Cables to Go TE100-S55 User Manual

Page 1
ProXpressTM
Multifunction Switch/Router
Model TE100-S55
for connecting 10Base-T, 100Base-TX,
100Base-FX and ISDN links
User’s Guide
First Edition - June 1, 1996
Page 2
Trademarks
Copyright 1996 TRENDware All rights reserved, contents may be revised without prior notice. TRENDnet is a registered trademark of TRENDware
Ethernet is a trademark of Xerox Corporation.
Microsoft Windows is a trademark of Microsoft Corporation.
VT100 is a trademark of Digital Equipment Corporation.
FCC warning
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user may be required to correct the interference at his or her own expense.
2
Page 3
Service and support
TRENDware is committed to providing customers with high quality and timely technical support worldwide.
Unlimited technical support is available to you free of charge. TRENDware support engineers are available to respond to your calls Monday through Friday, 8:30 a.m. to 5:30 p.m. Pacific Standard Time.
USA
TEL
1-310-328-7795
Bulletin Board System:
310-328-8191
(protocol: 14400, 8, N,1)
World Wide Web Site:
http://www.trendware.com
FAX
1-310-328-7798
3
Page 4
About this manual
This manual is the user’s reference guide for the TE100-S55 that interconnects Fast Ethernet, 10Base-T and ISDN links into a single system. It provides detailed information on the features, functions and installation of the TE100-S55.
Chapter 1 provides an overview of Fast Ethernet and Switching technology, their uses and benefits in the currently emerging computing environment, and an overview of the TE100-S55.
Chapter2 describes the cabling rules and guidelines for integrating the TE100-S55 into a network.
Chapter 3 describes how to configure the TE100-S55 through the Out-of-band management.
Chapter 4 describes how to configure the TE100-S55 through the XPressView SNMP Management program.
Chapter 5 teaches how to identify the status LEDs of the TE100-S55 and how to isolate and solve problems.
TE100-S55
4
Page 5
Table of Contents
Chapter 1 INTRODUCTION
Fast Ethernet Technology 7
Switching Technology 8
10/100 Switching Technology 9
Benefits of Switching 9
Introducing the TE100-S55 10
Features of the TE100-S55 12
Chapter 2 GETTING STARTED
Cabling Rules and Site Preparation 13
Unpacking 16
The Front Panel 17
Mounting 18
Attaching Cables 18
Adding Optional Modules 19
Power ON 19
Software Setup 20
Checking Status LEDs 20
Chapter 3 CONFIGURING THE SWITCH
Introduction 21
Out-of-Band Management 22
Spanning Tree Algorithm 27
Chapter 4 SNMP MANAGEMENT
5
Page 6
Installing XPressView 36
Starting XPressView 37
Operating XPressView 38
Chapter 5 DIAGNOSTICS
Power-On Self Test 41
System Status LEDs 42
System Diagnostic LEDs 43
System Utilization LEDs 43
Port Status LEDs 44
APPENDICES
A ~ Switch Default Setting 45
B ~ RS-232 Pin Specification 46
C ~ RJ-45 Pin Specification 47
D ~ 10Base-T Module 49
E ~ 100Base-FX/TX Module 50
F ~ ISDN Module 52
G ~ Hardware Specification 54
INDEX 56
6
Page 7
Chapter 1 Introduction
Fast Ethernet Technology
The growing importance of LANs and the increasing complexity of desktop computing applications are fueling the needs for high performance networks. A number of high-speed LAN technologies are available to provide greater bandwidth and improve client/server response times. Among them, Fast Ethernet, also known as 100Base-T, provides the smoothest migration path for the current 10Base-T technology. The non­disruptive and smooth evolutionary nature of Fast Ethernet, plus its prevailing market acceptance, guarantees it as the most cost effective and high-performance networking solution of the future.
100Base-T networks essentially look and act like 10Base-T networks, only faster (see Table 1-1, page 8). 100Base-T provides 10 times the performance of 10Base-T while retaining most of the same cabling rules and the CSMA/CD media-access method. 100Base-T also uses the same packet format, packet length, error control and management information as 10Base-T. As such, 100Base-T is recognized as the true and rightful heir of 10Base-T.
For flexibility, the 100Base-T specification contains three different cabling schemes, 100Base-TX (Cat 5 UTP), 100Base-T4 (Cat 3,4 or 5 UTP) and 100Base-FX (fiber optic). 100Base-TX is probably the most popular choice since it enables users to retain their existing 10Base-T cabling infrastructure and easily migrate to Fast Ethernet.
7
Page 8
Ethernet Fast Ethernet
Speed
Cost
IEEE 802.3 Standard
Topology
Cable Supported
Cable Specification
Maximum distance of UTP link
Collision domain diameter (maximum distance w/UTP)
Maximum network diameter (using switches/routers)
Media Independent Interface
Full duplex Signaling
Table Chapter 1 -1, Ethernet vs. Fast Ethernet
10Mbps 100Mbps
x 2x or less
CSMA/CD CSMA/CD
Star or Bus Star
UTP, Coax, Fiber UTP, Fiber
10Base-T:Cat 3,4,5 UTP
10Base-2: Thin coax
10Base-F: Fiber optic
100 meters 100 meters
500 meters 210 meters
Unlimited Unlimited
Yes (AUI) Yes (MII)
Yes Yes
100Base-T4: Cat 3,4,5 UTP
100Base-TX: Cat 5 UTP
100Base-FX: Fiber optic
Switching Technology
Another approach to pushing beyond the limits of Ethernet is the development of Switching technology. A switch works in the MAC address level, bridging multiple Ethernet segments to prevent unnecessary network traffic from passing one another. In a properly subdivided switched LAN, the net result is a full and transparent bandwidth for each segment.
Switched Ethernet vs. Legacy Ethernet is analogous to using private telephone lines vs. party lines. By connecting to a switched port, each Ethernet segment has dynamic full
8
Page 9
performance or “wire-speed.” Therefore, a switch effectively splits a physical shared-access LAN into bridged multiple LAN segments. Each segment supports a workgroup and even provides a dedicated connection to a desktop server. The outcome is a multiplication of the overall available bandwidth and a more predictable performance under heavy network loads.
10/100 Switching Technology
Just as 100Base-T is an extension of the existing 10Base-T technology, 10/100 Switching is merely an extension of 10Base-T Switching. The 10/100 Switch provides not only the 10/100Mbps high-speed transmission rate per segment, but it also bridges 10Base-T and 100Base-T into a harmonious network.
