Cambium Networks 49100 User Manual

PTP 600 Series
User Guide
MOTOROLA POINT-TO-POINT WIRELESS SOLUTIONS
MOTOROLA, Inc.
Point-to-Point Wireless Bridges – PTP 600 Series
Software Release PTP 600-08-xx
System User Guide
December 2nd, 2008
Ref: PHN-0896-08.00
Copyright Information
This document is the confidential property of Motorola, Inc. and without its prior written consent may
not be copied or released to third parties.
MOTOROLA, the stylized M Logo and all other trademarks indicated as such herein are trademarks
of Motorola, Inc.
product or service names are the property of their respective owners.
© 2008-2006 Motorola, Inc. All rights reserved.
http://www.motorola.com/ptp
®
Reg. U.S. Pat & Tm. Office. PTP 600 is a trademark of Motorola, Inc. All other
Compliance
General
Changes or modifications not expressly approved by Motorola could void the user’s authority to
operate the system.
NOTE: This system has achieved Type Approval in various countries around the world. This means
that the system has been tested against various local technical regulations and found to comply. The
frequency bands in which the system operates may be ‘unlicensed’ and, in these bands, the system
can be used provided it does not cause interference. Further, it is not guaranteed protection against
interference from other products and installations.
1
The system has been tested for compliance to both US (FCC) and European (ETSI) specifications. It
has been shown to comply with the limits for emitted spurious radiation for a Class B digital device,
pursuant to Part 15 of the FCC Rules in the USA and appropriate European ENs. These limits have
been designed to provide reasonable
can radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to other radio communications. There is no guarantee that
interference will not occur in a particular installation.
NOTE: A Class B Digital Device is a device that is marketed for use in a residential environment,
notwithstanding use in commercial, business and industrial environments.
If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
x Reorient or relocate the Outdoor Unit (ODU).
x Increase the separation between the affected equipment and ODU.
x Connect the ODU/PIDU into a power outlet on a circuit different from that to which the
receiver is connected.
x Consult your installer or supplier for help.
protection against harmful interference. However the equipment
Deployment and Operation
The Radio Regulations of various countries’ limits constrain the operation of radio products generally.
In particular the local regulator may limit the amount of conducted or radiated transmitter power and
may require registration of the radio link.
The power transmitted by the PTP 600 Series Bridge is controlled by the use of Region-specific
License Keys.
The following examples show how the regulatory limits apply in some specific countries at the current
time. Operators should note that regulations are subject to change.
Contact your supplier/installer to ensure that your product is set for the correct License Key for your
Country/Region and to ensure that you have fulfilled all the local regulatory requirements, especially if
you are intending to use a link with external antennas. Footnotes to the table below indicate countries
where registration of the link is currently mandatory.
2
The system has been tested for compliance to both US (FCC) and European (ETSI) specifications. It
has been shown to comply with the limits for emitted spurious radiation for a Class B digital device,
pursuant to Part 15 of the FCC Rules in the USA and appropriate European ENs. These limits have
been designed to provide reasonable protection against harmful interference. However the equipment
can radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to other radio communications. There is no guarantee that
interference will not occur in a particular installation.
CAUTION: When planning a link that will use Connectorized PTP 600 Series bridges (with
external antennas), ensure that regulatory requirements are met for the installation, as
described in Section 13.6 “Regulatory Issues with Connectorized Units”.
Regulations applicable to PTP 25600 variant
FCC
Examples of Regulatory Limits at 2.5GHz
Under FCC Regulations, operation of this product is only allowed with a License Key for Region 16 which ensures that the product will meet the requirements of FCC part
27.
Note
: Spectrum in this band (2496MHz to 2690MHz) is allocated on a licensed basis
in USA.
Regulations applicable to PTP 45600 variant
Examples of Regulatory Limits at 4.5GHz
Operation of this product is only allowed with a License Key for Region 23 (USA Military).
Regulations applicable to PTP 48600 variant
Examples of Regulatory Limits at 4.8GHz
Operation of this product is only allowed with a License Key for Regions 15 or 23 (USA Military).
Regulations applicable to PTP 49600 variant
Examples of Regulatory Limits at 4.9GHz
Operation of this product is only allowed with a License Key for Region 14 (USA/Canada Public Safety) or Region 18 (Hong Kong Public Safety).
3
Regulations applicable to PTP 54600 variant
FCC
ETSI
Australia, Canada
Thailand
Korea
Examples of Regulatory Limits at 5.4GHz
Operation of this product is only allowed with a License Key for Region
12. This implements Radar Detection in accordance with FCC Regulations and limits the EIRP to the regulatory limits below:
EIRP  Max of [(17 +10 x Log(Channel BW)) and 30] dBm.
Oeration of this product is only allowed with a License Key for Region
26. This implements Radar Detection, including barring of the band from 5600 MHz to 5650 MHz and limits the EIRP to the regulatory limits below:
EIRP  Max of [(17 +10 x Log(Channel BW)) and 30] dBm
Oeration of this product is only allowed with a License Key for Region
13. This implements Radar Detection, including barring of the band from 5600 MHz to 5650 MHz and limits the EIRP to the regulatory limits below:
EIRP  Max of [(17 +10 x Log(Channel BW)) and 30] dBm
Operation of this product is only allowed with a License Key for Region 20 (30 dBm or 1W EIRP)
Operation of this product is only allowed with a License Key for Region 21 (28 dBm EIRP (15 MHz), 27 dBm EIRP (10 MHz), 24 dBm EIRP (5 MHz)).
General Notice Applicable to Europe
This equipment complies with the essential requirements for the EU R&E Directive 1999/5/EC.
NOTE: In regions other than EU/USA, specific local regulations may apply. It is the
responsibility of the installer/user to check that the equipment as deployed meets local
regulatory requirements.
4
Regulations applicable to PTP 58600 variant
USA/ Canada/ Taiwan/ Brazil
China
Australia
Hong Kong
UK
Singapore
Eire
Korea
Examples of Regulatory Limits
Equipment can be operated in any mode, best results will be obtained using Region 1 settings. There are some limitations on the use of antennas above 4ft diameter plus a band edge power reduction.
Operation of this product is only allowed with a License Key for Region 2 (33 dBm or 2W EIRP).
Operation of this product is only allowed with a License Key for Region 3 (36 dBm or 4W EIRP).
Operation of this product is only allowed with a License Key for Region 3 (36 dBm or 4W EIRP).
Operation of this product is allowed with a License Key for Region 4 . This implements Radar Detection with barring of the band from 5795 MHz to 5815 MHz and above 5850 MHz. It limits the EIRP to the Regulatory Limits below:
EIRP  Max of [(23 +10 x Log(Channel BW)) and 36] dBm
Operation of this product is only allowed with a License Key for Region 5 (20 dBm or 100mW EIRP).
