“CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION INSTRUCTIONS CAREFULLY”
“THIS MANUAL IS ONLY FOR PROFESSIONAL OR QUALIFIED INSTALLERS”
1 Legend of symbols
This symbol tells you to read the section with particular care.
This symbol tells you that the sections concern safety issues.
This symbol tells you what to say to the end-users.
ENGLISH
2 Conditions of use
2.1 Intended use
The BX-74 motor is designed to operate residential sliding gates; while, the BX-78 may also be used in condominiums.
Do not install or use unless as otherwise shown in this manual.
2.2 Limitations to use
BX-74: max weight of the gate is 400 kg.
BX-78: max weight of the gate is 800 kg; for condominium use it is 600 kg.
3 Reference standards
The company CAME cancelli automatici is ISO 9001:2000 quality certified; it has also obtained the ISO 14001 environmental safeguarding certification. CAME engineers and manufactures all of its products in Italy.
This product complies with the following legislation: see declaration of compliance.
4 Description
4.1 Operator
This product is engineered and manufactured by CAME CANCELLI AUTOMATICI S.p.A. in compliance with current safety standards.
Guaranteed 24 months if not tampered with.
The operator is made of a cast aluminium part inside of which operates the irreversible, electromechanical gearmotor and an ABS
plastic lining which holds the electronic card and transformer
Important! Check that the command, safety equipment and accessories are CAME originals; this guarantees and make the installation easy to operate and maintain.
4.2 Technical features
BX-74 OPERATOR
Control panel power supply
: 230V A.C. 50/60Hz
Operator power supply: 230V A.C. 50/60Hz
Draw max.: 2,6A
Power: 200W
Max Torque: 24 Nm
Reduction ratio: 1/33
Thrust: 300 N
Max speed: 10 m/min
Operative intermittence: 30%
Protection rating: IP54
Insulation class: I
Weight: 15 kg
Capacitor: 12 µF
Engine thermoprotection: 150° C
#
#
BX-78 OPERATOR
Control panel power supply
: 230V A.C. 50/60Hz
Operator power supply: 230V A.C. 50/60Hz
Draw max.: 2,4A
Power: 300W
Max Torque: 32 Nm
Reduction ratio: 1/33
Thrust: 800 N
Max speed: 10 m/min
Operative intermittence: 30%
Protection rating: IP54
Insulation class: I
Weight: 15 kg
Capacitor: 20 µF
Engine thermoprotection: 150° C
1 - Top cover
2 - Settings casing
3 - Control board support
4 - Endstop fins
5 - ZB74-78 electronic card
6 - Front cover to control panel
7 - Gearmotor release door
8 - Securing plate
9- Securing bolt
10- Securing screw plate
11- Nut
1
4
2
3
6
ENGLISH
5
11
7
2
10
8
9
4.4 Dimensions
(mm)
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
5 Installation
Installation must be carried out by expert qualified personnel and in full compliance with current regulations.
5.1 Preliminary checks
Before installing, do the following:
• Make sure that the gate is stable, and that the castors are in good working order and properly greased.
• The ground rack must be well secured to the ground, entirely above the surface and free of any irregularities that may obstruct the
gate’s movement.
• The upper guide rails must not create any friction.
ver.
• Make sure that there is a closing and an opening endstops.
• Make sure that the operator is attached to a solid surface and protected from any impacts;
• Make sure you have a suitable omnipolar cut-off device with contacts more than 3 mm apart, and independent (sectioned off) power
119 BU 56
:
supply;
• Check that any connections inside the container (that provide continuity to the safety circuit) are fitted with additional insulation
compared to other internal live parts;
Manual code
• Make sure you have suitable tubing and conduits for the electrical cables to pass through and be protected against mechanical
3 -
damage.
Pag.
5.2 Tools and materials
4
119B U 56
1.0
Make sure you have all the tools and materials you will need for the installation at hand to work in total safety and compliance
with the current standards and regulations. The following figure illustrates the minimum equipment needed by the installer.