Combining Fast Ethernet and Switching technologies, the 10/100 Switch provides enough bandwidth to satisfy the most demanding workgroups, as well as a high-speed backbone link.
Benefits of Switching
From the technical point of view, Ethernet switching technology dramatically boosts the total bandwidth of a network. It also puts configuration flexibility and bandwidth adaptability into the local workgroups where the majority of work is generated from a business operation. Switching further eliminates the congestion problem inherent to the contention oriented Ethernet CSMA/CD protocol, thereby improving predictable response times under heavy network loads. In the past, this congestion under heavy loads was alleviated using an expensive routing technology.
From the applications point of view, the new wave of object oriented distributed Client/Server applications demands higher bandwidth and tighter integration of client workstations with servers. The legacy shared-access 10Mbps Ethernet technology
9
Page 10
can no longer provide both bandwidth and predictable response times to this new generation of workgroup computing.
From an economical point of view, Fast Ethernet switching not only satisfies both technical and business requirements, but also preserves the users’ existing investment in the huge 10Base-T Ethernet installed base. This compatibility insures a path for users to add, change, and migrate to Fast Ethernet capabilities as needs arise. It also provides a low cost and flexible bandwidth solution directly to local workgroups, where the majority of work is generated and reducing the need of expensive routers that usually cater to the network backbone.
Introducing the TE100-S55
The word “flexible” best describes the characteristics of the TE100-S55 . Not only does it provide five fixed 10/100Mb ports, but it also provides an open slot for adding an 8-port 10Base-T module, a 100Base-FX/TX port or an ISDN router module. Users can hand-select the necessary modules to fit their individual needs.
With expandable switch functionality and ISDN router support, the TE100-S55 brings to the workgroup capabilities normally found in more expensive, chassis-based products. Dual-speed 10/100 configuration options also make the product ideal for integrating Fast Ethernet technology into existing 10Mbps network.
Both fixed and modular network ports on the TE100-S55 feature NWAY Auto-negotiation, to simplify installation and use. NWAY Auto-negotiation senses the network speed when cabling is inserted into the port, and automatically transmits at either 100Mbps or 10Mbps. In addition, it detects whether the device transmitting to the port is utilizing half or full-duplex signaling and configures itself without user intervention. When taking advantage of full duplex signaling, the TE100-S55 literally
10
Page 11
doubles network throughput to 200Mbps on Fast Ethernet segments and 20Mbps on 10Base-T segments.
Although the TE100-S55 is equipped with five ports for 10Base­T or 100Base-TX connections, it also provides an open slot for add-on modules. These modules include an 8-port 10Base-T, a 100Base-FX/TX port or an ISDN router.
Module Type Description Common Usage
10Base-T
100Base-FX/TX
ISDN Router (up to 128Kbps)
Eight RJ-45 ports for Cat 3, 4 or 5 UTP cable.
Refer to Appendix D, page 49 for more detail.
One MIC port for fiber optic cable plus one RJ-45 port for Cat 5 UTP cable.
Although two ports are provided, only one port may be used at a time.
Refer to Appendix E, page 50 for more detail.
One RJ-11 port for ISDN phone line (two-64Kbps channels).
Refer to Appendix F, page 52 for more detail.
Existing 10Base-T users who want to expand or segment their 10Base-T connections.
Fast Ethernet users who want to connect to fiber optic backbone or expand their 100Base-TX connection.
Ethernet or Fast Ethernet users who want to access remote locations or internet/intranet.
Table Chapter 1 -2, Description of Add-on Modules
11
Page 12
Features of TE100-S55
Utilizing the latest Fast Ethernet and Switching technologies, the TRENDnet TE100-S55 is designed to provide:
Five 10/100Mbps dual-speed Ethernet ports
One expansion slot with multiple configuration options:
8 switched ports for 10Base-T OR
2 switched port for 100Base-FX/TX OR 1 ISDN router (up to 128Kbps)
NWAY Auto-negotiation for each network port providing
auto-detection of connected cable type, auto-sensing of full or half duplex signaling and auto-configuration.
Full or half-duplexing.
Store-and-forward packet switching.
The IEEE 802.1d Spanning Tree Algorithm for network loop
detection and prevention and topology re-configuration.
Native SNMP management support with Ethernet MIB II (RFC 1284) and bridge MIB (RFC 1286).
Dynamic, automatic self-learning network configuration that is refreshed every three minutes for maximum performance.
VLAN support.
4,096 maximum entries for MAC Address Table.
One RS-232 port for local/remote Out-of-Band management.
The EEPROM (flash memory) for firmware upgrade.
Comprehensive LED display of the system/port status.
Self-test during power on to ensure system integrity.
12
Page 13
Chapter 2 Getting Started
Cabling Rules and Site Preparation
Although 100Base-T and 10Base-T are alike in many aspects, there are slight differences in the cabling rules. So, spend some time in locating and reconfiguring your cabling structure for the best network layout.
The key cabling rules for 100Base-TX are:
The 100Base-TX specification requires two-pair Category 5 UTP or two-pair Type 1 STP cable.
The maximum cable length from an end-station to a hub or repeater is 100 meters.
1
The maximum number of repeater
The maximum network diameter is 210 meters: two
segments of 100 meters with two repeaters/hubs no farther apart than 10 meters are allowed.
hops allowed is two.
Switches are not considered as a repeater. Therefore, there are no limitation to repeater hops or to the network diameter distance. However, the maximum cable length from an end­station to a switch still remains at 100 meters.
1
A single or a stacked 100Mbps hub is counted as one repeater. A
switch is not counted as a repeater, but is treated as an end-station when applying the topology rules.
13
Page 14
The TE100-S55 fits into the 100Base-T cabling architecture as a switch. Therefore, unlimited number of switches may be installed in the same network with maximum distances of 100 meters apart. The 10/100Mb ports of TE100-S55 require two-pair Cat5 UTP (or Type 1 STP) for 100Base-TX connections. For 10Base-T connections, two-pair Cat 3, 4 or 5 UTP cables are required.
Figure Chapter 2 -1, Example of TE100-S55 wiring
environment
14
Page 15
Careful planning and site preparation are the keys to success for installing Fast Ethernet switches. Users should perform a network bandwidth analysis based on their workgroup network traffic needs and examine their workstation equipment for other performance bottlenecks.