Operation of this product is only allowed with a License Key for Region 6 (33 dBm or 2W EIRP). The lower power limits are lower in narrower bandwidths.
Operation of this product is only allowed with a License Key for Region 11 (43 dBm or 20W EIRP).
Operation of this product is only allowed with a License Key for Region 19 (36
India
Thailand
Germany Operation of this product is only allowed with a License Key for Region 22. This
Bahrain Operation of this product is allowed with a License Key for Region 24 . This
Norway Under Norway Regulations, operation of this product is only allowed with a
dBm or 4W EIRP at 15 MHz and 10 MHz and 33 dBm or 2 W EIRP at 5 MHz channel bandwidth).
Operation of this product is only allowed with a License Key for Region 20 (30 dBm or 1W EIRP).
limits the band of operation to 5755 MHz to 5850 MHz and limits the EIRP to the Regulatory Limits below:
EIRP  Max of [(23 +10 x Log(Channel BW)) and 36] dBm
limits the EIRP to the Regulatory Limits below:
EIRP  Max of [(20 +10 x Log(Channel BW)) and 33] dBm
License Key for Region 7. This implements Radar Detection and limits the EIRP to the Regulatory Limits below:
EIRP  Max of [(40 +10 x Log(Channel BW)) and 53] dBm
Spectral density at border between Norway and neighbouring countries shall not exceed -122,5 dBW/m2 measured with a reference bandwidth of 1 MHz.
5
General Notice Applicable to Europe
This equipment complies with the essential requirements for the EU R&E Directive 1999/5/EC.
The use of 5.8GHz for Point to Point radio links is not harmonized across the EU and currently the product may only be deployed in the UK, Eire (IRL), Germany, Denmark and Norway.
However, the regulatory situation in Europe is changing and the radio spectrum may become available in other countries in the near future. Please contact Motorola for the latest situation.
Regulations applicable to PTP 59600 variant
Russia
India
NOTES:
UK Registration of Links – OfCom, The application form may be found at:
http://www.ofcom.org.uk/radiocomms/isu
Eire Registration of Links – Commission for Communication Regulation, The application form
may be found at:
http://www.comreg.ie/licensing_and_services
Examples of Regulatory Limits
Operation of this product is only allowed with a License Key for Region 16 (no power limit)
Operation of this product is only allowed with a License Key for Regions 17 or 19 (36 dBm or 4W EIRP at 30 MHz, 15 MHz and 10 MHz; and 33 dBm or 2 W EIRP at 5 MHz channel bandwidth).
Disclaimer
6
The parameters quoted in this document must be specifically confirmed in writing
before they become applicable to any particular order or contract. The company
reserves the right to make alterations or amendments to the detail specification at its
discretion. The publication of information in this document does not imply freedom
from patent or other rights of Motorola, Inc. or others.
7
Contents
1 About This User Guide ....................................................................................................... 28
1.1 Interpreting Typeface and Other Conventions ...................................................................... 28
1.2 Getting Additional Help .........................................................................................................30
1.3 Sending Feedback ................................................................................................................30
2 Avoiding Hazards................................................................................................................31
2.1 Preventing Overexposure to RF Energy ............................................................................... 31
2.1.1 Calculations for Separation Distances and Power Compliance Margins..............................31
2.1.1.1 Calculated Distances and Power Compliance Margins ........................................................ 32
3 Getting Started ....................................................................................................................34
3.1 For Your Safety ..................................................................................................................... 34
3.2 Welcome ............................................................................................................................... 35
3.2.1 Who Should Use This Guide.................................................................................................35
3.2.2 Contact Information ............................................................................................................... 35
3.2.3 Repair and Service................................................................................................................ 35
3.3 Product Description............................................................................................................... 36
3.3.1 The Outdoor Unit (ODU) ....................................................................................................... 38
3.3.2 PIDU Plus – PTP 600 Series Bridge..................................................................................... 39
3.3.3 Redundancy and Alternative Powering Configurations......................................................... 41
3.3.3.1 External DC Supply Only ......................................................................................................41
3.3.3.2 External DC Supply and AC Supply...................................................................................... 42
3.3.3.3 External DC Supply and Redundant AC Supply...................................................................42
3.3.4 Remote LEDs and Recovery Switch.....................................................................................43
3.3.5 Cables and connectors ......................................................................................................... 43
3.3.6 PTP and Lightning Protection ...............................................................................................44
3.3.7 Mounting Brackets................................................................................................................. 44
3.3.8 Configuration and Management............................................................................................ 45
3.4 Warranty................................................................................................................................45
4 Product Architecture .......................................................................................................... 46
4.1 Radio Link .............................................................................................................................46
4.2 Frequency Bands .................................................................................................................. 46
4.3 Ethernet Frames.................................................................................................................... 47
4.4 Management Function .......................................................................................................... 47
4.5 Channel Bandwidth and Link Symmetry Control ..................................................................48
4.6 Upgradeable Software .......................................................................................................... 48
8
Radio Link Planning and Regulations ............................................................................. 49
5
5.1 Spectrum Planning................................................................................................................ 49
5.2 Licenses and Region Codes ................................................................................................. 50
5.2.1 PTP 25600 Licenses and Region Codes .............................................................................. 51
5.2.2 PTP 45600 Licenses and Region Codes .............................................................................. 51
5.2.3 PTP 48600 Licenses and Region Codes .............................................................................. 52
5.2.4 PTP 49600 Licenses and Region Codes .............................................................................. 53
5.2.5 PTP 54600 Licenses and Region Codes .............................................................................. 54
5.2.6 PTP 58600 Licenses and Region Codes .............................................................................. 55
5.2.7 PTP 59600 Licenses and Region Codes .............................................................................. 57
5.3 Operational Restrictions........................................................................................................58
5.3.1 Radar Avoidance................................................................................................................... 58
5.3.2 RTTT Avoidance and Other Channel Use Restrictions ........................................................59
5.3.3 Radar Avoidance, i-DFS and Variable (Narrow) Bandwidth Operation ................................ 60
5.4 Variable Channel Bandwidth Operation................................................................................60
5.5 PTP 25600 Specific Frequency Planning Considerations ....................................................60
5.5.1 Power Reduction in the Upper Band..................................................................................... 62
5.6 PTP 45600 Specific Frequency Planning Considerations ....................................................63
5.6.1 PTP 45600 Raster Considerations........................................................................................ 65
5.6.2 PTP 45600 Transmit Power Reduction at the Band Edges.................................................. 65
5.7 PTP 48600 Specific Frequency Planning Considerations ....................................................65
5.8 PTP 49600 Specific Frequency Planning Considerations ....................................................66
5.9 PTP 54600 Specific Frequency Planning Considerations ....................................................67
5.9.1 PTP 54600 Raster Considerations:....................................................................................... 69
5.9.2 Transmit Power Reduction at the Band Edges ..................................................................... 69
5.10 PTP 58600 Specific Frequency Planning Considerations ....................................................70
5.10.1 PTP 58600 Raster Considerations........................................................................................ 72
5.10.2 PTP 58600 Transmit Power Reduction at the Band Edges.................................................. 73
5.11 PTP 59600 Specific Frequency Planning Considerations ....................................................74
5.11.1 PTP 59600 Raster Considerations........................................................................................ 76
5.12 Time Division Duplex (TDD) Synchronization....................................................................... 77
5.12.1 Introduction............................................................................................................................ 77
5.12.2 TDD Synchronization ............................................................................................................78
5.12.3 Implementation of TDD Synchronization............................................................................... 79
