Cambium Networks cnPilot e435W Indoor Quick Start Manual

Model: cnPilot e435W Indoor
Dual Gang Mounting General Wall Mounting Desktop Mounting
Introduction
The guide provides a quick installation process.
Tool Requirements
Single Gang Mounting
• Philips Head Screwdriver
• Torx Security Screwdriver
Single Gang Mounting
JOIN THE CONVERSATION
Product Overview
Package Contents
e435W Access Point
Torx Screw Size: M3 x 6mm Quantity: 1
Single Gang Wall Bracket
Ethernet Jumper Cable
Tools Required
Multi-color LED
Dual Gang Mounting
Secure e435W to the bracket with a screw at the bottom edge of e435W using standard Torx security screw or standard Philips head screw.
PASS THRU
48V/ 1A
Kensington Lock Slot
Reset Button
cnPilotTM e435W Indoor
802.11ac Wave2 Dual Band Wall Plate Wi-Fi Access Point
Quick Start Guide
Air vents
ETH2
ETH3
ETH4/ PoE OUT
Slots for bracket mounting
Eth1/ PoE IN
PASS THRU
Connect Ethernet cable to the upper RJ-45 port labeled Eth1/PoE at the rear side of e435W to provide connectivity. Use the other RJ-45 port labeled PASS-Through for any additional cable that might need to pass through e435W.
Remove single-gang box cover.
Place Cambium single-gang wall bracket on the gang box and secure with at least 2 screws.
1.
2.
3.
5.
Align the two slots at rear side of the e435W with two hooks on the bracket.
4.
Remove dual-gang box cover.
1.
2.
4.
Connect Ethernet cable to the upper RJ-45 port labeled Eth1/PoE at the rear side of e435W to provide connectivity. Use the other RJ-45 port labeled Pass-thru for any additional cable that might need to pass through e435W.
Align the two slots at rear side of the e435W with two hooks on the bracket.
5.
Secure e435W to the bracket with a screw at the bottom edge of e435W using standard Philips head or Torx security screwdriver.
6.
Place Cambium dual-gang wall bracket on the gang box and secure with at least two screws.
Choose location on the wall to mount the bracket using the four mounting screws and anchors (if needed).
Connect the short Ethernet jumper cable between the two RJ-45 connections on the rear side of e435W.
Secure e435W to the bracket using Torx (or standard) screw on the lower edge of e435W.
Connect the short Ethernet jumper cable between the two RJ-45 connections at the rear side of e435W.
Philips Head Screw Size: M3.5 x 25mm Quantity: 4
1.
2.
Mount e435W into the Generic Wall bracket by aligning the hooks
3.
4.
Power e435W either with a 48Vdc/1A power adapter or using the PASS-THRU port at the bottom edge of the device using Ethernet power.
5.
1.
Insert the e435W into the desk stand plastic jumper cable cover.
Secure the e435W and plastic jumper cable cover to the metal stand by aligning the screw holes and inserting Torx screw.
2.
3.
Power e435W either with a 48Vdc/1A power adapter or using the PASS-THRU port at the bottom edge of the device.
4.
3.
Slide the plastic cover over the exposed portion next to the mounted e435W.
Philips Drive Pan Head Screw Size: M3 x 6mm Quantity: 1
AP Management
Safety Notice
Configure Management PC
Specifications
Hardware Overview
Hardware Overview
Powering Up
The cnPilot e435W Access Point supports multiple modes of
management:
Standalone: The Access Point can be managed directly from its GUI by
selecting the ‘Configure’ tab on the menu, and setting up a wireless LAN.
Controller : The Access Point can be onboarded to cnMaestro network
controller system, either on-premises or the cloud version at
https://cloud.cambiumnetworks.com.
For management from cloud please ensure the AP has connectivity to
the internet. Connectivity can be verified using tools such as ping from
the ‘Troubleshooting’ tab of the Access Point GUI. Connection status can
be monitored from the AP dashboard.
1.
2.
3..
Select Properties for the Ethernet port. In Windows it is found in Control Panel > Network and Internet > Network Connections > Local Area Connection.
IP Address Configuration: Default IP address is received via DHCP. cnPilot e435W will use a default static IP address of 192.168.0.1, If there is no DHCP server.
Default Login information
- Username: admin
Management Protocols enabled by default –http or https (webpage management interface access), SSH (CLI management interface access).
1.
2.
3.
LED Color Amber Green Blue
Status
Indicator
Access Point is powering up and Intitializing
Access Point is in service.
Access Point is managed with cnMaestro or autopilot.