Figure Chapter 2 -2, 100Base-T cabling rules
15
Page 16
Unpacking and Setup
Now that you have a good understanding of the basic cabling rules, as well as your own network environment, you’re ready to integrate the TE100-S55 into the network.
The following sections describe how to install, connect and setup your new TE100-S55 .
UNPACKING
The TE100-S55 shipping carton should contain the following items:
1 TE100-S55 unit
1 AC power cord
2 Mounting brackets
1 RS-232 serial cable (6 ft)
This User’s Guide
If any item is found missing or damaged, please contact your local TRENDware reseller for replacement.
Figure Chapter 2 -3, Contents of the TE100-S55 Package
16
Page 17
THE FRONT PANEL
The TE100-S55 features following items on its front panel:
(A) Five RJ-45 ports for 10Base-T or 100Base-TX links
(B) An expansion slot with multiple configuration options:
(b1) 8-port 10Base-T Switch OR
(b2) 2-port 100Base-FX/TX Switch OR
(b3) 1-port ISDN router
(C) One RS-232, DB9 Out-of-Band management port
(D) Eight system status LEDs
(E) Eight system diagnostic LEDs
(F) Eight system utilization LEDs
(G) Six status LEDs for each port
(H) Power Status LED
Figure Chapter 2 -4, Front panel of the TE100-S55
17
Page 18
M
OUNTING
The TE100-S55 can be placed either on a table or rack mounted. For rack mounting: First screw the pair of mounting brackets (included in the packing carton) onto the switch. Then, mount the TE100-S55 onto the rack, as shown below in Figure 2-5.
Figure Chapter 2 -5, Rack mounting a TE100-S55
ATTACHING CABLES
There are five RJ-45 ports on the TE100-S55 for connecting five workstations or LAN segments. Each port supports either 10Base-T or 100Base-TX networks, auto-detecting the type of connection. For 100Base-TX connection, two-pair Category 5 UTP (or Type 1 STP) cabling is required. For the 10Base-T connection, two-pair Category 3, 4 or 5 UTP is required.
18
Page 19
If you are connecting workstations to the TE100-S55, use a standard UTP cable with a straight RJ-45 pin layout. If you are connecting hubs, bridges or other switches to the TE100-S55, the Transmit (TD) and the Receive (RD) wires must be crossed-over at one end of the connector. Please refer to Appendix C, page 47 for the details of pin layout.
ADDING OPTIONAL MODULES
Although the TE100-S55 is equipped with five ports for 10Base­T or 100Base-TX connections, it also provides an open slot for add-on modules. These modules include an 8-port 10Base-T, a 100Base-FX/TX port or an ISDN router.
To install add-on modules, simply unscrew and remove the slot cover from the front panel of the TE100-S55. Slide-in and screw the add-on module into the open slot of the TE100-S55. Afterwards, attach the appropriate LAN or WAN connections to each module.
Please refer to Appendix D~F (page 49-53) for more details on each add-on module and its installation process.
POWER ON
The TE100-S55 can be used with AC power sources, 90 - 250 VAC, 50 - 60 Hz. The internal power supply will adjust to the local power source automatically.
You may turn ON the power of the TE100-S55 with or without attaching LAN connections to the switch. You should observe the LEDs as the Switch is going through the Power-On Self Test (POST) sequence. All system Status LEDs should go off, and the Power LED should go on, when the POST is successful. The corresponding Link LED will be turned on when a LAN segment is connected to the port and functioning normally.
19
Page 20
S
OFTWARE SETUP
The default settings of TE100-S55 (shown in Appendix A, page
45) should be sufficient in the majority of installations. If a
different setting is required for your specific environment, please refer to Chapter 3, page 21 for “Out-of-Band Management” or Chapter 4, page 35 for “SNMP Management”.
For simple management, you can perform the Out-of-Band Management and access the TE100-S55 through its RS-232 port. For elaborate SNMP management, you can run the XPressView program from any network station.
CHECKING STATUS LEDS
When the power is first turned on, TE100-S55 performs a Power­On Self Test (POST). Please observe the status LEDs for verification of proper installation (for more detail, refer to Chapter 5, page 41). These status LEDs also provide information about the system unit and its connected Ethernet or Fast Ethernet LAN segments, during normal operation.
Figure Chapter 2 -6, TE100-S55 status LEDs
20
Page 21
Chapter 3 Configuring the
Switch
Introduction
The TE100-S55 is designed to operate with or without the aid of extensive network management software. For simple management, you can run a terminal emulation program and access the TE100-S55 through its RS-232 port. For elaborate SNMP management, you can run the XPressView program from any network station. Chapter 4 describes the details of how to install and utilize the XPressView SNMP Management program.
Out-of-Band Management is the vehicle to access TE100-S55 locally or remotely via its RS-232 serial port. Through this port, you can set up, monitor or modify the TE100-S55 configuration.
21
Page 22
Out-of-Band Management
ATTACHING TO THE RS-232 PORT
The TE100-S55 can be configured using the Out-of-Band Management function. To begin, you must first connect a PC (or a terminal) directly to TE100-S55 using the supplied RS-232 serial cable.
The RS-232 port is a DCE with a 9-pin female connector. Figure Chapter 3 -1 shows the cable connection to a DTE such as a PC running VT100 terminal emulation software or an actual VT100 terminal. The switch-to-terminal (DCE/DTE) serial communication speed is preset at 19,200 baud.
Refer to Appendix B for detailed pin specifications of the RS-232 port.
Figure Chapter 3 -1, RS-232 connection to a local
terminal
22
Page 23
VT100 TERMINAL
Once you’ve connected a PC (or terminal) to the RS-232 port of the TE100-S55, you can begin the VT100 terminal emulation process. The VT100 terminal emulation software can be found in Microsoft Windows or any other communication software.
Table 3-1 describe the necessary settings for your PC or terminal connection to TE100-S55.
Terminal Step VT100 Compatible
terminal
Communication software
DCE/DTE line setting
PC COM port hardware setting
Assigning control keys to a non-VT100 system software environment
Turn on the machine
and login as VT100
terminal
19,200 Baud, 8 N 1 (hardware setting)
N/A
N/A
Run the VT100 Terminal emulation software / This software can be found in MS Windows (Accessory section )or other communication software
19,200 Baud, 8 N 1 (through the Terminal software)
Refer to PC COM port hardware and Software setup guidelines
If your keyboard does not respond properly within the MS Terminal Emulation program, go to the Terminal Preference menu and Deselect the “Use function, arrow, Ctrl keys for Windows” option; or refer to specific terminal emulation software
Table Chapter 3 -1, VT100 Terminal Emulation Settings
PCVT100 terminal
emulation
23
Page 24
Upon a successful execution of terminal emulation, your computer will establish communication with the TE100-S55 and allow you to view or modify the following settings.