5.12.4 System Constraints with TDD Synchronization Enabled ...................................................... 79
5.13 Color Codes ..........................................................................................................................80
9
Distance ................................................................................................................................ 80
5.14
5.15 Networking Information .........................................................................................................81
5.16 Lightning Protection............................................................................................................... 81
5.17 Electrical Requirements ........................................................................................................81
6 Site Planning........................................................................................................................ 82
6.1 Site Selection Criteria............................................................................................................ 82
6.1.1 ODU Site Selection ............................................................................................................... 82
6.1.2 PTP 600 Series Bridge PIDU Plus Site Selection.................................................................82
6.1.3 Path Loss Considerations ..................................................................................................... 83
6.1.4 Definitions.............................................................................................................................. 83
6.1.5 PTP 25600 Product Variant - Link Loss, Output Power and System Threshold versus
Modulation Mode .................................................................................................................................. 85
6.1.6 PTP 45600 Product Variant - Link Loss, Output Power and System Threshold versus
Modulation Mode .................................................................................................................................. 87
6.1.7 PTP 48600 Product Variant - Link Loss, Output Power and System Threshold versus
Modulation Mode .................................................................................................................................. 89
6.1.8 PTP 49600 Product Variant - Link Loss, Output Power and System Threshold versus
Modulation Mode .................................................................................................................................. 91
6.1.9 PTP 54600 Product Variant - Link Loss, Output Power and System Thresholds versus
Modulation Mode .................................................................................................................................. 93
6.1.10 PTP 58600 Product Variant - Link Loss, Output Power and System Thresholds versus
Modulation Mode .................................................................................................................................. 95
6.1.11 PTP 59600 Product Variant - Link Loss, Output Power and System Thresholds versus
Modulation Mode .................................................................................................................................. 97
7 Installation ...........................................................................................................................99
7.1 Preparation............................................................................................................................99
7.2 Installation Procedure ........................................................................................................... 99
7.3 Tools Required .................................................................................................................... 100
7.4 Installation Support.............................................................................................................. 100
7.5 Legal Disclaimer.................................................................................................................. 100
7.6 Mounting the ODUs............................................................................................................. 101
7.7 Connecting Up..................................................................................................................... 103
7.7.1 Preparing the PIDU Plus To ODU Cable ............................................................................103
7.7.2 Making the Connections at the ODU................................................................................... 106
7.7.3 Making the PTP 600 Series Bridge PIDU Plus Connection At The ODU ........................... 107
7.7.4 Routing the Cable................................................................................................................ 108
7.7.5 Fitting a Lightning Protection Unit ....................................................................................... 108
7.7.6 Grounding the Installation ................................................................................................... 109
10
Making the ODU Connection at the PTP 600 Series Bridge PIDU Plus............................. 109
7.7.7
7.7.8 Making the Network Connection at The PIDU Plus – PTP 600 Series Bridge ................... 110
7.7.9 Mounting the PTP 600 Series Bridge PIDU Plus ................................................................ 111
7.7.10 Powering Up........................................................................................................................ 113
7.7.11 Aligning the PTP 600 Series Bridge ODUs.........................................................................114
8 Web Page Reference......................................................................................................... 117
8.1 Home Page – PTP 600 Series Bridge................................................................................. 119
8.1.1 Home Page Alarm Display .................................................................................................. 120
8.2 Systems Status Page.......................................................................................................... 124
8.2.1 Histogram Data ...................................................................................................................129
8.3 System Administration Pages ............................................................................................. 130
8.3.1 System Configuration..........................................................................................................131
8.3.1.1 General Configuration Page................................................................................................131
8.3.1.2 LAN Configuration Page .....................................................................................................133
8.3.1.3 LAN Configuration Page – Use VLAN For Management Interfaces...................................136
8.3.1.4 LAN Configuration Page – Manual Ethernet Configuration ................................................ 137
8.3.1.5 Save and Restore Configuration File .................................................................................. 138
8.3.1.5.1 Save Configuration File....................................................................................................... 138
8.3.1.5.2 Restore Configuration File .................................................................................................. 140
8.3.1.6 Telecoms Configuration Page............................................................................................. 142
8.3.2 Statistics Page..................................................................................................................... 144
8.3.3 Detailed Counters Page ...................................................................................................... 147
8.3.4 Install Pages........................................................................................................................150
8.3.4.1 Manually Configuring The Wireless Units...........................................................................151
8.3.4.2 Internet Protocol Configuration ...........................................................................................153
8.3.4.3 Telecoms Interface.............................................................................................................. 155
8.3.4.4 Wireless Configuration ........................................................................................................ 156
8.3.4.5 Confirm Configuration ......................................................................................................... 163
8.3.4.6 Disarm.................................................................................................................................165
8.3.5 Graphical Install................................................................................................................... 167
8.3.6 Software Upgrade ...............................................................................................................168
8.3.7 Spectrum Management.......................................................................................................172
8.3.7.1 Wireless Channels .............................................................................................................. 172
8.3.7.2 Spectrum Management Measurements..............................................................................172
8.3.7.3 Measurement Analysis........................................................................................................ 172
8.3.7.4 The Spectrum Management Master / Slave Relationship...................................................173
11
8.3.7.5
8.3.7.6 Barring Channels.................................................................................................................177
8.3.7.7 Master and Slave Channel Spectrum Graphics.................................................................. 177
8.3.7.8 Active Channel History........................................................................................................179
8.3.7.9 Viewing Historic Spectrum Management Metrics ...............................................................180
8.3.8 Spectrum Management (Fixed Frequency) ........................................................................ 181
8.3.9 Spectrum Management Control - With Operational Restrictions ........................................ 182
8.3.10 Spectrum Management – Example of PTP 25600 Product variant .................................... 185
8.3.11 Remote Management Page ................................................................................................ 186
8.3.11.1 Control Access to HTTP Interface....................................................................................... 187
8.3.11.2 Control Access to Telnet Interface ...................................................................................... 187
8.3.11.3 SNMP (Simple Network Management Protocol)................................................................. 187
8.3.11.4 Supported Management Information Bases (MIBS) ........................................................... 187
