
outcome, do not proceed before having
complied with the safety obligations)
• Make sure that the parts you intend to automate are in good working order, and that they are properly balanced and aligned. Also, make sure that proper mechanical stops are already in place • If the operator will be installed at a height of less than 2.5 m from the ground or other access level, check whether you will need any protections and/or warnings • Any gate leaves, fi tted with pedestrian entrances, onto which you will install an operator, must have a blocking mechanism when the gate is in motion • Make sure that the opening of the automated gate is not an entrapment hazard as regards any surrounding fi xed parts • Do not mount the operator upside down or onto any elements that may fold under its weight. If needed, add suitable reinforcements at the points where it is secured • Do not install onto gates on either an upward or downward slope (i.e. that are not on fl at, level ground) • Check that any lawn watering devices will not wet the gearmotor from the bottom up.
Installation
• Carefully section off the entire site to prevent unauthorised access, especially by minors and children • Be careful when handling operators that weigh more than 20 Kg (see installa­tion manual). In such cases, employ proper weight handling safety equipment • All opening commands (e.g. buttons, key selectors, magnetic detectors, etc.) must be installed at least
1.85 m from the gate’s area of operation perimeter - or where they cannot be reached from the outside of the gate. Also, the direct commands (e.g. push button, or proximity devices, etc.) must be installed at a height of at least 1.5 m and must not be accessible to the public • All ‘maintained action’ com­mands, must be placed where the moving gate leaves, transit areas and driveways are completely visible • If missing, ap­ply a permanent label that shows the position of the release mechanism • Before delivering to the client, verify that the system is EN 12453 (impact test) standard compliant. Make sure that the operator has been properly adjusted and that the safety and protection devices, as well as the manual release
are working properly • Where necessary and in plain sight, apply the Warning Sings (e.g. gate plate).
Special instructions and
advice for users
• Keep the gate’s area of operation clean and clear of any obstacles. Trim any vegetation that may interfere with the photocells • Do not allow children to play with the fi xed com­mand devices, or in the gate’s area of operation. Keep any remote control devices (i.e. transmitters) away from the chil­dren as well • Frequently check the system, to see whether any anomalies or signs of wear and tear appear on the moving parts, on the component parts, on the securing points, on the cables and any accessible connections. Keep any joints (i.e. hinges) lubricated and clean, and do the same where fric­tion may occur (i.e. slide rails) • Perform functional tests on photocells and sensitive edges, every six months. Keep glass panels constantly clean (use a slightly water-moistened cloth; do not use solvents or any other chemical products) • If the system requires repairs or modifi cations, release the operator and do not use it until safety conditions have been restored
• Cut off the power supply before releasing the operator for manual openings. See instructions • Users are FORBIDDEN to carry out ANY ACTIONS THAT THEY HAVE NOT BEEN EXPRESSLY ASKED TO DO OR SO INDICATED in the manu­als. Any repairs, modifi cations to the settings and extraor­dinary maintenance MUST BE DONE BY THE TECHNICAL ASSISTANCE STAFF • On the periodic maintenance log, note down the checks you have done.
Special instructions and
advice for all
• Avoid working near the hinges or moving mechanical parts
• Stay clear of the gate’s area of operation when in motion • Do not resist the direction of movement of the gate; this may present a safety hazard • At all times be extremely careful about dangerous points that must be indicated by proper pictograms and/or black and yellow stripes • When using a selector or command in ‘maintained action’ mode, keep checking that there are no people in the area of operation of the moving parts. Do this until you release the command • The gate may move at any time without warning • Always cut the power when cleaning performing maintenance.
p.
2
2 - Manual code:
119G M02
119 GM 02 ver.
4
4 05/2013 © CAME Cancelli Automatici S.p.A. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.A . to notify said changes.
ENGLISH
Legend of symbols
This symbol shows parts which must be read with care.
This symbol means the parts which describe safety issues.
This symbol tells you what to tell the end-user.
The GARD operator is designed and built by CAME Cancelli Automatici S.p.A.
G2500/G2500N - Barrier with irreversible, 230 V AC gearmotor, galvanised steel cabinet, control panel and internal command.
NB - You must request right or left-side barriers when ordering. In this manual only left-hand barriers are shown.
Required accessories:
G0251 - White varnished, aluminium barrier-arm with 60x40 mm section, L = 2700 mm.
Optional accessories:
G0461 - Package of re ecting red strips; G0462 - Fixed rest for barrier-arms; G0257 - Joint for the G0251 (maximum length of the barrier-arm is 2.0 m).
Important! Make sure that the command and safety equipment and accessories are CAME originals; this ensures easy and safe installation and maintenance for your system.
4 Description
“IMPORTANT SAFETY INSTALLATION INSTRUCTIONS”
“WARNING: IMPROPER INSTALLATION MAY RESULT IN SERIOUS HARM. PLEASE FOLLOW ALL INSTALLATION INSTRUCTIONS”
“THIS MANUAL IS INTENDED ONLY FOR PROFESSIONAL INSTALLERS OR OTHER COMPETENT INDIVIDUALS”
4.1 Gearmotor
2.1 Intended use
2 Conditions of use
The GARD automatic barrier is designed to be used in both public and private parking facilities, and in residential settings.