Control Settings System display User selection
Switch Configuration
Port Configuration
Spanning Tree Configuration
Down-load new system firmware
Load factory default parameters
Filtering Data Base
Switch Version No.
Switch IP Address
Switch Subnet Mask
Default Gateway
Switch MAC Addr.
Save change Exit
Port/x State
Port/x Physical
Port/x State
Port/x Priority
Enable / Disable
Bridge (switch) Priority
Root Cost
Hello Time
Forward Delay Time
Max Age Time
Root Bridge
Root Port
Y / N Exit
Y / N Exit
Port Number
Port State
MAC address
V1.10 (Fixed)
168.8.xx.xx
255.255.0.0
0.0.0.0
Factory preset (Fixed)
F2 key F4 key
Enable (or Disable)
Auto (or 100/Half, 100/Full,
10/Half, 10/Full)
Block, Learning, Listening, Forwarding, Disable (Fixed)
0 (Hi) - 255 (Low)
Enable (or Disable)
32768
(Reflected STA result)
10 sec. (range: 1 - 10 sec.)
30 sec. (range: 4 - 30 sec.)
40 sec. (range: 6 - 40 sec.)
(MAC addr. of Root Bridge)
(Reflected STA result)
Space Key (toggle)
F4 key
Space Key (toggle) F4 key
1 ~ 5
Disable (or Forwarding, Blocking)
Up to 16 MAC addresses
Table Chapter 3 -2, TE100-S55 Settings for Out-of-Band management
24
Page 25
U
SER-SELECTIVE PARAMETERS
The TE100-S55 is factory set with a unique Ethernet MAC address. Except for the MAC address, Version Number and Port State, all parameters in Table 3-2 can be modified.
From the Switch Configuration menu, you can change the IP Address of TE100-S55 to match the TCP/IP environment of your network. The Gateway Address may also be changed to match the Gateway of your network.
From the Port Configuration menu, you can Enable/Disable each port connection , and prioritize them (ranges from 0 to 255). The priority level, in conjunction with the preset port ID, is used under the Spanning Tree Algorithm to determine the “Root Port”. The Port State parameter corresponds to the Enable/Disable port settings and the dynamic changes in routing paths of the surrounding network. The Port State may show message Blocking, Learning, Listening, Forwarding or Disable, at any given time.
The Port Physical setting defaults to AUTO, but you can change it to 100Mb half duplex, 100Mb full duplex, 10Mb half duplex, or 10Mb full duplex mode. Although optional, the AUTO setting is recommended since it employs the NWAY Auto-negotiation feature of the TE100-S55, automatically detecting and selecting the optimum cable speed (10 or 100Mb) and signaling type (full or half duplex) for each port. When taking advantage of full duplex signaling, the TE100-S55 literally doubles network throughput to 200Mbps on Fast Ethernet segments and 20Mbps on 10Base-T segments.
From the Spanning Tree Configuration menu, you can Enable/Disable the STA function, change the switch priority and various timers. The STA functions and parameters are discussed in full detail on page 27.
25
Page 26
From the Down-load New System Firmware menu, you can upgrade the TE100-S55 with the latest firmware (if revision is available). The XMODEM function will guide you in downloading the firmware code into the TE100-S55. To acquire the revised firmware file, please contact TRENDware technical support.
From the Load Factory Default Parameters menu, you can replace all parameter modifications for TE100-S55 with the original default settings.
From the Filtering Data Base menu, you can Disable, Forward or Block up to 16 MAC addresses for each port on the TE100-S55. This feature allows you to create a virtual LAN, filtering each segment for added performance.
26
Page 27
Spanning Tree Algorithm
In a more complex network environment, devices may physically be connected in a loop, causing network failure due to the infinite transfer of packets. In anticipation of such perplexity, the TE100-S55 is designed to support the Spanning Tree Algorithm (STA). Using STA, the TE100-S55 will prevent network loops by logically designating a single path for each connection, as well as establishing a backup path in case of a path failure.
Specifically, Spanning Tree Algorithm (STA) provides the following services:
Network loop detection and prevention - Only one path is allowed between any two switch/bridge segments. If there are multiple paths, forwarded packets may loop indefinitely and result in serious network failure. When STA detects a loop, it activates the path with the lowest “path cost”, while blocking the other paths.
Automatic topology re-configuration - If an active path fails, the backup path will be automatically activated, and the STA will auto-configure the network topology.
In a simple network where there is no possibility of network looping, you may disable the STA function. However, if the possibility of network loops exist, just leave the STA enabled along with other switches/bridges in the network. The TE100­S55 will interact with other switches/bridges to dynamically establish forwarding paths within the network.
Subsequently, the TE100-S55 may be referred to as a bridge. Since a switch is analogous to a bridge, the STA rules of a bridge applies equally to the TE100-S55.
27
Page 28
You can view or modify the STA parameters through the Out-of­Band Management, as shown in Table 3-3. Pay special attention to the effects of each STA parameter in order to avoid erroneous behavior in the network.
STA parameters Settings Effects Comment
Enable/Disable
Bridge Priority
Hello Time
Max. Age Time
Forward Delay
Enable / Disable
lower the #, higher the priority
1 - 10 sec. No effect, if not
6 - 40 sec. Compete for
4 - 30 sec. High # delays
Participate in or remove from STA
Increases chance of becoming the Root Bridge
Root Bridge
Root Bridge, if BPDU is not received
the change in state
Enable in a SNMP network
Avoid, if the switch is used in workgroup level of a large network
Never set greater than Max. Age Time
Avoid low number for unnecessary reset of Root Bridge
Max. Age ≤ 2 x (Forward Delay -
1) Max. Age ≥ 2 x (HelloTime + 1)
Port Level STA parameters
Enable / Disable
Port Priority
Table Chapter 3 -3, User-selective STA parameters
Enable / Disable
lower the #, higher the priority
Enable or disable this LAN segment
Increases chance of become Root Port
28
Disable a port for security or problem isolation
Page 29
STA operates at two levels, the Switch and the Port level. In addition, STA uses several timers to periodically ensure the integrity of switches/bridges and their ports in a network.