8.3.11.5 Diagnostics Alarms.............................................................................................................. 189
8.3.11.6 SNMP Configuration............................................................................................................ 190
8.3.11.7 SMTP (Simple Mail Transport Protocol).............................................................................. 190
8.3.11.8 SNTP (Simple Network Time Protocol)...............................................................................191
Spectrum Management Configuration ................................................................................ 176
8.3.11.9 Setting the clock .................................................................................................................. 191
8.3.12 Diagnostics..........................................................................................................................192
8.3.12.1 Diagnostic Plotter ................................................................................................................ 193
8.3.12.2 Diagnostics Download.........................................................................................................194
8.3.13 Change System Administration Password..........................................................................195
8.3.14 License Key.........................................................................................................................195
8.3.15 Properties ............................................................................................................................ 197
8.3.16 Reboot.................................................................................................................................198
9 Recovery Mode..................................................................................................................199
9.1 Upgrade Software Image .................................................................................................... 201
9.2 Reset IP & Ethernet Configuration ...................................................................................... 203
9.3 Erase Configuration............................................................................................................. 204
9.4 Reboot.................................................................................................................................207
10 Lightning Protection ......................................................................................................... 208
10.1 Overview ............................................................................................................................. 208
10.1.1 Lightning Protection Zones .................................................................................................208
10.2 Detailed Installation.............................................................................................................211
10.3 Installation Wiring................................................................................................................214
10.4 LPU Recommended Configurations.................................................................................... 215
12
Typical Mast or Tower Installation....................................................................................... 216
10.4.1
10.4.2 Typical Wall Installation....................................................................................................... 217
10.4.3 Mast or Tower Installation with E1/T1 ................................................................................. 218
10.4.4 Wall Installation with E1/T1 ................................................................................................. 219
10.4.5 Mast or Tower Installation with GPS Sync Box................................................................... 220
10.4.6 Wall Installation with GPS Sync Box................................................................................... 221
10.4.7 Mast or Tower Installation with GPS Sync Box and E1/T1................................................. 222
10.4.8 Wall Installation with GPS Sync Box and E1/T1 ................................................................. 223
11 Troubleshooting (Fault Finding)......................................................................................224
11.1 Test Link End Hardware...................................................................................................... 224
11.1.1 Power LED is Off................................................................................................................. 226
11.1.2 Power LED is Flashing........................................................................................................227
11.1.3 Ethernet LED did not Flash 10 Times ................................................................................. 227
11.1.4 No Ethernet Activity............................................................................................................. 228
11.1.5 Irregular Ethernet Activity....................................................................................................229
11.1.6 Connection is not 1000 BaseT ............................................................................................ 229
11.1.7 Test RJ45 Resistance ......................................................................................................... 229
11.2 Test Radio Link ...................................................................................................................231
11.2.1 No Activity ...........................................................................................................................231
11.2.2 Some Activity....................................................................................................................... 231
12 Wind Loading..................................................................................................................... 232
12.1 General................................................................................................................................ 232
12.2 Calculation of Lateral Force ................................................................................................ 232
12.3 Capabilities of the PTP 600 Series Bridges ........................................................................ 233
12.4 Wind Speed Statistics .........................................................................................................233
13 Connectorized PTP 600 Series Bridge............................................................................234
13.1 Scope .................................................................................................................................. 234
13.2 Product Description............................................................................................................. 234
13.2.1 Hardware.............................................................................................................................234
13.2.2 Antenna ............................................................................................................................... 234
13.3 Software/Features ............................................................................................................... 235
13.3.1 Status Page.........................................................................................................................235
13.3.2 Configuration Pages............................................................................................................ 236
13.3.3 Installation Pages................................................................................................................ 237
13.4 Deployment Considerations ................................................................................................ 240
13.5 Link Budget .........................................................................................................................240
13
Regulatory Issues with Connectorized Units ...................................................................... 240
13.6
13.6.1 Cable Losses (FCC Regions Only).................................................................................... 241
13.6.2 Antenna Choices.................................................................................................................241
13.6.3 FCC Antenna Restrictions on the PTP 58600 ....................................................................242
13.6.4 FCC Antenna Restrictions on the PTP 54600 ....................................................................246
13.7 Installation ........................................................................................................................... 249
13.7.1 Antenna Choice................................................................................................................... 249
13.7.2 Cables and Connectors....................................................................................................... 249
13.7.3 Tools.................................................................................................................................... 249
13.7.4 Miscellaneous supplies .......................................................................................................250
13.7.5 Mounting the Connectorized 600 Series Bridge .................................................................250
13.7.6 Mounting the antennas........................................................................................................ 250
13.7.7 Alignment Process ..............................................................................................................251
13.7.8 Aligning Dual Polar Antennas ............................................................................................. 251
13.7.9 Aligning Separate Antennas................................................................................................ 251
13.7.10 Completing the Installation..................................................................................................252
13.7.11 Antenna Cable Fixing..........................................................................................................252
13.7.12 Antenna Connection Weatherproofing................................................................................ 253
13.8 Additional Lightning Protection............................................................................................ 254
13.8.1 ODU Mounted Outdoors ..................................................................................................... 254
13.8.2 ODU Mounted Indoors ........................................................................................................ 255
14 TDD Synchronization Configuration and Installation Guide ........................................ 256
14.1 Introduction.......................................................................................................................... 256
14.1.1 Installing the Recommended GPS Synchronization Kit...................................................... 257
14.2 TDD Synchronization Configuration.................................................................................... 261
14.2.1 TDD Synchronization Enable .............................................................................................. 261