Warning:
To prevent loss of life or physical injury, observe the following safety guidelines. In no event shall Cambium Networks be liable for any injury or damage caused during the installation of e435W platform. Ensure that only qualified personnel install. Only use attachments/accessories specified by the manufacturer.
Electrical Safety Information
Do not substitute the power cord with one that is not the provided approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire.
The equipment requires the use of the ground wire as a part of the safety certification, modification or misuse can provide a shock hazard that can result in serious injury or death.
Contact a qualified electrician or the manufacturer if there are questions about the installation prior to connecting the equipment.
Protective earthing is provided by Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection.
Protective bonding must be installed in accordance with local national wiring rules and regulations.
1.
2.
3.
4.
a.
b.
c.
d.
e.
Compliance with manufacturer’s label for voltage, frequency, and current requirements. Connecting to a dierent power source than those specified may result in improper operation, damage to equipment or pose a fire hazard if the limitations are not followed.
There are no serviceable parts inside this equipment. Service should be provided only by a qualified service technician.
This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet.
Be aware that the unit surfaces can become very hot to the touch so do not handle the device when it is running for long periods of time. Turn o power to the device first for a few minutes and then handle the unit carefully.
FCC Compliance
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions.
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
For product available in the USA/Canada market, only channel 1~11 can be operated. Selection of other channels is not possible. This device is restricted for indoor use. IMPORTANT NOTE: FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
IC Statement:
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
FCC Compliance
For product available in the USA/Canada market, only channel 1~11 can be operated. Selection of other channels is not possible. Pour les produits disponibles aux États-Unis / Canada du marché, seul le canal 1 à 11 peuvent être exploités. Sélection d'autres canaux n'est pas possible.
The device for operation in the band 5150–5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems. les dispositifs fonctionnant dans la bande 5150-5250 MHz sont réservés uniquement pour une utilisation à l’intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de satellites mobiles utilisant les mêmes canaux.
For indoor use only. Pour une utilisation en intérieur uniquement.
IMPORTANT NOTE: IC Radiation Exposure Statement: This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body. Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps.
This radio transmitter has been approved by FCC to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.
Antenna Information: Five single-band antenna, Gain 2.98/4.05dBi
RoHS/WEEE Compliance
Online Resources
User Guide and software downloads: https://support.cambiumnetworks.com/files/e435W/
Support: http://www.cambiumnetworks.com/support/
Contact us: http://www.cambiumnetworks.com/support/contact-support/
Caring for the Environment: RoHS/WEEE
European Directive 2002/96/EC requires that the equipment bearing this symbol on the product and/or its packaging must not be disposed of with unsorted municipal waste. The symbol indicates that this product should be disposed of separately from regular household waste streams. It is your responsibility to dispose of this and other electric and electronic equipment via designated collection facilities appointed by the government or local authorities. Correct disposal and recycling will help prevent potential negative consequences to the environment and human health. For more detailed information about the disposal of your old equipment, please contact your local authorities, waste disposal service, or the shop where you purchased the product.
CE Marking
CE marking on this product represents the product is in compliance with all directives that are applicable to it.
With 802.3af/at PSE
With 802.3af/at PSE switch
With Injector
LAN / Computer
To AC outlet
To AC outlet
LAN / Computer
With 48V Power adapter
48V Power adapter
Cambium 30W injector
Kensington Lock Slot
Reset Button
Eth1/ PoE IN
PASS THRU
PASS THRU
48V/ 1A
ETH2
ETH3
ETH4/ PoE OUT
Reset - To restart, press and hold Reset. To restore to factory default settings, press and hold Reset for more than 10 seconds.
Eth1/ PoE IN - Gigabit Ethernet port used to connect the power. It should be connected
to the LAN and DHCP server.
Eth2/ Eth3 - Spare gigabit Ethernet ports for connecting additional network devices.
Pass Thru - Are electrically connected internally so that in-wall wired non-Ethernet
connectivity to a device in the room can be connected easily through e435W port on the back to the corresponding pass thru port on the bottom edge of the AP. If desired, the Eth1/PoE IN port can be jumpered with a short Ethernet cable and the Pass Thru port on the bottom edge can be used as the main LAN/PoE IN port.
Ethh4/ PoE OUT - Provides DC power to a secondary device and is
802.3af compliant. It detects the device power and connectivity needs dynamically. This port can also be used as a standard Gigabit networking data only port.
DC Power
- e435W can be powered with a 48V/1A power adapter as an alternate to PoE. The power jack is located on the bottom edge of the device next to the Eth4/PoE OUT LAN port.
Kensington Lock Slot - The slot on the side of e435W that can be used to secure the unit
to deter theft with a Kensington Lock device.
Loading...