The following paragraphs introduce the key information and terminology needed to understand the STA parameters. Please note that the word “bridge” now refers to TE100-S55.
AT THE BRIDGE LEVEL
Root Bridge: A network must first establish a starting point
from which all data forwarding path values are calculated, compared, and determined. The Root Bridge is the unit with the lowest Bridge Identifier
Bridge Priority: This is a user changeable parameter. This parameter enables all bridges in the network to establish a Root Bridge. A change to the Bridge Priority may cause the network to re-establish a new Root Bridge. A high Bridge Priority increases the chance for a bridge to be selected as the Root Bridge (the smaller the number, the higher the priority).
Root Path Cost: From each bridge, Root Path Cost is the total Path Cost of reaching the Root Bridge from a Designated Bridge. A Root Bridge has Root Path Cost of 0.
1
(Bridge Priority + MAC address).
Designated Bridge: From each LAN segment, the bridge that has the lowest Root Path Cost to the Root Bridge becomes the Designated Bridge. It forwards data packets for that LAN segment. In case all bridges on a segment have the same Root Path Cost, the bridge with the lowest Bridge Identifier becomes the Designated Bridge.
1 The bridge MAC address is only used to decide the Root Bridge when
there are 2 or more bridges with the same Bridge Priority.
29
Page 30
A
T THE PORT LEVEL
Designated Port: This is the port on each Designated Bridge that
forwards data packets for the attached LAN segment.
Root Port: Each bridge has a Root Port that has the lowest Path Cost to the Root Bridge. In case there are several ports with the same Path Cost, the one with the lowest Port Identifier (Port Priority + pre-assigned Port ID) becomes the Root Port
1
.
Port Priority: This is a user changeable parameter for each port on the bridge. In conjunction with a pre-set port ID, this parameter determines the Root Port of a Bridge.
2
Path Cost: This parameter is fixed
and will not be shown. The 100Mb segments will have auto-assigned Path Cost of 10, while the 10Mb segments will have auto-assigned Path Cost of 100.
1
In a bridge, a port is Blocked, if it is not a Root or a Designated Port.
2
This is a changeable parameter, based on the STA specification.
However, it is fixed by the TE100-S55 implementation.
30
Page 31
T
IMERS
Max. Age Time: This is a user changeable parameter. Should a
Bridge fail to receive an identifier packet from its Root Bridge within this time limit, it assumes that the Root Bridge has failed. Therefore, a new Root Bridge will be established for the network.
Hello Time: This is a user changeable parameter. Should a Bridge be assigned as a Root Bridge, the Hello Time setting will be used as the interval to send out identifier packets to notify other Bridges of its existence. The Hello Time must be less than the Max. Age Time, or else a configuration error will occur.
Forward Delay: This is a user changeable parameter. This is the delay time that each port on a Bridge waits in the Listening state before changing its Blocking state to the Forwarding state.
31
Page 32
I
LLUSTRATION OF STA
A simple illustration of three Bridges (or TE100-S55) connected in a loop is depicted in Figure 3-2. In this example, you can anticipate some major network problems if the STA assistance is not applied. For instance, if Bridge 1 broadcasts a packet to Bridge 2, Bridge 2 will broadcast it to Bridge 3, and Bridge 3 will broadcast it to Bridge 1...and so on. The broadcast packet will be passed indefinitely in a loop, causing a serious network failure.
To alleviate network loop problems, STA can be applied as shown in Figure Chapter 3 -3. In this example, STA breaks the loop by blocking the connection between Bridge 1 and 2. The decision to block a particular connection is based on the STA calculation of the most current Bridge and Port settings. Now, if Bridge 1 broadcasts a packet to Bridge 3, then Bridge 3 will broadcast it to Bridge 2 and the broadcast will end there.
STA setup can be somewhat complex. Therefore, you are advised to keep the default factory settings and STA will automatically assign root bridges/ports and block loop connections. However, if you need to customize the STA parameters, refer to Table 3-3 on page 28.
32
Page 33
R
D
t
R
t
LAN 1
D
t
D
t
LAN 2
LAN 3
LAN 1
LAN 2
LAN 3
Path Cost = 100
Port 1
Bridge 1
Port 2
Path Cost = 100
Path Cost = 100
Port 1
Bridge 2
Port 2
Path Cost = 100
Bridge ID = 21
Bridge ID = 30
Figure Chapter 3 -2, Before Applying the
STA Rules
oot Por
Port 1
Bridge 1
Port 2
Port 1
Bridge 2
Port 2
Root Path Cost = 100 Bridge ID = 21
esignated Por
Block Path
Root Path Cost = 100 Bridge ID = 30
oot Port
Path Cost = 100
Port 1
Bridge 3
Port 2
Path Cost = 100
Port 1
Bridge 3
Port 2
Bridge ID = 15
esignated Por
Root Path Cost=0 Bridge ID = 15
esignated Por
Figure Chapter 3 -3, After Applying the STA Rules
33
Page 34
34
Page 35
Chapter 4 SNMP Management
For basic setup of the TE100-S55, use the out-of-band management functions as described in Chapter 3. However, for a user-friendly graphic interface to your TE100-S55 setup, you can use the XPressView SNMP Management program.
The XPressView program permits you to view or modify the TE100-S55 configuration and its network activities. Specifically, it allows you to do the following management functions:
Enable/Disable each Port State.
View the Switch Configuration.
Modify the parameters for Spanning Tree Algorithm.
Monitor the incoming and outgoing network traffic.
35
Page 36
Installing XPressView
Installing the XPressView SNMP Management program is easy to do and only takes a few minutes. The supplied SETUP program guides you through the process.
WHAT YOU NEED
To use XPressView, your computer must have the following:
Processor:
RAM:
Disk Space:
Windows:
TCP/IP
Drive:
Display:
386, 486 or Pentium
2 megabytes minimum
10 megabytes minimum
3.1, 3.11 or Win95
Winsock interface
(It is recommended to set the IP address at 168.8.xx.xx, similar to the TE100­S55 IP address)
1.44 Floppy
VGA
TO INSTALL XPRESSVIEW
Run Windows and close all programs that are active.
Insert the supplied XPressView diskette into your floppy
drive.
From Windows Program Manager or Explorer, click the
floppy drive that contains XPressView, and click the SETUP command. The setup screen will appear. Accept or modify the Destination Directory and click NEXT.