14.2.2 TDD Synchronization Configuration - Standard Mode........................................................262
14.2.3 TDD Synchronization Configuration – Expert Mode ........................................................... 265
14.2.4 Confirm Settings and Reboot ODU ..................................................................................... 266
14.2.5 Disarm ODU Following TDD Sync Configuration................................................................ 268
15 E1/T1 Installation Guide ...................................................................................................269
15.1 Preparing the PTP 600 Series Bridge E1/T1 Cable............................................................269
15.2 Making the Connection at the ODU ....................................................................................270
15.3 Routing the Cable................................................................................................................ 272
15.4 Fitting a Lightning Protection Unit ....................................................................................... 272
15.5 Customer Cable Termination .............................................................................................. 272
14
Lightning Protection and E1/T1...........................................................................................275
15.6
15.6.1 Overview ............................................................................................................................. 275
15.6.2 Recommended Additional Components for E1/T1 Installation. .......................................... 275
15.7 Testing the E1/T1 Installation.............................................................................................. 276
15.7.1 Pre-Power Testing............................................................................................................... 276
16 Data Rate Calculations .....................................................................................................277
16.1 Calculation Procedure and Example................................................................................... 277
16.1.1 Procedure............................................................................................................................ 277
16.1.2 Example ..............................................................................................................................278
16.2 Data Throughput Capacity .................................................................................................. 279
16.3 Range Adjustment Curves .................................................................................................. 284
17 AES Encryption Upgrade .................................................................................................298
17.1 Configuring Link Encryption ................................................................................................ 298
17.1.1 License Keys ....................................................................................................................... 298
17.1.2 Encryption Mode and Key ................................................................................................... 300
17.2 Wireless Link Encryption FAQ ............................................................................................302
17.2.1 Encryption data entry fields are not available .....................................................................302
17.2.2 Link fails to bridge packets after enabling link encryption................................................... 302
17.2.3 Loss of AES following downgrade....................................................................................... 302
18 Remote Software Upgrade by TFTP ................................................................................ 303
19 Legal and Regulatory Notices.......................................................................................... 305
19.1 Important Note on Modifications .........................................................................................305
19.2 National and Regional Regulatory Notices – PTP 49600 variant ....................................... 305
19.3 National and Regional Regulatory Notices – PTP 59600 variant ....................................... 305
19.3.1 Russia ................................................................................................................................. 305
19.4 National and Regional Regulatory Notices – PTP 58600 variant ....................................... 306
19.4.1 U.S. Federal Communication Commission (FCC) and Industry Canada (IC) Notification.. 306
19.4.2 European Union Notification ...............................................................................................307
19.4.3 UK Notification..................................................................................................................... 308
19.5 National and Regional Regulatory Notices – PTP 54600 Variant....................................... 309
19.5.1 U.S. Federal Communication Commission (FCC) and Industry Canada (IC) Notification.. 309
19.5.2 European Union Notification ...............................................................................................310
19.6 National and Regional Regulatory Notices – PTP 25600 Variant....................................... 311
19.6.1 U.S. Federal Communication Commission (FCC) Notification ........................................... 311
19.7 Exposure ............................................................................................................................. 311
19.8 Legal Notices....................................................................................................................... 312
15
Motorola Inc. End User License Agreement .......................................................................312
19.8.1
19.8.1.1 Definitions............................................................................................................................ 312
19.8.1.2 Grant of License .................................................................................................................. 312
19.8.1.3 Conditions of Use ................................................................................................................ 313
19.8.1.4 Title; Restrictions.................................................................................................................314
19.8.1.5 Confidentiality......................................................................................................................314
19.8.1.6 Right to Use Motorola’s Name ............................................................................................315
19.8.1.7 Transfer ............................................................................................................................... 315
19.8.1.8 Updates ............................................................................................................................... 315
19.8.1.9 Maintenance........................................................................................................................315
19.8.1.10 Disclaimer............................................................................................................................316
19.8.1.11 Limitation of Liability............................................................................................................ 316
19.8.1.12 U.S. Government.................................................................................................................317
19.8.1.13 Term of License...................................................................................................................317
19.8.1.14 Governing Law .................................................................................................................... 317
19.8.1.15 Assignment..........................................................................................................................317
19.8.1.16 Survival of Provisions.......................................................................................................... 318
19.8.1.17 Entire Agreement ................................................................................................................ 318
19.8.1.18 Third Party Software............................................................................................................318
19.8.2 Hardware Warranty in U.S. ................................................................................................. 320
19.8.3 Limit of Liability.................................................................................................................... 321
20 Specifications .................................................................................................................... 322
20.1 System Specifications ......................................................................................................... 322
20.1.1 Wireless PTP 25600 Variant ............................................................................................... 322
20.1.2 Wireless PTP 45600 Variant ............................................................................................... 323
20.1.3 Wireless PTP 48600 Variant ............................................................................................... 324
20.1.4 Wireless PTP 49600 Variant ............................................................................................... 325
20.1.5 Wireless PTP 54600 Variant ............................................................................................... 326
20.1.6 Wireless PTP 58600 Variant ............................................................................................... 327
20.1.7 Wireless PTP 59600 Variant ............................................................................................... 328
20.1.8 Management .......................................................................................................................329
20.1.9 Ethernet Bridging................................................................................................................. 329
20.1.10 Physical ............................................................................................................................... 330
20.1.11 Powering .............................................................................................................................330
20.1.12 Telecoms Interface.............................................................................................................. 330
20.2 Safety Compliance .............................................................................................................. 331
16
EMC Emissions Compliance...............................................................................................331
20.3
20.3.1 PTP 25600 Variant..............................................................................................................331
20.3.2 PTP 45600 Variant..............................................................................................................331
20.3.3 PTP 48600 Variant..............................................................................................................331