ENGLISH
5.3 Cable list and minimum thickness
ConnectionType of cable Length of cable 1 < 10 mLeng. cable 10 < 20 m Leng. cable 20 < 30 m
Control panel power supply 230V
3G x 1,5 mm
Flashing light2 x 0,5 mm
Photocell transmitter2 x 0,5 mm
Photocell receiver4 x 0,5 mm
Accessories power supply2 x 0,5 mm
FROR CEI
20-22
CEI EN
50267-2-1
2
2
2
2
2
3G x 2,5 mm
2 x 1 mm
2 x 0.5 mm
4 x 0,5 mm
2 x 0,5 mm
2
2
2
2
2
3G x 4 mm
2 x 1,5 mm
2 x 0,5 mm
4 x 0,5 mm
2 x 1 mm
2
2
2
2
2
Safety and control devices2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 0,5 mm
2
Antenna connectionRG58max. 10 m
N.B.: If the cable length differs from that specified in the table, then you must determine the proper cable diameter in the basis of
the actual power draw by the connected devices and depending on the standards specified in CEI EN 60204-1.
For connections that require several, sequential loads, the sizes given on the table must be re-evaluated based on actual power
draw and distances. When connecting products that are not specified in this manual, please follow the documentation provided
with said products.
5.5 Securing the plate and installing the assembly
5
119B U 56
1.0
The following applications are only examples, as the space for installing the ratiomotor and accessories varies according to
obstructions. It is thus up to the system installer to select the most suitable solution.
- Dig a pit to the side of the gate (see measurements from diagram).
Prepare the corrugated tubes you will need when making connections coming from the shunt pit.
N.B. the number of tubes depends on the type of system and the accessories you will hook up.
Conduits for electric
cables
Shunt pit
ENGLISH
- Prepare a form box that is larger in size than the securing plate and insert it into the pit. The form box should jut 50mm above
ground level.
Insert an iron grid inside the from box to reinforce the concrete.
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
-Prepare the securing plate, insert the bolts into the holes and lock them using the supplied nuts and washers. Extract the preformed
brackets using a screw driver or a set of pliers.
- Position the plate on top of the grid. Careful! The tubes need to pass through the apposite holes.
- To position the plate in relation to the rack please see the measurements on the diagram.
6
119B U 56
1.0
Fill the form box with cement and wait for at least 24 hours for it to solidify.
ENGLISH
- Remove the form box, fi ll the pit around the cement block with soil.
H
- Unbolt the nuts and washers from the bolts. The securing plate must be clean, perfectly aligned and with the bolt threads completely
on the surface.
Insert the electric cables into the tubes until they exit about 400mm.
- Remove the cover from the gearmotor by loosening the side bolts, perforate the cable shafts using a screwdriver or a pair of
7
119B U 56
1.0
scissors and position the gearmotor atop the plate. Careful! The electric cables must pass through the cable shafts.
- Lift the gearmotor from the securing plate by about 5 to 10mm by using the threaded steel-levelling feet to allow any later
adjustments between the pinion and the rack.
ENGLISH
- The following illustrations for the securing the rack, are just examples of applications. It is up to the installer to choose the best
solution.
Releasing the gearmotor (see paragraph on manual release). Rest the rack on the gearmotor pinion.
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
Weld or secure the rack to the gate along its entire length.
To assemble the rack modules, use an excess piece of rack and place it under the joining point, then block it using two C-clamps.
Note: if a rack is already in place, then just adjust the pinion-to-rack distance.
- Open and close the gate manually and register the pinion-to-rack distance using the threaded steel-levelling feet (for vertical
8
119B U 56
1.0
adjusting) and the slotted holes (horizontal adjusting). This prevents the weight of the gate from bearing on the operator.
Rack
Rack
ENGLISH
Levelling feet
Pinion
vertical adjusting
Pinion
Slotted holes
horizontal adjusting
Once adjustments are fi nished, secure the assembly using the nuts and washers.
Insert the cover after performing the adjustments and settings on the electronic card.
Place the endstop fi ns onto the rack and secure them using a 3 mm Allen wrench. Their positioning limits the gate run.
Note: the gate schould not slam against the mechanical stop, when opening or closing.