The XPressView program icon will automatically be added to
your Windows start screen.
36
Page 37
Starting XPressView
After you install the XPressView program, you are ready to begin SNMP management of your TE100-S55.
From Windows start screen, click the XPressView icon. The Welcome screen will appear.
START FROM SCRATCH
If this is your first time to run the XPressView program, you will need to create an environment that represents the TE100-S55.
Click the AUTO DISCOVERY icon.
Enter the range of IP addresses to
search and XPressView will auto-detect all of the TE100-S55 switches in your network.
**As an option, you can click the DEVICE icon and
manually type each IP address of your TE100-S55.
For future use, save this environment by going to the NETWORK menu and clicking the SAVE command.
NOTE: Each switch must have a unique IP address in order to communicate with the network manager. The factory default IP address of each TE100-S55 is 168.8.xxx.xxx. The last two bytes of the IP address are identical to the last two bytes of the MAC address, which is displayed on the back of each TE100-S55. The MAC address can also be referenced through out-of-band management (see chapter 3, page 24).
37
Page 38
O
PEN AN EXISTING ENVIRONMENT
To open an existing environment, go to the NETWORK menu and click the OPEN command. Choose the appropriate file name and click the OK command. Your screen will display the list of TE100-S55 icons and will allow management of these devices.
Operating XPressView
Once you create or open an environment, you are ready to view or modify the TE100-S55 configuration and its network activities.
SELECT A DEVICE
From the main screen, click the TE100-S55 icon and the management menu will appear.
From the management menu, choose a port by clicking the port­icon. Afterwards, choose the management function by clicking one of the management-icon:
View/Modify the Switch Configuration.
Modify the parameters for Spanning Tree Algorithm.
Monitor the incoming and outgoing network traffic.
38
Page 39
V
IEW/MODIFY SWITCH CONFIGURATION
If you click a port and then click the “Switch Configuration” icon, the following screen will appear, allowing you to Enable or Disable the selected port.
However, if you click the “Switch Configuration” icon without clicking a port, the following screen will appear allowing you to view the IP, Subnet mask and MAC addresses.
MODIFY THE SPANNING TREE ALGORITHM
If you click a port and then click the “STA” icon, the Port STA screen will appear, allowing you to modify the port priority.
However, if you click the “STA” icon without clicking a port, the following screen will appear, allowing you to modify the Bridge Priority, Max, Hello and Forward parameters.
39
Page 40
M
ONITOR NETWORK TRAFFIC
When you click the “Monitor Network Traffic” icon, a query control screen will appear, allowing you to choose the type of packets to monitor. Click the packet types from the OID List, and then click one of the Display types (text or graphic).
Display in TEXT format
Display in GRAPHIC format
40
Page 41
Chapter 5 Diagnostics
Power-On Self Test
A Power-On Self Test (POST) sequence takes place when the TE100-S55 is first turned on (cold boot). Software reset (warm boot) through the RS-232 port does not prevent unauthorized remote re-boots.
The POST sequence checks the system integrity by performing the following tests:
System boot
RAM test
Timer and interrupt controller tests
Cache controller test
RS-232 diagnostic port test
BIOS test
EEPROM checksum test
Program load checksum test
Ethernet ports test
Besides the Power On/Off LED, there are eight system Status LEDs used to display the results of these tests during the POST sequence. The LED status further display test results in two categories, the System test and the Port test. Any errors from the System tests means that the Switch failed to function. Any error(s) from the Port test effects that individual port and the remaining ports will be operational.
41
Page 42
System Status LEDs
TE100-S55 is equipped with eight Status LEDs which reflect the Power-On Self Test results. If there is a system error, the Status LED light will be ON and the LEDs - will display the error code.
Although some errors may be resolved easily, some errors may require that the unit be returned to TRENDware reseller for repair.
System error LED
Off -  On -  
 
 
 
 
 
 
 
 
 
 
Port error LED

LED is
reserved.


1 2 3 4 5 port position
No error
Boot
RAM
Interrupt controller Timer controller Cache controller
RS-232 port
BIOS
EEPROM
Program down-load
Port 1 - 5 error (s)
Error
Status
Normal
Record LED error code and contact technical support Record LED error code and return the unit. Record LED error code and return the unit. Record LED error code and return the unit. Record LED error code and return the unit. Record LED error code and return the unit. Record LED error code and contact technical support Record LED error code and contact technical support Record LED error code and contact technical support
The system board is OK; the reported port(s) is disabled.
Record LED status and contact technical support.
Action
42
Page 43
System Diagnostic LEDs
TE100-S55 is equipped with eight Diagnostic LEDs which reflect status of add-on modules. The details of LEDs will be supplied with each optional module package and will not be covered in this manual.
System Utilization LEDs
TE100-S55 is equipped with eight Utilization LEDs which reflect the LAN’s percentage of utilization. This is a measure of the traffic on the network.
The LEDs LEDs increase in number, the network administrator should consider optimizing the network for reduced traffic.
 -  indicates a low traffic on the network, while the
- indicates a high traffic on the network. As the LEDs
43
Page 44
Port Status LEDs
TE100-S55 is equipped with six Status LEDs which reflect the status of each port.
As you connect a network cable to the TE100-S55, it will auto­detect the type of cable and the corresponding 10/100 LED will light up. Likewise, depending on the port connection, the DUPLEX LED will light up to indicate its status of full or half duplex signaling.
When a port connection is active, the LINK LED will light up to indicate its operative state. Also, as activities occur on the network, the RX or TX LED will light up to indicate its transmission or reception of data.
When multiple packets are delivered at the same time, a collision will occur and the COL LED will light up. Although collisions are normal, if there’s too much, you should consider rearranging the workgroups or optimize the network for reduced traffic.
Port LED Status Port State Action
10/100
Duplex
Link
Tx or RX
Col
On
Off
On
Off
On
Off
Off
Blinking
On
Off
Blinking
On
100Mbps
10 Mbps
Full Duplex
Half Duplex
Port Connection Normal
Port Connection Inactive
No packet traffic
TD or RD Active
Heavy packet traffic
No collision
Collision Active
Jabber, serious problem
Check connections on this cable segment
Check if consistently heavy
Normal
Normal
Check this segment
44
Page 45
Appendices
Appendix A Switch Default setting
Parameter Default Range Data type
Spanning Tree State
Bridge Priority
Hello Time
Max Age Time
Forward Delay Time
Aging Time
IP Address 168.8.xx.xx
Subnet Mask 255.255.0.0
Gateway Address 0.0.0.0
MAC Address 0080C8xxx
Port State
Port Physical
Port(s) Priority
Filtering Data Base (Port State)
Note: Bold type face indicates user-selective parameters.