20.3.4 PTP 49600 Variant..............................................................................................................331
20.3.5 PTP 54600 Variant..............................................................................................................332
20.3.6 PTP 58600 Variant..............................................................................................................332
20.4 EMC Immunity Compliance................................................................................................. 333
20.5 Radio Certifications ............................................................................................................. 334
20.5.1 PTP 25600 Variant..............................................................................................................334
20.5.2 PTP 45600 Variant..............................................................................................................334
20.5.3 PTP 48600 Variant..............................................................................................................334
20.5.4 PTP 49600 Variant..............................................................................................................334
20.5.5 PTP 54600 Variant..............................................................................................................334
20.5.6 PTP 58600 Variant..............................................................................................................335
20.6 Environmental Specifications .............................................................................................. 336
20.7 System Connections ...........................................................................................................336
20.7.1 PIDU Plus to ODU and ODU to Network Equipment Connections..................................... 336
21 FAQs...................................................................................................................................338
22 Glossary ............................................................................................................................. 340
23 Index ................................................................................................................................... 341
17
List of Figures
Figure 1 - Typical PTP 600 Series Bridge Deployment........................................................................36
Figure 2 - Mod Record Label................................................................................................................37
Figure 3 – PTP 600 Series Bridge Outdoor Unit (ODU) with PTP-LPU ............................................... 38
Figure 4 - Power Indoor Unit (PIDU Plus) – PTP 300/500/600 Series.................................................39
Figure 5 – PIDU Plus Recovery Switch Location ................................................................................. 39
Figure 6 –PTP 300/500/600 Series Bridge PIDU Plus Power Input..................................................... 40
Figure 7 – PTP 600 Series Bridge PIDU Plus to ODU Cable Length Graph .......................................41
Figure 8 - External DC Supply Only .....................................................................................................41
Figure 9 - External DC Supply and AC Supply.....................................................................................42
Figure 10 - External DC Supply and Redundant AC Supply................................................................42
Figure 11 - Remote LED and Recovery Switch Wiring ........................................................................43
Figure 12 – PTP 600 Series Bridge Layer Diagram ............................................................................. 47
Figure 13 - 5.8 GHz UK RTTT Channel Avoidance – 30 MHz Channel Bandwidth (Example)...........59
Figure 14 - 2.5 GHz BRS Band Channel Assignments........................................................................62
Figure 15 - 4.5 GHz Available Spectrum Settings – 30 MHz Channel Bandwidth...............................63
Figure 16 - 4.5 GHz Available Spectrum Settings – 15 MHz Channel Bandwidth...............................64
Figure 17 - 4.5 GHz Available Spectrum Settings – 10 MHz Channel Bandwidth...............................64
Figure 18 - 4.5 GHz Available Spectrum Settings – 5 MHz Channel Bandwidth.................................65
Figure 19 - 4.9 GHz Available Spectrum Settings - 20 MHz Channel Bandwidth................................ 66
Figure 20 - 4.9 GHz Available Spectrum Settings - 10 MHz Channel Bandwidth................................ 66
Figure 21 - 4.9 GHz Available Spectrum Settings - 5 MHz Channel Bandwidth.................................. 67
Figure 22 - 5.4 GHz Available Spectrum Settings - 30 MHz Channel Bandwidth................................ 67
Figure 23 - 5.4 GHz Available Spectrum Settings - 15 MHz Channel Bandwidth................................ 68
Figure 24 - 5.4 GHz Available Spectrum Settings - 10 MHz Channel Bandwidth................................ 68
Figure 25 - 5.4 GHz Available Spectrum Settings - 5 MHz Channel Bandwidth.................................. 68
Figure 26 - 5.8 GHz Available Spectrum Settings – 30 MHz Channel Bandwidth...............................70
18
Figure 27 - 5.8 GHz Available Spectrum Settings - 15 MHz Channel Bandwi
Figure 28 - 5.8 GHz Available Spectrum Settings - 10 MHz Channel Bandwidth................................ 71
Figure 29 - 5.8 GHz Available Spectrum Settings - 5 MHz Channel Bandwidth.................................. 71
Figure 30 - 5.9 GHz Available Spectrum Settings – 30 MHz Channel Bandwidth...............................74
Figure 31 - 5.9 GHz Available Spectrum Settings - 15 MHz Channel Bandwidth................................ 75
Figure 32 - 5.9 GHz Available Spectrum Settings - 10 MHz Channel Bandwidth................................ 75
Figure 33 - 5.9 GHz Available Spectrum Settings - 5 MHz Channel Bandwidth.................................. 76
Figure 34 - Co-location of Links Interference Problem - A Simple Example ........................................ 77
Figure 35 TDD Synchronization And Co location Example.................................................................. 78
Figure 36 - Mounting to pole diameters 25mm (1”) to 50mm (2”) ...................................................... 101
Figure 37 - Integral Safety Loop ......................................................................................................... 102
Figure 38 - Correct Cable Preparation for the Recommended Cable ................................................ 104
Figure 39 - Completed ODU Connector ............................................................................................. 105
dth................................ 71
Figure 40 - Correct and Incorrect Tightening of Cable Gland ............................................................105
Figure 41 – PTP 600 Series Bridge PIDU Plus Connexion................................................................ 106
Figure 42 - Connecting the PIDU+ to the ODU .................................................................................. 107
Figure 43 - Disconnecting the ODU.................................................................................................... 108
Figure 44 - Making the Network Connection at the PIDU Plus ..........................................................110
Figure 45 – PTP 600 Series PIDU Plus Drip Loop Configuration ...................................................... 112
Figure 46 - Menu Navigation Bar........................................................................................................ 118
Figure 47 - System Summary Page ................................................................................................... 119
Figure 48 - Alarm Warning Triangle ...................................................................................................120
Figure 49 - Status Page...................................................................................................................... 124
Figure 50 - System Administration Login Page .................................................................................. 130
Figure 51 - System Configuration Page ............................................................................................. 131
Figure 52 - LAN Configuration Page .................................................................................................. 133
Figure 53 - Configuration Reboot Page.............................................................................................. 135
19
Figure 54 - Configuration Reboot Page
Figure 55 - VLAN Configuration Fields............................................................................................... 136
Figure 56 - LAN Configuration Page - Manual Ethernet Configuration.............................................. 137
Figure 57 - Save and Restore Configuration Page ............................................................................138
Figure 58 - Save Configuration File Screen .......................................................................................139
Figure 59 – PTP 600 Example Configuration File .............................................................................. 139
Figure 60 - Restore Configuration File Pop Up Screen...................................................................... 140
Figure 61 - Reset Configuration and Reboot Confirmation Pop-up ...................................................141
Figure 62 - Telecoms Data Entry........................................................................................................ 142
Figure 63 - System Statistics.............................................................................................................. 144
Figure 64 - Detailed Counters Page...................................................................................................147
Figure 65 - License Key Data Entry.................................................................................................... 152
Figure 66 - Installation Wizard Internet Protocol Configuration.......................................................... 153
- Ethernet Auto Negotiation Disabled.................................. 135
Figure 67 - VLAN Warning .................................................................................................................154
Figure 68 - Telecoms Configuration Interface .................................................................................... 155
Figure 69 –Wireless Configuration ..................................................................................................... 156
Figure 70 – Fixed Frequency Configuration Example ........................................................................ 162
Figure 71 – Installation Wizard Confirm Configuration....................................................................... 163
Figure 72 - Reboot Confirmation Pop Up ........................................................................................... 164
Figure 73 – Disarm Installation...........................................................................................................165
Figure 74 - Optional Post Disarm Configuration 1.............................................................................. 166