Mechanical stop
5.7 Manually releasing the gearmotor
ENGLISH
- Insert the trilobed key into the lock, push it in and turn it clockwise ....
Trilobed key
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
..... open the small door and turn the release handle clockwise.
WARNING: opening the door will
disengage the motor (i.e. it will not
function).
To operate the motor the release mechanism must be fi rmly fastened.
6 Control board
• • • • ••
•
•
10
119B U 56
1.0
6.1 General description
Use 230V A.C. to power the electronic card using the L-N
terminals, at a max 50/60Hz frequency.
Use 24V to power the command devices and accessories.
Careful! The accessories cannot exceed 20W of overall power.
The photocells may be set up for re- opening during closing (2C1), partial stop, total stop and obstacle detection when motor
is stopped.
ENGLISH
Note: when a normally closed safety contact (i.e. 2-C1, 2-C3 or
1-2) is opened, the signalling LED starts to fl ash (ref. point 11,
main components).
The optical reader inverts the gate’s direction of travel when it
detects and obstacle during its opening and/or closing movement.
Warning: after 3 obstacle detections, the gate stops when in
opening-mode and excludes automatic-closing mode; to regain
movement press the command button or use the remote control.
All connections are protected by quick-fuses – see table.
The card handles the following functions:
- Automatic closing after an opening command;
- Warning light pre-fl ashing;
- Obstacle detection when gate is still at any point;
The following command modes are possible:
- Opening/closing;
- Opening/closing in maintained action mode;
- partial opening;
- total stop.
Apposite trimmers regulate:
- The automatic closing’s running time;
- The partial opening;
Warning! Before acting on the machinery, cut off the main power
supply and disconnect any emergency batteries.
TECHNICAL INFORMATION
Power supply 230V - 50/60 Hz
Maximum power allowed 200 W (BX74)
300 W (BX78)
Absorption at rest 2,6A (BX74)
2,4A (BX78)
Max power of 24V accessories 20 W
FUSE TABLE
To protect: fuse:
Control board (line) 5A-F
Accessories 1A-F
Command devices 630mA-F
6.2 Main components
White
1
2
••••••
4
8
••
Red
Black
Violet
Orange
Blue
ON
1234
1 - Power supply terminals
2 - Line fuse
3 - Accessory fuse
4 - Card fuse
5 - Button for memorising the radio code
6 - Trimmer PAR.OP.: Partial opening adjustment
7 - Trimmer A.C.T.: Automatic closing time adjustment
8 - Function selector (4) DIP switch
9 - Function selector (10) DIP switch
10 - Socket for connecting the remote control’s
11 - Radio-code signalling LED indicator
12 - Accessories’ and command device’s terminals
Description of the standard electrical connections for left-hand installations
Closing microswitch
COM
NC
COM
NC
Opening microswitch
Orange
Red
Orange
White
Modifications to the electrical connections for right-hand installations
COM
NC
COM
Orange
Red
Orange
Black
Red
ENGLISH
COM
Condenser
Black
Red
Invert the gearmotor (U-V) and (FA-FC) endstop phases.
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
Cable lug with bolt and washer for connecting to earth.
+
-
COM
Manual code
11 -
Pag.
Warning devices
12
119B U 56
1.0
Movement fl ashing light (Contact range: 230V – 25W max)
- Flashes during the gate’s
opening and closing phases.
ENGLISH
Cycle lamp: (contact rating:
230V – 60W max.).
It lights up the driving area and
stays on from the moment the
gate begins to open until it is
fully closed (including the automatic closing time). If automatic
closing is not activated, the lamp
stays on only during movement.
Set DIP 1 and 6 switch to ON.
Open-gate status light
(contact range: 24V – 3W
max)
- Signal that gate is open;
turns off when gate is
closed.
Close-gate status light
(contact range: 24V – 3W
max)
- Signal that gate is close;
turns off when gate is
open.
Command and control devices
Stop button (N.C. contact)
- Gate stop button. Excludes automatic closing. For motion to resume, press the
command button or the remote control button.
N.B.: If unused, set DIP 9 switch to ON.
- Gate opening and closing command. By pressing the button or turning
the selector key, the gate inverts its movement or stops depending on
which the settings on the DIP switches.