Enable
32768
10 sec.
40 sec.
5 sec.
300 sec.
Enable
Auto
128
Disable
Enable/Disable
0 - 65535 Integer
1 - 10 sec. Integer
6 - 40 sec. Integer
5 - 30 sec. Integer
0 - 10 ∧ 6
0 - 255 Integer
Disable Forwarding Blocking
The TE100-S55 default parameter settings
Integer
45
Page 46
Appendix B RS-232 Pin Specification
The RS-232 serial port of the TE100-S55 uses a 9-pin female connector. The port can be connected to a PC emulating a VT100 terminal or an actual VT100 terminal.
For a local connection, the table below shows the pin layout of a 9 to 9-pin or a 9 to 25-pin cable connection between the TE100-S55 and the management terminal.
TE100-S55 (DCE) Terminal (DTE)
Pin
Signal name for 9-pin for 25-pin Signal
number
1 not used 1 - not used
2 transmit (TD) 2 3 RD
3 Receive (RD) 3 2 TD
4 Data Carrier Detect
(DCD)
5 signal ground (SG) 5 7 SG
6 Data Terminal Ready
(DTR)
7 clear to send (CTS) 7 4 RTS
8 request to send (RTS) 8 5 CTS
9 not used 9 - not used
The TE100-S55 to Terminal RS-232 pin connections
4 20 DTR
6 8 DCD
name
46
Page 47
Appendix C RJ-45 Pin Specification
When connecting the TE100-S55 to another switch, bridge or a hub, a modified cross-over cable is necessary. Please review these products for matching cable pin assignments.
The following diagram and tables show the standard RJ-45 receptacle/connector and their pin assignments for the switch-to­network adapter card connection and the cross-over cable for the switch-to-switch/hub/bridge connection.
The standard RJ-45 receptacle/connector
47
Page 48
Contact Media Direct Interface Signal
1
2
3
4 not used
5 not used
6
7 not used
8 not used
TD + (transmission)
TD - (transmission)
RD + (reception)
RD - (reception)
The Standard Category 3 cable, RJ-45 pin assignment
1 TD + 2 TD -
3 RD + 6 RD -
4 TD + 5 TD -
7 RD + 8 RD -
1 TD + 2 TD -
3 RD +
4 TD + 5 TD -
7 RD +
6 RD -
8 RD -
The pin assignment for Category 5, 4-pair cross-over cable
48
Page 49
Appendix D 10Base-T Module
The 10Base-T specification is the most popular cabling scheme for conventional 10Mb Ethernet networks and is used in over 70% of LANs worldwide.
Although the TE100-S55 is equipped with five ports for 10Base­T connections, it also provides an open slot for an optional 8-port 10Base-T module.
The 10Base-T module uses inexpensive two-pair Category 3, 4 or 5 UTP cable. It services distance of up to 100 meters and supports full or half-duplexing.
How to Install the 10Base-T module
Unscrew and remove the cover slot from the front panel of the TE100-S55.
Slide-in and securely screw the 10Base-T module into the open slot of the TE100-S55.
Attach the UTP cable into the RJ-45 connectors of the 10Base-T module.
49
Page 50
Appendix E 100Base-FX/TX Module
The physical specification for Fast Ethernet cabling comes in three different flavors. These include 100Base-TX (2-pair over Cat 5 UTP), 100Base-T4 (4-pair over Cat 3 UTP), and 100Base­FX (2 fiber connections).
The 100Base-TX specification is the most popular cabling scheme for Fast Ethernet networks. Since it requires a UTP cable similar to 10Base-T, installation and configuration of 100Base­TX cabling is easy and cost-effective.
In contrast, the 100Base-FX specification requires the fiber optic cabling which is more expensive than the conventional UTP cabling. However, it has a definite appeal to widespread LANs where cost of wiring is less important than the distance it delivers to Ethernet LANs--400 meters for half-duplex segments and 2 kilometers for full-duplex segments.
For flexibility, the TE100-S55 provides an 100Base-FX/TX module that’s equipped with both Fiber Optic and UTP ports. It permit the users to choose the necessary cabling type that fits their individual needs.
The 100Base-TX port requires two-pair Category 5 UTP cable or two-pair Type 1 STP cable. It services distance of up to 100 meters and supports full or half-duplexing. The 100Base-FX port requires one pair of 62.5/125 micron fiber-optic cable. It services distance of up to 400 meters and supports full or half-duplex operation. It is an ideal solution for backbone connections.
Although the 100Base-FX/TX module is equipped with two ports (MIC and UTP connectors), please keep in mind that only one port may be used at a time.
How to Install the 100Base-FX/TX module
50
Page 51
Unscrew and remove the cover slot from the front panel of the TE100-S55.
Slide-in and securely screw the 100Base-FX/TX module into the open slot of the TE100-S55.
Attach either the Fiber Optic cable or Cat 5 UTP cable to the 100Base-FX/TX module. Although this module is equipped
with two ports, only one port may be used at one time.
51
Page 52
Appendix F ISDN Module
An Integrated Services Digital Network (ISDN) is one of the most rapidly expanding technologies for transmitting data and voice over wide area networks (WANs). The popularity of ISDN is due to its high-speed WAN connections at low cost, enabling greater productivity not only for home office workers or internet users, but also for corporate branch offices and remote sites.
In comparison, ISDN can transfer data more than four times as fast as a cutting-edge 28.8 Kbps modem. In its simplest form, ISDN offers the Basic Rate Interface (BRI), which has two 64Kbps B channels and a single 16Kbps D channel. The B channels can be combined, making the maximum transmission rate of 128Kbps. Furthermore, data compression enables an ISDN link to achieve up to 512Kbps transmission speeds.
ISDN provides high-speed remote access that is ideal for applications where analog connections are too slow and T1 connections are too expensive.
The ISDN Router module for the TE100-S55 is an excellent solution for connecting individuals or offices to headquarters or to the internet/intranet. It offers the equivalent bandwidth and reliability of leased lines at a significantly lower cost.