Any installation and use other than that specified in this manual is forbidden.
3 Reference standards
2.2 Limitations to use
Passage width up to 2 metres with 5 to 4 seconds opening time.
C am e C an ce l li Au to ma ti c i e mp lo y s a n I SO 9 00 1:14 00 1 c er ti f ie d quality management system and an ISO 14001 environmental management system. Came entirely engineers and manufactures in Italy.
This product is compliant with: see statement of compliance.
3
4
8
5
2
6
7
1
9
p.
3
3 - Manual code:
119G M02
119 GM 02 ver.
4
4 05/2013 © CAME Cancelli Automatici S.p.A. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.A . to notify said changes.
ENGLISH
4. 2 Technical data
4.3 Technical description
OPERATOR ASSEMBLY UNIT
1. Steel sheeting cabinet, 2 mm thick with galvanised finish. Var n i s h e d ( G 2 5 0 0 , R A L 2 0 0 4 , G 2 5 0 0 N t e x t u r e d g r e y ) . I n s p e c t i o n f l a p with customised key.
2 . G a l v a n i s e d f i n i s h , s t e e l a n c h o r i n g - b a s e c o m p l e t e w i t h f o u r c l amps and relative nuts and bolts for fastening the cabinet to the
floor.
3. Barrier-arm attachment flange with galvanised finish. for blocking the barrier-arm quickly and safely.
4. - Gearmotor release activated by a customised key.
5. 230 V AC powered motor. Irreversible gearmotor with cast aluminium casing. inside of which operates a worm-screw based reduction system with permanent fluid grease lubrication. All rotating elements are fitted on permanently-lubricated ball­bearings or self-lubricating ball-joints.
6. Counter-weight movement balancing spring.
7. Inner mechanical safety stops.
8. Limit-switch assembly.
9. ZC5 Control panel
Power supply 230 V AC - 50 / 60 50/60 Hz
Motor power supply 230 V AC - 50 / 60 50/60 Hz
Maximum draw.
1 A
Power rating 120 W
Maximum Torque. 70 Nm
Reduction ratio 1/2 02
Opening interval 4 s
Duty cycle 30%
Protection rating IP54
Weight 40 Kg
Working temperature - 20° / + 55°
Insulation class
260
265 220
275
=
1007
884
=
p.
4
4 - Manual code:
119G M02
119 GM 02 ver.
4
4 05/2013 © CAME Cancelli Automatici S.p.A. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.A . to notify said changes.
ENGLISH
Make sure you have all the tools and materials needed to carry out the installation in total safet y and in accordance with current regulations. The figure shows some examples of the tools needed by installers.
Before installing the operator, do the following:
• Check that the installing the operator does not create and hazardous situations; Set up a suitable omnipolar cut-off device, with distances greater than 3 mm between contacts, with se ctioned power supply;
Check that any connections inside the container (made for continuity purp oses of the protective circuit) be f itted with ex tra
insulation compared to other internal conductive parts;
• Set up proper conduits and electric cable raceways, making sure these are protected from any mechanical damage;
Installation must be carried by skilled, qualified technicians in accordance with current regulations.
5 Installation
4.4 Overall dimensions
Measurements in mm
5.1 Preliminary checks
5.2 Tools and equipment
1
3
7
6
4
10
8
5
9
2
p.
5
5 - Manual code:
119G M02
119 GM 02 ver.
4
4 05/2013 © CAME Cancelli Automatici S.p.A. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.A . to notify said changes.
ENGLISH
N.B. If cables are of a different length than that shown in the table, determine the cable section based on the ac tual draw and the numb er of connected devices and according the what is set forth in the CEI EN 60204-1 code of regulations. For connections requiring several loads on the same line (i.e. sequential ones), the dimensions shown on the table must be reconsidered according to the total draw and actual distances.
1. GARD unit
2. Control panel
3. Aluminium barrier arm
4. Red reflective strips
5. Movement flashing light
6. Small post for photocells
7. Safety photocells
8. Sensor post
9. Transponder sensor
10. Antenna
5.3 Type of cable and minimum thicknesses
5.4 Standard installation
Connection for
Type of
cable
Cable length
1 < 10 m
Cable length
10 < 20 m
Cable length
20 < 30 m
Power supply 230 V 2F
FROR CEI
20-22
CEI EN
50267-2-1
3G x 1.5 mm
2
3G x 2.5 mm
2
3G x 4 mm
2
Photocell transmitters 2 x 0.5 mm
2
2 x 0.5 mm
2
2 x 0.5 mm
2
Photocell receivers 4 x 0.5 mm
2
4 x 0.5 mm
2
4 x 0.5 mm
2
Accessories power supply 24 V DC 2 x 0.5 mm
2
2 x 0.5 mm
2
2 x 1 mm
2
Safety and command devices 2 x 0,5 mm
2
2 x 0.5 mm
2
2 x 0.5 mm
2
Antenna connection RG58 max. 10 m