- Input for EN 12978 standard-compliant safety
devices such as photocells. Gate stops if moving and
automatically shuts (if this functions has been selected).
(N.C.) contact for «re-open during closing phase»
- Input for EN 12978 standard-compliant safety
devices such as photocells. If contact is opened, while
gate is closing, the gate inverts its direction.
RX
RX
DIR photocells
DIR photocells
TX
ENGLISH
TX
«Partial stop» (N.C.) contact
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
1 ON - Automatic Closing - The automatic closing timer activates at the end of the opening gate run. The pre-set time is adjustable,
ENGLISH
and is in any case conditioned by the activation of any safety devices, and does not activate after a total safety “stop” or
during a blackout.
2 ON - "Open-stop-close-stop" function with [2-7] button and radio transmitter (fi tted with inserted radiofrequency card).
2 OFF - "Open-close" function with [2-7] button and radio transmitter ((fi tted with inserted radiofrequency card).
3 ON - "Open only" function with radio transmitter ((fi tted with inserted radiofrequency card).
4 ON-Maintained action - The gate works by keeping button pressed (one 2-3P opening button , and one 2-7 closing button).
5 ON - Pre-Opening and closing fl asher - Following and opening and closing command, the fl asher connected to [W-E1], fl ashes
for 5 seconds before motion begins.
6 ON - Obstacle detected - When motor is stopped (gate closed or after a total stop command) it prevents any movement if safety
devices, such as photocells, detect any obstacles.
7 OFF - Opening during closing - If t he ph ot oc el ls de tec t a n o bs ta cl e d ur in g g at e’ s c lo si ng , g at e m ot ion is in ve rt ed unt il fu ll y o pe ne d;
connect the safety device to terminals [2-C1]; if unused, set DIP switch to ON.
8 OFF - Partial stop - Gate stop when obstacle is detected by the safety device; once obstacle is removed, the gate remains still or
closes if automatic closing is activated. Connect the safety device to terminal [2-C3]; if unused, set the DIP switch to ON.
9 OFF - Total stop - This function stops the gate and then excludes any automatic closing cycle; to set in motion again, use either
the keypad or transmitter. Insert the safety device in [1-2]; If unused, set DIP switch to ON.
10 OFF Limit switch slowing activated
DIP-SWITCH 4
1 ON - Closing only – with command device connected on contact 2-7 (1 OFF – deactivated)
1 OFF - Open-close – with command device connected on 2-7 (see 10-way Dip Switch 2 of the function selector) (1 ON – deactivated).
2 ON - Only opening – with command device connected on contact 2-3P (2 OFF – deactivated).
2 OFF - Partial opening – with command device connected on contact 2-3P (2 ON – deactivated).
3 ON - Optical readerdeactivated; (3 OFF –activated); to program deceleration you need to activated the optical reader.
4 ON - disconnected
NOTE: make selections when motor is stopped and in the closed position.
6.5 Settings
••••
••
••
ON
ON
1234
1234
5678
910
AF
!#4
Trimmer A.C.T. =Sets the waiting time while open. Once this time has elapsed, closing automatically takes place. The waiting time
may be set from 1 to 120 seconds.
Trimmer PAR.OP. = Sets the gate’s partial opening. By pushing the partial opening button connected at 2-3P, the gate will open for
a set time between 0 and 16 seconds.
So as to fully meet the compliance requirements established by European Standards EN 12445 and EN 12453 on matters concerning
maximum impact forces, BX-74/78 is set up for deceleration at 50 cm from the opening and closing endpoints. When installing all you
need to do is program the gate operation as follows:
Before proceeding, set all the DIP SWITCHES to OFF (10-way Dip Switches)
a) - Set Dip Switch 4, 7, 8 and 9 to ON (10-way Dip Switch) and Dip Switch 3 e to OFF (4-way dip-switch, optical reader);
b) - press CH1 until the red LED starts fl ashing (after about 3 secs). After which, the gate will fully open and close.
c) - when the led stays on, this means the programming procedure is fi nished;
d) - reset the DIP SWITCHES to the previous setting, which is determined by the selection of functions (see parag. 6.4 on p. 14).