The ISDN Router module uses a single ISDN BRI capable of sending data over one B channel for data rates of 64Kbps or use both B channels for data rates of up to 128Kbps. Optional data compression can boost throughput up to 4-to-1 (512Kbps), depending on the data being transferred.
How to Install the ISDN module
52
Page 53
Unscrew and remove the sot cover from the front panel of the TE100-S55.
Slide-in and securely screw the ISDN module into the open slot of the TE100-S55.
Attach the ISDN phone line into the RJ-11 port of the ISDN module.
53
Page 54
Appendix G Hardware Specifications
SWITCH SPECIFICATION
Complies to IEEE 802.3 CSMA/CD 10Base-T, 100Base-TX, 100Base-FX Ethernet Standards
Complies to IEEE 802.1d Spanning Tree, IEEE 802.2 LLC,
and ISO 8807-3 standards
Switched IEEE 802.3 MAC layer frame size: 64-1518
NWAY Auto-negotiation for each network port providing
auto-detection of connected cable type, auto-sensing of full or half duplex signaling and auto-configuration
Store-and-forward packet switching
Native SNMP management support with Ethernet
MIB II (RFC 1284) and bridge MIB (RFC 1286)
VLAN support
4,096 maximum entries for MAC Address Table
Comprehensive LED display of the system/port status
128KB EEPROM (flash memory) for firmware upgrade
One RS-232D (DB-9) port for Out-of-Band management
(asynchronous, 8-bit data, 1 stop bit, no parity, 19.2K baud)
Rack mountable (Fits standard 2U EIA 19” rack)
Five 10/100Mbps LAN ports built-in
Optional slot for add-on modules
ORT SPECIFICATION
P
54
Page 55
5 x 10/100Mbps LAN ports (fixed)
Five RJ-45 ports for Cat 3, 4 or 5 UTP cable
10 or 100Mbps data transfer rate
Full or half duplexing
NWAY Auto-negotiation
8 x 10Mbps LAN ports (optional module)
Eight RJ-45 ports for Cat 3, 4 or 5 UTP cable
10Mbps data transfer rate
Full or half duplexing
NWAY Auto-negotiation
1 x 100Base-FX/TX LAN port (optional module)
One MIC port for 62.5/125 microns multimode fiber optic
One RJ-45 ports for Cat 5 UTP or STP cable
100Mbps data transfer rate
Full or half duplexing
NWAY Auto-negotiation
1 x ISDN WAN port (optional module)
One RJ-11 port for ISDN phone line
Up to 128K baud rate (two 64Kbps channels)
P
HYSICAL CHARACTERISTICS
Operating temperature: 0 - 50 degrees Celsius Humidity: 5% - 95% non-condensing Input power: 90 - 250 VAC, 50 - 60 Hz auto-select Power consumption: 20 watts maximum Emission: FCC Class A, CE mark Safety: UL, CSA Ventilation: 2 built-in DC fans Dimension: 17.36 in (w), 2.85 in (h), 9.37 in (d) Weight: 8 lb. Warranty: One year parts and labor
55
Page 56
INDEX
100Base-T .......................................................................See Fast Ethernet
Adding Optional Modules ...................................................................... 19
Add-on modules ..................................................................................... 11
100Base-FX/TX Module.................................................................. 50
10Base-T Module............................................................................. 49
ISDN Module................................................................................... 52
Attaching Cables .................................................................................... 18
Attaching to the RS-232 Port ................................................................. 22
Bridge Priority................................................................................ 28, 29
Cabling rules for 100Base-TX................................................................ 13
Checking Status LEDs............................................................................ 20
CSMA/CD.................................................................................. 7, 8, 9, 54
TE100-S55 ................................................................................ 10, 11, 12
Designated Bridge................................................................................. 29
Designated Port .................................................................................... 30
Down-load New System Firmware ........................................................ 26
Ethernet................................................................................................... 8
XPressView ..............................................................16, 20, 21, 35, 36, 37
Fast Ethernet .................................................................7, 8, 9, 10, 11, 50
Filtering Data Base................................................................................. 26
Forward Delay ................................................................................ 28, 31
Front Panel ......................................................................17, 19, 49, 51, 53
Gateway Address............................................................................ 24, 25
Hardware Specifications......................................................................... 54
Hello Time................................................................................. 24, 28, 31
Installing XPressView............................................................................ 36
IEEE 802.1D .................................................................................... 12, 54
IP Address............................................................................24, 25, 36, 37
ISDN ...............................................................................10, 11, 12, 17, 52
LEDs ...................................................................17, 19, 20, 41, 42, 43, 44
Load Factory Default Parameters........................................................... 26
Max. Age Time................................................................................ 28, 31
56
Page 57
Modify the Spanning Tree Algorithm .................................................... 39
Monitor Network Traffic........................................................................ 40
NWAY Auto-negotiation ..................................................... 10, 12, 25, 54
Operating XPressView ........................................................................... 38
Out-of-Band Management................. 12, 17, 20, 21, 22, 24, 28, 35, 38, 54
Path Cost ............................................................................. 27, 29, 30, 45
Port Configuration.................................................................................. 25
Port Physical setting........................................................................ 25, 45
Port Priority.............................................................................. 28, 30, 39
Port State........................................................................24, 25, 35, 44, 45
Port Status LEDs .................................................................................... 44
POST.......................................................................................... 19, 20, 41
Power ON............................................................................................... 19
Power-On Self Test .................................................................... See POST
Priority level........................................................................................... 25
Rack mounting ....................................................................................... 18
RJ-45 Pin Specification .......................................................................... 47
Root Bridge ....................................................................24, 28, 29, 30, 31
Root Path Cost...................................................................................... 29
Root Port ............................................................................. 24, 25, 28, 30
RS-232 Pin Specification ....................................................................... 46
Service and support................................................................................ 3
SNMP Management ......................................12, 16, 20, 21, 35, 36, 37, 54
Spanning Tree Algorithm..........................................12, 25, 27, 35, 38, 39
STA parameters.......................................................................... 28, 29, 32
Starting XPressView .............................................................................. 37
Switch Configuration ......................................................24, 25, 35, 38, 39
Switch Default setting ............................................................................ 45
Switching Technology.............................................................................. 8
System Diagnostics LEDs ...................................................................... 43
System Status LEDs............................................................................... 42
System Utilization LEDs........................................................................ 43
Terminal emulation .............................................................. 21, 22, 23, 24
Unpacking .............................................................................................. 16
VT100 Terminal......................................................................... 22, 23, 46
57
Loading...