Figure 75 - Optional Post Disarm Configuration 2.............................................................................. 166
Figure 76 – Graphical Installation Screen .......................................................................................... 167
Figure 77 - Software Upgrade ............................................................................................................ 168
Figure 78 - Software Upgrade Image Check......................................................................................169
Figure 79 - Software Download Progress Indicator............................................................................ 170
Figure 80 - Software Upgrade Complete............................................................................................ 170
20
Figure 81 - Reboot Confirmation Pop Up
Figure 82 - Spectrum Management as seen from the Master............................................................ 174
Figure 83 - Spectrum Management as seen from the Slave.............................................................. 175
Figure 84 - Example Spectrum Management Graphic ....................................................................... 177
Figure 85 - Active Channel History Screen ........................................................................................ 179
Figure 86 - Spectrum Management Time Series Plot ........................................................................ 180
Figure 87 - Spectrum Management Fixed Frequency Screen ........................................................... 181
Figure 88 - Spectrum Management Help Page (Fixed Frequency) ...................................................182
Figure 89 - Spectrum Management Master Screen With Operational Restrictions ........................... 183
Figure 90 - Spectrum Management Slave Screen With Operational Restrictions ............................. 184
Figure 91 - PTP 25600 Example of Spectrum Management Page .................................................... 185
Figure 92 - Remote Management....................................................................................................... 186
Figure 93 – Warning when disabling HTTP interface.........................................................................188
........................................................................................... 171
Figure 94 - Remote Management - Diagnostic Alarms ...................................................................... 189
Figure 95 - Diagnostic Plotter .............................................................................................................193
Figure 96 - CSV Download.................................................................................................................194
Figure 97 - Password Change............................................................................................................195
Figure 98 - Software License Key Data Entry .................................................................................... 195
Figure 99: License Key reboot Screen ............................................................................................... 196
Figure 100 - Reboot Confirmation Pop Up ......................................................................................... 196
Figure 101 – Properties ...................................................................................................................... 197
Figure 102 - System Reboot............................................................................................................... 198
Figure 103 - Reboot Confirmation Pop Up ......................................................................................... 198
Figure 104 - Recovery Mode Warning Page ...................................................................................... 199
Figure 105 - Recovery Options Page ................................................................................................. 200
Figure 106 - Software Download Progress Indicator Page ................................................................ 201
Figure 107 - Software Download Complete Page .............................................................................. 201
21
Figure 108 - Reboot Confirmation Pop Up
Figure 109 - Confirm Reset to Factory Default Pop Up...................................................................... 203
Figure 110 - IP and Ethernet Erased Successfully page.................................................................... 203
Figure 111 - Reboot Confirmation Pop Up ......................................................................................... 204
Figure 112 - Confirm Erase Configuration Pop Up............................................................................. 204
Figure 113 - Erase Configuration Successful Page ...........................................................................205
Figure 114 – Erase Configuration - Reboot Confirmation Pop Up ..................................................... 206
Figure 115 – Recovery - Reboot Confirmation Pop Up...................................................................... 207
Figure 116 - ODU mounted in Zones A & B ....................................................................................... 209
Figure 117 - Showing how the use of a Finial enables the ODU to be mounted inside Zone B ........ 210
Figure 118 – Example of PTP-LPU Configuration – Option 1 (Back-to-Back Recommended) .........211
Figure 119 - PTP-LPU - Installation Option 2 (Using U-Bolt) ............................................................. 212
Figure 120 - PTP LPU Full Kit ............................................................................................................ 213
......................................................................................... 202
Figure 121 - Simplified Circuit Diagram.............................................................................................. 214
Figure 170 - Typical Mast or Tower Installation .................................................................................216
Figure 171 - Typical Wall Installation.................................................................................................. 217
Figure 172 – Mast or Tower Installation with E1/T1 ........................................................................... 218
Figure 173 - Wall Installation with E1/T1............................................................................................219
Figure 174 – Mast or Tower Installation with GPS Sync Box............................................................. 220
Figure 175 –Wall Installation with GPS Sync Box..............................................................................221
Figure 176 - Mast or Tower Installation with GPS Sync Box and E1/T1............................................222
Figure 177 - Wall Installation with GPS Sync Box and E1/T1............................................................223
Figure 122 – Link End Hardware Test Flowchart ............................................................................... 225
Figure 123 - PTP LPU Test Points ..................................................................................................... 228
Figure 124 – Connectorized 600 Series Bridge Outdoor Unit............................................................234
Figure 125 - Connectorized 600 Series bridge Status Page..............................................................235
Figure 126 - Connectorized 600 Series bridge ‘System Configuration’ Page....................................236
22
Figure 127 - Connectorized PTP 600 Series Bridge ‘Installation Wi
Figure 128 - Connectorized 600 Series bridge ‘Confirm Installation’ Page........................................238
Figure 129 - Connectorized 600 Series bridge ‘Disarm Installation’ Page......................................... 239
Figure 130 - Forming a Drip Loop ...................................................................................................... 253
Figure 131 - Weatherproofing the Antenna Connections...................................................................253
Figure 132- Additional Grounding When Using Connectorized Units ................................................ 254
Figure 133 - Lightning Arrestor Mounting...........................................................................................255
Figure 134 - Polyphaser Assembly.....................................................................................................255
Figure 135 - GPS Synchronization Unit..............................................................................................257
Figure 136 - GPS Synchronization Unit Connections ........................................................................258
Figure 137 - TDD Sync - PTP600 Deployment Diagram.................................................................... 259
Figure 138- GPS Synchronization Unit Complete Installation............................................................ 260
Figure 139 - Enabling TDD Synchronization Feature......................................................................... 261
zard’ Page ................................ 237
Figure 140 - Configuring TDD Synchronization – Screen 1 ............................................................... 262
Figure 141 - Configuring TDD Synchronization Feature - Screen 2 ..................................................264
Figure 142 - Configure TDD Synchronisation Expert Mode...............................................................265
Figure 143 - Confirm TDD Synchronization Configuration Parameters ............................................. 266
Figure 144 - Status Page - TDD Enabled and Synchronized............................................................. 267
Figure 145 - Status Page - TDD Enabled and Not Synchronized ..................................................... 267
Figure 146 - Disarm Following TDD Synchronization ........................................................................268
Figure 147 - RJ45 Pin Connection (T568B Color Coding) ................................................................. 269
Figure 148 - PIDU Plus and E1-T1 Connexion ..................................................................................270
Figure 149 - Disconnecting the ODU..................................................................................................271
Figure 150 - Example of a Balun ........................................................................................................272
Figure 151 - Diagrammatically Showing the E1-T1 Connections....................................................... 273
Figure 152 - Two E1-T1-120 Ohms signal Balanced to PTP600 Interface........................................274
Figure 153 – PTP 600 Range Adjustment for Data Rates, Curve A ..................................................285
23
Figure 154 – PTP 600 Range Adjustment for Data Rat
Figure 155 – PTP 600 Range Adjustment for Data Rates, Curve C .................................................. 287
Figure 156 – PTP 600 Range Adjustment for Data Rates, Curve D .................................................. 288
Figure 157 – PTP 600 Range Adjustment for Data Rates, Curve E ..................................................289