“DIP-SWITCH 10”
a)
“DIP-SWITCH 4”
b)
910
5678
34
c)
d)
34
5678
910
ENGLISH
The decelerated gate operation speed may be changed by simply pressing CH1 (to reduce it) or CH2 (to increase it) while the
operator is decelerating.
NOTE: When the card is initially activated, the PROG LED will fl ash rapidly, and in so doing signalling that the card is not programmed;
once programmed the LED will remain off.
To exclude decelerations, set Dip Switch 10 to ON.
If power is cut off during gate closure operation and decelerations have been activated, once the power comes back on, the operator
always and for safety reasons, will perform a full, decelerated opening and closing cycle.
6.7 Modifying the Re-closing Partial Stop during opening
With BX-74/78 you can change the function of the Re-closing Partial
Stop during opening, which is connected on 2-C3.
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
To activate it, do the following:
a) - Set Dip Switch 1 and 4 on ON;
b) - press CH1: the red LED will start to fl ash;
c) - when the LED stays lit up (after about 5 secs) this means that
the procedure is fi nished;
d) - reset the DIP SWITCHES to the previous setting, which is
determined by the selection of functions (see parag. 6.4 on p. 14).
CH1 = Re-closing during opening (to select)
N.B.: to go back to the default selection, follow the same procedure but
press CH2.
Insert the radio frequency card into the electronic card AFTER DISCONNECTING THE POWER (and disconnecting any batteries).
N.B.: the electronic card picks up the radiofrequency card on when it is running on power
AF Card
Electronic card
•
••
•••••
ENGLISH
Transmitters
CAME
CAME
TOP
TOP-432A • TOP-434A
CAME
ATOMO
AT01 • AT02
AT04
ON
1234
See instruction sheet in AF43SR radiofrequency
TOP
TOP-302A • TOP-304A
ON
1234
910
5678
card box
TOP
TOP-432NA • TOP-434NA
TOP-432S
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
8 Connecting two joined motors with a single command
•••
•
•
•
•
••••
•
•
•
•
•
•••
•
•
•
•
••••
•
•
•
•
•
19
119B U 56
1.0
1) Coordinate the direction of travel of geared motors “A” and “B”, by modifying the rotation of motor “B” (see p. 11 geared motorendstop connection)
A
A
2) Carry out the electrical connections
on the geared-motor “A” command
card as per paragraph 6.3 electrical
connections.
3) On both cards, carry out the same settings and activate the same functions (Dip Switches)
A
ON
ON
910
5678
1234
1234
B
ENGLISH
B
ON
ON
910
5678
1234
1234
4) Carry out the connections between the two command cards as per the fi gure.
Note: the (2-3P) partial opening button needs to be connected to the command card’s terminal board of the motor in question
(motor A for opening left-wards, and B for opening right-wards).
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
5) On the geared motor A’s command card, insert the AF radio card.
119 BU 56
Activate the radio command, using the CH2 channel (see chapter 7).
:
After memorising the code, connect contacts B1 and B2 on contacts 2 and 7.
On both cards, select the type of command (see Dip-Switches 2 and 3).
Manual code
19 -
Pag.
9 Safety instructions
20
119B U 56
1.0
Important safety instructions
This product must only be employed for its originally intended use. Any other use is wrong and potentially dangerous. The
manufacturer cannot be held liable for any damages resulting from wrongful, erroneous or negligent uses.
Avoid working close to the hinges or other moving mechanical parts. Stay out of the opening/closing arc when operator is in
motion.
Do not exercise force against the motion of the operator as this could result in potentially dangerous situations.
ENGLISH
Do not allow children to play or loiter within the opening/closing arc of the operator. Keep remote controls and any other command
device out the reach of children, to prevent operator from being activated by accident.
In the event of anomalous behaviour, stop using the operator immediately.
Periodic maintenance to be carried out by the end-user is as follows: wipe clean the glass surface of the photocells;
check that the safety devices work properly; remove any obstructions.
We suggest checking the state of lubrication and tightness of the anchoring screws on the operator.
