4 05/2013 © CAME Cancelli Automatici S.p.A. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.A . to notify said changes.
ENGLISH
Installer's stamp Product name
Date of job
Technician's signature
Customer's signature
Job carried out _______________________________________________________________________________________
__________________________________________________________________________________________________
_______________________________________________________________________________________________
Installer's stamp Product name
Date of job
Technician's signature
Customer's signature
Job carried out _______________________________________________________________________________________
__________________________________________________________________________________________________
_______________________________________________________________________________________________
9.3 Troubleshooting
PROBLEM REF. CHECK
The operator neither opens nor closes
1-2-3-4 6-8-18
1 - Lock the inspection hatch using the key and check the release
lock
The operator opens but does not shut. 4-7-10 2 - Deactivate the "maintained action" function via Dip-switch
The operator closes but does not open 4-7-9 3 - Check power supply and fuses
The operator does not carry out the automatic
closing
11-12-13 4 - The N.C. safety contacts are open
The radio-control does not work 2-14-16 6 - Deactivate the master-slave function
The operator inverts the direction of travel 7-18 7 - Check balancing and taughtness of springs
Only one radio-control works. 22 8 -Deactivate the obstacle detection function via dip switch
The photocell does not work 12-23-24 9- Check opening limit-switch
The led warning light flashes quickly 4 10- Check closing limit-switch
The led warning light stays lit. 13 11- Activate "automatic closing" via the Dip-switch
The operator does not fully complete cycle 7 12 - Check for the proper direction of travel
Cannot balance the arm 7-15 13 - Check the command devices
The operator does not decelerate 7-15
14 - Cut off and bring back power to card or check the TOP/TAM
jumper on the AF43S card
The operator does not run on the emergency
batteries
8-25-26 15 - Check the Arm length/applied accessories ratio”
The operator is slow when starting 7 Memorise the radio code again
18 - Adjust sensitivity
22 - Enter or duplicate the same code in all transmitters
23 - Activate the photocell via Dip-switch
24 - Connect the photocells in series and not in parallel fashion
25 - Check the batteries
26 - Respect the polarities when powering up the photocells
Installer's stamp Product name
Date of job
Technician's signature
Customer's signature
Job carried out _______________________________________________________________________________________
__________________________________________________________________________________________________
_______________________________________________________________________________________________