Figure 158 – PTP 600 Range Adjustment for Data Rates, Curve F ..................................................290
Figure 159 – PTP 600 Range Adjustment for Data Rates, Curve G..................................................291
Figure 160 – PTP 600 Range Adjustment for Data Rates, Curve H .................................................. 292
Figure 161 – PTP 600 Range Adjustment for Data Rates, Curve I.................................................... 293
Figure 162 – PTP 600 Range Adjustment for Data Rates, Curve J...................................................294
Figure 163 – PTP 600 Range Adjustment for Data Rates, Curve K ..................................................295
Figure 164 – PTP 600 Range Adjustment for Data Rates, Curve L................................................... 296
Figure 165 – PTP 600 Range Adjustment for Data Rates, Curve M.................................................. 297
Figure 166 – AES Software License Key Data Entry ......................................................................... 299
es, Curve B .................................................. 286
Figure 167 – AES Configuration Data Entry Page ............................................................................. 300
Figure 168 - Configuration Reboot Screen......................................................................................... 301
Figure 169 - Cable Connection Diagram (T568B Color Coding)........................................................ 336
24
List of Tables
Table 1 - Font types............................................................................................................................28
Table 2 - Admonition types...................................................................................................................29
Table 3 - Power Compliance Margins ..................................................................................................32
Table 4 - Contact Information ............................................................................................................... 35
Table 5 - PTP 600 Series Bridge Frequency Variants .........................................................................49
Table 6 – PTP 25600 Licenses and Region Codes .............................................................................51
Table 7 – PTP 45600 Licenses and Region Codes .............................................................................51
Table 8 – PTP 48600 Licenses and Region Codes .............................................................................52
Table 9 – PTP 49600 Licenses and Region Codes .............................................................................53
Table 10 – PTP 54600 Licenses and Region Codes ...........................................................................54
Table 11 – PTP 58600 Licenses and Region Codes ...........................................................................55
Table 12 – PTP 59600 Licenses and Region Codes ...........................................................................57
Table 13 - PTP 25600 Product Variant Channel Plan - FCC BRS-EBS Post-Transition Band ...........61
Table 14 - Power Reduction in the Upper Band...................................................................................62
Table 15 – PTP 48600 Channel Center Frequencies ..........................................................................65
Table 16 – PTP 58600 Band Edge Tx Power Reduction ..................................................................... 73
Table 17 - PTP 25600 - IP Mode – Loss, Output Power and System Threshold Vs Modulation Mode
....................................................................................................................................................... 85
Table 18 - PTP 25600 - TDM Mode – Loss, Output Power and System Threshold Vs Modulation
Mode.............................................................................................................................................. 86
Table 19 - PTP 45600 - IP Mode – Loss, Output Power and System Threshold Vs Modulation Mode
....................................................................................................................................................... 87
Table 20 - PTP 45600 - TDM Mode – Loss, Output Power and System Threshold Vs Modulation
Mode.............................................................................................................................................. 88
Table 21 - PTP 48600 - IP Mode – Loss, Output Power and System Threshold Vs Modulation Mode
....................................................................................................................................................... 89
Table 22 - PTP 48600 - TDM Mode – Loss, Output Power and System Threshold Vs Modulation
Mode.............................................................................................................................................. 90
25
Table 23 - PTP 49600 - IP Mode – Loss, Output P
....................................................................................................................................................... 91
Table 24 - PTP 49600 - TDM Mode – Loss, Output Power and System Threshold Vs Modulation
Mode.............................................................................................................................................. 92
Table 25 – PTP 54600 - IP Mode - Link Loss, Output Power, System Threshold Vs Modulation Mode
....................................................................................................................................................... 93
Table 26 – PTP 54600 - TDM Mode - Link Loss, Output Power, System Threshold Vs Modulation
Mode.............................................................................................................................................. 94
Table 27 - PTP 58600 - IP Mode - Link Loss, Output Power, System Threshold Vs Modulation Mode
....................................................................................................................................................... 95
Table 28 - PTP 58600 - TDM Mode - Link Loss, Output Power, System Threshold Vs Modulation
Mode.............................................................................................................................................. 96
Table 29 - PTP 59600 - IP Mode - Link Loss, Output Power, System Threshold Vs Modulation Mode
....................................................................................................................................................... 97
Table 30 - PTP 59600 - TDM Mode - Link Loss, Output Power, System Threshold Vs Modulation
Mode.............................................................................................................................................. 98
Table 31 - Audio indications from the ODU........................................................................................114
ower and System Threshold Vs Modulation Mode
Table 32 – 600 Series Bridge Factory Configuration Values .............................................................150
Table 33 – TDD Structure in TDM Mode............................................................................................158
Table 34 - Spectrum Management change state key......................................................................... 178
Table 35 - Spectrum Management Time Series Key .........................................................................180
Table 36 - Spectrum Management Change State Key With Operational Restrictions....................... 184
Table 37 - Protection Requirements................................................................................................... 210
Table 38 - Resistance Table Referenced To The RJ45 at the PIDU+ ............................................... 230
Table 39 - Lateral Force – Imperial ....................................................................................................232
Table 40 - Lateral Force – Metric .......................................................................................................232
Table 41 - Cable Losses per Length .................................................................................................. 241
Table 42 - Allowed Antennas for Deployment in USA/Canada – 5.8 GHz......................................... 242
Table 43 - Allowed Antennas for Deployment in USA/Canada – 5.4 GHz......................................... 246
Table 44 - Common Burst Durations .................................................................................................. 263
Table 45 - Protection Requirements................................................................................................... 275
26
Table 46 - Resistance Table Referenc
Table 47 – Data Throughput for PTP 600 Full, Link Symmetry = 1:1, Link Optimization = IP........... 280
Table 48 – Data Throughput for PTP 600 Full, Link Symmetry = 1:1, Link Optimization = TDM.......281
Table 49 – Data Throughput for PTP 600 Full, Link Symmetry = 2:1, Link Optimization = IP........... 282
Table 50 – Data Throughput for PTP 600 Full, Link Symmetry = 2:1, Link Optimization = TDM.......282
Table 51 – Data Throughput for PTP 600 Full, Link Symmetry = Adaptive Link Optimization = IP... 283
Table 52 – Range Adjustment Characteristics ................................................................................... 284
Table 53 - Telecoms Connection Pin Out........................................................................................... 337
ed To the E1/T1 Source ........................................................ 276
List of Equations
Equation 1 - Peak power density in the far field ................................................................................... 32
Equation 2 - Path Loss ......................................................................................................................... 83
Equation 3 - Link Loss ........................................................................................................................ 127
27
1 About This User Guide
1 About This User Guide
This guide covers the installation, commissioning, operation and fault finding of the Motorola
PTP 600 Series of Point-to-Point Wireless Ethernet Bridges.
1.1 Interpreting Typeface and Other Conventions
This document employs distinctive fonts to indicate the type of information, as described in
Table 1.
Table 1 - Font types
Font Type of Information
variable width bold
constant width regular
constant width italic
constant width bold
constant width bold italic
This document employs specific imperative terminology as follows:
x Type means press the following characters.
x Enter means type the following characters and then press Enter.
x Highlight means click anywhere in a row of data to highlight the entire row.
x Select means use the mouse to click on or branch to the menu item that follows.
Use this table and the Glossary to aid in interpreting the technical acronyms used throughout
this User Guide.
Selectable option in a graphical user interface or settable parameter in a web-based interface.
Literal system response in a command-line interface.
Variable system response in a command-line interface.
Literal user input in a command-line interface.
Variable user input in a command-line interface.
28
Loading...
+ 314 hidden pages