-To check the efficiency of the safety devices, move an object in front of the photocells when gate is closing. If the operator
inverts the motion or stops, the photocells are working properly.
This is the only maintenance procedure to be carried out with the power source connected.
-Before performing any maintenance procedures, cut off the main power, to prevent possible accidents due to gate movement.
-To clean the photocells use a water dampened cloth. Do not use solvents or other chemical products which may ruin the
devices.
-In the event of any strange vibrations or squeaking, lubricate the joints with grease, as shown in the diagram.
ENGLISH
-Make sure there are no plants within the photocell’s beam, and that the gate motion is free of any obstacles.
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
• The gearmotor is in release mode and the release door is open
• The transmitter’s batteries are run down
• The transmitter is broken
• The stop button is either stuck or broken
• The opening/closing button or the key selector are stuck
• Fhotocells in partial stop mode
• The photocells are engaged
• Check that the power is up
• Call assistance
• Replace batteries
• Call assistance
• Call assistance
• Call assistance
• Call assistance
• Check that photocells are clean and
in good working order
• Sensitive edge triggered
• Call assistance
• Sensitive edge triggered• Call assistance
The flasher does
Manual code
not work
21 -
Pag.
• The bulb is burnt• Call assistance
Periodic maintenance log for end-user (every 6 moths)
22
119B U 56
1.0
ENGLISH
DateNotes
Signature
10.3 Extra-ordinary maintenance
The following table serves to note down any extraordinary maintenance, repairs or improvements performed by specialised firms.
N.B.: Any extraordinary maintenance must be performed by specialised technicians.
CAME CANCELLI AUTOMATICI S.p.A. employs a UNI EN ISO 14001 certified and compliant environmental protection system at its plants, to ensure that environmental safeguarding.
We ask you to keep protecting the environment, as CAME deems it to be one of the fundamental points of its market operations
strategies, by simply following these brief guidelines when disposing:
DISPOSING THE PACKING MATERIALS
The packing components (cardboard, plastic, etc.) are solid urban waste and may be disposed of without any particular difficulty,
by simply separating them so that they can be recycled.
Before actions it is always advisable to check the pertinent legislation where installation will take place.
DO NOT DISPOSE OF IN NATURE!
ENGLISH
DISPOSING OF THE PRODUCT
Our products are made using different types of materials. The majority of them (aluminium, plastic, iron, electric cables) can be
considered to be solid urban waste. They may be recycled at authorised firms.
Other components (electrical circuit board, remote control batteries etc.) may contain hazardous waste.
They must, thus, be removed and turned in to licensed firms for their disposal.
Before acting always check the local laws on the matter.
DO NOT DISPOSE OF IN NATURE!
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
12 Conformity declaration
MANUFACTURER’S DECLARATION OF CONFORMITY
CAME Cancelli Automatici S.p.A.
via Martiri della Libertà, 15
31030 Dosson di Casier - Treviso - ITALY
tel (+39) 0422 4940 - fax (+39) 0422 4941
internet: www.came.it - e-mail: info@came.it
Declares under its own responsibility that the equipments for automatic garage doors and gates listed below:
BX-74 / BX-78
… comply with the National Law related to the following European Directives and to the applicable parts of the
Moskva - RUSSIA
(+7) 495 937 33 07
(+7) 495 937 33 08
English - Manual code:
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
CAME Cancelli Automatici S.p.a.
Via Martiri Della Libertà, 15
31030
Dosson Di Casier (Tv)
(+39) 0422 4940
(+39) 0422 4941
20093
CAME Nord s.r.l.
Piazza Castello, 16
Cologno Monzese (MI)
(+39) 02 26708293
(+39) 02 25490288
Informazioni Commerciali 800 848095
www.came.it
CAME Service Italia S.r.l.
Via Della Pace, 28
31030
Dosson Di Casier (Tv)
(+39) 0422 383532
(+39) 0422 490044
Assistenza Tecnica 800 295830
CAME Sud s.r.l.
Via F. Imparato, 198
Cm2 Lotto A/7
80146
Napoli
(+39) 081 7524455
(+39) 081 7529109